• 제목/요약/키워드: Radiation quality

검색결과 1,609건 처리시간 0.028초

Effect of Light Receiving rate on Growth and Quality of Ginseng Cultivated in Plastic House

  • Sang Young Seo;Jong hyeon Cho;Chang Su Kim;Hyo Jin Kim;Min Sil An;Du Hyeon Yoon
    • 한국자원식물학회:학술대회논문집
    • /
    • 한국자원식물학회 2020년도 추계국제학술대회
    • /
    • pp.62-62
    • /
    • 2020
  • Ginseng is a shade-plant cultivated using shading facilities. However, at too low light levels, root growth is poor, and at high light levels, the destruction of chlorophyll reduces the photosynthesis efficiency due to leaf burn and early fall leaves. The ginseng has a lightsaturation point of 12,000~15,000 lux when grown at 15 to 20℃ and 9,500 lux at 25℃. This study was conducted to select the optimal light intensity of 3-year-old ginseng grown in blue-white film plastic house. The seeds were planted in the blue-white film plastic house with different light receiving rate (March 17, 2020). Between April and September, the average air temperature in the house was 20.4-20.7℃. Average soil temperature was 18.3℃-18.5℃. The chemical properties of the test soil was as follows. The pH level was 7.0-7.4, EC was 0.5-0.6 dS/m, OM was at the levels of 33.6-37.7 g/kg, P2O5 was 513.0-590.8 mg/kg, slightly higher than the allowable 400 mg/kg. The amount of light intensity, illuminance, and solar radiation in the blue-white film house was increased as the light-receiving rate increased and the amount of light intensity was found to be 9-14% compared to the open field, 8-13% illuminance and 9-14% solar irradiation respectively. The photosynthesis rate was the lowest at 3.1 µmolCO2/m2/s in the 9% light blue-white plastic house and 4.2 and 4.0 µmolCO2/m2/s in the 12% and 14% light blue-white plastic house, respectively. These results generally indicate that the photosynthesis of plants increases with the amount of light, but the ginseng has a lower light saturation point at high temperatures, and the higher the amount of light, the lower the photosynthetic efficiency. The SPAD (chlorophyll content) value decreased as the increase of light-receiving rate, and was the highest at 32.7 in 9% light blue-white plastic house. Ginseng germination started on April 11 and took 13-15 days to germinate. The overall germination rate was 82.9-85.8%. The plant height and length of stem were long in the 9% light-receiving plastic house. The diameter of stem was thick in the 12-14% light-receiving plastic house. In the 12% and 14% light-receiving plastic house, the length and diameter of taproot was long and thick, so the fresh weight of root per plant was 20 g or more, which was heavier than 16.9 g of the 9% light-receiving plastic house. The disease incidence (Alternaria blight, Gray mold and Damping-off etc.) rate were 0.9-2.7%. The incidence of Sclerotinia rot disease was 7.5-8.4%, and root rot was 0-20.0%. The incidence ratio of rusty root ginseng was 34.4-38.7% level, which was an increase from the previous year's 15% level.

  • PDF

자궁경부암용 팬톰을 이용한 HDR (High dose rate) 근접치료의 선량 평가 (Dose Verification Using Pelvic Phantom in High Dose Rate (HDR) Brachytherapy)

