• Title/Summary/Keyword: Radiological Inventory

Search Result 16, Processing Time 0.02 seconds

Assessment of the Radiological Inventory for the Reactor at Kori NPP Using In-Situ Measurement Technology (In-Situ 측정법을 이용한 고리 원자로 방사선원항 평가)

  • Jeong, Hyun Chul;Jeong, Sung Yeop
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.2
    • /
    • pp.171-178
    • /
    • 2014
  • After the expiration of operating license of a plant, all infrastructures within the plant must be safely dismantled to the point that it no longer requires measures for radiation protection. Despite the fact that Kori 1 and Wolsong 1 are close to the expiration of their operating license, sufficient technologies for radiological characterization, decontamination and dismantling is still under development. The purpose of this study is to develop one of methods for radiological inventory assessment on measuring object by using direct measure of large component with In-Situ measurement technique. Radiological inventory was assessed by analyzing nuclide using portable gamma spectroscopy without dismantling reactor head, and the result of direct measurement was supplemented by performing indirect measurement. Radiochemical analysis were performed on surface contamination samples as well. During the study, radiological inventory of reactor vessel calculated expanding the result. Based on the result and the radioactivity variation of each radionuclides time frame for decommissioning can be decided. Thus, it is expected that during the decommissioning of plants, the result of this study will contribute to the reduction of radiation exposure to workers.

A Study on the Types of Work Values of Radiologic Technology Students (방사선과 학생의 직업가치관 유형에 관한 연구)

  • Kim, Hark-Sung
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.271-280
    • /
    • 2007
  • The objectives of this study were to identify the types of work values of radiological technology students and to verify the characteristics of them. The population of this study was the radiological technology students from 7 colleges randomly chosen in the whole country. data collected from 791 subjects were used. Types of work values were identified through the factor analysis and t-test between variables was used to determine the characteristics of the students. The research instrument used in this study was the Maryland Work Value Inventory(MWVI) designed by Meitus, R. The findings of this study were as follows ; 1. The types of work values of radiological technology students can be classified into 6 categories ; social contribution, achievement, capability, work interest, social status, economic reward. 2. Social contribution, achievement, capablity and work interest were classified as 'internal work values', while social status and economic reward as 'external work values'. 3. Work values of the radiological technology students were economic reward, social status, achievement, capablity, work interest, social contribution in order. 4. External work values of the radiological technology students got higher grade than internal work values.

  • PDF

Evaluating Activation for 50 MeV Cyclotron Irradiation Service using Monte Carlo Method and Inventory Code (50 MeV 사이클로트론 조사 서비스로 인한 방사화 평가)

  • Kim, Sangrok;Kim, Gi-sub;Heo, Jaeseung;Ahn, Yunjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.415-427
    • /
    • 2021
  • Korea Institute of Radiological and Medical Sciences has provided various beam irradiation services to researchers using a 50 MeV cyclotron beam line. In particular, since the neutron beam service uses the nuclear reaction between protons and beryllium, the possibility of activation of the irradiated sample increases by using a high current. In this study, MCNP 6.2 and FISPACT-II 4.0 were used to evaluate the possible activation during the 35 MeV 20 ㎂ neutron beam service, which is preferred by the researchers. As a result of the calculation, if the iron, copper, and tungsten samples were irradiated for more than 1 hour, long-lived radioisotopes were produced and their radioactivity exceeded the standard level for self-disposal. Under the conditions of 2 hours of daily irradiation, no activation occurred in the building materials, and the internal exposure of workers due to air activation inside the irradiation room was very insignificant. And when this air was discharged to environment, the radioactivity including this air was also satisfied the emission standard.

Assessment of Neutron Skyshine Dose in a Cargo Inspection Facility Using High Energy X-ray (고에너지 X-ray를 이용한 화물검색시설에서의 중성자 Skyshine 방사선량률 평가)

  • Cho, Young-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.3
    • /
    • pp.27-31
    • /
    • 2008
  • The radiation protection measures for the photoneutrons are one of the most important issue of radiation safety in high energy X-ray facilities. When the photoneutrons are released from the facility, the general public as well as occupational workers are exposed to unexpected radiations by neutron skyshine effect. In this study, the photoneutron inventory are calculated using monte carlo mothed, and the neutron skyshine dose rate is assessed using the inventory. A 9MeV X-ray cargo inspection facility is considered as a reference facility.

  • PDF

On using computational versus data-driven methods for uncertainty propagation of isotopic uncertainties

  • Radaideh, Majdi I.;Price, Dean;Kozlowski, Tomasz
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1148-1155
    • /
    • 2020
  • This work presents two different methods for quantifying and propagating the uncertainty associated with fuel composition at end of life for cask criticality calculations. The first approach, the computational approach uses parametric uncertainty including those associated with nuclear data, fuel geometry, material composition, and plant operation to perform forward depletion on Monte-Carlo sampled inputs. These uncertainties are based on experimental and prior experience in criticality safety. The second approach, the data-driven approach relies on using radiochemcial assay data to derive code bias information. The code bias data is used to perturb the isotopic inventory in the data-driven approach. For both approaches, the uncertainty in keff for the cask is propagated by performing forward criticality calculations on sampled inputs using the distributions obtained from each approach. It is found that the data driven approach yielded a higher uncertainty than the computational approach by about 500 pcm. An exploration is also done to see if considering correlation between isotopes at end of life affects keff uncertainty, and the results demonstrate an effect of about 100 pcm.

