• Title/Summary/Keyword: Radioisotopes

Search Result 193, Processing Time 0.03 seconds

Determination of Iodine Contents in Ten kinds of Frequently used Oriental Herb Medicinal Products for Cancer Patient (암환자에게 다빈도로 활용되는 한약제제 10종에 대한 요오드의 함량 분석)

  • Lee, Chang-Hee;Choi, Jung-Eun;Kim, Sun-Ha;Chung, Yong-Sam;Moon, Jong-Hwa;Yoo, Hwa-Seung
    • Journal of Korean Traditional Oncology
    • /
    • v.16 no.1
    • /
    • pp.41-53
    • /
    • 2011
  • Background and Objectives: Iodine is an essential constituent of the thyroid hormones associated with the growth and development of humans and animals as an inorganic nutrition. This element may be accumulated in human blood, tissues and body through the intake of foodstuffs, a beverage, a nutritional supplement and a medicine, among others. The aim of the research is to find out a better medicinal stuff for the thyroid cancer patient who required a low level of iodine diet. Methods: Neutron activation analysis (NAA) used for the iodine analysis is one of nuclear analytical techniques using radiation and radioisotopes and very useful as sensitive analytical technique for performing both qualitative and quantitative multi-elemental non-destructive analysis of major, minor and trace components in variety of environmental and biological materials. In this study, iodine contents in ten kinds of oriental herb medicinal products, which is frequently used to cancer patients are determined by using instrumental neutron activation analysis (INAA) at the HANARO research reactor. The samples prescribed are manufactured as powdered form for taking medicine easily. The analytical quality control is performed to assure an uncertainty of the measurement and to compensate the measured data using a biological certified reference material, NIST SRM 1572, Citrus Leaves. The measured value is $1.89{\pm}0.35mg/kg$, and the relative error is 2.88%, and relative standard deviation is 19 % due to high counting error by small counts of gamma ray spectrum. The standard deviations for other elements such as Cl, K, Mn and Na were in the range of 2 to 8%. Result: The level of iodine contents of Biki-huan, Chungryong-huan and Chungcho-huan, samples detected is less than 6 mg/kg except Hangam Plus sample (more than 210 mg/kg) and six samples were not detected. Iodine in the samples of Shoxiho-tang, Shopunghualhyl-tang, Shocungryong-tang, Banhasaxim-tang, Insampaedox-san and Myunyuk Plus were not measured, but possible level of content can be estimated from the detection limits. In addition, the concentrations of some major elements like Cl, K, Mn, Na, in the samples were determined with the detection limits. Conclusions: Most of samples showed low iodine contents of less than 6 mg/kg but it turned out that most of testing samples can be used to classify the level of iodine diet samples considering the recommended low level of iodine diet 50 ${\mu}g$/day, and a better medicinal stuff for the thyroid cancer patient can be found.

Influence of Iodinated Contrast Media and Paramagnetic Contrast Media on Changes in Uptake Counts of 99mTc

  • Cho, Jae-Hwan;Lee, Jin-Hyeok;Park, Cheol-Soo;Lee, Sun-Yeob;Lee, Jin;Moon, Deog-Hwan;Lee, Hae-Kag
    • Journal of Magnetics
    • /
    • v.19 no.3
    • /
    • pp.248-254
    • /
    • 2014
  • The purpose of this study is to figure out how uptake counts of technetium ($^{99m}Tc$) among radioisotopes in the human body are affected if computed tomography (CT), magnetic resonance imaging (MRI) and isotope examination are performed consecutively. $^{99m}Tc$ isotope material, iodinated contrast media for CT and paramagnetic contrast media for magnetic resonance (MR) were used as experimental materials. First, $^{99m}Tc$ was added to 4 cc normal saline in a test tube. Then, 2 cc of CT contrast media such as $Iopamidol^{(R)}$ and $Dotarem^{(R)}$ were diluted with 2 cc normal saline, and 2cc of MRI contrast media such as $Primovist^{(R)}$ and $Gadovist^{(R)}$ were diluted with 2 cc normal saline. Each distributed contrast media was a total of 4 cc and included 10m Ci of $^{99m}Tc$. A gamma camera, a LEHR (Low energy high resolution) collimator and a pin-hole collimator were used for image acquisition. Image acquisition was repeated a total of 6 times and 120 frames were obtained and uptake counts of $^{99m}Tc$ were measured (from this procedure). In this study, as a result of measuring the uptake counts of $^{99m}Tc$ using the LEHR collimator, the uptake counts were less measured in all contrast media than normal saline as a reference. In particular, the lowest uptake counts were measured when $Gadovist^{(R)}$, contrast media for MRI, was used. However, the result of measuring the uptake counts of $^{99m}Tc$ using the pin-hole collimator showed higher uptake counts in all contrast media, except for $Iopamidol^{(R)}$, than normal saline as a reference. The highest uptake counts were measured particularly when $Primovist^{(R)}$, contrast media for MRI, was used. In performing the gamma camera examination using contrast media and $^{99m}Tc$, it is considered significant to check the changes in the uptake counts to improve various diagnosis values.

