• Title/Summary/Keyword: Radio-frequency stimulation

Search Result 16, Processing Time 0.031 seconds

Mouse Somatosensory Cortex Stimulation Using Pulse Modulated Transcranial Magnetic Stimulation (구형파 변조된 경두개 자기자극을 이용한 쥐의 감각피질 자극실험)

  • Sun, Sukkyu;Seo, Taeyoon;Huh, Yeowool;Cho, Jeiwon;Kwon, Youngwoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.5
    • /
    • pp.482-485
    • /
    • 2016
  • In this work, a transcranial magnetic stimulation(TMS) experiment on animals is performed to stimulate the brain cortex of the mouse using modulated signals. The proposed TMS system is composed of the inverter, transformer, capacitor, variable inductor, and stimulation coil to generate 1.5 mT magnetic field in the brain cortex of the mouse. The stimulation signal is modulated to square wave where the carrier frequency is swept from 85 to 91 kHz to investigate the stimulation effect. The experimental result shows that when the carrier frequency of the stimulation signal is lower than 89 kHz, the reaction of the mouse does not change while the stimulation signal which has the carrier frequency higher than 89 kHz results in decreasing the threshold of the stimulus for the pressure.

Design and Implementation of Medical Compound Stimulator Using Low/High Frequency and Cooling Stimulation (저주파/고주파와 냉자극을 이용한 의료용 조합 자극기의 설계 및 구현)

  • Yoon, Wan-Oh;Kang, Suk-Youb;Jung, Jin-Ha;Choi, Sang-Bang
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.1
    • /
    • pp.82-87
    • /
    • 2008
  • In this paper, the study was carried out to design and implement the medical compound stimulator based on the preexisting individual medical stimulators with Low frequency, High frequency and cooling stimulation. The proposed equipment is designed to compound all the functions including a cooling stimulation with a range of $0{\sim}20^{\circ}C$ and the verified low and high frequencies of 250Hz, 500Hz, 1KHz and 1MHz respectively from the previous clinical experiment with a consideration of its credibility and efficiency. Also, it was constructed by using a new technique, thermoelectricity semiconductor with a consideration of miniaturization and stability. In accordance with patients' treatment purpose, the hand piece of low frequency/cooling stimulation and High frequency/cooling stimulation were separately designed for convenience. The frequency, accuracy and other factors of implemented medical compound stimulator was satisfied according to its measurement. It was also tested by Korean Testing Laboratory (KTL) for its stability and efficacy and it confirmed that the medical compound stimulator is suitable for use as it fits in with the medical equipment standards.

Inhibition of Endothelial Cell-dependent Serotonin-induced Contraction of ${\beta}-endorphin$ and Increment of Plasma ${\beta}-endorphin$ of Silver Spike Point Low Frequency Electrical Stimulation (${\beta}-Endorphin$의 내피세포의존성-세로토닌 유도-근 수축 억제와 저빈도-주파수 은침점전자극의 혈장 ${\beta}-endorphin$ 증가)

  • Choi Young-Duk;Lee Joon-Hee;Kim Jung-Hwan
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.3
    • /
    • pp.22-31
    • /
    • 2004
  • The purpose of this study was to demonstrate the effects of silver spike point (SSP) low frequency electrical stimulation on plasma ${\beta}-endorphin$ activities measured by radio- immunoassay from normal volunteer and the effects of ${\beta}-endorphin$ on 5-hydroxytryptamine (5-HT, serotonin)-induced contraction investigated by isometric tension methode in rats. The current of 3 Hz continue type, but not 100 Hz continue type, of SSP low frequency electrical stimulation significantly increased in plasma ${\beta}-endorphin$ from normal volunteer. The endothelial cell-dependent 5-HT-induced contractions were inhibited by ${\beta}-endorphin$ $1{\mu}M$. These results suggest that the ${\beta}-endorphin$ regulates nociceptive-like substance, such as 5-HT, in part and that the SSP low frequency electrical stimulation, specifically current of low frequency of 3 Hz continue type, significantly increases plasma ${\beta}-endorphin$ from normal volunteer.