원전 humidifier 제어용 감압 밸브 제염 및 방사능 inventory 평가

  • 김진태;지준화;김진길;강덕원
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.233-234
    • /
    • 2004
  • 최근 들어 국제 방사선 방호위원회(ICRP: International Commission on Radiological Protection)의 ICRP-60에서는 원전 작업종사자의 연간 허용 피폭량을 현행값인 5 rem보다 연 평가 2 rem으로 제한 운영토록 권고하고 있다. 이렇게 엄격해지는 방사선 관리규정에 능동적으로 대처할 수 있도록 새로운 방호차원에서 관련 계통 및 기기들의 방사선량을 낮출 수 있는 기술 개발이 절실한 실정이다. 각국의 원전에서는 방사능을 강구하고 있는 실정이다.(중략)

  • PDF

Suggestion on Screening Concept of Radionuclides to be Considered for the Radiological Safety Assessment of the Domestic KBS-3 Type Geological Disposal Facility of High-level Radioactive Waste(HLW) (국내 KBS-3 방식 고준위방사성폐기물 심층처분시설 방사선학적 안전성 평가 대상 방사성핵종 목록 선정개념(안) 제언)

  • Sukhoon Kim;Donghyun Lee;Dong-Keuk Park
    • Journal of Radiation Industry
    • /
    • v.17 no.1
    • /
    • pp.45-59
    • /
    • 2023
  • The transport calculation for a wide variety of radionuclides contained in high-level radioactive waste, especially spent nuclear fuel, is computationally difficult, and input data collection for this also take a considerable amount of time. Accordingly, considering limited resources, it is possible to reduce the calculation time while minimizing impact on accuracy by including only radionuclides important to calculation result through applying some criteria among potential radiation source terms that may release into environment. In this paper, therefore, we reviewed and analyzed the screening process performed to select radionuclides to be considered in the safety assessment for the KBS-3 type repository in Sweden and Finland. In both countries, it was confirmed that a list of radionuclides was selected by comprehensively considering screening criteria such as radioactivity inventory, half-life, radiotoxicity, risk quotient, and transport properties, and etc. A comparison of radionuclides included in the radiological safety assessment in both countries suggests that most of nuclides are considered in common, and a few nuclides considered only in one country are due to differences in decay chain treatment or spent fuel types. As of now, since most of information on the disposal facility in Korea has not been determined, it is necessary to comprehensively model release and transport of all radionuclides considered in Sweden and Finland when performing the radiological safety assessment. Based on these results, we derived the screening concept of selecting a list of radionuclides to be considered in the radiological safety assessment for the domestic KBS-3 type geological disposal facility, and this result is expected to be used as technical basis for confirming conformity with the safety objective. In a more detailed evaluation reflecting domestic characteristics in the future, it would be desirable to consider only radionuclides selected in accordance with the screening procedure. However, further research should be conducted to determine the quantitative limit for each criteria.

A Study About Radionuclides Migration Behavior in Terms of Solubility at Gyeongju Low- and Intermediate-Level Radioactive Waste (LILW) Repository

  • Park, Sang June;Byon, Jihyang;Lee, Jun-Yeop;Ahn, Seokyoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.19 no.1
    • /
    • pp.113-121
    • /
    • 2021
  • A safety assessment of radioactive waste repositories is a mandatory requirement process because there are possible radiological hazards owing to radionuclide migration from radioactive waste to the biosphere. For a reliable safety assessment, it is important to establish a parameter database that reflects the site-specific characteristics of the disposal facility and repository site. From this perspective, solubility, a major geochemical parameter, has been chosen as an important parameter for modeling the migration behavior of radionuclides. The solubilities were derived for Am, Ni, Tc, and U, which were major radionuclides in this study, and on-site groundwater data reflecting the operational conditions of the Gyeongju low and intermediate level radioactive waste (LILW) repository were applied to reflect the site-specific characteristics. The radiation dose was derived by applying the solubility and radionuclide inventory data to the RESRAD-OFFSITE code, and sensitivity analysis of the dose according to the solubility variation was performed. As a result, owing to the low amount of radionuclide inventory, the dose variation was insignificant. The derived solubility can be used as the main input data for the safety assessment of the Gyeongju LILW repository in the future.

Survey of the Musculoskeletal Disorders of Riot Police and Conscripted Policeman in Radiologic Examination (전.의경의 방사선 검사를 통한 근골격계 질환 현황 조사)

  • Cho, Jae-Hwan;Kang, Maeng-Jin;Seok, Jong-Min;Jeun, Sung-Joon;Lim, Youn-Shik;Jeong, Jae-Kyo;Kim, Hyeon-Ju;Ju, Myeong-Shik;Dong, Kyung-Rae;Park, Cheol-Soo;Lee, Jin;Lee, Hae-Kag
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.315-324
    • /
    • 2011
  • The purpose of this study was to use as basic data for the is systematic and efficient facility inventory of policeman and the riot police, conscripted policeman. First, the analysis was performed for the patient implementing the simple x-ray, CT, and MRI examination to the policeman and the riot police, conscripted policeman within the radiologic examination. As to the classification by disease, it classified into the partial body as the common disease and musculoskeletal system disease. As to the fixed quantity comparison of the policeman and the riot police, conscripted policeman the basic X-ray, CT, MRI examination by part average personnel was compared. As to the research result the riot police, conscripted policeman, the Lower extremity examination occupies the simple X-ray, CT, and MRI examination in comparison with the other part altogether much and particularly, the Knee examination ratio occupies much among the Lower extremity examination.