• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.035 seconds

Evaluation of imaging reformation for root and pulp canal shapes of permanent teeth using a cone beam computed tomography (Cone beam형 전산화단층영상을 이용한 영구치 치근과 근관의 형태 평가)

  • Hong, Jong-Hyun;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.37 no.3
    • /
    • pp.165-170
    • /
    • 2007
  • Purpose: To estimate the shape of root and pulp canal using a dental cone beam computed tomography (CBCT) and to evaluate the accuracy of imaging reformation. Materials and Methods: CBCT images were obtained with incisors, premolars, and molars as the destination by using PSR $9000N^{TM}$ Dental CT system (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan) and i-CAT (Imaging Sciences International, Inc, USA) cone beam CT unit that have different kind of detector and field of view, and compared these with the shape and the size of actual root and root canal. Results: When the measuring value of cone beam computed tomography concerning to each root's bucco-lingual diameter and mesio-distal diameter was compared with the value of the actual root, it reveals an error range $-0.49{\sim}+0.63$ mm at PSR900N and $-0.97{\sim}+1.14$ mm at i-CAT (P>0.05). It was possible to identify and measure PSR$9000N^{TM}$ Dental CT system to the limit $0.48{\pm}0.06mm$ (P>0.05) and i-CAT CBCT to the limit $0.86{\pm}0.09mm$ (P<0.05) on estimating the size and the shape of root canal. Two kinds of CBCT images revealed the useful reproducibility to estimate the shape of root, but there was the difference to estimate the shape of root according to apparatus. The reproducibility of root shape in the image of three-dimensions at PSR 900N is low such as 0.65 mm in a case of minute root canal. Conclusions: CBCT images revealed higher accuracy of the imaging reformation for root and pulp and clinically CBCT is a useful diagnostic tool for the assessment of root and canal. However, there are different qualities of imaging reformation according to CBCT apparatus and limitation of reproducibility for minute root canals.

  • PDF

Evaluation of the Accuracy of Distance Measurements on 3D Volume-rendered Image of Human Skull Using Multi-detector CT: Effects of Acquisition Section Thickness and Reconstruction Section Thickness

  • Haijo Jung;Kim, Hee-Joung;Lee, Sang-Ho;Kim, Dong-Wook;Soonil Hong;Kim, Dong-Hyeon;Son, Hye-Kyung;Wonsuk Kang;Kim, Kee-Deog
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.457-460
    • /
    • 2002
  • The image quality of three-dimensional (3D) images has been widely investigated by the qualitative analysis method. A need remains for an objective and quantitative method to assess the image quality of 3D volume-rendered images. The purpose of this study was to evaluate the quantitative accuracy of distance measurements on 3D volume-rendered images of a dry human skull by using multi-detector computed tomography (MDCT). A radiologist measured five times the twenty-one direct measurement line items composed among twelve reference points on the skull surface with a digital vernier caliper. The water filled skull specimen was scanned with a MDCT according to the section thicknesses of 1.25, 2.50, 3.75, and 5.00 mm for helical (high quality; pitch 3:1) scan mode. MDCT data were reconstructed with its acquisition section thickness and with 1.25 mm section thickness for all scans. An observer also measured seven times the corresponding items on 3D volume-rendered images with measuring tools provided by volumetric analysis software. The quantitative accuracy of distance measurements on the 3D volume-rendered images was statistically evaluated (p-value < 0.05) by comparatively analyzing these measurements with the direct distance measurements. The accuracy of distance measurements on the 3D volume-rendered MDCT images acquired with 1.25, 2.50, 3,75 and 5.00 mm section thickness and reconstructed with its section thickness were 48%, 33%, 23%, and 14%, respectively. Meanwhile, there were insignificant statistical differences in accuracy of distance measurements among 3D volume-rendered images reconstructed with 1.25 mm section thickness for the each acquisition section thickness. MDCT images acquired with thick section thickness and reconstructed with thin section thickness in helical scan mode should be effectively used in medical planning of 3D volume-rendered images. The quantitative analysis of distance measurement may be a useful tool for evaluating the quantitative accuracy and the defining optimal parameters of 3D volume-rendered CT images.

