• Title/Summary/Keyword: Radioactive

Search Result 7,917, Processing Time 0.031 seconds

Study of Iodide Adsorption on Organobentonite using X-ray Absorption Spectroscopy (X-선 흡수분광기를 이용한 유기벤토나이트의 요오드 흡착연구)

  • Yoon, Ji-Hae;Ha, Ju-Young;Hwang, Jin-Yeon;Hwang, Byoung-Hoon;Gordon E. Brown, Jr.
    • Journal of the Mineralogical Society of Korea
    • /
    • v.22 no.1
    • /
    • pp.23-34
    • /
    • 2009
  • The adsorption of iodide on untreated bentonite and bentonites modified with organic cation (i.e., hexadecylpyridinium chloride monohydrate ($HDP^+$)) was investigated, and the organobentonites were characterized using uptake measurements, ${\mu}$-XRD, and electrophoretic mobilities measurement. Uptake measurements indicate that bentonite has a high affinity for $HDP^+$. Our ${\mu}$-XRD study indicates that organobentonites significantly expanded in basal spacing and organic cations were substantially intercalated into the interlayer spaces of bentonite. The electrophoretic mobility indicates that organobentonite tht is modified with organic cations in excess of the CEC of bentonite is completely different from untreated bentonite in the surface charge distribution. We found significant differences in adsorption capacities of iodide depending on the bentonite properties as follows: iodide adsorption capacities were 439 mmol/kg for the bentonite modified with $HDP^+$ at an equivalent amount corresponding to 200% of the CEC of bentonite whereas no adsorption of iodide was observed for the untreated bentonite. The molecular environments of iodine adsorbed on organobentonites were further studied using I K-edge and $L_{III}$-edge x-ray absorption spectroscopy (XAS). The X-ray absorption near-edge structure (XANES) of iodine spectra from organobentonites was similar to that of KI reference solution. Linear combination fitting of EXAFS data suggests the fraction of iodine reacted with the organic compound increased with increasing loading of the organic compound on organobentonites. In this study, we observed significant differences in the adsorption environments of iodide depending on the modified property of bentonite and suggest that an organobentonite has potential as reactive barrier material around a nuclear waste repository containing anionic radioactive iodide.

Relation of Self-Efficacy and Cognition of Irradiated Food among High School Students (고등학생의 방사선조사식품에 대한 인식과 자기효능감과의 관련성)

  • Han, Eun Ok;Choi, Yoon Seok
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.2
    • /
    • pp.106-118
    • /
    • 2013
  • In this paper, we analyzed the Cognition of irradiated food and its relation with self-efficacy. The most important variables described behaviors based on health choices compared with the choice to choose irradiated food items. According to the survey, 33.1% of respondents said that the reason why irradiated food is considered to be a health risk is because "radiation is dangerous". 27.9% of respondents answered that "eating irradiated food is like eating a radioactive substance", 21.1% said radiated food is comparable to a "genetic variation in food" while 10.1% said "food goes bad during the irradiation process". On this basis, it is reasonable to conclude that respondents have a misunderstanding of irradiated food without reference to the general theory of irradiated knowledge. In this respect, it would be helpful to provide education showing that irradiated food is not related to eating harmful or genetically modified food to help high school students create informed opinions of irradiated food. In terms of relevance with health-specific self-efficacy, experience of acquiring information about irradiated food was marked at r=0.148 (p<0.01), experience of purchasing irradiated food was marked at r=0.077 (p<0.05), experience of eating irradiated food was marked at r=0.113 (p<0.01) while knowledge of irradiated food, attitude towards irradiated food and behavior was marked at r=0.103 (p<0.01), r=0.076 (p<0.05) and r=0.105 (p<0.01) respectively. This shows that self-efficacy is high when one has experience of acquiring information about irradiated food, purchasing or eating irradiated food resulting in a high level of knowledge, attitude and behavior. Education which serves to improve the level of self-efficacy needs to be provided along with an educational program which will increase the public's understanding of irradiated food. It is expected that if this education which increases the level of self-efficacy is provided together with correct information of irradiated food, behavior to choose and eat irradiated food will also improve.

