• Title/Summary/Keyword: Radiologic Science

Search Result 480, Processing Time 0.022 seconds

The assessment of the automatic exposure control system for mammography x-ray machine

  • Kim, Hak-Sung;Kim, Sung-Chul
    • International Journal of Contents
    • /
    • v.9 no.2
    • /
    • pp.66-69
    • /
    • 2013
  • In the U.S., performance assessment on the Automatic Exposure Control system (AEC) is managed according to the Mammography Quality Standards Act (MQSA). However, The AEC is not available in the performance assessment conducted in Korea. Also, there is no study made on the performance of the automatic exposure control system for mammography in Korea. For this reason, this study examined the performance of the automatic exposure control system for mammography that was clinically used in the Incheon area. Result showed that the difference of the mean optical density was 0.79 ~ 2.81. This implies that some devices caused unnecessary x-ray exposure to patients. Furthermore, only 61.5% of the entire experimental device was shown to be satisfactory in terms of change in mean optical density. Moreover, in terms of the subject's thickness, change in radiographic density was shown to be severe among lower X-ray tube voltage while there was severe density change in X-ray image depending on X-ray tube voltage among the subjects with more thickness. Therefore, it is suggested to provide performance management on the AEC for mammography.

A rare case report of ameloblastic fibrodentinoma with imaging features in a pediatric patient

  • Youjin Jung;Kyu-Young Oh;Sang-Sun Han;Chena Lee
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.207-210
    • /
    • 2024
  • Ameloblastic fibrodentinoma (AFD) is a rare benign odontogenic tumor that resembles an ameloblastic fibroma with dysplastic dentin. This report presents a rare case of mandibular AFD with imaging features in a young patient. Panoramic radiography and computed tomography revealed a well-defined lesion with internal septa and calcified foci, causing inferior displacement of the adjacent molars as well as buccolingual cortical thinning and expansion of the posterior mandible. The lesion was surgically removed via mass excision, and the involved tooth was extracted under general anesthesia. During the 5-year follow-up period, no evidence of recurrence was observed. Radiologic features of AFD typically reveal a moderately to well-defined mixed lesion with varying degrees of radiopacity, reflecting the extent of dentin formation. Radiologists should consider AFD in the differential diagnosis when encountering a multilocular lesion with little dense radiopacity, particularly if it is associated with delayed eruption, impaction, or absence of involved teeth, on radiographic images of young patients.

Multislice computed tomography demonstrating mental nerve paresthesia caused by periapical infection: A case report

  • Yong-Min Kim;Ho-Keun Choi;Jo-Eun Kim;Jeong-Joon Han;Kyung-Hoe Huh
    • Imaging Science in Dentistry
    • /
    • v.54 no.1
    • /
    • pp.115-120
    • /
    • 2024
  • Components derived from an infected lesion within the bone can spread through various passages in the mandible, particularly via the mental foramen. Radiologically, the spread of infection is typically nonspecific and challenging to characterize; however, multislice computed tomography (MSCT) can effectively detect pathological changes in soft tissues and the bone marrow space. This report describes the case of a 55-year-old woman who experienced mental nerve paresthesia due to a periapical infection of the right mandibular second premolar. MSCT imaging revealed increased attenuation around the periapical lesion extending into the mandibular canal and loss of the juxta-mental foraminal fat pad. Following endodontic treatment of the tooth suspected to be the source of the infection, the patient's symptoms resolved, and the previous MSCT imaging findings were no longer present. Increased bone marrow attenuation and obliteration of the fat plane in the buccal aspect of the mental foramen may serve as radiologic indicators of inflammation spreading from the bone marrow space.

Analysis of Reliability by Factors in Developing Tools to Measure Social Support and Stressors in Organizational Culture of Radiological Technologists (방사선사의 사회적 지원과 조직문화의 스트레스 측정도구 개발을 위한 요인별 신뢰도 분석)

  • Lim, Cheong-Hwan;Jung, Hong-Ryang;Lee, Man-Koo
    • Korea Journal of Hospital Management
    • /
    • v.11 no.3
    • /
    • pp.42-55
    • /
    • 2006
  • The present study is designed to develop surveying tools to measure stressors of and social supports for Radiological Technologists which may play a role to alleviate their stresses caused from their job environments. For this purpose, an analysis of reliability by factors of personal stressors was conducted on 890 radiologists who are working at 44 general hospitals in 16 cities and provinces across the country. The results of the analysis may be summed up as follows: Six factors in 2 concerned fields turned out to be major tools for use as items of questionnaires to measure social supports for and organizational culture of Radiological Technologists. The factors determined to be applicable for survey with reliability coefficient of more than 0.7 measured by factors for internal coherence included social supports on the job(0.90), off-the-job social supports(0.81), job satisfaction(0.80), devotion for job by length of service(0.81) and emotional devotion for job(0.80), all deemed to be appropriate as survey items. In the verifying process of the results, it was found that normative devotion for job(0.61) showed lower reliability as its statistical coefficient was analyzed to be less than 0.7. It seemed, therefore, necessary to reconstruct items or re-select such ones only that can maintain internal coherence in order to analyze appropriateness of related measuring tools, or to develop new measuring tools. Although the outcomes of this study can be used to verify reliability and appropriateness of concerned concepts to assess stresses caused during the job performance of Radiological Technologists, it may be improper to adopt them to measure all types of social supports and stresses that occur generally under the job environment. It is desired, however, to compare and analyze the findings of the present study with others and to utilize them as basic data for further development of tools that can maintain internal coherence in terms of reliability and appropriateness in spite of changing social environments.