  • PDF

Pierre Robin sequence with severe scoliosis in an adult: A case report of clinical and radiological features

  • Kim, Jae-Jun;Choi, Dong-Soon;Jang, Insan;Cha, Bong-Kuen;Park, In-Woo
    • Imaging Science in Dentistry
    • /
    • v.49 no.4
    • /
    • pp.323-329
    • /
    • 2019
  • Pierre Robin sequence (PRS) is characterized by the triad of micrognathia, glossoptosis, and airway obstruction. PRS does not have a single pathogenesis, but rather is associated with multiple syndromes. This report presents the case of a 35-year-old woman with PRS and scoliosis. Among the syndromes related to PRS, cerebro-costo-mandibular syndrome (CCMS), which is characterized by posterior rib gap defects and vertebral anomalies, was suspected in this patient. However, no posterior rib gap defect was detected on radiological examinations. Although over 80 cases of CCMS have been reported to date, few cases of PRS with scoliosis alone have been reported. Therefore, this report demonstrated the clinical, radiological, and cephalometric characteristics of an adult patient with PRS and scoliosis, but without rib anomalies.

A deep learning approach to permanent tooth germ detection on pediatric panoramic radiographs

  • Kaya, Emine;Gunec, Huseyin Gurkan;Aydin, Kader Cesur;Urkmez, Elif Seyda;Duranay, Recep;Ates, Hasan Fehmi
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.275-281
    • /
    • 2022
  • Purpose: The aim of this study was to assess the performance of a deep learning system for permanent tooth germ detection on pediatric panoramic radiographs. Materials and Methods: In total, 4518 anonymized panoramic radiographs of children between 5 and 13 years of age were collected. YOLOv4, a convolutional neural network (CNN)-based object detection model, was used to automatically detect permanent tooth germs. Panoramic images of children processed in LabelImg were trained and tested in the YOLOv4 algorithm. True-positive, false-positive, and false-negative rates were calculated. A confusion matrix was used to evaluate the performance of the model. Results: The YOLOv4 model, which detected permanent tooth germs on pediatric panoramic radiographs, provided an average precision value of 94.16% and an F1 value of 0.90, indicating a high level of significance. The average YOLOv4 inference time was 90 ms. Conclusion: The detection of permanent tooth germs on pediatric panoramic X-rays using a deep learning-based approach may facilitate the early diagnosis of tooth deficiency or supernumerary teeth and help dental practitioners find more accurate treatment options while saving time and effort

Dose Reduction and Image Quality Assessment of the CareDose 4D Technique on Abdomen Liver Computed Tomography (복부 간 CT 검사에서 CareDose 4D 사용에 따른 선량 감소 및 화질 평가)

  • Seok, Jong-Min;Jeon, Woo-Jin;Park, Young-Joon;Lee, Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.109-115
    • /
    • 2017
  • The purpose of this study was to evaluate the clinical efficacy of 128 MDCT (multi-detector computed tomography) for reducing the CareDose 4D dose and comparing the image quality with the fixed tube current technique. For this purpose, we conducted the phantom and clinical studies to evaluate the exposure dose and image of the subject before and after applying the CareDose 4D system in abdominal examination using 128 MDCT. In the phantom study, ROI (Region of interest) was located at the center, 3, 6, 9, 12 o'clock, into two groups: group A without CareDose 4D and Group B applied were measured. In the clinical study, ROI was located at the liver 8 segments, divided into two groups too. The measured items were CT number, noise, and dose length product (DLP) dose. The result of CTDIvol (CT Dose Index volume) measurements in phantom and clinical studies were lower than those before CareDose 4D application, and dose and effective dose were also measured lower (p<.05). There was no difference in CT number before and after application (p>.05). In conclusion, using CareDose 4D, we can obtain optimal image information without deteriorating image quality while reducing patient dose.