Evaluating the Impact of Attenuation Correction Difference According to the Lipiodol in PET/CT after TACE (간동맥 화학 색전술에 사용하는 Lipiodol에 의한 감쇠 오차가 PET/CT검사에서 영상에 미치는 영향 평가)

  • Cha, Eun Sun;Hong, Gun chul;Park, Hoon;Choi, Choon Ki;Seok, Jae Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.67-70
    • /
    • 2013
  • Purpose: Surge in patients with hepatocellular carcinoma, hepatic artery chemical embolization is one of the effective interventional procedures. The PET/CT examination plays an important role in determining the presence of residual cancer cells and metastasis, and prognosis after embolization. The other hand, the hepatic artery chemical embolization of embolic material used lipiodol produced artifacts in the PET/CT examination, and these artifacts results in quantitative evaluation influence. This study, the radioactivity density and the percentage error was evaluated by the extent of the impact of lipiodol in the image of PET/CT. Materials and Methods: 1994 NEMA Phantom was acquired for 2 minutes and 30 seconds per bed after the Teflon, water and lipiodol filled, and these three inserts into the enough to mix the rest behind radioactive injection with $20{\pm}10MBq$. Phantom reconfigure with the iterative reconstruction method the number of iterations for two times by law, a subset of 20 errors. We set up region of interest at each area of the Teflon, water, lipiodol, insert artifact occurs between regions, and background and it was calculated and compared by the radioactivity density(kBq/ml) and the% Difference. Results: Radioactivity density of the each region of interest area with the teflon, water, lipiodol, insert artifact occurs between regions, background activity was $0.09{\pm}0.04$, $0.40{\pm}0.17$, $1.55{\pm}0.75$, $2.5{\pm}1.09$, $2.65{\pm}1.16 kBq/ml$ (P <0.05) and it was statistically significant results. Percentage error of lipiodol in each area was 118%, compared to the water compared with the background activity 52%, compared with a teflon was 180% of the difference. Conclusion: We found that the error due to under the influence of the attenuation correction when PET/CT scans after lipiodol injection performed, and the radioactivity density is higher than compared to other implants, lower than background. Applying the nonattenuation correction images, and after hepatic artery chemical embolization who underwent PET/CT imaging so that the test should be take the consideration to the extent of the impact of lipiodol be.

  • PDF

The Evaluation of Usefulness of 99Mo-99mTc Generator Using(n,γ)99Mo Developed by Korea Atomic Energy Research ((n,γ)99Mo를 이용한 99Mo-99mTc발생기의 유용성 평가)