  • 장지나;허순녕;김회남;윤세철;최보영;이형구;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제14권1호
    • /
    • pp.15-19
    • /
    • 2003
  • HDR (High dose rate) 근접 치료는 기존의 LDR (Low dose rate) 근접 치료에서 야기되었던 치료 시간이나 선량 최적화 등의 문제점을 해결하였기 때문에 자궁경부암 치료에 많이 사용되고 있다. 그러나, 단시간에 고선량이 조사되는 HDR 근접치료에서 치료 효과를 극대화시키기 위해서는 선량 계산 알고리즘, 위치 계산 알고리즘, 최적화 알고리즘이 정확하게 검증되어야 한다. 이를 위해서는 인체 등가 팬톰과 치료 계획 컴퓨터의 선량 분포 곡선을 비교함으로써 검증할 수 있다. 본 연구에서는 이러한 검증이 가능하도록 자궁경부암용 팬톰을 설계, 제작하여 HDR 치료 계획 컴퓨터와 팬톰과의 선량을 비교, 평가하는 것이다 이 자궁경부암용 팬톰은 높은 해상도를 가진 선량 측정기를 사용하여 정량적인 평가가 가능하도록 제작되었고, 인체 등가물질인 물과 아크릴을 사용하여 제작하였다 또한, 팬톰 내의 방사선량 측정을 위해서 $\frac{1}{8}$ 인치 TLD (Thermoluminescent dosimeters) 칩과 공간 해상도가 1 mm 이내인 필름을 사용하였다. 이 자궁경부암용 팬톰는 HDR applicator의 고정을 위해 applicator 홀더의 홈 안에 HDR applicator가 삽입되게 제작하였고 세 개의 TLD 홀더에는 TLD 칩(TLD 간의 거리는 5 mm)이 정렬되게 제작하여 A점이나 B점 같은 특정 점의 절대 선량을 측정할 수 있게 제작하였다 필름은 3개의 직교(orthogonal) 평면에 삽입되도록 제작하여 상대 선량 측정이 가능하게 하였다. 사용된 치료 계획 시스템은 Nucletron Plato system이고, Microselectron Ir-192 소스를 사용하였다. 선량 평가 결과, TLD 선량의 경우 A, B point를 포함하여 직장과 방광 선량이 $\pm$4% 이내로 치료계획 컴퓨터(Plato, Nucletron)와 일치하였고, 필름의 경우 선량 분포 곡선이 치료계획 컴퓨터의 선량 분포 곡선 패턴과 거의 일치하는 우수한 결과를 보였다. 제작된 자궁경부암용 팬톰은 HDR 치료 계획 컴퓨터의 선량 계산 알고리즘의 평가 및 검증에 유용하게 사용될 것이고, 이 팬톰은 강남성모병원 치료방사선과 HDR 근접치료 기기의 선량과 위치확인의 QA(quality assurance) 도구로써 사용하려고 추진 중에 있다.

  • PDF

Ecosysteme de I′Etang de Berre (Mediterranee nord-occidentale) : Caracteres Generales Physiques, Chimiques et Biologiques

