• Title/Summary/Keyword: Radiological Education

Search Result 266, Processing Time 0.028 seconds

Development of Standard Process for Private Information Protection of Medical Imaging Issuance (개인정보 보호를 위한 의료영상 발급 표준 업무절차 개발연구)

  • Park, Bum-Jin;Yoo, Beong-Gyu;Lee, Jong-Seok;Jeong, Jae-Ho;Son, Gi-Gyeong;Kang, Hee-Doo
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.335-341
    • /
    • 2009
  • Purpose : The medical imaging issuance is changed from conventional film method to Digital Compact Disk solution because of development on IT technology. However other medical record department's are undergoing identification check through and through whereas medical imaging department cannot afford to do that. So, we examine present applicant's recognition of private intelligence safeguard, and medical imaging issuance condition by CD & DVD medium toward various medical facility and then perform comparative analysis associated with domestic and foreign law & recommendation, lastly suggest standard for medical imaging issuance and process relate with internal environment. Materials and methods : First, we surveyed issuance process & required documents when situation of medical image issuance in the metropolitan medical facility by wire telephone between 2008.6.1$\sim$2008.7.1. in accordance with the medical law Article 21$\sim$clause 2, suggested standard through applicant's required documents occasionally - (1) in the event of oneself $\rightarrow$ verifying identification, (2) in the event of family $\rightarrow$ verifying applicant identification & family relations document (health insurance card, attested copy, and so on), (3) third person or representative $\rightarrow$ verifying applicant identification & letter of attorney & certificate of one's seal impression. Second, also checked required documents of applicant in accordance with upper standard when situation of medical image issuance in Kyung-hee university medical center during 3 month 2008.5.1$\sim$2008.7.31. Third, developed a work process by triangular position of issuance procedure for situation when verifying required documents & management of unpreparedness. Result : Look all over the our manufactured output in the hospital - satisfy the all conditions $\rightarrow$ 4 place(12%), possibly request everyone $\rightarrow$ 4 place(12%), and apply in the clinic section $\rightarrow$ 9 place(27%) that does not medical imaging issuance office, so we don't know about required documents condition. and look into whether meet or not the applicant's required documents on upper 3month survey - satisfy the all conditions $\rightarrow$ 629 case(49%), prepare a one part $\rightarrow$ 416 case(33%), insufficiency of all document $\rightarrow$ 226case(18%). On the authority of upper research result, we are establishing the service model mapping for objective reception when image export situation through triangular position of issuance procedure and reduce of friction with patient and promote the patient convenience. Conclusion : The PACS is classified under medical machinery that mean indicates about higher importance of medical information therefore medical information administrator's who already received professional education & mind, are performer about issuance process only and also have to provide under ID checking process exhaustively.

  • PDF

Extra Dose Measurement of Differential Slice Thickness of MVCT Image with Helical Tomotherapy (토모테라피 치료 시 MVCT Image의 Slice Thickness 차이에 따른 선량 비교)

  • Lee, Byungkoo;Kang, Suman
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.145-149
    • /
    • 2013
  • Helical Tomotherapy is an innovative means of delivering intensity modulated radiation therapy (IMRT) using a device that merges features of a linear accelerator and helical computed tomography (CT) scanner. Hereat, during helical tomotherapy process, megavoltage computed tomography (MVCT) image are usually used for guiding the precise set-up of patient before/after treatment delivery. But which would certainly increase the total dose for patients, this study was to investigate the imaging dose of MVCT using the cylindrical "Cheese" phantom on a tomotherapy machine. A set of cylindrical "Cheese" phantom was adopted for scanning with respectively pitch value (1, 2, 3 mm) with same number slice (10 slice), same length (approximately 9 cm) and phantom set-ups on the couch of tomotherapy system. The average MVCT imaging dose were measured using A1SL ion chamber inserted in the phantom with preset geometry. The MVCT scanning average dose for the cylindrical "Cheese" phantom was 2.24 cGy, 1.02 cGy, 0.81 cGy during respectively pitch value (pitch 1, 2, 3 mm) with same number slice (10 slice), and same length's average dose was 2.47 cGy, 1.28 cGy, 0.88 cGy respectively (pitch 1, 2, 3 mm). Two major parameters, the assigned pitch numbers and scanning length, where the most important impacts to the dose variation. The MVCT dose was inversely proportional to the CT pitch value. The results may provide a reliable guidance for proper planning design of the scanning region, which is valuable to help minimize the extra dose to patient. Questionnaires were distributed to Radiology departments at hospitals with 300 sickbeds throughout the Pohang region of North Gyeongsang Province concerning awareness and performance levels of infection control. The investigation included measurements of the pollution levels of imaging equipment and assistive apparatuses in order to prepare a plan for the activation of prevention and management of hospital infections. The survey was designed to question respondents in regards to personal data, infection management prevention education, and infection management guidelines.