  • Seo, Han Kyung;Kim, Jeong Ho;Shim, Cheol Min;Kim, Byung Cheol;Choi, Do Cheol;Gwon, Yong Ju;Park, Yung Sun;Kim, Dong Yun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.48-52
    • /
    • 2013
  • Purpose: The Molybdenum which is the raw material of $^{99}Mo-^{99m}Tc$ generator is produced from the nuclear reactor. However, output has dwindled as the two nuclear reactors supplying the bulk of radioactive material-one in Chalk River, Ontario and the other in Petten, the Netherlands-have been closed for repairs or maintenance. This resulted in the enhancement of its price. So $^{99}Mo-^{99m}Tc$ generator using$(n,{\gamma})^{99}Mo$ is developed by Korea Atomic Energy Research Institute (KAERI). Medicinal availability of this generator is evaluated in this study. Materials and Methods: The radioactivity of $^{99m}Tc$ eluted in generator 1, 2 and 3 unit developed by KAERI was measured. The quality control test of generator such as appearance test, pH test, LAL test, sterility test, chemical impurity (Al) test and radiochemical purity test were performed. Planar and SPECT/CT image sof SD rat (6 weeks, Female) at 2 hr after injection of $^{99m}Tc-HDP$ (hydroxymethylenediphosphonate) (TechneScan HDP, Malinckrodt Medical, Dutch) and $^{99m}Tc-DPD$ (diphosphono-1, 2-propanedicarboxylicacid) (TECEOS, CIS bio international, France) which were labeled with $^{99m}Tc$ eluted in KAERI and commercial generator (40.5 GBq, Malinckrodt Medical, Dutch) using SPECT/CT camera (Symbia, Siemense, Germany) were obtained respectively. Results: The mean radioactivity of $^{99m}Tc$ elution generator 1unit was 4.18 GBq (113 mCi), generator 2 unit was 4.73 GBq (128 mCi) and generator 3 unit was 3.33 GBq (90 mCi). All quality control tests were within normal limit except pyrogentest. Pyrogen test was positive. Planar and SPECT/CT images of rat injected $^{99m}Tc-HDP$ which was labeled with $^{99m}Tc$ eluted in commercial generator show increased uptake in bone, stomach and bowl. Planar images show increased uptake in liver and bone in case of $^{99m}Tc-DPD$. However, images of rat injected $^{99m}Tc-HDP$ and $^{99m}Tc-DPD$ which were labelled $^{99m}Tc$ eluted in KAERI generator show increased uptake in bone, liver and spleen. Conclusion: If shortcoming is removed such as pyrogen and liver appearance, domestic role as an alternative generator is thought to be able to fill and to secure the national medical service by supplying $^{99m}Tc$ when the supply of $^{99m}Tc$ be comes short.

  • PDF

The Evaluation of Image Correction Methods for SPECT/CT in Various Radioisotopes with Different Energy Levels (SPECT/CT에서 서로 다른 에너지의 방사성동위원소 사용시 영상보정기법의 유용성 평가)

  • Shin, Byung Ho;Kim, Seung Jeong;Yun, Seok Hwan;Kim, Tae Yeop;Lim, Jung Jin;Woo, Jae Ryong;Oh, So Won;Kim, Yu Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.53-58
    • /
    • 2013
  • Purpose: To optimize correction method for SPECT/CT, image quality consisting of resolution and contrast was evaluated using three radioisotopes ($^{99m}Tc$, $^{201}Tl$ and $^{131}I$) and three different correction methods; attenuation correction (AC), scatter correction (SC) and both attenuation and scatter correction (ACSC). Materials and Methods: Images were acquired with a SPECT/CT scanner and a conventional CT protocol with an OESM reconstruction algorithm (2 iterations and 10 subsets). For resolution measurement, fixed radioactivity (2.22 kBq) was infused into a spatial resolution phantom and full width at half maximum (FWHM) was measured using a vendor-provided software. For contrast evaluation, radioactive source with a ratio of 1:8 to background was filled in a Flanged Jaszczak phantom and percent contrast (%) were calculated. All the parameters for image quality were compared with non-correction (NC) method. Results: As compared with NC, image resolution of all three isotopes were significantly improved by AC and ACSC, not by SC. In particular, ACSC showed better resolution than AC alone for $^{99m}Tc$ and $^{201}Tl$. Image contrast of all three radioisotopes in a sphere with the largest diameter were enhanced by all correction methods. ACSC showed the highest contrast in all three radioisotopes, which was the most accurate in $^{99m}Tc$ (85.9%). Conclusion: Image quality of SPECT/CT was improved in all the radioisotopes by CT-based attenuation correction methods, except SC alone. SC failed to improve resolution in any radioisotopes, but it was effective in contrast enhancement. ACSC would be the best correction method as it improved resolution in radioisotopes with low energy levels and contrast in radioisotope with low energy levels. However, in radioisotope with high energy level, AC would be better than ACSC for resolution improvement.