  • PDF

Analgesic Effects of Electroacupuncture, Warm Needling and Radio Frequency Warm Needling on Surgical Ankle Sprain Model in Rats (흰쥐의 발목염좌에 대한 전침, 온침 및 고주파온침 자극별 진통 효과의 비교)

  • Yang, Seung-Bum;Kim, Min-Su;Choi, Suck-Jun;Kim, Jae-Hyo
    • Korean Journal of Acupuncture
    • /
    • v.32 no.1
    • /
    • pp.20-29
    • /
    • 2015
  • Objectives : The objectives of this study is to compare the effects of electroacupuncture(EA), warm needling(WN) and Radio Frequency warm needling(RFWN) stimulations on the acupoints at the artificially damaged ankles of Sprague-Dawley rats, which could be classified as the Grade 3. Methods : The foot weight bearing force ratio(FWBFR) of ankle sprain was measured first at 24 hours after without any other stimulations. Pain Recovery Index(PRI) represents the analgesic level, and modified Pain Recovery Index(mPRI) shows the accumulated recovery level. PRI was measured at 2 hours after each stimulus on GB34, GB39 and GB42, and mPRI was during 7 days. Results : EA stimulation of GB34 and GB39 acupoint in grade 3 ankle sprain showed a marked analgesic and recovery effect. RFWN of GB42 exhibited significant analgesic and pain recovery effect. RFWN of GB34 resulted in pain recovery effect but not analgesic effects, and RFWN of GB39 resulted in analgesic effect 2 hours after but not pain recovery. However, WN did not affect the pain recovery among three acupoints at all. Conclusions : In the Grade 3 ankle sprain model, the difference of analgesic effects were explained by the acupoints and the stimulation methods according to the accumulated recovery effects during 7 days. It is insufficient to determine that a certain acupoint has a specific analgesic effect depending on the stimulation method by the results of this study. Therefore, the effects of each stimulation on the acupoints in any other meridians at the sprained ankle should be compared and analyzed.

Analgesia of Electroacupuncture and Radio-Frequency Warm Needling in Acupoint Combination on Ankle Sprain in Rats (발목염좌에 배혈에 따른 전침과 고주파온침의 진통효과)

  • Yang, Seung-Bum;Kim, Min-Su;Kim, Jae-Hyo
    • Korean Journal of Acupuncture
    • /
    • v.35 no.1
    • /
    • pp.27-35
    • /
    • 2018
  • Objectives : The purpose of this study was to investigate the analgesic effect of electroacupuncture(EA) and radio-frequency warm needling(RFWN) stimulation in acupoint combination on ankle sprained pain in rats. Methods : The lateral ligaments of the Sprague-Dawley rats ankle were injured surgically resulting in sprain, of which was divided into EA, RFWN treatment groups and control group without treatment. The level of pain was measured through foot weight bearing force ratio followed by calculating pain relief. To stimulate proximal or distal area in ankle sprain, combination of proximal acupoints(GB34-GB39) and distal acupoints(GB39-GB42) from sprain area were applied, respectively, to either EA or RFWN stimulation. In addition, naltrexone or phentolamine was injected intraperitoneally before the stimulation to observe the pathway of analgesic effects. Results : In the proximal combination of GB34-GB39, EA and RFWN significantly increased pain relief compared to the control group (p<0.05). However, in distal combination with GB39-GB42, both EA and RFWN stimulation did not relieve pain due to ankle sprains. In the combination of GB34-GB39, the analgesia of EA was inhibited by blockade of the ${\alpha}$-adrenoceptor receptor. The analgesia of RFWN was inhibited by blockade of the ${\alpha}$-adrenoceptor receptor as well as ${\mu}$-opioid receptor. Conclusions : We observed that the proximal combination was effective in relieving pain when the treatment by acupoint combination was applied to the ankle sprain pain. Also, it was confirmed that this analgesia was also related to the pathways of ${\mu}$-opioid receptors and/or ${\alpha}$-adrenoceptors.

Implantable Functional Electrical Stimulation with Inductive Power and Data Transmission System (유도전력전송방식의 이식형 기능적 전기자극)

  • Lee, Joon-Ha
    • Journal of Yeungnam Medical Science
    • /
    • v.24 no.2
    • /
    • pp.97-106
    • /
    • 2007
  • Functional electrical stimulation (FES) has developed over the last 35 years to become a scientifically, technologically and clinically recognized field of interest in clinical medicine. FES has been applied to locomotion, grasping, ventilation, incontinence, and decubitus healing. However, all of these achievements illustrate the initial applications of FES; its true potential has not yet been realized. Recently, FES systems, which are miniaturized stimulation devices, have been utilized in the clinical setting. However, because the stimulating electrodes of the current FES devices are percutaneous electrodes, which are susceptible to wire breakage, and skin infection an implantable FES stimulating electrode has been introduced in the U.S. and Japan. In the present study, an external power supply method using radio frequency (RF) coupling and data transmission was developed for the control of the implantable FES device. In addition, we review the current understanding of FES devices and their application in clinical medicine.