Studies on the effects of radiation from radioisotopes incorporated into plants (Ⅶ) Effects of internally administered P-32 on the growth of soybeans (작물에 흡수된 방사성 동위원소의 내부조사효과에 관한 연구(제7보) 대두의 생장에 미치는 P-32의 영향)

  • 김길환
    • Journal of Plant Biology
    • /
    • v.12 no.3
    • /
    • pp.15-25
    • /
    • 1969
  • To investigate the radiation effect of P-32 on the soybean plants, the seeds treated with various levels of P-32 solution were sown and cultured in the pots. The growth of the plants and the contents of the macroelements were observed and the following results were obtained. 1) The linear growth of the plants at the early stage seemed to have been promoted by the low-level P-32 treatemnt. At the later growing stage, however, this difference among treatments were less conspicuous. 2) The plants of high level P-32 application showed some growth damaging symptom at the early growing stage. Later this damage was recorded as the time went on and these plants showed even better growth than the control. As a result at the late growing stage, they ensued highest growth. 3) The plants showed in general more growth at the low activity level than at the high-level at the early growing stage. At the late stage, however, the high-level activity promoted more growth than the low-level. 4) At the early growing stage P-32 treatment produced in general significantly more lower than control. At the later stage, however, this difference was not clearly seen. 5) The P-32 treatment seemed to have stimulated earlier florescence and this tendency was more clearly observable eapecially at the high activity level. 6) The weight of the air-dried seeds tended to be increased through P-32 treatment by 10-45%. This tendency was clearly observed especially at the low-level activity. 7) As for the contents of the various macroelements in the leaves, the nitrogen showed significantly larger contents at the middle level(S1) P-32 treatments. The phosphorous contents showed also highest at the middle levels activity and lower both at the high and low-activity levels. The potassium contents was proved, on the contrary, higher at the low-level activity and lower at the high-level. 8) The nitrogen contents in the stems was found significantly higher than control, except at the low-activity level. The phosphorous showed higher contents at the low-activity level and no significant difference at the high-activity level. As for the contents of potassium, calcium and magnesium, three seemed no significant difference among treatments. However, the magnesium showed somewhat higher content at the low-activity level, whereas the calcium was proved high than control. 9) The inorganic contents in the root showed that N and P in the P-32 treated plant were significantly higher than the control and the K-contents was, on the contrary, significantly higher at the control than the rest of the treatments. As for the calcium and magnesium there showed no difference among all treatments.

  • PDF

Production of $^{11}C$ labeled Radiopharmaceuticals using $[^{11}C]CO_2$ Produced in the KOTRON-13 (한국형 사이클로트론(KOTRON-13)을 이용한 $[^{11}C]CO_2$ 생산과 다양한 $^{11}C$-표지 방사성의약품 생산 적용)

