Background and Objectives: Iodine is an essential constituent of the thyroid hormones associated with the growth and development of humans and animals as an inorganic nutrition. This element may be accumulated in human blood, tissues and body through the intake of foodstuffs, a beverage, a nutritional supplement and a medicine, among others. The aim of the research is to find out a better medicinal stuff for the thyroid cancer patient who required a low level of iodine diet. Methods: Neutron activation analysis (NAA) used for the iodine analysis is one of nuclear analytical techniques using radiation and radioisotopes and very useful as sensitive analytical technique for performing both qualitative and quantitative multi-elemental non-destructive analysis of major, minor and trace components in variety of environmental and biological materials. In this study, iodine contents in ten kinds of oriental herb medicinal products, which is frequently used to cancer patients are determined by using instrumental neutron activation analysis (INAA) at the HANARO research reactor. The samples prescribed are manufactured as powdered form for taking medicine easily. The analytical quality control is performed to assure an uncertainty of the measurement and to compensate the measured data using a biological certified reference material, NIST SRM 1572, Citrus Leaves. The measured value is $1.89{\pm}0.35mg/kg$, and the relative error is 2.88%, and relative standard deviation is 19 % due to high counting error by small counts of gamma ray spectrum. The standard deviations for other elements such as Cl, K, Mn and Na were in the range of 2 to 8%. Result: The level of iodine contents of Biki-huan, Chungryong-huan and Chungcho-huan, samples detected is less than 6 mg/kg except Hangam Plus sample (more than 210 mg/kg) and six samples were not detected. Iodine in the samples of Shoxiho-tang, Shopunghualhyl-tang, Shocungryong-tang, Banhasaxim-tang, Insampaedox-san and Myunyuk Plus were not measured, but possible level of content can be estimated from the detection limits. In addition, the concentrations of some major elements like Cl, K, Mn, Na, in the samples were determined with the detection limits. Conclusions: Most of samples showed low iodine contents of less than 6 mg/kg but it turned out that most of testing samples can be used to classify the level of iodine diet samples considering the recommended low level of iodine diet 50 ${\mu}g$/day, and a better medicinal stuff for the thyroid cancer patient can be found.
The purpose of this study is to figure out how uptake counts of technetium ($^{99m}Tc$) among radioisotopes in the human body are affected if computed tomography (CT), magnetic resonance imaging (MRI) and isotope examination are performed consecutively. $^{99m}Tc$ isotope material, iodinated contrast media for CT and paramagnetic contrast media for magnetic resonance (MR) were used as experimental materials. First, $^{99m}Tc$ was added to 4 cc normal saline in a test tube. Then, 2 cc of CT contrast media such as $Iopamidol^{(R)}$ and $Dotarem^{(R)}$ were diluted with 2 cc normal saline, and 2cc of MRI contrast media such as $Primovist^{(R)}$ and $Gadovist^{(R)}$ were diluted with 2 cc normal saline. Each distributed contrast media was a total of 4 cc and included 10m Ci of $^{99m}Tc$. A gamma camera, a LEHR (Low energy high resolution) collimator and a pin-hole collimator were used for image acquisition. Image acquisition was repeated a total of 6 times and 120 frames were obtained and uptake counts of $^{99m}Tc$ were measured (from this procedure). In this study, as a result of measuring the uptake counts of $^{99m}Tc$ using the LEHR collimator, the uptake counts were less measured in all contrast media than normal saline as a reference. In particular, the lowest uptake counts were measured when $Gadovist^{(R)}$, contrast media for MRI, was used. However, the result of measuring the uptake counts of $^{99m}Tc$ using the pin-hole collimator showed higher uptake counts in all contrast media, except for $Iopamidol^{(R)}$, than normal saline as a reference. The highest uptake counts were measured particularly when $Primovist^{(R)}$, contrast media for MRI, was used. In performing the gamma camera examination using contrast media and $^{99m}Tc$, it is considered significant to check the changes in the uptake counts to improve various diagnosis values.
