• Title/Summary/Keyword: Radiation technology information system

Search Result 195, Processing Time 0.033 seconds

Fusion of Gamma and Realistic Imaging (감마영상과 실사영상의 Fusion)

  • Kim, Yun-Cheol;Yu, Yeon-Uk;Seo, Young-Deok;Moon, Jong-Woon;Kim, Yeong-Seok;Won, Woo-Jae;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.78-82
    • /
    • 2010
  • Purpose: Recently, South Korea has seen a rapidly increased incidence of both breast and thyroid cancers. As a result, the I-131 scan and lymphoscintigraphy have been performed more frequently. Although this type of diagnostic imaging is prominent in that visualizes pathological conditions, which is similar to previous nuclear diagnostic imaging techniques, there is not much anatomical information obtained. Accordingly, it has been used in different ways to help find anatomical locations by transmission scan, however the results were unsatisfactory. Therefore, this study aims to realize an imaging technique which shows more anatomical information through the fusion of gamma and realistic imaging. Materials and Methods: We analyzed the data from patients who were examined by the lymphoscintigraphy and I-131 additional scan by Symbia Gamma camera (SIEMENS) in the nuclear medicine department of the National Cancer Center from April to July of 2009. First, we scanned the same location in patients by using a miniature camera (R-2000) in hyVISION. Afterwards, we scanned by gamma camera. The data we obtained was evaluated based on the scanning that measures an agreement of gamma and realistic imaging by the Gamma Ray Tool fusion program. Results: The amount of radiation technicians and patients were exposed was generated during the production process of flood source and applied transmission scan. During this time, the radiation exposure dose of technicians was an average of 14.1743 ${\mu}Sv$, while the radiation exposure dose of patients averaged 0.9037 ${\mu}Sv$. We also confirmed this to matching gamma and realistic markers in fusion imaging. Conclusion: Therefore, we found that we could provide imaging with more anatomical information to clinical doctors by fusion of system of gamma and realistic imaging. This has allowed us to perform an easier method in which to reduce the work process. In addition, we found that the radiation exposure can be reduced from the flood source. Eventually, we hope that this will be applicable in other nuclear medicine studies. Therefore, in order to respect the privacy of patients, this procedure will be performed only after the patient has agreed to the procedure after being given a detailed explanation about the process itself and its advantages.

  • PDF

Design of Dual-Polarization Antenna with High Cross-Polarization Discrimination (높은 교차편파 분리도를 가지는 이중편파 안테나 설계)

  • Lee, Sang-Ho;Oh, Taeck-Keun;Ha, Jung-Je;Lee, Yong-Shik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.3
    • /
    • pp.199-205
    • /
    • 2017
  • In a small cell base station used in densely populated areas, a dual polarized multiple antenna(MIMO) is mainly used to increase the cell capacity. This paper demonstrates a dual-polarization antenna with high cross-polarization discrimination(XPD) that can improve the capacity of a small cell using a dual polarization multiple antenna (MIMO). By using the symmetric structure and differential feeding, high XPD in all directions is achieved. In addition, a very similar radiation pattern is observed between each polarization. Because of high XPD and similar radiation pattern in all directions, proposed antenna is well adopted for small-cell multiple-input multiple-output(MIMO) system. Experimental results shows that the proposed antenna has a bandwidth of 180 MHz (2.51~2.7 GHz), a maximum gain of 4.5 dBi (3.5~4.5 dBi), and a half-power beam width of 85 degrees. In addition, average XPD of 26.4 dB in all directions, more than 13.8 dB increase than previous dual-polarization antennas which use single emitter by using different feeding or selectively use polarization through switching.

Automatic Registration Method for EO/IR Satellite Image Using Modified SIFT and Block-Processing (Modified SIFT와 블록프로세싱을 이용한 적외선과 광학 위성영상의 자동정합기법)

  • Lee, Kang-Hoon;Choi, Tae-Sun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.4 no.3
    • /
    • pp.174-181
    • /
    • 2011
  • A new registration method for IR image and EO image is proposed in this paper. IR sensor is applicable to many area because it absorbs thermal radiation energy unlike EO sensor does. However, IR sensor has difficulty to extract and match features due to low contrast compared to EO image. In order to register both images, we used modified SIFT(Scale Invariant Feature Transform) and block processing to increase feature distinctiveness. To remove outlier, we applied RANSAC(RANdom SAample Concensus) for each block. Finally, we unified matching features into single coordinate system and remove outlier again. We used 3~5um range IR image, and our experiment result showed good robustness in registration with IR image.

