• 제목/요약/키워드: Radiofrequency (RF)

검색결과 96건 처리시간 0.027초

A Review on the RF Coil Designs and Trends for Ultra High Field Magnetic Resonance Imaging

  • Hernandez, Daniel;Kim, Kyoung-Nam
    • Investigative Magnetic Resonance Imaging
    • /
    • 제24권3호
    • /
    • pp.95-122
    • /
    • 2020
  • In this article, we evaluated the performance of radiofrequency (RF) coils in terms of the signal-to-noise ratio (S/N) and homogeneity of magnetic resonance images when used for ultrahigh-frequency (UHF) 7T magnetic resonance imaging (MRI). High-quality MRI can be obtained when these two basic requirements are met. However, because of the dielectric effect, 7T magnetic resonance imaging still produces essentially a non-uniform magnetic flux (|B1|) density distribution. In general, heterogeneous and homogeneous RF coils may be designed using electromagnetic (EM) modeling. Heterogeneous coils, which are surface coils, are used in consideration of scalability in the |B1| region with a high S/N as multichannel loop coils rather than selecting a single loop. Loop coils are considered state of the art for their simplicity yet effective |B1|-field distribution and intensity. In addition, combining multiple loop coils allows phase arrays (PA). PA coils have gained great interest for use in receiving signals because of parallel imaging (PI) techniques, such as sensitivity encoding (SENSE) and generalized autocalibrating partial parallel acquisition (GRAPPA), which drastically reduce the acquisition time. With the introduction of a parallel transmit coil (pTx) system, a form of transceiver loop arrays has also been proposed. In this article, we discussed the applications and proposed designs of loop coils. RF homogeneous coils for volume imaging include Alderman-Grant resonators, birdcage coils, saddle coils, traveling wave coils, transmission line arrays, composite right-/left-handed arrays, and fusion coils. In this article, we also discussed the basic operation, design, and applications of these coils.

MR Imaging-Histopathologic Correlation of Radiofrequency Thermal Ablation Lesion in a Rabbit Liver Model: Observation during Acute and Chronic Stages

  • Jong Deok Lee;Jeong Min Lee;Sang Won Kim;Chong Soo Kim;Woo Sung Mun
    • Korean Journal of Radiology
    • /
    • 제2권3호
    • /
    • pp.151-158
    • /
    • 2001
  • Objective: To determine the ability of MR imaging to detect the pathological changes occurring in radiofrequency (RF) thermal lesions and to assess its accuracy in revealing the extent of tissue necrosis. Materials and Methods: Using an RF electrode, thermal lesions were created in the livers of 18 rabbits. The procedure involved three phases. In the acute phase, six animals were killed the day after performing thermal ablation with RF energy, and two on day 3. In the subacute and chronic phases, eight rabbits underwent percutaneous hepatic RF ablation. After performing MR imaging, two animals were sacrificed at 1, 2, 4, and 7 weeks after the procedure, and MRpathologic correlation was performed. Results: In the acute phase, the thermal ablation lesions appeared at gross examination as well-circumscribed, necrotic areas, representing early change in the coagulative necrosis seen at microscopic examination. They were hypointense on T2-weighted images, and hyperintense on T1-weighted images. Gadolinium-enhanced MR imaging showed that a thin hyperemic rim surrounded the central coagulative necrosis. In the subacute phase, ablated lesions also showed extensive coagulative necrosis and marked inflammation at microscopic examination. Beyond two weeks, the lesions showed gradual resorption of the necrotic area, with a peripheral fibrovascular rim. The size of lesions measured by MR imaging correlated well with the findings at gross pathologic examination. Conclusion: MR imaging effectively demonstrates the histopathological tissue change occurring after thermal ablation, and accurately determines the extent of the target area.

  • PDF

Thermal Property Measurement of Swine Atrium

  • ;김지연
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권5호
    • /
    • pp.343-347
    • /
    • 2008
  • Thermal conductivity, thermal diffusivity were measured in the atrium of a swine heart. Radiofrequency (RF) catheter ablation in an atrium has rapidly emerged at the treatment of symptomatic reentrant arrhythmia associated with accessory pathway or Atrioventricular (AV) node conduction. The thermal properties of an atrium are definitely necessary for these treatments because, in thermal treatments, conductivity and diffusivity are significant factors in the relationship between the applied RF power and the resulting atrium temperature rise. Thermal properties were measured using a self-heated thermistor probe. Thermistor probes were inserted into the tissue of interest and were used to supply heat within the tissue as well as to monitor the temperature rise in the tissue. The measurements were performed at temperatures of 25, 37, $50^{\circ}C$. Atrium thermal conductivity ranged from 5.17$\pm$0.12 mW/cm$^{\circ}C$ at $25^{\circ}C$ to 5.33$\pm$0.08 mW/cm$^{\circ}C$ at $37^{\circ}C$. Atrium thermal diffusivity ranged from 0.00132$\pm$0.00007$cm^2$/sec at $25^{\circ}C$ to 0.00138$\pm$0.00003 $cm^2$/sec at $50^{\circ}C$. This paper also present the thermal property comparison of both chambers of a heart (ventricle and atria).