  • Lee, Hong Jin;Park, Jun Hyung;Moon, Byung Seok;Lee, In Won;Lee, Byung Chul;Kim, Sang Eun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.106-109
    • /
    • 2012
  • Purpose : The KOTRON-13 cyclotron was developed and installed in regional cyclotron centers to produce short-lifetime medical radioisotopes. However, this cyclotron has limited capacity to produce $^{11}C$ so far. In present study, we developed an effective $^{11}C$ target system combining with fluorine-18 target and applied to the production of various $^{11}C$ radiopharmaceuticals. Materials and Methods : To develop the optimal $^{11}C$ target system and effective its cooling system, we designed the $^{11}C$ target system by Stopping and Range of Ions in Matter (SRIM) simulation program and considered the cavity pressure during irradiation at target grid. In this investigation, we modified target materials, cavity shapes and the position of cooling system in $^{11}C$ target and then evaluated $[^{11}C]CO_2$ production at different beam currents, thickness of the target foil, oxygen content of nitrogen gas and target gas loading pressure. Also, we evaluate the production of several $^{11}C$ radiopharmaceuticals such as [$^{11}C$]PIB, [$^{11}C$]DASB, and [$^{11}C$]Clozapine. Results : $[^{11}C]CO_2$ was produced about 74 GBq for 30min irradiation at 60 ${\mu}A$ of beam current as following conditions: thickness of the target foil: 19 nm HAVAR, oxygen content of nitrogen: under 50 ppb, target gas loading pressure: 24 bar. Additionally, the cooling system was stable to produce $[^{11}C]CO_2$ at high beam current. The radiochemical yields of [$^{11}C$]PIB, [$^{11}C$]DASB, and [$^{11}C$]Clozapine showed about 26-38% with over 127 GBq/umol of specific activity. Conclusion : The carbon-11 target system in the KOTRON-13 cyclotron was successfully developed and showed stable production of $[^{11}C]CO_2$. These results showed that our $^{11}C$ target system will be compatible with other commercial system for the routine $^{11}C$ radiopharmaceuticals production in the KOTRON-13 cyclotron.

  • PDF

Analysis of Trends in Dose through Evaluation of Spatial Dose Rate and Surface Contamination in Radiation-Controlled Area and Personal Exposed Dose of Radiation Worker at the Korea Institute of Radiological and Medical Sciences (KIRAMS)

  • Lee, Bu Hyung;Kim, Sung Ho;Kwon, Soo Il;Kim, Jae Seok;Kim, Gi-sub;Park, Min Seok;Park, Seungwoo;Jung, Haijo
    • Progress in Medical Physics
    • /
    • v.27 no.3
    • /
    • pp.146-155
    • /
    • 2016
  • As the probability of exposure to radiation increases due to an increase in the use of radioisotopes and radiation generators, the importance of a radiation safety management field is being highlighted. We intend to help radiation workers with exposure management by identifying the degree of radiation exposure and contamination to determine an efficient method of radiation safety management. The personal exposure doses of the radiation workers at the Korea Institute of Radiological & Medical Sciences measured every quarter during a five-year period from Jan. 1, 2011 till Dec. 31, 2015 were analyzed using a TLD (thermoluminescence dosimeter). The spatial dose rates of radiation-controlled areas were measured using a portable radioscope, and the level of surface contamination was measured at weekly intervals using a piece of smear paper and a low background alpha/beta counter. Though the averages of the depth doses and the surface doses in 2012 increased from those in 2011 by about 14%, the averages were shown to have decreased every year after that. The exposure dose of 27 mSv in 2012 increased from that in 2011 in radiopharmaceutical laboratories and, in the case of the spatial dose rate, the rate of decrease in 2012 was shown to be similar to the annual trend of the whole institute. In the case of the surface contamination level, as the remaining radiation-controlled area with the exception of the I-131 treatment ward showed a low value less than $1.0kBq/m^2$, the annual trend of the I-131 treatment ward was shown to be similar to that of the entire institute. In conclusion, continuous attention should be paid to dose monitoring of the radiation-controlled areas where unsealed sources are handled and the workers therein.