  • PDF

Screening and Identification of a Cesium-tolerant Strain of Bacteria for Cesium Biosorption (환경유래의 세슘 저항성 균주 선별 및 세슘 흡착제거 연구)

  • Kim, Gi Yong;Jang, Sung-Chan;Song, Young Ho;Lee, Chang-Soo;Huh, Yun Suk;Roh, Changhyun
    • Korean Journal of Environmental Biology
    • /
    • v.34 no.4
    • /
    • pp.304-313
    • /
    • 2016
  • One of the issues currently facing nuclear power plants is how to store spent nuclear waste materials which are contaminated with radionuclides such as $^{134}Cs$, $^{135}Cs$, and $^{137}Cs$. Bioremediation processes may offer a potent method of cleaning up radioactive cesium. However, there have only been limited reports on $Cs^+$ tolerant bacteria. In this study, we report the isolation and identification of $Cs^+$ tolerant bacteria in environmental soil and sediment. The resistant $Cs^+$ isolates were screened from enrichment cultures in R2A medium supplemented with 100 mM CsCl for 72 h, followed by microbial community analysis based on sequencing analysis from 16S rRNA gene clone libraries(NCBI's BlastN). The dominant Bacillus anthracis Roh-1 and B. cereus Roh-2 were successfully isolated from the cesium enrichment culture. Importantly, B. cereus Roh-2 is resistant to 30% more $Cs^+$ than is B. anthracis Roh-1 when treated with 50 mM CsCl. Growth experiments clearly demonstrated that the isolate had a higher tolerance to $Cs^+$. In addition, we investigated the adsorption of $0.2mg\;L^{-1}$ $Cs^+$ using B. anthracis Roh-1. The maximum $Cs^+$ biosorption capacity of B. anthracis Roh-1 was $2.01mg\;g^{-1}$ at pH 10. Thus, we show that $Cs^+$ tolerant bacterial isolates could be used for bioremediation of contaminated environments.

Study on Overcoming Interference Factor by Automatic Synthesizer in Endotoxin Test (내독소 검사에서 자동합성장치에 따른 간섭요인 극복에 대한 연구)

  • Kim, Dong Il;Kim, Si Hwal;Chi, Yong Gi;Seok, Jae Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.3-6
    • /
    • 2012
  • Purpose : Samsung medical ceter shall find a cause of the interference factor and suggest a solution for it. Materials and Methods : A sample of $^{18}F$-FDG, radioactive pharmaceuticals produced by TRACERlab MX and FASTlab synthesizer. Gel-clot method uses Positive control tube and single test tube. Kinetic chromogenic method uses ENDOSAFE-PTS produced by Charles River. Results : According to Gel clot method of Endotoxin Tests at FASTlab, both turbidity and viscosity increased at 40-fold dilution and Gel clot was detected. In case of TRACERlab MX, Gel clot was detected in most of samples but intermittently not in a few of them. When using ENDOSAFE-PTS, sample CV (Coefficient of Variation) of FASTlab is 0% at all dilution rates whereas spike CV is 0% at 1-fold dilution, 0~35% at 10-fold, 3.6~12.9% at 20-fold, 5.2~7.1% at 30-fold, 1.1~17.4% at 40-fold, spike recovery; 0% at one-fold, 25 ~ 58% at 10-fold, 50 ~ 86% at 20-fold, 70~92% at 30-fold, and 75~120% at 40-fold. Sample CV of TRACERlab MX, is 0% at all dilution rates whereas spike CV is 1.4~4.8% at one-fold dilution, 0.6~19.9% at 10-fold, spike recovery; 35~72% at one-fold dilution and 77~107% at 10-fold. Conclusion : Gel clot does not seem to occur probably to H3PO4 which engages in bonding with Mg2+ion contributing gelation inside PCT. Dilution which is identical to reducing the amount of H3PO4, could remove interfering effects accordingly. Spike recovery was obtained within 70~150% - recommended values of supplier - at 40-fold dilution even in kinetic chromogenic method.