  • Kim, Ki-Tai
    • 환경생물
    • /
    • 제22권2호
    • /
    • pp.247-258
    • /
    • 2004
  • Climatological, hydrological and planktonical research studies, measurements of primary production and photosynthetic efficiency from December 1976 to December 1978 have been carried out in two brackish lakes: Lake Etang de Berre and Lake Etang de Vaine located in the French Mediterranean coast, in the region of Carry-le-Rouet located on the north-west Mediterranean near Marseilles, and in fresh water inflows from 4 Rivers (Touloubre, Durance, Arc, Durancole) to Lake Etang de Berre. Physico-chemical parameters were measured for this study: water temperature, salinity, density, pH, alcalinity, dissolved oxygen (% saturation), phosphate, nitrate, nitrite, silicate etc. Diverse biological parameters were also studied: photosynthetic pigments, phaeopigments, specific composition and biomass of phytoplankton, primary pelagic production etc. Climatical factors were studied: air-temperature, solar-radiation, evaporation, direction (including strength) of winds, precipitation and freshwater volume of the four rivers. The changes in Lake ‘Etang de Berre’ ecosystem depend on the quality of the water in the Durance River, and on the effects of seawater near the entrance of the Caronte Canal. The water quality of the lake varies horizontally and vertically as a result of atmospheric phenomena, maritime currents and tides. The distribution of water temperatures is generally heterogeneous. Southeasterly winds and the Northeasterly Mistral wind are important in the origins of circulated and mixed water masses. These winds are both frequent and strong. They have, as a result, a great effect on the water environment of Lake Etang de Berre. In theory, the annual precipitation in this region is well over eight times the water mass of the lake. The water of the Durance River flows into Lake Etang de Berre through the EDF Canal, amounting to 90% of the precipitation. However, reduction of rainfall in dry seasons has a serious effect on the hydrological characteristics of the lake. The temperature in the winter is partially caused by the low temperature of fresh water, particularly that of the Durance River. The hydrological season of fresh and brackish water is about one month ahead of the hydrological season of sea water in its vicinity. The salinity of Lake Etang de Berre runs approximately 3$\textperthousand$, except at lower levels and near the entrance to the Caronte Canal. However, when the volume of the Durance River water is reduced in the summer and fall, the salinity rises to 15$\textperthousand$. In the lake, the ratio of fresh water to sea water is six to one (6:1). The large quantities of seston conveyed by rivers, particularly the Durance diversion, strongly reduce the transparency in the brackish waters. Although the amount of sunshine is also notable, transparency is slight because of the large amount of seston, carried chiefly by Tripton in the fresh water of the Durance River. Therefore, photosynthesis generally occurs only in the surface layer. The transparency progressively increases from freshwater to open seawater, as mineral particles sink to the bottom (about 1.7kg $m^{-2}a^{-1}$ on the average in brackish lakes). The concentration of dissolved oxygen and the rate of oxygen saturation in seawater (Carry-le-Rouet) ranged from 5.0 to 6.0 $m\ell$ㆍ.$1^{-1}$, and from 95 to 105%, respectively. The amount of dissolved oxygen in Etang de Berre oscillated between 2.9 and 268.3%. The monographs of phosphate, nitrate, nitrite and silicate were published as a part of a study on the ecology of phytoplankton in these environments. Horizontal and vertical distributions of these nutriments were studied in detail. The recent diversion of the Durance River into Lake Etang de Berre has effected a fundamental change in this formerly marine environment, which has had a great impact in its plankton populations. A total of 182 taxa were identified, including 111 Bacillariophyceae, 44 Chlorophyceae, and 15 Cyanophyceae. The most abundant species are small freshwater algae, mainly Chlorophyceae. The average density is about $10^{8}$ cells $1^{-1}$ in Lake Etang de Berre, and about double that amount in Lake Etang de Vaine. Differences in phytoplankton abundance and composition at the various stations or at various depths are slight. Cell biovolume V (equivalent to true biomass), plasma volume VP (‘useful’ biomass) and, simultaneously. the cell surface area S and S/V ratio through the measurement of cell dimensions were computed as the parameters of phytoplankton productivity and metabolism. Pigment concentrations are generally very high on account of phytoplankton blooms by Cyanophyceae, Chlorophyceae and Cryptophyceae. On the other hand, in freshwaters and marine waters, pigment concentrations are comparatively low and stable, showing slight annual variation. The variations of ATP concentration were closely related to those of chlorophyll a and phytoplankton blooms only in marine waters. The carbon uptake rates ranged between 38 and 1091 mg$Cm^{-2}d^{-1}$, with an average surface value of 256 mg; water-column carbon-uptake rates ranged between 240 and 2310 mg$Cm^{-2}d^{-1}$, with an average of 810, representing 290 mg$Cm^{-2}$, per year 45 000 tons per year of photosynthetized carbon for the whole lake. Gross photosynthetic production measured by the method of Ryther was studied over a 2-year period. The values obtained from marine water(Carry-le-Rouet) ranged from 23 to 2 337 mg$Cm^{-2}d^{-1}$, with a weighted average of 319, representing about 110 gCm$^{-2}$ per year. The values in brakish water (Etang de Berre) ranged from 14 to 1778 mg$Cm^{-2}d^{-1}$, with a weighted average of 682, representing 250 mg$Cm^{-2}$ per year and 38 400 tons per year of photosynthesized carbon for the whole lake.