  • PDF

Development of Deep-Heating Stimulation System for Substituting the Heat Effect of Moxibustion (뜸의 열적효과를 구현하기 위한 심부 열 자극 시스템 개발)

  • Cha, Ji-Young;Myoung, Hyoun-Seok;Cho, Sung-Pil;Lee, Kyoung-Joung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.6
    • /
    • pp.50-57
    • /
    • 2009
  • In this paper, a deep-heating stimulation system and protocol were designed to substitute the heat effect of moxibustion. Moxibustion is used to increase immunity and cure disease. But, it is difficult to control power of heat stimulation. A designed deep-heating stimulation system using Radio-Frequency(RF) is easy to control power of heat stimulation. Also, the stimulation protocol for substitution of the heat effect of moxibustion is proposed. Core temperature was applied to infrared camera, thermometer, and infrared sensor, and then was compared with that of moxibustion. The proposed system showed that it is more effective than moxibustion in transferring heat effect in such a deep part. Also, it shows the possibility of usefulness of deep-heating stimulation system and heat stimulation protocol.

Developed an output device for high-frequency cosmetic medical equipment using micro multi-needle (마이크로 멀티니들을 이용한 고주파 피부미용 의료기기를 위한 출력 장치 개발)

  • Kim, Jun-tae;Joo, Kyu-tai;Cha, Eun Jong;Kim, Myung-mi;Jeong, Jin-hyoung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.5
    • /
    • pp.394-402
    • /
    • 2021
  • The entry of an aging society and the extension of human life expectancy, the increasing interest in women's social advancement and men's appearance, and the natural interest in K-culture through media media, while receiving worldwide attention, Focus on K-Bueaty. Recently, looking at the occupation of the medical tourism field, in the case of aesthetic medicine tourism such as molding and dermatology, it has gained popularity not only in Asia such as China and Japan, but also in North America and Europe. The first external confirmation of human aging is the wrinkles on the skin of the face. Clean, wrinkle-free, elastic and healthy skin is a desire of most people. Skin condition and condition such as focused ultrasonic stimulation (HIFU: High Intensity Focused Utrasound) and low frequency, high frequency (RF: Radio Frequency), galvanic therapy using microcurrent, cryotherapy using rapid cooling, etc. Depending on the method of management, the effect of the treatment differs depending on the output and the stimulation site, etc., even in the treatment of medical equipment and beauty equipment using the same mechanism. In this research, in order to develop invasive high-frequency dermatological devices using a large number of beauty medical devices and microneedles of beauty devices, the international standards IEC 60601-2 (standards for individual medical devices) and MFDS (Ministry of) We designed and developed a high-frequency output device in compliance with the high-frequency stimulation standard announced in the Food and Drug Safety (Ministry of Food and Drug Safety). The circuit design consists of an amplifier (AMP: Amplifier) using Class-A Topology and a power supply device using Half-Bridge Topology. As a result of measuring the developed high-frequency output device, an average efficiency of 63.86% was obtained, and the maximum output was measured at 116.7W and 50.67dBm.

Effects of a Sensory Stimulation on Weight, Stress Hormone and Behavioral State in Premature Infants (감각자극이 미숙아의 체중, 스트레스호르몬 및 행동상태에 미치는 효과)

  • 이군자
    • Journal of Korean Academy of Nursing
    • /
    • v.29 no.2
    • /
    • pp.445-455
    • /
    • 1999
  • This study has been conducted on the nonequivalent control group pretest-posttest design in quasi experimental basis and newly born premature infants from intensive care unit of G Medical University Hospital in Inchon Metropolitan were selected in two groups of 21 infants each. The first group for experimental and the other for control. Data has been collected form October 30, 1997 to August 29, 1998. For the experimental group tactile and kinesthetic stimulation was applied 2 times a day for 10 days(10 : 00~11 : 00 hours in the morning and 17 : 00~18 : 00 in the afternoon). As a weight weighing instrument. electronic indicator scale(Cas Co. korea) was used. To determine urine cortisol concentration level in stress hormone, radio immune assay method was used. And high performance liquid chlomatography was used to determine urine norepinephrine, concentration level To determine behavior status, tools developed by Anderson et at(1990) and remodeled by Kim Hee-Sook(1996) were used. Collected data were analyzed with the SAS program using x$^2$-test, student t-test, repeated measures ANOVA and paired t -test. The result were as follow. 1. As for the daily weight gain. the experimental group showed first change in weight and this group also showed higher weight in the average weight than the control group. Statistically, however, there was no significant factor between the two group. 2. The cortisol concentration in urine showed decrease in the experimental group norepinephrine concentration in urine showed increase in both experimental and control groups. No statistical significance was shown between the two groups. 3. In the aspect of behavior status. the experimental group showed statistical significance by showing inactive in the state of alert and conversion to a positive state than the control group. In conclusion, the sensory stimulation in this study showed a positive aspect through there was no statistical significance in the weight gain and urine stress hormone concentration. In the behavior status, there was statistical significance in the frequency of staying inactive in the state of alert and conversion to a positive state.

  • PDF