• 제목/요약/키워드: Radiation technique

검색결과 1,274건 처리시간 0.032초

함정 탑재 안테나의 복사패턴 측정기법 연구 (A Study on the Radiation Pattern Measurement Technique of Shipboard Antenna)

  • 정회인
    • 한국군사과학기술학회지
    • /
    • 제4권1호
    • /
    • pp.177-187
    • /
    • 2001
  • It is important to test and evaluate the variation degree of ship-mounted antenna radiated power with respect to all directions in order to use more effectively antennas that installed on naval ships. The naval ship has various sensors for navigation, communication and electronic warfare, etc. And the performance of these sensors extremely depends on the various characteristics of antenna system to transmit and receive electromagnetic wave. The radiated power pattern of the antenna differs from all aspect angles of the ship because of complex superstructures. It is important to know the weak point(direction) of antenna radiation for appropriate operation. Therefore, the ARP(Antenna Radiation Pattern) of shipboard antennas is measured for the all aspect angles. The results of ARP measurement are utilized as reference for antenna arrangement of newly-built same class warship. This study also describes the development results for the ARP measurement technique, software design and test procedures to measure the radiation pattern of communication equipment antennas using the fixed test site.

  • PDF

전립선암에서 강도변조방사선치료 (Intensity Modulated Radiation Therapy)의 적용 (Application of Intensity Modulated Radiation Therapy (IMRT) in Prostate Cancer)

  • 박석원;오도훈;배훈식;조병철;박재홍;한승희
    • Radiation Oncology Journal
    • /
    • 제20권1호
    • /
    • pp.68-72
    • /
    • 2002
  • 최근 들어 새로운 방사선치료법인 강도변조방사선치료가 많은 종류의 종양치료에 적용되어 치료에 따른 부작용을 줄이고 치료율을 향상시키려는 노력들이 이루어지고 있다. 특히 전립선암에서 강도변조방사선치료법을 적용하여 삼차원입체조형치료에 비해 향상된 선량분포와 이로 인한 주위 정상조직의 방사선량을 줄임으로써 더욱 많은 양의 방사선을 전립선에 투여할 수 있고 이로 인하여 치료율의 상승을 기대할 수 있게 되었다. 저자들은 강도변조방사선치료를 전립선암에 적용하였기에 이에 대한 문헌고찰과 함께 치료과정을 보고하고자 한다.

Trends in intensity-modulated radiation therapy use for rectal cancer in the neoadjuvant setting: a National Cancer Database analysis

  • Wegner, Rodney E.;Abel, Stephen;White, Richard J.;Horne, Zachary D.;Hasan, Shaakir;Kirichenko, Alexander V.
    • Radiation Oncology Journal
    • /
    • 제36권4호
    • /
    • pp.276-284
    • /
    • 2018
  • Purpose: Traditionally, three-dimensional conformal radiation therapy (3D-CRT) is used for neoadjuvant chemoradiation in locally advanced rectal cancer. Intensity-modulated radiation therapy (IMRT) was later developed for more conformal dose distribution, with the potential for reduced toxicity across many disease sites. We sought to use the National Cancer Database (NCDB) to examine trends and predictors for IMRT use in rectal cancer. Materials and Methods: We queried the NCDB from 2004 to 2015 for patients with rectal adenocarcinoma treated with neoadjuvant concurrent chemoradiation to standard doses followed by surgical resection. Odds ratios were used to determine predictors of IMRT use. Univariable and multivariable Cox regressions were used to determine potential predictors of overall survival (OS). Propensity matching was used to account for any indication bias. Results: Among 21,490 eligible patients, 3,131 were treated with IMRT. IMRT use increased from 1% in 2004 to 22% in 2014. Predictors for IMRT use included increased N stage, higher comorbidity score, more recent year, treatment at an academic facility, increased income, and higher educational level. On propensity-adjusted, multivariable analysis, male gender, increased distance to facility, higher comorbidity score, IMRT technique, government insurance, African-American race, and non-metro location were predictive of worse OS. Of note, the complete response rate at time of surgery was 28% with non-IMRT and 21% with IMRT. Conclusion: IMRT use has steadily increased in the treatment of rectal cancer, but still remains only a fraction of overall treatment technique, more often reserved for higher disease burden.

