• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.026 seconds

Gamma Ray Shielding Study of Barium-Bismuth-Borosilicate Glasses as Transparent Shielding Materials using MCNP-4C Code, XCOM Program, and Available Experimental Data

  • Bagheri, Reza;Moghaddam, Alireza Khorrami;Yousefnia, Hassan
    • Nuclear Engineering and Technology
    • /
    • v.49 no.1
    • /
    • pp.216-223
    • /
    • 2017
  • In this work, linear and mass attenuation coefficients, effective atomic number and electron density, mean free paths, and half value layer and $10^{th}$ value layer values of barium-bismuth-borosilicate glasses were obtained for 662 keV, 1,173 keV, and 1,332 keV gamma ray energies using MCNP-4C code and XCOM program. Then obtained data were compared with available experimental data. The MCNP-4C code and XCOM program results were in good agreement with the experimental data. Barium-bismuth-borosilicate glasses have good gamma ray shielding properties from the shielding point of view.

The Study for Optimal Exposure Condition of Chest Examination of Digital Radiography System (디지털 방사선 촬영장치의 흉부촬영 최적 조사조건에 관한 연구)

  • Park, Ji-Koon;Jung, Bong-Jae;Park, Hyong-Hu;Noh, Si-Cheol;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.2
    • /
    • pp.109-115
    • /
    • 2016
  • Despite of increasing the use of the digital imaging device in the radiology area, the setting on the optimal irradiation conditions are insufficient. In this study, the exposure dose and image quality by exposure condition of digital radiography device were compared. The exposure doses were obtained by adjusting the exposure condition as 5 steps respectively based on the exposure conditions that are currently used of CR and DR radiography devices. The acquired image has been assessed by 20 medical image professors using the assessment method of the Japanese Society for Tuberculosis Prevent. As a result, in the case of the CR system, the better image quality was obtained in the condition of 120 kVp and 1.5 mAs~2.4 mAs (quality score 91~95.5 points) than standard exposure condition(110 kVp, 3.2 mAs, 86 points). And exposure dose was evaluated as low with $61.3{\sim}98.4{\mu}Gy$ than standard condition($105.11{\mu}Gy$). In DR system, however, the image quality score was higher as 97~98.6 points in the lower tube voltage range (112 kVp, 2.4~3.2 mAs) condition than the standard exposure condition (125 kVp, 3.2 mAs, 91 points). In addition, the exposure dose was $61.5-77.2{\mu}Gy$ lower than standard condition($93{\mu}Gy$). In addition, the exposure dose was low as $61.5-77.2{\mu}Gy$ than standard condition($93{\mu}Gy$). With the results of this study, we confirmed that it is possible to reduce the patient exposure dose with the same image quality by adjusting the optimal exposure condition of digital device.

Radiation Dose Measurement of D-Shuttle Dosimeter for Radiation Exposure Management System (방사선피폭관리시스템를 위한 D-Shuttle 선량계의 방사선 선량측정)

  • Kweon, Dae Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.321-328
    • /
    • 2017
  • The purpose of the study is to provide basic data for the management of individual exposure and the monitoring of natural radiation dose using D-Shuttle dosimeter (Chiyoda Technol Corporation, Tokyo, Japan). The dose was calculated using D-Shuttle dosimeter. The dose was 1.346 mSv when exposed for 400 days, the annual dose per year was 1.228 mSv/year and the average dose per hour was $0.014{\mu}Sv/hr$. Domestic individual external dose (1.295 mSv/year = Korea average natural individual external dose) and domestic additional dose per year is -0.0663 mSv/year. D-Shuttle is a personal dosimeter for radiation monitoring. It can be used as a very useful dosimeter for ALARA because of its excellent detection capability of radiation, real-time radiation exposure management, alarm function of radiation work, and efficient and easy to use personal radiation dose management.. Radiation monitoring equipment for radiation workers and local residents can be used for radiation monitoring in hospitals, industry, medical sites, nuclear accident areas and hazardous areas in non-destructive areas.

Development of Open Clinical Training Program to Improve Radiology-Major Students' Clinical Competency (방사선(학)과 재학생의 임상적응 향상을 위한 개방형 임상실습 프로그램의 제안)

  • Kim, Seon-Chil
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.193-201
    • /
    • 2010
  • This study aimed to develop an open clinical training program to improve radiology graduates' clinical competency in the hospital setting to raise quality of patient-centered medical service. Development of the training program is similar to that of an instructional system design model. The program was developed according to the ADDIE model. Elements of each phase were collected. Draft of the program was constructed from literature review and clinical demands. Preliminary training program was implemented to sample students with the draft. After consultation with related professionals, the program was modified and completed. Professional groups assessed content validity of the program. Five continuous phases of the program - analysis, design, development, implementation, and evaluation - accommodate changes in clinical environment and demands. They also provide adequate learning needs. Effectiveness of the program and appropriateness of contents in each phase achieved a satisfactory level of significance. This program reflected demands from medical fields and effective learning programs. The purpose of the open clinical training program is to train radiological technologists in clinical setting to actively engage in patient-centered medical service and to help utilize their professional knowledge.