  • PDF

A study on the Hematologic Effects of Radioactive Iodine($^{131}I$) Therapy on Various Thyroid Diseases (방사성동위원소옥소(放射性同位元素沃素)($^{131}I$)의 치료량(治療量)이 갑상선종환자(甲狀腺腫患者)의 혈액상(血液像)에 미치는 영향(影響)에 관(關)한 연구(硏究))

  • Kim, Myung-Jae;Kim, Noe-Kyeong;Lee, Jung-Sang;Choi, Keun-Chul;Lee, Ryong-Woo;Kim, Kee-Won;Kang, Shin-Il
    • The Korean Journal of Nuclear Medicine
    • /
    • v.3 no.1
    • /
    • pp.51-58
    • /
    • 1969
  • To clarify the hematologic effects of the radioiodine ($^{131}I$) in therapeutic doses ($5{\sim}10$ mCi) on the various thyroid patients, authors studied the peripheral blood pictures of 396 goitrous patients before and after radioiodine ($^{131}I$) administrations in the Isotope Clinic of Seoul National University Hospital. Among these 396 cases of goiters, we gave 5 to 10 mCi of radioiodine ($^{131}I$) with single or fractionated administrations. The blood pictures of peripheral blood were repeated after 3 months in 40 cases of 65 cases who had been treated with $^{131}I$. The blood pictures of non-treated thyroid patients were compared with that of normal Korean values to clarify any difference between normal and goiter. The blood pictures of hyperthyroid patients treated with $^{131}I$ therapy were compared with the blood pictures of non-treated thyroid patients. The results were as following: 1) The incidence according to type: Toxic diffuse goiter: 35.4% Nontoxic nodular goiter: 29.7% Euthyroid: 13.8% Nontoxic diffuse goiter: 12.6% Hypothyroidism: 4.3% Thyroiditis($\bar{s}$ subacute form): 1.8% Toxic nodular goiter: 1.4% Malignancy: 1.0% 2) Age incidence: The range of distribution was 11 to 71 years. The peak incidence was found in the 4th decade of life. $80.6{\sim}82.6%$ of those 396 cases were found among the 3rd, 4th and the 5th decades of life. 3) Sex incidence: Sex ratio of male:female was 1:7.8. 4) The most outstanding findings in peripheral blood before treatment were decreased erythrocyte count and hemoglobin value in all types of thyroid diseases, especially in. the cases of hypothyroidism and thyroiditis. Hook worm-infested patients showed no significant difference in erythrocytes and hemoglobin values from those of other hook worm free patients. 5) Total leukocytes count was within normal range. Differential count of W.B.C. showed increased percentile of lymphocyte in diffuse toxic goiter and thyroiditis. 6) 39 cases of diffuse goiter treated with $^{131}I$ toxic showed amelioration in the anemia and restoration to normal range of lymphocyte count in association with increased percentile of neutrophiles 3 months after administration, except a case of toxic nodular goiter. One can observe anemia in slight degree, and increased lymphocytes count in hypothyroidism. Therapeutic dose of radioiodine ($^{131}I$) does not result any residual effect on the hematopoietic function. Radioiodine ($^{131}I$) therapy resulted in improvement of thyroid function in association of amelioration of pevious abnormal blood pictures. 7) Authors did not observe any myxedema resulted from radioiodine therapy during the 3 months period in this study.

  • PDF

Hydrogeochemical Characteristics, Occurrence, and Distribution of Natural Radioactive Materials (Uranium and Radon) in Groundwater of Gyeongnam and Gyeongbuk Provinces (경상남북도 지하수 중 자연방사성물질 우라늄과 라돈의 산출특징과 함량분포에 대한 수리지화학적 연구)