두경부암의 양성자치료: 현재의 임상 적용 및 발전 방향 (Proton Therapy for Head and Neck Cancer: Current Clinical Applications and Future Direction)

  • 오동렬
    • 대한두경부종양학회지
    • /
    • 제37권1호
    • /
    • pp.1-10
    • /
    • 2021
  • Intensity-modulated radiation therapy (IMRT) using X-rays is a standard technique implemented for treating head and neck cancer (HN C). Compared to 3D conformal RT, IMRT can significantly reduce the radiation dose to surrounding normal tissues by using a highly conformal dose to the tumor. Proton therapy is a type of RT that uses positively charged particles named protons. Proton therapy has a unique energy deposit (i.e., Bragg peak) and greater biological effectiveness than that of therapy using X-rays. These inherent properties of proton therapy make the technique advantageous for HNC treatment. Recently, advanced techniques such as intensity-modulated proton therapy have further decreased the dose to normal organs with a higher conformal dose to the tumor. The usage of proton therapy for HNC is becoming widespread as the number of operational proton therapy centers has increased worldwide. This paper aims to present the current clinical evidence of proton therapy utility to HNC clinicians through a literature review. It also discusses the challenges associated with proton therapy and prospective development of the technique.

Dosimetric Effects of Intrafractional Organ Motion in Field-in-Field Technique for Whole-Breast Irradiation

  • Hong, Chae-Seon;Ju, Sang Gyu;Choi, Doo Ho;Han, Youngyih;Huh, Seung Jae;Park, Won;Ahn, Yong Chan;Kim, Jin Sung;Lim, Do Hoon
    • 한국의학물리학회지:의학물리
    • /
    • 제30권3호
    • /
    • pp.65-73
    • /
    • 2019
  • Purpose: We evaluated the motion-induced dosimetric effects on the field-in-field (FIF) technique for whole-breast irradiation (WBI) using actual patient organ motion data obtained from cine electronic portal imaging device (cine EPID) images during treatment. Materials and Methods: Ten breast cancer patients who received WBI after breast-conserving surgery were selected. The static FIF (SFIF) plan involved the application of two parallel opposing tangential and boost FIFs. To obtain the amplitude of the internal organ motion during treatment, cine EPID images were acquired five times for each patient. The outside contour of the breast (OCB) and chest wall (CW) contour were tracked using in-house motion analysis software. Intrafractional organ motion was analyzed. The dynamic FIF (DFIF) reflecting intrafractional organ motion incorporated into the SFIF plan was calculated and compared with the SFIF in terms of the dose homogeneity index (DHI90/10) for the target and V20 for the ipsilateral lung. Results: The average motion amplitudes along the X and Y directions were 1.84±1.09 mm and 0.69±0.50 mm for OCB and 1.88±1.07 mm and 1.66±1.49 mm for CW, respectively. The maximum motion amplitudes along the X and Y directions were 5.53 and 2.08 mm for OCB and 5.22 and 6.79 mm for CW, respectively. Significant differences in DHI90/10 values were observed between SFIF and DFIF (0.94 vs 0.95, P<0.05) in statistical analysis. The average V20 for the lung in the DFIF was slightly higher than that of the SFIF in statistical analysis (19.21 vs 19.00, P<0.05). Conclusion: Our findings indicate that the FIF technique can form a safe and effective treatment method for WBI. Regular monitoring using cine EPID images can be effective in reducing motion-induced dosimetric errors.

방사선치료를 받는 말기암환자들을 대상으로 한 이완요법 (Bedside Teaching of Relaxation Technique for Terminal Cancer Patients Treated with Radiation Therapy)

  • 김상원;전미선;김효신
    • Journal of Hospice and Palliative Care
    • /
    • 제19권3호
    • /
    • pp.256-261
    • /
    • 2016
  • 방사선치료는 암과 관련된 증상을 완화시키는 목적으로 자주 사용되고 있다. 정확하고 안전한 방사선치료를 받기 위해서는 방사선이 나오는 동안 치료 테이블 위에 가만히 누워 있어야 한다. 그러나 일부 환자는 기질적인 문제 외에 심리적인 문제에서 기인한 증상으로 인해 가만히 누워 있지 못한다. 이 논문에서는 모의치료 단계 전부터 치료 테이블에 바로 누워 있지 못했지만 별 다른 장소에서의 교육 참여 없이 침상에서 쉽게 할 수 있는 이완요법을 배워 방사선치료 하는 동안 가만히 누워 있는 게 가능했던 두 명의 말기암환자 사례를 보고하고자 한다.