  • PDF

Positron Emission Computed Tomographs and Image Reconstruction Methods (PET 장치와 화상 재구성법)

  • Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • v.22 no.1
    • /
    • pp.5-11
    • /
    • 1999
  • This paper reviews recent major activities on instrumentation and methodology of PET. The performance of the PET instrumentation can be expressed by four physical characteristics, 1) spatial resolution, 2) coincidence resolving time, 3) energy resolution, and 4) detection efficiency. The physical and technical aspects of PET systems are briefly discussed along with these characteristics. Toward high resolution PET the recent trend has been to design multiple rings of densely packed detector arrays with scintillators. In order to satisfy the sampling requirement in reconstruction, continuous detector units has been developed. Iterative image reconstruction algorithms have received considerable attention for improvement of both the sampling requirement and image quality toward the stationary PET. Better resolving time improves the maximum true coincidence rate, which is also increased with more detectors placed in coincidence with each other. It suggests that volume PET is promising for enhancement of detection efficiency. The scattered coincidence event rate may be reduced by using detectors with better energy resolution. The use of interplane septa, however, takes over improvement of energy resolution in 2D PET. Energy resolution becomes an important factor for image quality under the condition of septa removal such as volume PET. Toward full utilization of emitting photons, 3D reconstruction incorporating oblique rays has been studied, and volume reconstruction algorithms have been developed. Practical volume PET systems impose heavy burden not only to detector sets and coincidence circuits, but also to computers in the memory requirements and the data processing. In conclusion, there have been many ingenious methods in development of PET instrumentation, which are based on unique capability of PET. They will be expected to overcome technical limitations, and to approach the fundamental limits.

  • PDF

Juxtacortical Osteogenic Sarcoma of Chondroblastic Type on the Maxilla (상악골에 발생된 연골형성현 측피질골육종)

  • Choi Sun-Young;Choi Eun-Suk;Koh Kwang-Joon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.539-563
    • /
    • 1998
  • 39-year-old female had been treated for the exophytic mass on buccal aspect of the left, maxillary posterior area 2 years and 8 months ago. Tentative diagnosis was obtained as fibrous dysplasia on clinical and radiographic examinations and histopathologic findings revealed as osteochondroma after bone trimming at that time. She revisited for the treatment of recurred lesions. We reviewed this case with clinical. radiologic and histopathologic standpoints retrospectively, and came to a conclusion that the tumor primarily occurred was juxtacortical osteogenic sarcoma and recurred due to inadequate treatment and then expanded over intramedullary. This case shows that the diagnosis of osteosarcoma should take account of the patient history, clinical. radiographic and histopathologic findings and it requires attentive follow up check. Retrospectively reviewed results were as follows ; At first visit, oral examination revealed a bony hard swelling on the buccal aspect of the left maxillary posterior area. Radiographically, a dense radiopaque mass was noted on the site. The lesion showed hot uptake of /sup 99m/Tc-MDP. Histopathologic diagnosis was done as osteochondroma, but it was considered as osteogenic sarcoma when compared with the recurrent lesion. When she revisited for the treatment of multiple bony swelling on the left maxilla, radiograms showed typical features of malignancy such as widening of periodontal ligament space and sunray appearace, and coincided with benign characters as follows; relatively well circumscribed lesion and expansion and displacement of the adjacent structures. Finally, histopathologic findings of the lesion was well differentiated chondroblastic osteogenic sarcoma.

  • PDF

Radon Blocking Effect of Mask used in Everyday Life (일상생활에서 사용하는 마스크의 라돈 차단 효과)

  • Cheon, Se-Hyeon;Lee, Yong-Ki;Ahn, Sung-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.313-318
    • /
    • 2020
  • Since radon is an inert gas and is a monoatomic molecule, the size of one particle represents the size of an atom, which means that it has a radius of approximately 1 to 100 nm. Therefore, if the mask has a radius smaller than the size of general fine dust and ultra fine dust, but it is possible to block the inhalation of radon more than a certain amount, it is considered that the exposure through the inhalation of radon can be reduced through normal indoor wear. Accordingly, we would like to find out the radon blocking effect of a mask worn in everyday life. Looking at the reduction rate of radon for each mask, cotton masks decreased by 33.45%, medical masks by 33.50%, KF 80 masks by 35.12%, and KF 94 masks by 37.72%. It was found that the radon blocking effect of the cotton and medical masks was somewhat inferior to that of the KF mask, but the difference was not so great that the introduction of radon into the air could be blocked to a certain level by wearing a mask.