Assessment of dose effects on image quality at chest computed radiography (흉부 CR 영상에서 선량이 화질에 미치는 영향에 대한 평가)

  • Kang, Bo-Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.421-426
    • /
    • 2011
  • This research was accomplished to assess dose effects on image quality at computed radiography (CR). The ultimate target of the research was finding optimized exposure that provides necessary image quality for the clinical chest diagnosis. Modulation transfer function (MTF), normalized noise power spectrum (NNPS), and Noise equivalent quanta (NEQ) corresponding to the different doses were measured for the assessment of image quality. The preparation of "edge test device" used in MTF measurement and experimental geometry setup were followed by the recommendations of International Electrotechnical Commission (IEC). The experimental results show the necessary image quality can be achieved even at a half of the automatic exposure control (AEC) setting dose for chest diagnosis. It means that the patient exposure can be reduced dramatically by using optimized dose.

A Case Study of Three Dimensional Human Mimic Phantom Production for Imaging Anatomy Education (영상해부학 교육을 위한 3차원 인체 모사 조형물 제작 사례 연구)

  • Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.71-78
    • /
    • 2018
  • In this study, human mimic phantoms outputted by three-dimensional (3D) printing technology are reported. Polylactic acid and a personal 3D printer - fused deposition modeling (FDM) - are used as the main material and the printing device. The output of human mimic phantoms performed in the following order: modeling, slicing and G-code conversion, output variable setting, 3D output, and post-processing. The students' learning satisfaction (anatomical awareness, study interest) was measured on 5-point Likert scale. After that, Twenty of those phantoms were outputted. The total output took 11,691 minutes (194 hours 85 minutes) and the average output took 584.55 minutes (9 hours 7 minutes). The filament used for the experiment was 2,390.2 g, and the average use of the filament was 119.51 g. The learning satisfaction of anatomical awareness was 4.6 points on the average and the interest of the class was on average 4.5 points. It is expecting that 3D printing technology can enhance the learning effect of imaging anatomy education.

Experimental Study of Chemical Shift Artifacts at 1.5T and 3.0T MRI using Gradient Echo Pulse Sequence (GE 펄스시퀀스을 이용한 1.5T와 3.0T MRI의 화학적 이동 인공물의 실험적 연구)

  • Cheol, Kweon Dae
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.531-537
    • /
    • 2016
  • An experimental study was to use the parameter to determine the MRI artifact of chemical shift that occurs in water and fats. Scanning the image according to the encoding parameter and the bandwidth and change in 1.5T and 3.0T MRI to the SNR, we compared the CNR. In the image was confirmed that the occurrence of artefacts in the chemical shift of the water and oil. 3.0T more image artifacts in the 1.5T was confirmed that the relatively reduced. The width of the bandwidth it could be confirmed that according to the honeycombs artifacts decrease. Therefore, in order to reduce the artifacts in the MRI scan of the chemical shift runners weak field strength, is thought to be appropriate to widen the width of the bandwidth.

Error Analysis of General X-ray Examination by Using Simulation Training (시뮬레이션 교육을 통한 일반 X선 검사의 오류 분석)

  • Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.919-927
    • /
    • 2018
  • The purpose of this study was to present simulation training model for general X-ray examinations and to analyze the errors that occur during the simulation training. From 2012 to 2018, a total of 183 students (77 men and 106 women) participated. The simulated X-ray system used computed radiography (CR) system. The contents of simulation training were patient's care, X-ray examinations accuracy, images stability, etc. As a result, it were found that the patient's position setting error, the accuracy error of the X-ray beam central ray, the image receptor's size and setting error, the error of the grid use, the marking error, and the error of X-ray exposure technical factors. It is expected that improved practical general X-ray examinations training of radiographer will be needed, focusing on these errors, so that we could contribute to the health care of the people by providing precise examinations and high quality medical service.

Analysis of Proton Nuclear Reaction-Generated Nuclides for Different Proton Energy (양성자 에너지 변화에 따른 핵반응 생성핵종 분석)

  • Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.819-824
    • /
    • 2019
  • In this study, we proposed a method for identifying isotopes generated from high-energy proton $^{nat}Pb$(p,xn) nuclear reactions through the difference of gamma rays generated through nuclear reactions using different proton energies. The experiment was performed by using a high energy proton generated from a 100 MeV proton linear accelerator of the Korea Atomic Energy Research Institute. Gamma rays generated by various nuclides generated through proton nuclear reactions were measured using a gamma-ray spectroscopy system composed of HPGe detectors. Gamma-ray standard sources were used for accurate energy calibration and efficiency measurements of HPGe gamma-ray detectors. For the proposed method, 100 and 60 MeV proton energy beams were used for the same natural lead samples. This method was found to be very effective in identifying nuclides produced by comparing gamma rays generated from the same sample with each other. The results of this study are expected to be very effective in obtaining other proton nuclear reaction results in the future.

Monte Carlo Simulation of Transmission-Type X-ray Tube with Dual-Structured Target (이중 적층 구조 표적을 갖는 투과형 엑스선관의 몬테카를로 전산모사)

  • Kwon Su, Chon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.107-114
    • /
    • 2023
  • X-ray fluorescence analysis has been widely used in the field of science and industry because it gives information about elements and their concentrations without destruction of samples. To increase analysis accuracy of fluorescence generated by photons of the transmission-type X-ray tube for mixture and compound samples would be recommend to have strong energy near 10 keV and 20 keV simultaneously. Tungsten of 9.65 keV and molybdenum of 17.48 keV were considered as targets with dual deposition structure for obtaining two strong characteristic X-rays, and the transmission-type X-ray tube was analyzed using Geant4 Monte Carlo simulation. The W-Mo structure resulted in strong characteristic X-ray near 10 keV and 20 keV simultaneously. A structure with Mo-W multilayers of 5 ㎛ thick also gave optimal spectrum. Various material combination and thickness optimization for the dual-structured target can give X-ray spectrum with strong characteristic X-ray of specific energies.