후방 복사된 초음파를 이용한 표면 지역의 평가 기술 (The Evaluation Technique of Surface Region using Backward-Radiated Ultrasound)

  • 권성덕
    • 비파괴검사학회지
    • /
    • 제16권4호
    • /
    • pp.241-250
    • /
    • 1997
  • 액체/고체 경계면에서 후방 복사된 초음파의 주파수 분석에 의해 Si layer/mesh Au/Si substrate 시편에 존재하는 표면 탄성파의 주파수 의존성이 측정되었다. 사용된 광역 탐촉자(2, 5, 10MHz)의 주파수에 따라 다르게 나타난 후방 복사의 입사각 의존성은 이 현상이 표면 지역에 발생된 표면파로부터의 에너지 복사에 의한 것임을 보여주었다. 후방 산란된 초음파의 입사각 의존성을 연속적으로 측정하기 위한 초음파 각도계가 제작되었고 다른 비율의 구리 분말이 섞인 에폭시에 의해 접착된 Ni layer/Al substrate 시편에 대해 후방복사 세기의 입사각 의존성이 측정되었다. (5MHz) 후방 복사의 폭과 패턴은 표면파 속도의 주파수 의존성, layer 접합의 질 그리고 표면 지역의 구조 등 여러 정보를 가지고 있음이 밝혀졌다.

  • PDF

Multistatic Field또는 3차원 공용보상체를 사용한 유방의 방사선 조사법의 평가 (Improved Breast Irradiation Techniques Using Multistatic Fields or Three Dimensional Universal Compensators)

  • 한영이;조재호;박희철;추성실;서창옥
    • Radiation Oncology Journal
    • /
    • 제20권1호
    • /
    • pp.24-33
    • /
    • 2002
  • 목적 : 유방보존 수술 후 행하는 방사선치료인 2문 대칭조사(two tangential field technique)시 나타나는 선량분포의 불균일성을 효과적으로 개선하기 위하여, multistatic fields의 사용법과 공용보상체 사용법을 제시하고 평가하였다. 대상 및 방법 : 1) Multistatic field 방법 3차원의 치료계획용 software (RTP)를 이용하여, wedge를 사용한 2문 대칭 조사의 최적의 치료계획을 시행한 후 beam's eye view상에서 과조사가 일어나는 부분을 가리워 주도록 blocked field를 설계하고, 그 beam에 대칭되는 beam을 만들었다. 기존의 2개의 tangential field와 추가된 field의 weighting을 최적의 선량분포를 갖도록 조절하였다. 2) 공용보상체 사용법 : 1999와 2000년에 본원에서 whole-breast radiotherapy를 받은 환자 20명의 유방의 크기를 측정하고 평균하여 표준 유방 모델을 만들었다. 이 모델에 대하여 공용보상체를 설계하고, 설계된 공용보상체의 geometry를 RTP에 입력한 후 환자의 치료 계획을 수행하였다. 2문 대칭조사 치료 계획과, multistatic fields의 경우 그리고 공용 보상체를 사용한 경우의 치료계획에서의 불균일도(DII : 처방선량의 $95-105\%$를 벗어나는 PTV의 부피의 백분율), 최대선량 값$(D_{max})$ 그리고 등가선량 곡선을 각각 비교하였다. 결과 : Multistatic field 방법은 DII의 평균값을 $14.6\%$ (p value<0.000) 낮추고 $D_{max}$$4.7\%$ (p value<0.000) 낮춤으로써, 전통적인 2문 대칭 조사법보다 우수한 방법으로 확인되었다. 반면에 공용보상체의 사용은 평균 DII를 $3.7\%$ 낮추지만(p value=0.260) 평균 $D_{max}$는 거의동일 하여($0.3\%$ 감소, p value=0.867), 전통적인 방법보다 우수성이 크게는 없는 것으로 평가되었다. 그러나 환자의 체곡선이 보상체와 잘 일치하는 경우에는 DII가 $18\%$까지 감소하였다. 결론 : Multistatic field 방법은 모든 환자에 대하여 선량분포의 균일성을 전반적으로 향상시키는 효과적인 방법으로 평가되는 반면 공용보상체의 사용은 보상체의 크기가 환자의 체 윤곽과 잘 일치하는 경우만 효과적으로, 적용의 범위에는 한계가 있는 방법으로 평가되었다.