벼에서 밀 고분자 글루테닌 단백질(TaGlu-Ax1) 발현을 통하여 쌀가루 가공적성 증진을 위한 마커프리(marker-free) 형질전환 벼의 개발 (Development of Marker-free TaGlu-Ax1 Transgenic Rice Harboring a Wheat High-molecular-weight Glutenin Subunit (HMW-GS) Protein)

  • 정남희;전승호;김둘이;이춘석;옥현충;박기도;홍하철;이승식;문중경;박수권
    • 생명과학회지
    • /
    • 제26권10호
    • /
    • pp.1121-1129
    • /
    • 2016
  • 밀의 고분자 글루테닌 서브유닛[high molecular-weight glutenin subunit (HMW-GS)]은 밀가루의 성질을 결정하는데 가장 중요한 요소이며 가공적성을 나타내는데 중요한 역할을 수행한다. 우리는 Agrobacterium 동시 형질전환법을 이용하여 한국 밀 품종인 ‘조경’으로부터 밀 HMW-GS을 암호화하는 TaGlu-Ax1 유전자를 가지는 marker-free 형질전환 벼를 생산하였다. TaGlu-Ax1 유전자의 종자 특이적 발현을 위하여 밀에서 존재하는 TaGlu-Bx7 유전자의 자체 프로모터를 벡터 내에 삽입하였다. 동시 접종을 위해서 오직 TaGlu-Ax1 유전자와 hygromycin phosphotransferase II (HPTII) 저항성 유전자만으로 구성된 두 종류의 발현 카세트를 독립적으로 Agrobacterium EHA105에 도입하였고, TaGlu-Ax1와 HPTII가 도입된 각각의 EHA105 Agrobacterium을 3:1 비율로 혼합하여 벼 캘러스에 접종하였다. 210개의 HPTII 저항성 형질전환체 중에서 벼 게놈에 TaGlu-Ax1과 HPTII가 모두 삽입된 20개의 형질전환 라인을 획득하였다. TaGlu-Ax1와 HPTII가 벼 게놈에 도입된 것을 Southern blot을 통해서 다시 확인하였다. 형질전환 벼 T1 세대의 종자에서 밀 TaGlu-Ax1 유전자가 전사와 번역되어 오직 TaGlu-Ax1만을 가지는 marker-free 식물체를 T1세대에서 성공적으로 선발할 수 있었다. TaGlu-Ax1 유전자가 발현되는 marker-free 형질전환 식물체는 야생형(wild type)과의 표현형 차이는 없었다. 형질전환 벼의 쌀가루의 제빵적성을 비교하였을 때 TaGlu-Ax1 유전자만이 발현되어서는 제빵적성이 더 나아지지 않았다. 그러므로 더 많은 밀 고분자 및 저분자 글루테닌, 글리아딘의 유전자의 집적과 조합이 쌀가루 가공적성을 증진시키는데 필요하다. 결론적으로 TaGlu-Ax1 marker-free 형질전환 벼는 쌀가루 가공적성을 증진시키는데 좋은 재료로 사용될 것이다.

파프리카 여름재배시 차광방법이 생육과 과실특성에 미치는 영향 (Effect of Shading Methods on Growth and Fruit Quality of Paprika in Summer Season)