  • Cho, Byong Wook;Choo, Chang Oh;Yun, Uk;Lee, Byeong Dae;Hwang, Jae Hong;Kim, Moon Su
    • The Journal of Engineering Geology
    • /
    • v.24 no.4
    • /
    • pp.551-574
    • /
    • 2014
  • The occurrence, distribution, and hydrogeochemical characteristics of uranium and radon in groundwater within different lithologies in Gyeongnam and Gyeongbuk provinces were investigated. A total of 201 groundwater samples from sedimentary rocks taking a large portion of the geology and from igneous rocks taking a small portion of the geology were analyzed and examined using factor analysis. Their radionuclide levels were used to construct detailed concentration maps. The groundwater types, defined using a Piper diagram, are mainly Ca-$HCO_3$ with less Na-$HCO_3$. Among the samples, one site exceeds $30{\mu}g/L$ of uranium (i.e., the maximum contaminant level of the USEPA) and three sites exceed 4,000 pCi/L of radon (i.e., the alternative maximum contaminant level). No samples were found to exceed the 15 pCi/L level of gross alpha or the 5 pCi/L level of radium. The concentration of uranium ranges from 0.02 to $53.7{\mu}g/L$, with a mean of $1.56{\mu}g/L$, a median of $0.47{\mu}g/L$, and a standard deviation of $4.3{\mu}g/L$. The mean concentrations of uranium for the different geological units increase in the following order: Shindong Group, Granites, Hayang Group, Yucheon Group, and Tertiary sedimentary rocks. The concentration of radon ranges from 2 to 8,740 pCi/L, with an mean of 754 pCi/L, a median of 510 pCi/L, and a standard deviation of 907 pCi/L. The mean radon concentrations for the investigated geological units increase in the following order: Granites, Yucheon Group, Tertiary sedimentary rocks, Hayang Group and Shindong Group. According to the factor analysis for each geological unit, uranium and radon behave independently of each other with no specific correlation. However, radionuclides show close relationships with some components. Regional investigations of radionuclides throughout the country require an integrated approach that considers the main lithological units as well as administrative districts.

A Study on Dose Assessment by 18F-FDG injected into Patients (환자에게 주입된 18F-FDG 의한 선량 평가에 대한 연구)

  • Kim, Chang-Ju;Kim, Jang-Oh;Jeong, Geun-Woo;Shin, Ji-Hey;Lee, Ji-Eun;Jeon, Chan-Hee;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.467-475
    • /
    • 2020
  • The purpose of this study is to assess doses to 18F-FDG, a radioactive drug, during PET examinations, to alleviate anxiety about radiation in patients and carers, to minimize the indiscriminate examination progress caused by medical institution personnel and space clearance problems, and health examination. The dose assessment was measured using a thermo-fluorescent dosimeter (TLD) and an electronic personal dosimeter (EPD) at the location of the cervical (hypothyroid), thorax (heart), and lower abdomen (breeding line) which are the three highest tissue areas of the radiation tissue weighting. In addition, spatial dose rates and radioactivity in urine were measured using GM counters and ion boxes. The results are as follows: First, the personal dosimeter TLD was measured 0.0425±0.0277 mSv in the cervical region, 0.0440±0.0386 mSv in the thorax and 0.0485±0.0436 mSv in the lower abdomen, with little difference in the heart dose depending on radiation sensitivity. The EPD was measured at 0.942±0.141 mSv/h immediately after the cervical position, and 0.192±0.031 mSv/h after 120 minutes. Immediately after the thorax position, 0.516±0.085 mSv/h, 120 minutes later 0.128±0.040 mSv/h. Immediately after the lower abdomen position, 0.468±0.091 mSv/h, and after 120 minutes 0.105±0.021 mSv/h were measured. The spatial dose rate at the GM counter was measured immediately at 0.041±0.005 mSv/h, 120 minutes later at 0.014±0.002 mSv/h. The radioactivity in urine using ion chamber was measured at 0.113±0.24 MBq/cc after 60 minutes and 0.063±0.13 MBq/cc after 120 minutes. As a result, 18F-FDG should be administered, dose re-evaluated two hours after the PET test is completed, and caregivers should be avoided. In addition, it is deemed necessary to provide patients and carers with sufficient explanations and expected values of exposure dose to avoid reckless testing. It is hoped that the data tested in this study will help patients and families relieve anxiety about radiation, and that the radiation workers' exposure management system and institutional improvements will contribute to the development of medical radiation.