Effect of Ginseng on Calretinin Expression in Mouse Hippocampus Following Exposure to 835 MHz Radiofrequency

  • Aryal, Bijay;Maskey, Dhiraj;Kim, Myeung-Ju;Yang, Jae-Won;Kim, Hyung-Gun
    • Journal of Ginseng Research
    • /
    • 제35권2호
    • /
    • pp.138-148
    • /
    • 2011
  • Exponential rise in the use of mobile communication devices has generated health concerns due to radiofrequency (RF) exposure due to its close proximity to the head. Calcium binding proteins like calretinin regulate the levels of calcium ($Ca^{2+}$) which plays an important role in biological systems. Ginseng is known for maintaining equilibrium in the human body and may play a beneficial radioprotectant role against electromagnetic field (EMF) exposure. In the present study, we evaluated the radioprotective effects of red ginseng (RG) extract in a mouse model. Calretinin (CR) expression was measured using a free-floating immunohistochemical method in the hippocampus of mice after 835 MHz EMF exposure for 5 h/d for 5 d at specific absorption rate=1.6 W/kg for the different experimental groups. The control animals were treated with NaCl while the experimental animals received 10 mg/kg ginseng, or 30 mg/kg; EMF exposed mice were also treated with NaCl, 10 mg/kg ginseng (E10), or 30 mg/kg (E30). Decreases in CR immunoreactivity (IR) along with loss of CA1 and CA3 interneurons and infragranular cells were observed in the ENaCl group while such losses were not observed in the E10 and E30 groups. CR IR significantly increased in the RG-treated group compared to control and EMF-exposed groups treated with NaCl. The study demonstrates that RG extract can serve as a radioprotective agent that maintains $Ca^{2+}$ homeostasis and prevents neuronal loss in the brain hippocampal region caused by RF exposure.

고주파 유전가열형 온열암치료기의 개발과 가온특성 (DEVELOPMENT and THERMAL DISTRIBUTION of an RF CAPACITIVE HYPERTHERMIA SYSTEM)

  • 박민용;이상배;박덕규;추성실;정미향
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(II)
    • /
    • pp.1309-1312
    • /
    • 1987
  • Hyperthermia for the treatment of cancer has been introduced for a long time and the biological effect for the use of hyperthermia to malignant tumors has been well established and encouraging clinical results has been observed. Unfortunately, the engineering or technical aspects of hyperthermia for the deep seated tumors has not been satisfactory. We have researched and developed the radiofrequency capacitive hyperthermia system (GHT- RF8). It was composed with 8-9 MHZ RF generator, capacitive electrode, matching system, cooling system, temperature measuring system and control computer. The thermal profile was investigated in agar phantom, animals and in human tumors, which was heated with capacitive RF device.

  • PDF

도심지역 노인복지시설 실내 환경에 대한 RF 전자파 노출량의 정성.정량 평가에 관한 연구 (Assessment for Ingredients and Amount of Radiofrequency Electromagnetic Field Exposure for Indoor Environment in an Institution for the Aged of Downtown)

  • 최정훈;김남;홍승철;김윤신;최성호
    • 한국환경보건학회지
    • /
    • 제32권4호
    • /
    • pp.268-274
    • /
    • 2006
  • In this study in order to evaluate the growth of RF propagation exposure rate generated according to the enhancement of its use, it is proposed for the ground to be able to examine and to contemplate the correlation between the human health and RF propagation exposure rate by measuring and analyzing the RF exposure source and exposure rate in an indoor environment. As a result of research, it is analyzed that the main exposure source of critically making effect in indoor environment is the frequency hand if radio broadcasting, mobile communication, wireless LAN, digital broadcasting, home appliance, etc., including the TV broadcasting. Among these, it is shown that the TV broadcasting and mobile communication band are the highest. And it is the concluded that RF exposure rate of the environmental sensitive equipment, like an institution for the aged, has lower possibility to exceed the human RF protection criteria by this evaluation.

Hexamethyldisiloxane 플라즈마 중합막을 통한 영구기체 및 응축성 증기의 투과특성에 관한 연구 (A Study on the Permeation Properties of Permanent Gases and condensable Vapors through Hexamethyldisiloxane Plasma-Polymerized Membranes)