Studies on Uptake Pattern of the Phosphorus Employing Radioisotopes as Tracer on the × Populus albaglandulosa (I) -The correlation between the phosphorus and magnesium contents of the plants, when supplying available magnesium in soil- (방사성동위체(放射性同位體)를 이용(利用)한 × Populus albaglandulosa의 인산흡수상(燐酸吸收相)에 관(關)한 추적연구(追跡硏究) (I) -고토시용(苦土施用)이 식물체내(植物體內)의 인산함유율(燐酸含有率)에 미치는 영향(影響)-)

  • Kim, Chung-Suk;Lee, Suk-Koo;Ahn, Hak-Soo;Sun, Soon-Wha
    • Journal of Korean Society of Forest Science
    • /
    • v.37 no.1
    • /
    • pp.35-40
    • /
    • 1978
  • The uptake ratio of supplying $P^{32}$ labelled double superphosphate and the hastening efficiency of the uptake by addition of magnesium sulfate to the fertilizer were studied on the ${\times}Populus $ albaglandulosa planted with 0/1 cutting in 1975. The results are summerized as follows. 1. Average 13% of supplying double superphosphate was absorbed into ${\times}Populus$ albaglandulosa planted on the reddish heavy clay soil in Institute of Forest Genetics. 2. The accumulation of absorbed magnesium was more amount in leaf than in stem. 3. The uptake ratio of supplying double superphosphate was able to increase up to 16%~33% by the addition of magnesium sulfate to the fertilizer. 4. It might be possible to increase the tree growth following the acceleration of photosynthesis due to the increasing amount of magnesium known to be a component of chlorophyll in leaf as well as to hasten the efficiency of uptake of phosphorus by the addition of magnesium to double superphosphate.

  • PDF

Development and optimization of C-11 gas target system in KOTRON-13 cyclotron (KOTRON-13 사이클로트론의 고효율C-11 가스 표적장치)

  • Lee, Hong-Jin;Lee, Won-Kyeong;Park, Jun-Hyung;Moon, Byung-Seok;Lee, In-Won;Chae, Sung-Ki;Lee, Byung-Chul;Kim, Sang-Eun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.86-89
    • /
    • 2011
  • Purpose: The KOTRON-13 cyclotron was developed in South Korea and was introduced to regional cyclotron centers to produce short-lifetime medical radioisotopes. However, this cyclotron has limited capacity to produce carbon-11 isotope so far. We herein study how to develop and optimize an effective carbon-11 target system in the KOTRON-13 cyclotron by changing cooling system, combing with fluorine-18 target and evaluating beam currents. Materials and Method: To develop the optimal carbon-11 target and an effective cooling system, we designed the carbon-11 target system by Stopping and Range of Ions in Matter (SRIM) simulation program and considered the cavity pressure during irradiation at target grid. In this investigation, we evaluated the yield of carbon-11 production at different beam currents and the stability of the operation of the KOTRON-13 cyclotron. Results: The production of carbon-11 was enhanced from about 1.700 mCi ($50{\mu}A$) to 2,000 mCi ($60{\mu}A$) on the carbon-11 target which developed by seoul national university bundang hospital (SNUBH) and Samyoung Unitech. Additionally, the cooling condition was showed stable to produce carbon-11 under high beam current. Conclude: The carbon-11 target system of the KOTRON-13 cyclotron was successfully developed and improved carbon-11 production. Consequently, the operation of carbon-11 target system was highly effective and stable compare with other commercial cyclotrons. Our results are believed that this optimal carbon-11 target system will be helpful for the routine carbon-11 production in the KOTRON-13 cyclotron.

  • PDF

An Evaluation on the Radiation Shielding of the Radwaste Drum Assay Facility (방사성폐기물드럼 핵종재고량 평가시설 구축에 따른 방사선차폐 영향평가)

  • Ji, Young-Yong;Kwak, Kyung-Kil;Hong, Dae-Seok;Shon, Jong-Sik
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.10 no.2
    • /
    • pp.117-123
    • /
    • 2012
  • In order to dispose of the LILW(low and intermediate level radioactive waste) stored at KAERI, the radwaste drum assay system will be introduced to evaluate the radioisotopes inventory of stored drums. At present, the construction project of the dedicated assay facility to operate it and carry out routine maintenance of that equipment has been conducting at the radwaste treatment facility. Since that facility will be constructed in front of a 1st radwaste storage facility as well as the radwaste drums to be assayed and the transmission source in the radwaste drum assay system are in that facility, they could act as the radioactive sources and then, would affect the dose rate at the inside and the outside of the facility. Therefore, the radiation shielding should be evaluated through the concrete wall near to the radioactive sources whether the wall thickness is sufficient against the regulations. In this study, the radiation safety for the concrete wall around the radiation controlled area in the radwaste drum assay facility was evaluated by the MCNP code. From the evaluation results, the thickness of those concrete walls which are under consideration of about 30 cm was enough to shield the radiation from the radioactive sources.