To investigate the radiation effect of P-32 on the soybean plants, the seeds treated with various levels of P-32 solution were sown and cultured in the pots. The growth of the plants and the contents of the macroelements were observed and the following results were obtained. 1) The linear growth of the plants at the early stage seemed to have been promoted by the low-level P-32 treatemnt. At the later growing stage, however, this difference among treatments were less conspicuous. 2) The plants of high level P-32 application showed some growth damaging symptom at the early growing stage. Later this damage was recorded as the time went on and these plants showed even better growth than the control. As a result at the late growing stage, they ensued highest growth. 3) The plants showed in general more growth at the low activity level than at the high-level at the early growing stage. At the late stage, however, the high-level activity promoted more growth than the low-level. 4) At the early growing stage P-32 treatment produced in general significantly more lower than control. At the later stage, however, this difference was not clearly seen. 5) The P-32 treatment seemed to have stimulated earlier florescence and this tendency was more clearly observable eapecially at the high activity level. 6) The weight of the air-dried seeds tended to be increased through P-32 treatment by 10-45%. This tendency was clearly observed especially at the low-level activity. 7) As for the contents of the various macroelements in the leaves, the nitrogen showed significantly larger contents at the middle level(S1) P-32 treatments. The phosphorous contents showed also highest at the middle levels activity and lower both at the high and low-activity levels. The potassium contents was proved, on the contrary, higher at the low-level activity and lower at the high-level. 8) The nitrogen contents in the stems was found significantly higher than control, except at the low-activity level. The phosphorous showed higher contents at the low-activity level and no significant difference at the high-activity level. As for the contents of potassium, calcium and magnesium, three seemed no significant difference among treatments. However, the magnesium showed somewhat higher content at the low-activity level, whereas the calcium was proved high than control. 9) The inorganic contents in the root showed that N and P in the P-32 treated plant were significantly higher than the control and the K-contents was, on the contrary, significantly higher at the control than the rest of the treatments. As for the calcium and magnesium there showed no difference among all treatments.
Lee, Hong Jin;Park, Jun Hyung;Moon, Byung Seok;Lee, In Won;Lee, Byung Chul;Kim, Sang Eun
The Korean Journal of Nuclear Medicine Technology
/
v.16
no.2
/
pp.106-109
/
2012
Purpose : The KOTRON-13 cyclotron was developed and installed in regional cyclotron centers to produce short-lifetime medical radioisotopes. However, this cyclotron has limited capacity to produce $^{11}C$ so far. In present study, we developed an effective $^{11}C$ target system combining with fluorine-18 target and applied to the production of various $^{11}C$ radiopharmaceuticals. Materials and Methods : To develop the optimal $^{11}C$ target system and effective its cooling system, we designed the $^{11}C$ target system by Stopping and Range of Ions in Matter (SRIM) simulation program and considered the cavity pressure during irradiation at target grid. In this investigation, we modified target materials, cavity shapes and the position of cooling system in $^{11}C$ target and then evaluated $[^{11}C]CO_2$ production at different beam currents, thickness of the target foil, oxygen content of nitrogen gas and target gas loading pressure. Also, we evaluate the production of several $^{11}C$ radiopharmaceuticals such as [$^{11}C$]PIB, [$^{11}C$]DASB, and [$^{11}C$]Clozapine. Results : $[^{11}C]CO_2$ was produced about 74 GBq for 30min irradiation at 60 ${\mu}A$ of beam current as following conditions: thickness of the target foil: 19 nm HAVAR, oxygen content of nitrogen: under 50 ppb, target gas loading pressure: 24 bar. Additionally, the cooling system was stable to produce $[^{11}C]CO_2$ at high beam current. The radiochemical yields of [$^{11}C$]PIB, [$^{11}C$]DASB, and [$^{11}C$]Clozapine showed about 26-38% with over 127 GBq/umol of specific activity. Conclusion : The carbon-11 target system in the KOTRON-13 cyclotron was successfully developed and showed stable production of $[^{11}C]CO_2$. These results showed that our $^{11}C$ target system will be compatible with other commercial system for the routine $^{11}C$ radiopharmaceuticals production in the KOTRON-13 cyclotron.
