• Title/Summary/Keyword: Radiology practice

Search Result 297, Processing Time 0.024 seconds

Free-Breathing Motion-Corrected Single-Shot Phase-Sensitive Inversion Recovery Late-Gadolinium-Enhancement Imaging: A Prospective Study of Image Quality in Patients with Hypertrophic Cardiomyopathy

  • Min Jae Cha;Iksung Cho;Joonhwa Hong;Sang-Wook Kim;Seung Yong Shin;Mun Young Paek;Xiaoming Bi;Sung Mok Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.7
    • /
    • pp.1044-1053
    • /
    • 2021
  • Objective: Motion-corrected averaging with a single-shot technique was introduced for faster acquisition of late-gadolinium-enhancement (LGE) cardiovascular magnetic resonance (CMR) imaging while free-breathing. We aimed to evaluate the image quality (IQ) of free-breathing motion-corrected single-shot LGE (moco-ss-LGE) in patients with hypertrophic cardiomyopathy (HCM). Materials and Methods: Between April and December 2019, 30 patients (23 men; median age, 48.5; interquartile range [IQR], 36.5-61.3) with HCM were prospectively enrolled. Breath-held single-shot LGE (bh-ss-LGE) and free-breathing moco-ss-LGE images were acquired in random order on a 3T MR system. Semi-quantitative IQ scores, contrast-to-noise ratios (CNRs), and quantitative size of myocardial scar were assessed on pairs of bh-ss-LGE and moco-ss-LGE. The mean ± standard deviation of the parameters was obtained. The results were compared using the Wilcoxon signed-rank test. Results: The moco-ss-LGE images had better IQ scores than the bh-ss-LGE images (4.55 ± 0.55 vs. 3.68 ± 0.45, p < 0.001). The CNR of the scar to the remote myocardium (34.46 ± 11.85 vs. 26.13 ± 10.04, p < 0.001), scar to left ventricle (LV) cavity (13.09 ± 7.95 vs. 9.84 ± 6.65, p = 0.030), and LV cavity to remote myocardium (33.12 ± 15.53 vs. 22.69 ± 11.27, p < 0.001) were consistently greater for moco-ss-LGE images than for bh-ss-LGE images. Measurements of scar size did not differ significantly between LGE pairs using the following three different quantification methods: 1) full width at half-maximum method; 23.84 ± 12.88% vs. 24.05 ± 12.81% (p = 0.820), 2) 6-standard deviation method, 15.14 ± 10.78% vs. 15.99 ± 10.99% (p = 0.186), and 3) 3-standard deviation method; 36.51 ± 17.60% vs. 37.50 ± 17.90% (p = 0.785). Conclusion: Motion-corrected averaging may allow for superior IQ and CNRs with free-breathing in single-shot LGE imaging, with a herald of free-breathing moco-ss-LGE as the scar imaging technique of choice for clinical practice.

Controversies about Radioactive Iodine-131 Remnant Ablation in Low Risk Thyroid Cancers: Are We Near A Consensus?

  • Zaman, Maseeh Uz;Fatima, Nosheen;Padhy, Ajit Kumar;Zaman, Unaiza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.11
    • /
    • pp.6209-6213
    • /
    • 2013
  • Well differentiated thyroid cancers (WDTC), including papillary (80%) and follicular (10%) types, are the most common endocrine cancers globally. Over the last few decades most the diagnosed cases have fallen into low risk categories. Radioactive iodine-131 (RAI) has an established role in reducing recurrence and improving the survival in high risk patients. In patients with primary tumor size <1 cm, RAI is not recommended by many thyroid societies. However, low risk WDTC has been an arena of major controversies, most importantly the role and dose of adjuvant RAI for remnant ablation to minimize chances of recurrence and improving survival. This review is an attempt to update readers about the previous and existing practice based on results of non-randomized trials and evolving trends fueled by recently published randomized studies.

Frequently Asked Questions in the Interpretation of Preoperative and Postoperative Chest CT Scans Related to Lung Cancer Imaging

  • Lee, Kyung-Soo
    • 대한핵의학회:학술대회논문집
    • /
    • 2002.05a
    • /
    • pp.25-27
    • /
    • 2002
  • With the advent of multidetector-row CT, lung cancer imaging is much more promising than before. However, the effectiveness of multidetector-row CT in making an initial diagnosis, staging, and evaluating post-treatment changes of lung cancer still remains to be proved. Fast imaging along with volumetric data set and attendant multi-planar imaging provide much more details on the anatomic changes and pathology associated with lung cancer. However, with images showing anatomic and pathologic changes only, radiologists confront with several questions the answers of which may help evaluate lung cancer more thoroughly. The frequent questions that I have in dally practice of chest CT interpretation are as follows.

