Journal of the Korea Academia-Industrial cooperation Society
/
v.11
no.12
/
pp.4819-4825
/
2010
In all of dental ceramics, these materials contained the radio-isotopes with natural abundance ratio. After dental treatment, remained dental ceramics in the oral cavity is caused for human internal dose. In this study, the gross beta activity levels were measured in dental materials including 22 dental ceramics, 1 resin, and 2 cements for estimation of human internal dose. In dental ceramic samples, the obtained results showed that the gross beta activity level varied between 1.317 ~ 2.935 Bq/g and the gross beta activity level was 2.379 Bq/g. And the same level for dentine, opacious dentine, translucent and enamel were 2.479 Bq/g, 2.491 Bq/g, 2.470 Bq/g and 2.069 Bq/g, respectively. The gross beta activity level of temporary resin and cements were negligible, compare to the same level of dental ceramics. The high gross beta activity level observed in opacious dentine code OD-A4 is 2.935 Bq/g thus mainly ascribable to 40K. The reduction of the radiation level of natural radio-isotopes and the improvement of the dental ceramic materials should be required for internal dose reduction.
Although magnetic resonance imaging without linear hardening of CT is recognized as a method of obtaining high contrast of tissue and excellent resolution image in brain disease and head and neck examination, magnetic susceptibility artifact is generated in case of metal implants in the oral cavity, which is an obstacle to image diagnosis. Therefore, an effort was made in this thesis to find a method to reduce artifacts caused by dental implants and prosthesis in MRI. Implant-induced artifacts in magnetic resonance imaging showed that the signal size increased with shorter TE in GE technique and was inconsistent with water temperature change. In SE technique as well, the signal size of water was generally higher than that of air, but the signal to noise ratio (SNR) was not different by air and temperature. In EPI technique, images with fewer artifacts were obtained quantitatively and qualitatively when there was more water than air, and the signal to noise ratio was measured the highest, especially at water temperatures of 20° and 30°. In conclusion, when examining using the EPI technique rather than the SE or the GE technique, obtaining brain diffusion using a 20° and 30° water bag reduces the magnetic susceptibility artifacts caused by implants and prosthesis, suggesting that it may provide images with high diagnostic value.
Purpose: To review the clinical and radiological results after an open reduction and internal fixation with a T-shaped LCP for unstable distal clavicle fractures. Materials and Methods: From February 2005 to June 2006, ten patients with distal clavicle Neer type II fractures were treated with an open reduction and internal fixation with a T-shaped LCP. Bony union was identified by plain radiography. The clinical results were analyzed according to the UCLA scoring system. Results: The mean time to fracture union was 9weeks and union was achieved in all cases. The mean UCLA score was 33.4 (30-35); excellent in 8 cases and good in 2 cases. In one case, loosening of one distal screw was occured and mild AC joint subluxation was observed in another case. Conclusion: 3.5 mm T-shaped LCP fixation is a useful technique for treating unstable distal clavicle fractures. This procedure provide stable fixation with no further AC joint injury.
Objective : The purpose of this study was to evaluate the clinical and radiological results after treatment of old ACL(anterior cruciate ligament) avulsion fracture of tibia. Materials and Method : 11 cases who were followed up at least 2 years after treatment in chronic ACL avulsion fracture of tibia were included in this study. The average age of patients was 26(9-66) years and the mean period of follow up was 53(24-131) months. After evaluation of the lesion and treatment of associated lesion under arthroscope, open reduction and internal fixation or fragment removal was performed. Pull-out suture was performed in 8 cases, screw fixation in 2 cases. Results : The Lysholm knee score was 64.3 in average preoperatively and improved to 96.2 average at follow up. On the Lachman test, there were mild(+) instabilities in 7 cases, moderate(++) in 4 cases. On the postoperative Lachman test, there were no instabilities in 9 cases, mild(+) instabilities in only 2 cases. According to Meyers and Mckeever's evaluation protocol, 9 cases $(81.8\%)$ were excellent, 2 case $(18.2\%)$, good. On preoperative instrumented anterior laxity test with $Telos^{\circledR}$, side to side difference in 201b was 7.8(10-4) min in average and 2.1(6-0) mm in average at follow-up. Conclusion : In chronic ACL avulsion fracture, it is thought that combination of arthroscopic evaluation of associated injury and open reduction and fixation and fragment removal can bring about satisfactory results.