Lee, Bu Hyung;Kim, Sung Ho;Kwon, Soo Il;Kim, Jae Seok;Kim, Gi-sub;Park, Min Seok;Park, Seungwoo;Jung, Haijo
Progress in Medical Physics
/
v.27
no.3
/
pp.146-155
/
2016
As the probability of exposure to radiation increases due to an increase in the use of radioisotopes and radiation generators, the importance of a radiation safety management field is being highlighted. We intend to help radiation workers with exposure management by identifying the degree of radiation exposure and contamination to determine an efficient method of radiation safety management. The personal exposure doses of the radiation workers at the Korea Institute of Radiological & Medical Sciences measured every quarter during a five-year period from Jan. 1, 2011 till Dec. 31, 2015 were analyzed using a TLD (thermoluminescence dosimeter). The spatial dose rates of radiation-controlled areas were measured using a portable radioscope, and the level of surface contamination was measured at weekly intervals using a piece of smear paper and a low background alpha/beta counter. Though the averages of the depth doses and the surface doses in 2012 increased from those in 2011 by about 14%, the averages were shown to have decreased every year after that. The exposure dose of 27 mSv in 2012 increased from that in 2011 in radiopharmaceutical laboratories and, in the case of the spatial dose rate, the rate of decrease in 2012 was shown to be similar to the annual trend of the whole institute. In the case of the surface contamination level, as the remaining radiation-controlled area with the exception of the I-131 treatment ward showed a low value less than $1.0kBq/m^2$, the annual trend of the I-131 treatment ward was shown to be similar to that of the entire institute. In conclusion, continuous attention should be paid to dose monitoring of the radiation-controlled areas where unsealed sources are handled and the workers therein.
Kim, Chung-Suk;Lee, Suk-Koo;Ahn, Hak-Soo;Sun, Soon-Wha
Journal of Korean Society of Forest Science
/
v.37
no.1
/
pp.35-40
/
1978
The uptake ratio of supplying $P^{32}$ labelled double superphosphate and the hastening efficiency of the uptake by addition of magnesium sulfate to the fertilizer were studied on the ${\times}Populus $ albaglandulosa planted with 0/1 cutting in 1975. The results are summerized as follows. 1. Average 13% of supplying double superphosphate was absorbed into ${\times}Populus$ albaglandulosa planted on the reddish heavy clay soil in Institute of Forest Genetics. 2. The accumulation of absorbed magnesium was more amount in leaf than in stem. 3. The uptake ratio of supplying double superphosphate was able to increase up to 16%~33% by the addition of magnesium sulfate to the fertilizer. 4. It might be possible to increase the tree growth following the acceleration of photosynthesis due to the increasing amount of magnesium known to be a component of chlorophyll in leaf as well as to hasten the efficiency of uptake of phosphorus by the addition of magnesium to double superphosphate.
Purpose: The KOTRON-13 cyclotron was developed in South Korea and was introduced to regional cyclotron centers to produce short-lifetime medical radioisotopes. However, this cyclotron has limited capacity to produce carbon-11 isotope so far. We herein study how to develop and optimize an effective carbon-11 target system in the KOTRON-13 cyclotron by changing cooling system, combing with fluorine-18 target and evaluating beam currents. Materials and Method: To develop the optimal carbon-11 target and an effective cooling system, we designed the carbon-11 target system by Stopping and Range of Ions in Matter (SRIM) simulation program and considered the cavity pressure during irradiation at target grid. In this investigation, we evaluated the yield of carbon-11 production at different beam currents and the stability of the operation of the KOTRON-13 cyclotron. Results: The production of carbon-11 was enhanced from about 1.700 mCi ($50{\mu}A$) to 2,000 mCi ($60{\mu}A$) on the carbon-11 target which developed by seoul national university bundang hospital (SNUBH) and Samyoung Unitech. Additionally, the cooling condition was showed stable to produce carbon-11 under high beam current. Conclude: The carbon-11 target system of the KOTRON-13 cyclotron was successfully developed and improved carbon-11 production. Consequently, the operation of carbon-11 target system was highly effective and stable compare with other commercial cyclotrons. Our results are believed that this optimal carbon-11 target system will be helpful for the routine carbon-11 production in the KOTRON-13 cyclotron.