Adsorption Properties for Heavy Metals Using Hybrid Son Exchange Fibers with Sulfonated PONF-g-Styrene by Radiation Polymerization and Cation Exchange Resin (방사선 중합 설폰화 PONF-g-스티렌과 양이온교환수지 복합 이온교환섬유의 중금속 흡착 특성)

  • Baek, Ki-Wan;Cho, In-Hee;Nho, Young-Chang;Hwang, Taek-Sung
    • Polymer(Korea)
    • /
    • v.30 no.6
    • /
    • pp.525-531
    • /
    • 2006
  • In this study, Sulfonated PONF-g-styrene ion exchange fibers were synthesized by radiation induced graft copolymerization. And also, hybride ion exchange fibers, which was combined sulfonated PONF-g-styrene fibers and cationic ion exchange resin, were fabricated by hot melt adhesion method and then their adsorption properties were investigated. ion exchange capacity and water content of hybrid ion exchange fibers increased as compared with those of bead and ion exchange fiber. Their maximum values were 4.76 meq/g and 23.5%, respectively. Adsorption breakthrough time for mercury of hybrid ion exchange fiber was slower than those of bead resin and fibrous ion exchanger. It's value was 130 minutes. Their breakthrough time become short as increasing of pH, and concentration. The initial breakthrough time was observed before and after 10 minutes as increasing of concentration. The adsorption of hybrid ion exchange fibers for $Hg^{2+}\;Pb^{2+},\;Cd^{2+}$ among heavy metals in the mixed solution was observed before 20 min. And also, The adsorption for $Hg^{2+}$ among the heavy metals by hybride ion exchange fibers was observed.

Studies on the effects of radiation from radioisotopes incorporated in plant (IV) -The effects of P-32 application on the growth of buckwheat- (작물에 흡수된 방사성 동위원소의 내부 조사 효과에 관한 연구 (IV) -교맥 생장에 미치는 P-32 시용의 잔유 효과-)

  • 김길환
    • Journal of Plant Biology
    • /
    • v.11 no.1
    • /
    • pp.7-14
    • /
    • 1968
  • Buckwheat seeds produced in previous year (1965) in an experimental pot culture in which nine levels of P-32 ranging from $1.4{\times}10-4 to 3.3{\times}104$\mu$c/pot(as of 27 July 1965)$, with the same specific activity, had been applied to the corresponding pots respectively, were used this year(1996) in water and soil culture as well as in germination test to investigate the feature and extent of possible residual effects of P-32 incorporated upon germination and plant growth, and the following results were obtained: 1. Under the given experimental conditions both stimulative and inhibitory effects of radiation were observed. 2. The germination rate of the seeds was lower at the higher level of P-32 aplication ranging from $3.0{\times}103 to 3.3{\times}104$\mu$c/pot$ and higher at 0.2 $\mu$c P/pot than the control. 3. Among the seeds produced at the higher level of application about 80% was failed to germinate, owing to the radiation injury. The remaining 80% was failed to germinate, owing to the radiation injury. The remaining 80% survived the damaging effect and showed vigorous growth and increased yield. The latter group of seeds thus proved themselves to be more radioresistant than the former. 4. The survived seeds produced later more straw and root on dry weight basis. The higher the level of P-32 applied, the stronger the stimulative effect showed in vegetative growth. 5. No radiation effect on linear growth of the plants was observed in the soil culture. 6. The dry weight of straw produced showed little difference at the moderate range compared with that of control in the soil culture. At high level of application, i.e. over $\mu$c P32/pot, however, the production was increased by 12-37% of control. 7. As for the dry weight of root harvested, the P-32 treatment over 24$\mu$c P32/pot produced 82-155% more than the control, whereas little difference was observed under 2.2$\mu$c P32/pot. 8. The seed production increased in general by the P-32 treatments. Particularly at the moderate level of application the rate of increase amounted to 70% of the control. 9. Those individual plants which survived damaging effects of radiation at the germinating stage shwoed remarkable stimulative effects both in vegetative and in reproductive stage of growth.

  • PDF