Combined Exercise in Premenopausal Women Effects on Body Composition and Bone Mineral Density (복합운동이 폐경 전 성인여성의 신체조성 및 골밀도에 미치는 영향)

  • Kim, Kyung-Hee;Lee, Jung-Hee;Yeo, Jin-Dong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.145-155
    • /
    • 2017
  • The purpose of this study was to compare and analyze changes in body composition and bone mineral density (BMD) during combined exercise in premenopausal women who did not take regular diet or regular physical activity within 6 months, In addition to being able to recognize the importance of pre-menopausal women's health and exercise, it also provides basic data for the development of educational programs for early prevention of osteoporosis prevention education I want to. The average age of the subjects in their 30s was 35.44 years and their height was 158.89 cm in their 30s. The average age of the subjects in their 40s was 41.89 and their average height was 160.78 cm in their 40s. Body composition, BMI, and body fat percentage were higher in the 30s, and bone mineral content, lean body mass, skeletal muscle mass, body weight, body fat mass and waist circumference were higher in their forties. Lumbar spine BMD and femur density were higher in their 30s than their 40s. Body composition, skeletal muscle mass, and fat mass increased in the 30s body composition by age - related complex exercise in premenopausal women, body fat mass, body fat percentage, waist circumference decreased. Body mass, body fat, body fat percentage, and BMI decreased in the 40s. The lumbar spine, the lumbar spine, the lumbar spine, and the femur were increased in the lumbar spine, the lumbar spine, the femur, and the femur. In the post-analysis results, changes in body composition were statistically significant due to decrease in muscle mass, body weight, body fat mass and BMI after combined exercise. In the change of bone density, lumbar spine BMD was measured as lumbar spine 1, lumbar spine 2, lumbar spine 3, And the femur density was increase.

Analysis of Urine Iodine Excretion Decrease by Two-Week Stringent Low Iodine Diet for Remnant Thyroid Ablation with Radioactive Iodine in Korean Patients with Thyroid Cancer; Prospective Study (한국 갑상선암 환자들에서 잔여갑상선 제거를 위한 방사성요오드 치료 전 2주간의 엄격한 저요오드식이에 의한 소변 내 요오드량 감소 분석; 전향적 연구)

  • Choi, Joon-Hyuk;Kim, Hoon-Il;Park, Jang-Won;Song, Eun-Hoon;Ko, Bong-Jin;Cheon, Gi-Jeong;Kim, Byung-Il
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.5
    • /
    • pp.375-382
    • /
    • 2008
  • A low iodine diet (LID) is the recommended preparation for radioactive iodine treatment. However, the recommended duration and stringency of LID are different among each recommendation. More stringent LID is expected in Korea because Korea is a iodine-rich region. We investigated the decrement of urine iodine excretion by two-week stringent LID for remnant thyroid ablation with radioactive iodine in Korean patients with thyroid cancer, prospectively. Material and Method: From November 2006, patients who referred to our hospital for remnant ablation after total thyroidectomy were included in this study. To decrease total body iodine, our protocol included three strategies. First, we checked medication which could inhibit the radioactive iodine uptake. Second, the date of 1-131 treatment was scheduled at least 3 months later if contrast agent had been used. The last strategy was two-week stringent LID education by specialized nutritionist. Before and after two-week stringent LID, 24hr-urine iodine was analyzed respectively. 24hr-urine creatinine was also analyzed for determining more valid 24hr urine sampling subgroup. Results: Total 51 patients were finally enrolled. Average of 24hr-urine iodine excretion was significantly lowered ($787{\pm}2242\;{\rightarrow}\;85{\pm}85\;{\mu}g/d$, p=0.03) after LID and 74.4% of patients reached below the recommended urine iodine excretion level ($<100\;{\mu}g/d$). In subgroup (n=14), similar results was showed ($505{\pm}666\;{\rightarrow}\;99{\pm}116\;{\mu}g/d$, p=0.05) and 78.6% of patients met the criteria. Conclusion: Most patients could reach below the recommended urine iodine level after two-week stringent LID. Therefore, in our opinion, at least two-week stringent LID should be recommended in Korea.