A Study on the Diagnosis of Urinary Stone Location by Abdominal Positioning Variations (요로결석 위치 진단에 대한 복부자세 변화에 따른 연구)

  • Kim, Dong-Jin;Chae, Jong-Sang;Yoo, Chae-Min;Lee, Bae-Won
    • Journal of radiological science and technology
    • /
    • v.41 no.1
    • /
    • pp.7-12
    • /
    • 2018
  • Patients who visit the emergency room with urinary stones have difficulty lying down in a supine position due to severe pain when performing the KUB test. The purpose of this study was to find methods to reduce the patients' pain and image distortion, and obtain medical images with high diagnostic values. After checking the standard classification of disease and cause of death, the target group consisted of 121 patients who had clearly distinguished stones from computed tomography. Patients with stones in the ureteralvesical junction were excluded. Qualitative image evaluation was performed by confirming the location of the stone in the computed tomography images. and evaluated the rate of visual discrimination of stones possible through KUB and abdominal plain X-ray. Quantitative image evaluation was performed on the KUB, abdominal plain X-ray images. The transverse process of the first lumbar vertebrae served as the standard point, and the length from this point to the lower part of the stone was measured. Results from looking at the rate of visual discrimination of stones possible through KUB and abdominal plain X-ray showed: 94 patients (77.6%) for KUB images and 91 patients (75.2%) for computed tomography images. The standard deviation for KUB and abdominal X-ray was 3 (2.4%). Comparing and analyzing the location from KUB images and abdominal plain X-ray images, the stone position was 10.1 mm in the kidney, 10.5 mm in the ureteropelvic junction, and 9.7 mm in the ureters. It was shown that the stone moved 10 mm on average with significant statistical difference (P<0.05). In cases where the pain is so severe that it is impossible to perform the test in the supine position, an alternative may be to check the stone position by performing a modified KUB test by having the patient stand in a vertical position. In the future, this will provide convenience to both the examiner and the patient when performing the examination, and it will contribute with its reproducibility.

Correlation of the Neuropsychological Screening Battery (NSB) and Neuroanatomy for the Parkinson's Disease with Mild Cognitive Impairment by Using the Analysis of Cerebral Cortex Thickness in the Brain MRI (뇌 자기공명영상에서 대뇌 피질 두께 분석법을 이용한 파킨슨병의 경도인지장애 신경심리검사와 신경해부학적 상관관계)

  • Lee, Hyeonyong;Park, Hyonghu;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.163-170
    • /
    • 2014
  • This study is to investigate neuro-anatomical correlation between neuropsychological results and cerebral cortex thickness of cognitive ability in the brain MRI targeting the patients with mild cognitive impairment. It was that 78 people who were diagnosed as first Parkinson's disease followed by neuropsychological screening battery(Parkinson's disease with mild cognitive impairment: 39 people; Parkinson's disease with normal cognition: 39 people) and 32 people of normal group were selected. Correlation between mild cognitive impairment and normal cognitive impairment and correlation between neuropsychological screening battery and cerebral cortex thickness in the brain MRI were performed by independent sample t-test or Pearson correlation coefficient and then level of significance of collected data was verified in p<0.05. As a result, cerebral cortex thickness of the Parkinson's disease with mild cognitive impairment in both side precuneas and right inferiortemporal lobe had statistically significant decrease. In addition, function of visuospatial ability, verbal and visual memory was reduced in neuropsychological screening battery for cognitive assessment. Especially, there was correlation between neuropsychological screening battery of verbal and visual memory anatomical left precuneus.