Journal of the Korean Association of Oral and Maxillofacial Surgeons
/
v.27
no.5
/
pp.428-434
/
2001
After miniplate fixation of mandibular angle fractures, fracture line stability during functional loading was evaluated. Using panoramic radiographs, 15 mandibular angle fracture patients who were treated by open reduction and one miniplate fixation along the external oblique ridge, were evaluated at postoperative 1, 4 and 8 weeks. At each time, 2 radiographs were taken: one taken during maximum biting of hardened silicone sheet on the affected side molar area and the other on the non-affected side. The distraction gap of inferior border of mandible at each time and each side was measured and these data were analysed statistically with clinical findings. The differences of inferior border distraction gap during hardened silicone sheet biting on the affected side molar area and on the non-affected side molar area at 4 week radiographs were smaller than those of 1 week's except one case. At 8 week's radiographs, the fracture lines were so stabilized that it was almost impossible to find the gap differences except one case and there were increased radiopacity along the entire fracture lines. Clinically, bony union was confirmed in all cases during plate removal performed at postoperative 6 month. By statistical analysis(paired t-test), the inferior border distraction gap during biting of hardened silicone sheet on the affected side was significantly reduced during 1 and 4 week interval(p<0.01). The differences of inferior border distraction gap during biting on the affected side molar area and on the non-affected side molar area were also significantly reduced at 1 and 4 week interval(p<0.01). But the inferior border distraction(compression) gap during non-affected side biting was not significantly changed. From these findings, it could be concluded that fracture line stability during functional loading after one miniplate fixation of mandibular angle fractures stems mainly from reduction of inferior border distraction gap during affected side biting on time interval. According to these radiographic and clinical findings, the clinical superiority of one miniplate fixation technique in mandibular angle fracture treatment could be confirmed.
Fracture of frontal bone is infrequent, but may have serious complications because of their proximity to the brain, eyes and noses. Fractures of the frontal area range from 5% to 15% of all facial bone fracture and include supraorbital rim and frontal sinus. As frontal bone fractures most frequently occur in the multiply injured patient, a thorough clinical and radiological examination of the patient is required before diagnosis and treatment plans are established. Sometimes coorperative treatment with other department is required. It is specially considered that incision for access to frontal region and surgical methods for open reduction, cranialization, cannulization, sinus obliteration. After surgical or conservative treatment, it may have complication. Complication of frontal bone injury vary in severity and may occur at several years after the incidents. The major types of complications are those that occur directly at the time of injury, infection and chronic problems. This is clinical study on 31 patients with frontal bone fracture, at department of oral and maxillofacial surgery in dental hospital of Wonkwang university during past ten years. The results were as follows; 1. The sex ratio of all patients is 29 (94%) male to 2 (6%) female, the average age is 33 and the prominent groups are 2nd, 3rd decade age. 2. The causative factors are mostly traffic accident 22 cases (70%) and fall dawn, industrial accidents, so on. 3. The 17 cases has shown alert mental status, but neurologic problems is in 14 (45%) cases in initial accessment. 4. Associated facial bone fractures are prominent in the maxilla (42%) and panfacial fracture (39%). 5. Involved general problems are in department of neurologic surgery problems (65%), orthopaedic problems (23%) and ophthalmologic problems (19%) in order. 6. Open reduction has done in 15 cases and 16 cases with conservative management. 7. Postoperative complications are chronic headache (42%), esthetic problems (39%) and ophthalmologic problems (35%)in order.
This study aims to find out geometric parameters which practitioner adjustable to reduce dose in coronary angiography. We take fluoroscopy and cine exposure by use of phantom, and got dose use the dose-area product(DAP) meter of angiography device, than convert DAP to effective dose. As results, Cine exposure shows higher dose measurement about 6-7 times than fluoroscopy. Dose in frame per second(FPS) mode could be decrease down to 70%, as lower FPS. In view of X-ray tube angle, LAO $45^{\circ}$+Caudal $30^{\circ}$ shows highest dose measurement. More use of Collimator, lower dose measurement. Source-image intensifier distance(SID) get longer to 10cm, dose of each fluoroscopy and cine exposure increase up to 25-30%. Image magnification of field of view(FOV) could increase dose up to 1.21-2 times. Also table-image intensifier distance get longer to 10cm, dose increased 1.11-1.25 times. Practitioner can adjust several geometric parameters, as FPS mode, tube angle, Collimation, SID, table-image intensifier distance, FOV. And each factors can reduce radiation dose in coronary angiography.