  • PDF

Hypofractionated whole breast irradiation: new standard in early breast cancer after breast-conserving surgery

  • Kim, Kyung Su;Shin, Kyung Hwan;Choi, Noorie;Lee, Sea-Won
    • Radiation Oncology Journal
    • /
    • v.34 no.2
    • /
    • pp.81-87
    • /
    • 2016
  • Hypofractionated whole breast irradiation (HF-WBI) has been proved effective and safe and even better for late or acute radiation toxicity for early breast cancer. Moreover, it improves patient convenience, quality of life and is expected to be advantageous in the medical care system by reducing overall cost. In this review, we examined key randomized trials of HF-WBI, focusing on adequate patient selection as suggested by the American Society of Therapeutic Radiology and Oncology (ASTRO) guideline and the radiobiologic aspects of HF-WBI in relation to its adoption into clinical settings. Further investigation to identify the current practice pattern or cost effectiveness is warranted under the national health insurance service system in Korea.

Rhinolith: An incidental radiographic finding

  • Maheshwari, Nisha;Etikaala, Badirinath;Syed, Ali Z.
    • Imaging Science in Dentistry
    • /
    • v.51 no.3
    • /
    • pp.333-336
    • /
    • 2021
  • Rhinoliths are foreign bodies composed of mineralised deposits in the nasal cavity that are rarely encountered in routine dental practice. The current report presents a case of a 77-year-old female patient who visited a dental treatment centre for a routine dental check-up and prophylaxis. On the clinical examination, the patient did not report any breathing difficulty, nasal obstruction, or any form of discharge. Panoramic radiography showed a horizontally magnified radiopaque structure in the right nasal fossa region. Cone-beam computed tomography (CBCT) revealed a hyperdense entity with a laminated presentation in the right nasal fossa. The hyperdense entity was diagnosed as a rhinolith based on the radiographic findings. Although the patient was asymptomatic, a referral was made to an ear, nose, and throat surgeon for a further evaluation. This report highlights the importance of CBCT imaging in the diagnosis of soft-tissue calcifications.

Korean Clinical Practice Guidelines for Aneurysmal Subarachnoid Hemorrhage

  • Cho, Won-Sang;Kim, Jeong Eun;Park, Sukh Que;Ko, Jun Kyeung;Kim, Dae-Won;Park, Jung Cheol;Yeon, Je Young;Chung, Seung Young;Chung, Joonho;Joo, Sung-Pil;Hwang, Gyojun;Kim, Deog Young;Chang, Won Hyuk;Choi, Kyu-Sun;Lee, Sung Ho;Sheen, Seung Hun;Kang, Hyun-Seung;Kim, Byung Moon;Bae, Hee-Joon;Wan, Chang;Park, Hyeon Seon
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.2
    • /
    • pp.127-166
    • /
    • 2018
  • Despite advancements in treating ruptured cerebral aneurysms, an aneurysmal subarachnoid hemorrhage (aSAH) is still a grave cerebrovascular disease associated with a high rate of morbidity and mortality. Based on the literature published to date, world-wide academic and governmental committees have developed clinical practice guidelines (CPGs) to propose standards for disease management in order to achieve the best treatment outcomes for aSAHs. In 2013, the Korean Society of Cerebrovascular Surgeons issued a Korean version of the CPGs for aSAHs. The group researched all articles and major foreign CPGs published in English until December 2015 using several search engines. Based on these articles, levels of evidence and grades of recommendations were determined by our society as well as by other related Quality Control Committees from neurointervention, neurology and rehabilitation medicine. The Korean version of the CPGs for aSAHs includes risk factors, diagnosis, initial management, medical and surgical management to prevent rebleeding, management of delayed cerebral ischemia and vasospasm, treatment of hydrocephalus, treatment of medical complications and early rehabilitation. The CPGs are not the absolute standard but are the present reference as the evidence is still incomplete, each environment of clinical practice is different, and there is a high probability of variation in the current recommendations. The CPGs will be useful in the fields of clinical practice and research.

Three-dimensional comparison of 2 digital models obtained from cone-beam computed tomographic scans of polyvinyl siloxane impressions and plaster models