Job Competency in Ultrasonography of Korean Radiological Technologists (한국 방사선사의 초음파진단검사 직무역량에 관한 고찰)

  • Lim, Chang Seon;Kim, Chuk Bok;Namkung, Jang Sun;Jin, Gye Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.857-864
    • /
    • 2019
  • Many countries, including Canada, operate a sonographer license system separately from a radiological technologist license. However, in Korea, radiological technologists perform ultrasound imaging under the guidance of doctors. Therefore, in order to have the opportunity to provide a systematic education by analyzing the job competency of the radiological technologist's ultrasound imaging, based on the Canadian National Competency Profile (NCP) lists, this study measured the job content validity of the job competences and detailed competencies required for performing ultrasonography in Korea. From the results of comparing and analyzing the importance of the core competencies included in the Korean radiological technologist's job competencies and the degree of job performance, the average overall importance was 4.087, the average of overall performance was 3.640, showing that the importance was higher than the performance and that there was a statistically significant difference. In conclusion, 'A Communication', 'B Professional responsibilities', 'D Operation of equipment' and 'G Workplace health and safety' showed high job content validity. However, it is said that as 'C Patient assessment and care', 'E Critical thinking and problem solving', and 'H Image' showed low job content validity, it is necessary to seek ways to strengthen and complement these competencies.

Ultrasound-Guided Percutaneous Biopsy With Needle Track Plugging in Patients With Focal Liver Lesions on an Outpatient Basis: A Randomized Controlled Trial

  • Ja Kyung Yoon;Choong-kun Lee;Hongjeong Yoon;Hye Jin Choi;Seung-seob Kim
    • Korean Journal of Radiology
    • /
    • v.25 no.10
    • /
    • pp.902-912
    • /
    • 2024
  • Objective: The increasing utilization of various molecular tests for diagnosing and selecting treatments for patients with malignancies has led to a rising trend in both the frequency of biopsies and the required tissue volume. We aimed to compare the safety of outpatient ultrasound (US)-guided percutaneous liver biopsy (PLB) between the coaxial method with needle track plugging (NTP) and the conventional method. Materials and Methods: This single-center, prospective, randomized controlled study was conducted from October 2022 to May 2023. Patients referred for US-guided PLB with target liver lesions measuring ≥1 cm and requiring ≥3 tissue cores were enrolled. Patients with severe coagulopathy or a substantial volume of ascites were excluded. Patients were randomly assigned to undergo PLB using either the coaxial method with NTP or the conventional method, in a 1:1 ratio, and were subsequently discharged after 2 hours. The primary endpoint was the presence of a patent track sign, defined as a linear color flow along the biopsy track on Doppler US, as an indication of bleeding. The secondary endpoints included clinically significant bleeding, delayed bleeding after discharge, and diagnostic yield. The incidences of these endpoints were compared between the two methods. Results: A total of 107 patients completed the study protocol. Patent track signs were observed significantly less frequently in the coaxial method with NTP group than in the conventional method group: 16.7% (9/54) vs. 35.8% (19/53; P = 0.042). Clinically significant bleeding and delayed bleeding did not occur in either group, and both methods achieved a high diagnostic yield: 94.4% (51/54) vs. 98.1% (52/53; P = 0.624). Conclusion: Compared with the conventional method, the coaxial method with NTP may potentially be safer, with a reduced risk of overall bleeding complications after PLB when retrieving ≥3 tissue cores. The coaxial method with NTP could be considered a viable option for acquiring multiple liver tissues on an outpatient basis.

Study on the Radiation Dose about Skin Thickness of Rat (For Radiation Damage Tissue Engineering) (쥐의 피부두께에 따른 선량연구)

  • Jung, Hongmoon;Won, Doyeon;Kim, Hyeongyun;Jung, Jaeeun;Choi, hyeun-woo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.375-379
    • /
    • 2016
  • A rat is the most common experimental animal used for the realization of the radiation injury model. The certain thickness of rat skin was prepared by peeling off a rat skin. Radiation level was measured by using this rat skin. Also, The schematic of the formula was made that can predict the radiation absorbed dose (RAD) as a function of the thickness of the rat skin. Consequently, we will provide the RAD information in the realization of in-vitro experimental model regarding the rat's skin thickness by applying the formulas. Moreover, the results from this study can be effectively used for the in-vitro experiment of the rat subcutaneous tissue which was exposed to radiation.