Factors associated with Electronic Cigarettes Use in Korean Adults (한국 성인의 전자담배 사용 관련요인)

  • Park, Eui-Cheol;Bae, Seok-Hwan;Lee, Moo-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.47-55
    • /
    • 2019
  • This study was conducted to investigate the factors associated with electronic cigarette use by Korean adults. To accomplish this, data collected from 228,477 individuals during a community health survey conducted by the Korean Centers for Disease Control and Prevention in 2015 were analyzed by descriptive analysis, the Chi-squared test, and logistic regression analysis. The lifetime prevalence of electronic cigarette smoking was 11.1% for men and 0.8% for women. The current prevalence for electronic cigarettes smoking was 24.2% for men and 26.1% for women among lifetime users of electronic cigarettes. The lifetime experience rate of electronic cigarette smoking was significantly associated with age, educational attainment, occupation, income status and current smoking status, respectively. The current universal smoking e-cigarette is significantly related to the current smoking status, which shows a significantly higher number of current smokers than groups that have smoked in the past. The preference for electronic cigarette smoking was high. E-cigarettes were perceived by those who aimed to quit smoking as having a smoking cessation effect compared to regular cigarettes while also providing the pleasure of smoking and addressing the addiction. Therefore, e-cigarettes were highly favored because they were reflected as a solution to the dilemma of smoking. In 2014, electronic cigarette imports tripled from the previous year, and interest in electronic cigarettes is increasing worldwide. Accordingly, measures related to the prevention and discontinuation of e-cigarettes should be considered. Strengthening anti-smoking education and active promotion of anti-smoking risks is needed to improve smokers' wrong perception of smoking-related health. The WHO also reports that there is a lack of grounds to ensure or acknowledge that e-cigarettes are effective. Accordingly, it is important to identify environmental factors influencing the use of electronic cigarettes and explore the relationship between electronic cigarette recognition and use.

Analysis of the Perception of Radiological Technology University Students about the Latest Technology in the Era of the 4th Industrial Revolution (4차 산업혁명시대 최신 기술에 대한 방사선과 대학생의 인식도)

  • Jang, Hyon-Chol
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.225-231
    • /
    • 2022
  • Transcendence of space and time, virtual reality, augmented reality, etc. are being realized through the latest technologies in the era of the 4th industrial revolution. In a situation where they are currently experiencing artificial intelligence, augmented reality, big data, etc., the degree of interest in the latest technologies of the 4th industrial revolution for radiology students, the necessary competencies in the 4th industrial revolution era, and the prospect of the radiation field employment environment in the 4th industrial revolution era The purpose of this study was to find out the level of awareness of From February 7th to February 18th, 2022, surveys on awareness were analyzed using questionnaires for 2nd and 3rd year students in the Department of Radiology at S University in Daegu. As a result of the study, the level of interest in 3D modeling was shown to be the highest with an average of 3.34 ± 1.09 points, and interest in big data and artificial intelligence was also shown with an average of 3.27 ± 1.17 and 3.33 ± 1.07 points. In addition, the correlation between the awareness of the necessary competencies in the 4th industrial revolution era and the awareness of the prospects for employment in the radiation field in the 4th industrial revolution era was the highest (r=0.778, p<0.01), and the interest in the latest technologies in the 4th industrial revolution and the 4th industrial revolution It was found that there was also a correlation between the perceptions of the necessary capabilities of the times (r=0.694, p<0.01). In the era of the 4th industrial revolution, it is judged that it is necessary to strengthen professional education that can handle the latest technologies such as 3D printing, artificial intelligence, and big data, and to strengthen employment capabilities related to the latest technologies in the field of radiation medical technology.