  • Park, Jin-Yi;Kim, Dasomi;Han, Sang-Sun;Yu, Hyung-Seog;Cha, Jung-Yul
    • Imaging Science in Dentistry
    • /
    • v.49 no.4
    • /
    • pp.257-263
    • /
    • 2019
  • Purpose: This study was performed to evaluate the dimensional accuracy of digital dental models constructed from cone-beam computed tomographic (CBCT) scans of polyvinyl siloxane (PVS) impressions and cast scan models. Materials and Methods: A pair of PVS impressions was obtained from 20 subjects and scanned using CBCT (resolution, 0.1 mm). A cast scan model was constructed by scanning the gypsum model using a model scanner. After reconstruction of the digital models, the mesio-distal width of each tooth, inter-canine width, and inter-molar width were measured, and the Bolton ratios were calculated and compared. The 2 models were superimposed and the difference between the models was measured using 3-dimensional analysis. Results: The range of mean error between the cast scan model and the CBCT scan model was -0.15 mm to 0.13 mm in the mesio-distal width of the teeth and 0.03 mm to 0.42 mm in the width analysis. The differences in the Bolton ratios between the cast scan models and CBCT scan models were 0.87 (anterior ratio) and 0.72 (overall ratio), with no significant difference (P>0.05). The mean maxillary and mandibular difference when the cast scan model and the CBCT scan model were superimposed was 53 ㎛. Conclusion: There was no statistically significant difference in most of the measurements. The maximum tooth size difference was 0.15mm, and the average difference in model overlap was 53 ㎛. Digital models produced by scanning impressions at a high resolution using CBCT can be used in clinical practice.

Analysis of Hospital Infection Control Awareness of Hospital Health Care Workers in Busan (부산지역 의료종사자들의 병원감염관리 인식 분석)

  • Seo, Min-Jung;Kim, Chang-Soo;Ye, Soo-Young;Kim, Jung-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.351-358
    • /
    • 2016
  • This study surveyed the health professionals in Busan with regard to their awareness of nosocomial infection control. According to the conclusion of this study, first, the level of awareness and performance of personal hygiene management, equipment sanitation management, and cleaning and environmental management increased as the level of education decreased. Also, when it comes to personal hand-washing, the level of awareness was higher among workers in primary, secondary and other medical institutions, where as the level of performance was higher among the group of medical practitioners. The differences were statistically significant at a significance level of .001. Medical practitioners also showed a higher level of awareness and performance of hospital sanitation management, which was statistically significant. Overall, as the level of awareness was lower than the level of performance, it seems that individuals need to thoroughly practice infection control, and realistic improvement measures need to be devised.

Observation of Liver Color Scan (Liver Color Scan에 대(對)한 고찰(考察))

  • Choe, Y.K.;Ahn, S.B.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.3 no.2
    • /
    • pp.55-63
    • /
    • 1969
  • In the past few years, scintigraphy has become increasingly important in clinical practice, and the use of a color-printing technique has permited a more accurate interpretation of the scan image. Our liver color scintigrams consist of 51 hepatomas, 35 liver cirrhosis, 22 liver abscessis, 10 hepatitis and other 13 cases of the liver diseases which were clinically arid pathologically diagnosed at Sevarance Hospital, Yonsei Univ., since Feb. 1969 through Sept. 1969. These scintigrams have been analized in terms of various pathologic morphology, such as size, shape, margin of the liver, distribution of radioactivity, and shape of the space occupying lesions. The results are as follows: 1. Enlargement of the liver was the most common finding in the diseased livers. The Rt. lobe enlargement was particularly prominent in the liver abscess. 2. Irregular distribution of radioactivity in the liver (so called mottling) was present in 78% of hepatoma, while it was seen only in 31% of liver abscesses. 3. Liver cirrhosis tends to show perihilar accumulation of the isotope (57%). 4. The deformity of the lower most angle of the Rt. lobe, and the Lt. lateral margin of the Lt. lobe was also impressive throughout the cases ($74{\sim}95%$ of all diseased livers). 5. The frequency of visualization of the spleen was influenced by the size of space occupying lesions and the amount of functioning liver. 6. Differentiation between the liver abscess and hepatoma seems to be possible on scintigram, when shape and margin of defect and patterns of distribution of radioactivity in the remaining liver are clearly demonstrated.

  • PDF

Development of Open Clinical Training Program to Improve Radiology-Major Students' Clinical Competency (방사선(학)과 재학생의 임상적응 향상을 위한 개방형 임상실습 프로그램의 제안)

  • Kim, Seon-Chil
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.193-201
    • /
    • 2010
  • This study aimed to develop an open clinical training program to improve radiology graduates' clinical competency in the hospital setting to raise quality of patient-centered medical service. Development of the training program is similar to that of an instructional system design model. The program was developed according to the ADDIE model. Elements of each phase were collected. Draft of the program was constructed from literature review and clinical demands. Preliminary training program was implemented to sample students with the draft. After consultation with related professionals, the program was modified and completed. Professional groups assessed content validity of the program. Five continuous phases of the program - analysis, design, development, implementation, and evaluation - accommodate changes in clinical environment and demands. They also provide adequate learning needs. Effectiveness of the program and appropriateness of contents in each phase achieved a satisfactory level of significance. This program reflected demands from medical fields and effective learning programs. The purpose of the open clinical training program is to train radiological technologists in clinical setting to actively engage in patient-centered medical service and to help utilize their professional knowledge.