Low-frequency Pattern Control Using Gradient Speaker Arrays (그레디언트 스피커 배열을 이용한 저주파 지향성 제어)

  • Choi, Chan-Gyu;Park, Cheon-Il;Rho, Jungkyu;Lee, Seon-Hee
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.4
    • /
    • pp.30-36
    • /
    • 2013
  • Recently the globalization of the media content industry, various activities have been made in the field of art and the speaker system is very important in the sound industry which is one of the arts. The directional characteristics of a loudspeaker refer to the radiation of sound in certain directions and are among the most important features of a loudspeaker. Designing a loudspeaker that can keep all of its constant directivity at all frequencies is difficult due to the wavelengths of audio frequencies and the size of horns and transducers. This study proposed gradient array methods to improve low frequency pattern control of full-range speakers to maximize Direct to Reverberant Ratios at the listeners.

Development of a radiological emergency evacuation model using agent-based modeling

  • Hwang, Yujeong;Heo, Gyunyoung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2195-2206
    • /
    • 2021
  • In order to mitigate the damage caused by accidents in nuclear power plants (NPPs), evacuation strategies are usually managed on the basis of off-site effects such as the diffusion of radioactive materials and evacuee traffic simulations. However, the interactive behavior between evacuees and the accident environment has a significant effect on the consequential gap. Agent-based modeling (ABM) is a method that can control and observe such interactions by establishing agents (i.e., the evacuees) and patches (i.e., the accident environments). In this paper, a radiological emergency evacuation model is constructed to realistically check the effectiveness of an evacuation strategy using NetLogo, an ABM toolbox. Geographic layers such as radiation sources, roads, buildings, and shelters were downloaded from an official geographic information system (GIS) of Korea, and were modified into respective patches. The dispersion model adopted from the puff equation was also modified to fit the patches on the geographic layer. The evacuees were defined as vehicle agents and a traffic model was implemented by combining the shortest path search (determined by an A * algorithm) and a traffic flow model incorporated in the Nagel-Schreckenberg cellular automata model. To evaluate the radiological harm to the evacuees due to the spread of radioactive materials, a simple exposure model was established to calculate the overlap fraction between the agents and the dispersion patches. This paper aims to demonstrate that the potential of ABM can handle disaster evacuation strategies more realistically than previous approaches.

Radiological Alert Network of Extremadura (RAREx) at 2021:30 years of development and current performance of real-time monitoring

  • Ontalba, Maria Angeles;Corbacho, Jose Angel;Baeza, Antonio;Vasco, Jose;Caballero, Jose Manuel;Valencia, David;Baeza, Juan Antonio
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.770-780
    • /
    • 2022
  • In 1993 the University of Extremadura initiated the design, construction and management of the Radiological Alert Network of Extremadura (RAREx). The goal was to acquire reliable near-real-time information on the environmental radiological status in the surroundings of the Almaraz Nuclear Power Plant by measuring, mainly, the ambient dose equivalent. However, the phased development of this network has been carried out from two points of view. Firstly, there has been an increase in the number of stations comprising the network. Secondly, there has been an increase in the number of monitored parameters. As a consequence of the growth of RAREx network, large data volumes are daily generated. To face this big data paradigm, software applications have been developed and implemented in order to maintain the indispensable real-time and efficient performance of the alert network. In this paper, the description of the current status of RAREx network after 30 years of design and performance is showed. Also, the performance of the graphing software for daily assessment of the registered parameters and the automatic on real time warning notification system, which aid with the decision making process and analysis of values of possible radiological and non-radiological alterations, is briefly described in this paper.

Countermeasures for Management of Off-site Radioactive Wastes in the Event of a Major Accident at Nuclear Power Plants

  • Lee, Ji-Min;Hong, Dae Seok;Shin, Hyeong Ki;Kim, Hyun Ki
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.20 no.3
    • /
    • pp.339-347
    • /
    • 2022
  • Major accidents at nuclear power plants generate huge amounts of radioactive waste in a short period of time over a wide area outside the plant boundary. Therefore, extraordinary efforts are required for safe management of the waste. A well-established remediation plan including radioactive waste management that is prepared in advance will minimize the impact on the public and environment. In Korea, however, only limited plans exist to systematically manage this type of off-site radioactive waste generating event. In this study, we developed basic strategies for off-site radioactive waste management based on recommendations from the IAEA (International Atomic Energy Agency) and NCRP (National Council on Radiation Protection and Measurements), experiences from the Fukushima Daiichi accident in Japan, and a review of the national radioactive waste management system in Korea. These strategies included the assignment of roles and responsibilities, development of management methodologies, securement of storage capacities, preparation for the use of existing infrastructure, assurance of information transparency, and establishment of cooperative measures with international organizations.