  • 오세중
    • 한국산학기술학회논문지
    • /
    • 제19권3호
    • /
    • pp.699-706
    • /
    • 2018
  • 플라즈마 고분자의 영구기체(He, $H_2$, $O_2$, $N_2$, $CH_4$) 및 응축성 증기($CO_2$, $C_2H_4$, $C_3H_8$)에 대한 투과 특성을 조사하였다. 플라즈마 고분자는 마이크로파 방전과 라디오파 방전을 이용하여 제조하였으며 플라즈마 중합의 단량체(monomer)로는 hexamethyldisiloxane(HMDS)을 사용하였다. 마이크로파를 이용하여 제조한 HMDS 플라즈마 고분자막의 투과도계수는 투과 기체의 분자지름에 의존하는 경향을 나타내었으며 라디오파를 이용하여 제조한 플라즈마 고분자막보다 높은 산소/질소 투과선택도를 나타내었다. 반면에 라디오파를 이용하여 제조한 HMDS 플라즈마 고분자막의 투과도계수는 투과기체의 임계온도에 의존하는 경향을 나타내었으며 질소에 대한 에틸렌 및 프로판의 투과선택도가 우수한 특성을 나타내었다. 마이크로파로 중합시킨 고분자막은 가교결합도가 높기 때문에 기체의 투과도계수가 주로 확산계수(또는 분자지름)에 의존하게 된다. 그러나 라디오파의 에너지 밀도는 마이크로파의 에너지 밀도보다 낮기 때문에 라디오파로 중합시킨 플라즈마 고분자막의 구조는 마이크로파로 중합시킨 고분자 막에 비하여 가교결합도가 떨어지게 되며 이 막을 통한 투과도계수는 분자크기 보다는 기체의 임계온도에 의존하는 경향을 나타내었다. 따라서 라디오파를 이용하여 중합시킨 HMDS 플라즈마 고분자막은 영구기체 보다는 공기 중의 유기물질을 제거하는데 보다 효과적으로 이용될 수 있을 것으로 생각된다.

Children's Mobile Phone Use and Dosimetry

  • Lee, Ae-Kyoung;Kwon, Jong-Hwa
    • Journal of electromagnetic engineering and science
    • /
    • 제15권3호
    • /
    • pp.167-172
    • /
    • 2015
  • Research results on possible effects caused by radiofrequency fields in children are limited because most of the studies published so far have focused on adults, rather than children. Mobile phone use is now widespread, even among younger children. If a biological risk due to mobile phone exposure is found, it might be greater in children because their bodies might be more sensitive to radiofrequency energy. The issue of a possible difference in sensitivity between adults and children begins with whether any difference exists physically in terms of electromagnetic absorption. This paper presents a review of recent publications on dosimetric comparisons between children and adults with respect to radiation from mobile phones. The issue of the health effects of mobile phone use is beyond the scope of the present review. Most of the dosimetry research on possible differences in power absorption between children and adults has been based on numerical modeling and analysis. The understanding of the results so far is presented and needed studies are described.

Detrimental impact of cell phone radiation on sperm DNA integrity

  • Yeganeh Koohestanidehaghi;Mohammad Ali Khalili;Fatemeh Dehghanpour;Mohammad Sei
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제51권1호
    • /
    • pp.13-19
    • /
    • 2024
  • Radiofrequency electromagnetic radiation (RF-EMR) from various sources may impact health due to the generation of frequency bands. Broad pulses emitted within frequency bands can be absorbed by cells, influencing their function. Numerous laboratory studies have demonstrated that mobile phones-generally the most widely used devices-can have harmful effects on sex cells, such as sperm and oocytes, by producing RF-EMR. Moreover, some research has indicated that RF-EMR generated by mobile phones can influence sperm parameters, including motility, morphology, viability, and (most critically) DNA structure. Consequently, RF-EMR can disrupt both sperm function and fertilization. However, other studies have reported that exposure of spermatozoa to RF-EMR does not affect the functional parameters or genetic structure of sperm. These conflicting results likely stem from differences among studies in the duration and exposure distance, as well as the species of animal used. This report was undertaken to review the existing research discussing the effects of RF-EMR on the DNA integrity of mammalian spermatozoa.

고주파열응고술을 이용한 요부교감신경절제술에서 수술기주위의 온도변화 (Perioperative Temperature Changes Observed in Cases of Lumbar Sympathectomy Using RF Thermocoagulation)

  • 정배희;신근만;김현주;이기헌;김태성;홍순용;최영룡
    • The Korean Journal of Pain
    • /
    • 제13권2호
    • /
    • pp.196-201
    • /
    • 2000
  • Background: Currently, minimally invasive operations are preferred to open surgery whenever possible. Lumbar sympathectomy using RF (radiofrequency) thermocoagulation is both safe and minimally invasive. The problem with the technique is that it cannot be performed successfully in a significant number of cases. If the temperature change in the sole is monitored immediately after the procedure then it can be determined if the procedure needs to be repeated. Methods: A curved tip cannula, 150 mm long with a 10 mm active tip, was used for RF lumbar sympathectomy. The temperature of the soles of both the foot on the affected side and the foot on the control side was monitored immediately before the procedure, immediately after making the L2 lesion, immediately after making the L3 lesion and at 5, 10, and 15 minutes after the procedure. Results: No statistically significant difference was observed in the temperature of the two soles before making the lesions. In the 24 of the 27 patients, there were prominent differences in temperature between the two soles at 10 minutes after the procedures. 11 of the 24 patients showed a significant temperature change after the first trial. But the remaining 13 required a second lesion on L2 and L3. Conclusions: We judged the success of the operation in the operating room by monitoring the temperature difference in the soles of the feet. When no increase in the temperature difference is observed, we can move the electrode and make another lesion. With this procedure, we can drastically increase the success rate of the procedure.

  • PDF