Ji, Young-Yong;Kwak, Kyung-Kil;Hong, Dae-Seok;Shon, Jong-Sik
Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
/
v.10
no.2
/
pp.117-123
/
2012
In order to dispose of the LILW(low and intermediate level radioactive waste) stored at KAERI, the radwaste drum assay system will be introduced to evaluate the radioisotopes inventory of stored drums. At present, the construction project of the dedicated assay facility to operate it and carry out routine maintenance of that equipment has been conducting at the radwaste treatment facility. Since that facility will be constructed in front of a 1st radwaste storage facility as well as the radwaste drums to be assayed and the transmission source in the radwaste drum assay system are in that facility, they could act as the radioactive sources and then, would affect the dose rate at the inside and the outside of the facility. Therefore, the radiation shielding should be evaluated through the concrete wall near to the radioactive sources whether the wall thickness is sufficient against the regulations. In this study, the radiation safety for the concrete wall around the radiation controlled area in the radwaste drum assay facility was evaluated by the MCNP code. From the evaluation results, the thickness of those concrete walls which are under consideration of about 30 cm was enough to shield the radiation from the radioactive sources.
In this study, Sulfonated PONF-g-styrene ion exchange fibers were synthesized by radiation induced graft copolymerization. And also, hybride ion exchange fibers, which was combined sulfonated PONF-g-styrene fibers and cationic ion exchange resin, were fabricated by hot melt adhesion method and then their adsorption properties were investigated. ion exchange capacity and water content of hybrid ion exchange fibers increased as compared with those of bead and ion exchange fiber. Their maximum values were 4.76 meq/g and 23.5%, respectively. Adsorption breakthrough time for mercury of hybrid ion exchange fiber was slower than those of bead resin and fibrous ion exchanger. It's value was 130 minutes. Their breakthrough time become short as increasing of pH, and concentration. The initial breakthrough time was observed before and after 10 minutes as increasing of concentration. The adsorption of hybrid ion exchange fibers for $Hg^{2+}\;Pb^{2+},\;Cd^{2+}$ among heavy metals in the mixed solution was observed before 20 min. And also, The adsorption for $Hg^{2+}$ among the heavy metals by hybride ion exchange fibers was observed.
Buckwheat seeds produced in previous year (1965) in an experimental pot culture in which nine levels of P-32 ranging from $1.4{\times}10-4 to 3.3{\times}104$\mu$c/pot(as of 27 July 1965)$, with the same specific activity, had been applied to the corresponding pots respectively, were used this year(1996) in water and soil culture as well as in germination test to investigate the feature and extent of possible residual effects of P-32 incorporated upon germination and plant growth, and the following results were obtained: 1. Under the given experimental conditions both stimulative and inhibitory effects of radiation were observed. 2. The germination rate of the seeds was lower at the higher level of P-32 aplication ranging from $3.0{\times}103 to 3.3{\times}104$\mu$c/pot$ and higher at 0.2 $\mu$c P/pot than the control. 3. Among the seeds produced at the higher level of application about 80% was failed to germinate, owing to the radiation injury. The remaining 80% was failed to germinate, owing to the radiation injury. The remaining 80% survived the damaging effect and showed vigorous growth and increased yield. The latter group of seeds thus proved themselves to be more radioresistant than the former. 4. The survived seeds produced later more straw and root on dry weight basis. The higher the level of P-32 applied, the stronger the stimulative effect showed in vegetative growth. 5. No radiation effect on linear growth of the plants was observed in the soil culture. 6. The dry weight of straw produced showed little difference at the moderate range compared with that of control in the soil culture. At high level of application, i.e. over $\mu$c P32/pot, however, the production was increased by 12-37% of control. 7. As for the dry weight of root harvested, the P-32 treatment over 24$\mu$c P32/pot produced 82-155% more than the control, whereas little difference was observed under 2.2$\mu$c P32/pot. 8. The seed production increased in general by the P-32 treatments. Particularly at the moderate level of application the rate of increase amounted to 70% of the control. 9. Those individual plants which survived damaging effects of radiation at the germinating stage shwoed remarkable stimulative effects both in vegetative and in reproductive stage of growth.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.