A Study on Dose and Image Quality according to X-ray Photon Detection Method in Digital Radiography System (Digital Radiography System에서 X선 광자 검출 방식에 따른 선량 및 화질 특성에 관한 연구)

  • Hong, Sun Suk;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.247-253
    • /
    • 2013
  • The purpose is a comparative evaluation in the DR System according to the dosimetry and image quality of the quantitative and objective via Direct digital radiography, Indirect digital radiography, Image intensifier (Charge Coupled Device type) digital radiography. The experimental method used rando phantom and measured the entrance surface dose. And through using the measured entrance surface dose and then using the PCXMC program were evaluated risk due to irradiation and the effective dose. SNR and NPS and CNR were measured and analyzed by using 21cm acryl phantom. Significance of measured value was evaluated by statistics method. Entrance surface dose, major organ dose, effective dose all of them were measured the lowest rated in direct DR when it is on the basis of direct DR dose, high-dose ratio were measured in I.I DR approximately 1.3 times, indirect DR approximately 2.4 times. Risk in accordance with radiation also was measured same as dose ratio. On the conclusion that SNR measurement result based on direct DR SNR measurements, low-SNR ratio were measured in I.I DR approximately 7.25 times, indirect DR approximately 1.48 times. On the conclusion that CNR measurement result based on direct DR CNR measurements, high-dose ratio were measured in I.I type DR approximately 1.16 tims and low-dose ratio were measured in indirect DR approximately 0.87 times. Therefore Direct DR system using a-selenium sensing element to detect x-ray photon is thought effectively at the examination such as infant to sensitive irradiation and the genital gland. Because quality image is built by low dose. Also when it is necessary that image test requiring many diagnosis information, indirect DR system is thought effectively.

Establishment of Integrated Design Bases Management System of APR1400 Using BIM based Algorithm (BIM기반 Algorithm을 활용한 APR1400 설계기준 통합관리 체계 구축)

  • Shin, Jaeseop;Choi, Jaepil
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.5
    • /
    • pp.52-60
    • /
    • 2019
  • The APR1400 is a 1400MWe nuclear power plant developed through national technology development project over a period about 10years. Approximately 65,000 design drawings are produced for APR1400 construction. In order to maintain consistency among numerous drawings, the highest level of design bases drawings (DBDs) are created according to design bases and this is used in the subsequent design. However, DBDs are produced and managed on a document basis and they are managed various field, it was difficult to accurately reflect the design bases information in the subsequent design. Therefore, this study recognizes limitations of the document based DBDs and develops a system that can accurately reflect the design bases information to subsequent design by adopting BIM based design bases integrated information system. Especially, by introducing DBIL(Design Bases Information Layer) concept, DBIL was created and analyzed based on five design bases(Physical protection, Fire protection, Internal missile protection, Internal flood protection, Radiation protection) applied to APR1400. In the final result DBIL set and Datasheet are integrated of room, design bases information, building data(wall, slab, door, window, penetrations). So it can be used for subsequent design automation and design verification. Furthermore, it is expected that APR1400 DBILs data can be used extensively in constructability and design economics analysis through comparison with next generation nuclear power plant.

Noise Reduction of medical X-ray Image using Wavelet Threshold in Cone-beam CT (Cone-beam CT에서 웨이브렛 역치값을 이용한 x-ray 영상에서의 노이즈 제거)

  • Park, Jong-Duk;Huh, Young;Jin, Seung-Oh;Jeon, Sung-Chae
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.6
    • /
    • pp.42-48
    • /
    • 2007
  • In x-ray imaging system, two kinds of noises are involved. First, the charge generated from the radiation interaction with the detector during exposure. Second, the signal is then added by readout electronics noise. But, x-ray images are not modeled by Gaussian noise but as the realization of a Poisson process. In this paper, we apply a new approach to remove Poisson noise from medical X-ray image in the wavelet domain, the applied methods shows more excellent results in cone-beam CT.