Characterization of Li+-ion Exchanged Zeolite Y using Organic Solvents

  • Kim, Hu Sik;Lee, Seok Hee;Park, Kyun Hye;Park, Yong Hyun;Park, Jun Woo;Hwang, Ji Hyun;Park, Jong Sam;Choi, Sik Young;Lim, Woo Taik
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.48 no.3
    • /
    • pp.180-188
    • /
    • 2015
  • To investigate the tendency of $Li^+$ exchange from polar organic solvents, $Li^+$-ion exchange into zeolite Y (Si/Al = 1.56) was attempted by undried methanol (crystal 1) and formamide (crystal 2) solvent. Two single crystals of Na-Y were treated with 0.1 M LiNO3 in each of the two solvents at 323 K, followed by vacuum dehydration at 723 K. Their structures were determined by single-crystal synchrotron X-ray diffraction techniques in the cubic space group $Fd{\bar{3}}m$, at 100(1) K. In both structures, $Li^+$ for $Na^+$ ions filled preferentially sites I' and II. The remaining $Na^+$ ions occupied sites I', II, and III' in both structures, in additional to above sites, and $Na^+$ ions occupied site I in crystal 2. While the 68 % exchange of $Li^+$ for $Na^+$ was achieved from undried methanol, only 40 % exchange was observed from undried formamide, indicating that the undried methanol was more effective than undried formamide as solvent for $Li^+$ exchange under the conditions employed.

Evaluation of Beam-Matching Accuracy for 8 MV Photon Beam between the Same Model Linear Accelerator (동일 기종 선형가속기간 8 MV 광자선에 대한 빔 매칭 정확도 평가)

  • Kim, Yon-Lae;Chung, Jin-Beom;Kang, Seong-Hee
    • Journal of radiological science and technology
    • /
    • v.43 no.2
    • /
    • pp.105-114
    • /
    • 2020
  • This study aimed to assess of beam-matching accuracy for an 8 MV beam between the same model linear accelerators(Linac) commissioned over two years. Two models were got the customer acceptance procedure(CAP) criteria. For commissioning data for beam-matched linacs, the percentage depth doses(PDDs), beam profiles, output factors, multi-leaf collimator(MLC) leaf transmission factors, and the dosimetric leaf gap(DLG) were compared. In addition, the accuracy of beam matching was verified at phantom and patient levels. At phantom level, the point doses specified in TG-53 and TG-119 were compared to evaluate the accuracy of beam modelling. At patient level, the dose volume histogram(DVH) parameters and the delivery accuracy are evaluated on volumetric modulated arc therapy(VMAT) plan for 40 patients that included 20 lung and 20 brain cases. Ionization depth curve and dose profiles obtained in CAP showed a good level for beam matching between both Linacs. The variations in commissioning beam data, such as PDDs, beam profiles, output factors, TF, and DLG were all less than 1%. For the treatment plans of brain tumor and lung cancer, the average and maximum differences in evaluated DVH parameters for the planning target volume(PTV) and the organs at risk(OARs) were within 0.30% and 1.30%. Furthermore, all gamma passing rates for both beam-matched Linacs were higher than 98% for the 2%/2 mm criteria and 99% for the 2%/3 mm criteria. The overall variations in the beam data, as well as tests at phantom and patient levels remains all within the tolerance (1% difference) of clinical acceptability between beam-matched Linacs. Thus, we found an excellent dosimetric agreement to 8 MV beam characteristics for the same model Linacs.

Characterization of the Neutron for Linear Accelerator Shielding Wall using a Monte Carlo Simulation (몬테칼로시뮬레이션을 이용한 선형가속기 차폐벽에 대한 중성자 특성 평가)

  • Lee, Dong Yeon;Park, Eun Tae;Kim, Jung Hoon
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.89-97
    • /
    • 2016
  • As previous studies to proceed with the evaluation of the radioactive at linear accelerator's shielding concrete wall. And the shielding wall was evaluated the characteristics for the incoming neutron. As a result, the shielding wall is the average amount of incoming neutrons 10 MV 4.63E-7%, 15 MV 9.69E-6%, showed the occurrence of 20 MV 2.18E-5%. The proportion of thermal neutrons of which are found to be approximately 18-33%. The neutron generation rate can be seen as a slight numerical order. However, in consideration of the linear accelerator operating time we can not ignore the effects of neutrons. Accordingly radioactive problem of the radiation shield wall of the treatment room will be this should be considered.