This paper is to establish a basis for a dose reduction strategy by confirming correlations with the factors that may affect the radiation dose based on the dose records in low-dose chest CT and abdominal non-contrast CT. In order to find out the causes of unnecessary exposure, the correlation between seven factors (age, gender, height, weight, BMI, patient status [inpatient and outpatient], and use of dose modulation) and CT dose were identified. Logistic regression was used as the statistical analysis for correlation verification. In the low dose chest CT, as the higher values of height and BMI and dose modulation off were associated with lowering the risk exceeding Diagnostic Reference Levels(DRL) (odds ration<1, p<0.05). However, as woman compared to man and the higher values of weight were associated with highering the risk exceeding DRL (odds ration>1, p<0.05). In the abdomen CT, as dose modulation off were associated with lowering the risk exceeding DRL (odds ration<1, p<0.05). Therefore It is necessary to conduct research on the relationship between various factors affecting radiation exposure and patient radiation dose for reducing the dose.
Sparse-view computed tomography (CT) imaging technique is able to reduce radiation dose, ensure the uniformity of image characteristics among projections and suppress noise. However, the reconstructed images obtained by the sparse-view CT imaging technique suffer from severe artifacts, resulting in the distortion of image quality and internal structures. In this study, we proposed a convolutional neural network (CNN) with wavelet transformation and residual learning for reducing artifacts in sparse-view CT image, and the performance of the trained model was quantitatively analyzed. The CNN consisted of wavelet transformation, convolutional and inverse wavelet transformation layers, and input and output images were configured as sparse-view CT images and residual images, respectively. For training the CNN, the loss function was calculated by using mean squared error (MSE), and the Adam function was used as an optimizer. Result images were obtained by subtracting the residual images, which were predicted by the trained model, from sparse-view CT images. The quantitative accuracy of the result images were measured in terms of peak signal-to-noise ratio (PSNR) and structural similarity (SSIM). The results showed that the trained model is able to improve the spatial resolution of the result images as well as reduce artifacts in sparse-view CT images effectively. Also, the trained model increased the PSNR and SSIM by 8.18% and 19.71% in comparison to the imaging model trained without wavelet transformation and residual learning, respectively. Therefore, the imaging model proposed in this study can restore the image quality of sparse-view CT image by reducing artifacts, improving spatial resolution and quantitative accuracy.
Nam-Kung, Sik;Kim, Ji Hyeon;Lee, Ju young;Park, Hoon Hee
The Korean Journal of Nuclear Medicine Technology
/
v.17
no.1
/
pp.36-42
/
2013
Purpose: Recently with CT developed, various studies for reduction of exposure dose is underway. Study of bismuth shields in these studies is actively underway, and has already been applied in the clinical. However, the application of the PET/CT examination was not activated. Therefore, through this study, depending on the application of bismuth shields in the PET/CT examination, we want to identify the quality of the image and the impact on the SUV. Materials and Methods: In this study, to apply to the shielding of the breast, by using the bismuth shields that contains 0.06 mmPb ingredients, was applied to the PET/CT GEMINI TF 64 (Philips Healthcare, Cleveland, USA). Phantom experiments using the NEMA IEC Body Phantom, images were acquired according to the presence or absence of bismuth shields apply. Also, When applying, images were obtained by varying the spacing 0, 1, 2 cm each image set to the interest range in the depth of the phantom by using EBW-NM ver.1.0. Results: When image of the PET Emission acquires, the SUV was in increased depending on the use of bismuth shields, difference in the depth to the surface from deep in the phantom increasingly SUV increased (P<0.005). Also, when using shields, as the more gab decreased, SUV is more increased (P<0.005). Conclusion: Through this study, PET/CT examination by using of bismuth shields which is used as purpose of reduction dose be considered. When using shields, the difference of SUV resulting from the application of bismuth shields exist and that difference is more decreased as gab of shields and surface is wider. Therefore, setting spacing of shield should be considered, if considering the reduction of the variation of SUV and image quality, disease of deep or other organs should be a priority rather than superficial disease. Through this study, when applying identified to clinical examination, the reduction of unnecessary exposure is considered.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.