뇌암 및 두경부암 체적변조방사선치료시 Jaw-Tracking 기법의 선량학적 유용성 평가 (Evaluation of the Jaw-Tracking Technique for Volume-Modulated Radiation Therapy in Brain Cancer and Head and Neck Cancer)

  • 김희성;문재희;김군주;서정민;이정진;최재훈;김성기;장인기
    • 대한방사선치료학회지
    • /
    • 제30권1_2호
    • /
    • pp.177-183
    • /
    • 2018
  • 목 적 : 체적변조회전방사선치료(VMAT)는 종양의 모양에 맞게 균일하면서도 정밀한 방사선 조사를 하면서 동시에 정상조직의 방사선 손상위험을 줄이는 장점이 있어 뇌암, 두경부암 및 전립선암 등의 종양과 정상장기가 가까운 암의 치료에 사용되고 있다. 본 연구의 목적은 뇌암 및 두경부암 환자의 VMAT 방사선 치료 시 Jaw-Tracking technique(JTT)의 선량학적 유용성을 평가하고자 한다. 대상 및 방법 : 본원에서 VMAT 치료기법으로 방사선치료를 받은 뇌암 및 두경부암 환자 8명을 선택하였다. 환자의 종양 및 정상 장기의 윤곽그리기(contouring) 정보를 Velocity(Varian, USA)의 deformable registration을 이용하여 Rando phantom에 fusion하였다. Varian Eclipse(ver 15.5, Varian, USA)를 사용하여 Jaw-Tracking 사용 유무를 제외하고 환자 치료 시 사용한 beam parameter와 동일하게 치료계획을 진행하였다. 평가 지표로써 target과 OAR의 최대선량, 평균선량을 사용하여 비교하였고 치료계획 검증을 위해 Portal dosimetry를 시행하였다. 결 과 : JTT를 사용했을 경우는 Static-Jaw technique(SJT)을 사용하였을 경우보다 OAR의 상대 선량이 각각 평균선량은 5.24 %, 최대선량은 7.05 % 감소한 것으로 나타났다. 다양한 OAR에서 평균선량과 최대선량의 감소의 범위는 각각 0.01~3.16 Gy, 0.12~6.27 Gy로 나타났다. Target의 경우는 JTT의 경우가 SJT보다 GTV, CTV, PTV의 최대선량이 각각 0.17 %, 0.43 %, 0.37 % 감소하였으며, 평균선량은 0.24 %, 0.47 %, 0.47% 감소하였다. 감마분석은 3 %/3 mm, 통과율 95 % 이상을 통과 기준으로 설정하였고 JTT, SJT 통과율은 각각 $98{\pm}1.73%$, $97{\pm}1.83%$이었다. 실험에 적용된 모든 OAR의 선량을 비교해 보았을 때, JTT을 사용하였을 경우가 SJT보다 MLC 외에 추가적인 jaw 차폐로 인하여 선량이 유의미하게 줄어들었다는 것을 알 수 있었다. 결 론 : VMAT 치료계획을 이용한 방사선 치료시 뇌암, 두경부암과 같이 종양과 정상 장기가 인접한 경우와 MLC를 통한 누설선량을 증가시킬 수 있는 넓은 조사야 및 높은 에너지의 사용을 필요로 하는 방사선 치료 시 JTT를 적용함으로써 종양주변 정상조직의 피폭선량을 낮추고 이로 인해 PTV의 target coverage를 높일 수 있을 것이라 판단된다.

  • PDF

유리선량계를 이용한 관전류자동조절기법과 고정관전류기법에서 저선량 및 고해상 흉부CT의 노이즈 및 선량 비교 (Comparison of Noise and Doses of Low Dose and High Resolution Chest CT for Automatic Tube Current Modulation and Fixed Tube Current Technique using Glass Dosimetry)

  • 박태석;한준희;조승연;이은임;조규원;권대철
    • 방사선산업학회지
    • /
    • 제11권3호
    • /
    • pp.131-137
    • /
    • 2017
  • To compare the radiation dose and image noise of low dose computed tomography (CT) and high resolution CT using the fixed tube current technique and automatic tube current modulation (CARE Dose 4D). Chest CT and human anthropomorphic phantom were used the RPL (radiophotoluminescence) dosimeters. For image evaluation, standard deviation of mean CT attenuation coefficient and CT attenuation coefficient was measured using ROI analysis function. The effective dose was calculated using CTDIvol and DLP. CARE Dose 4D was reduced by 74.7% and HRCT by 64.4% compared to the fixed tube current technique in low dose CT of chest phantom. In CTDIvol and DLP, the dose of CARE Dose 4D was reduced by fixed tube current technique. For effective dose, CARE Dose 4D was reduced by 47% and HRCT by 46.9% compared to the fixed tube current method, and the dose of CARE Dose 4D was significantly different (p<.05). Noise in the image was higher than that in the fixed tube current technique. Noise difference in the image of CARE Dose 4D in low dose CT was significant (p<.05). The low radiation dose and the noise difference of the CARE Dose 4D were compared with the fixed tube current technique in low dose CT and HRCT using chest phantom. The radiation doses using CARE Dose 4D were in accordance with the national and international dose standards. CARE Dose 4D should be applied to low dose CT and HRCT for clinical examination.