  • 하준봉;임채신;강효용;강양수;황승재;문형수;안철근
    • 생물환경조절학회지
    • /
    • 제21권4호
    • /
    • pp.419-427
    • /
    • 2012
  • 파프리카('Cupra', 'Coletti') 여름작기 재배시 고온기 극복을 위해 내부 차광 스크린(외부광이 $700W{\cdot}m^{-2}$ 이상일 때 차광스크린 작동하여 10~20% 차광률 유지)과 차광제 처리(차광제와 물을 1 : 4의 비율로 희석하여 온실 외부 지붕을 살포 30% 정도의 차광률 유지)의 효과를 분석하고자 연구를 수행하였다. PPFD는 차광제 처리구가 무처리구에 비해 30%, 내부 스크린 처리구에 비해 20% 감소시키는 효과를 보였다. 차광제 처리구에서 무처리구와 내부 스크린 처리구에 비해 PPFD의 감소시키는 효과를 보여 차광제의 차광효과가 더 높았고, 차광제 처리에 의해 온실 내 온도 감소효과가 더 높게 나타났다. 습도 부족분 변화는 무처리구와 내부 스크린 처리구의 경우 오전 9시에 최대 허용범위인 $8g{\cdot}m^{-3}$을 벗어나 각각 오후 2시에 최고 $16.6g{\cdot}m^{-3}$$13.8g{\cdot}m^{-3}$까지 도달 했지만, 차광제 처리구에서는 무처리구와 내부 스크린 처리구보다 2시간 뒤인 11시에 $8.6g{\cdot}m^{-3}$으로 허용 범위를 벗어났고, 오후 4시에 최고 $12.1g{\cdot}m^{-3}$까지 상승하여 생육환경 조건이 더 양호해졌다. 차광제 처리구와 내부 스크린 처리구에서 무처리구에 비해 엽온이 $2^{\circ}C$, 과실의 온도가 $5^{\circ}C$, 그리고 꽃의 온도가 $3^{\circ}C$ 정도 낮아지는 효과를 보였다. 차광제 처리구와 내부 스크린 처리구에서 무처리구에 비해 초장이 두 품종 모두에서 유의적으로 길어졌고, 분지수, 경경, 잎크기는 유의성이 인정되지 않았다. 잿빛곰팡이의 발생률은 무처리구에 비해 차광제 처리구에서 품종에 따라 14.7~22.1% 감소하는 효과가 있었다. 과실크기는 차광처리에 의해 두 품종 모두에서 무처리구에 비해 증가하였으나, 심실수, 과피 두께는 유의한 차이를 보이지 않았다. 과육의 무게는 차광제 처리구와 내부 스크린 처리구에서 10~15g 증가하였지만, 당도는 감소하는 경향을 보였다. 차광에 따른 색도는 차이가 없었고, 경도는 차광 시 약간 증가하는 경향을 보였다. 수량은 무처리구에 비해 차광제 처리구와 내부 스크린 처리구에서 상품율이 11.7~22.6% 증가하였고, 상품과수는 4.0~12.2개로 증가했다. 따라서 무처리구에 비해 차광제 처리구에서 여름철 고온기의 극복에 효과가 있는 것으로 나타났다.

동적 심근관류 SPECT에서 심장의 위치 측정방법에 대한 고찰 (An Optimization Method of Measuring Heart Position in Dynamic Myocardial Perfusion SPECT with a CZT-based camera)

  • 성지혜;이동훈;김은혜;정우영
    • 핵의학기술
    • /
    • 제23권1호
    • /
    • pp.75-79
    • /
    • 2019
  • 관상동맥 혈류예비능(CFR)은 관상동맥 협착에 대한 기능적 평가를 하는데 중요한 지표로 사용되고, 허혈성 심장질환(IHD)의 발생을 조기에 진단할 수 있다. 최근 도입된 Discovery NM 530c (D530c) 장비의 구조적 특성으로 인해 동적인 영상 획득이 가능해졌고, 심근 혈류 및 관상동맥 혈류예비능의 측정을 할 수 있게 되었다. D530c 19개 CZT 검출기의 FOV가 교차되는 영역을 QFOV라고 하며, 영상의 질을 위해 QFOV 중앙으로부터 2 cm 이내 심장을 위치시키고 촬영할 것을 권고하고 있다. 동적 심근관류 SPECT 시에 심장의 위치를 선정하기 위한 최적화된 방법을 연구하였다. 심장의 위치를 측정하기 위한 도구로 이동형 초음파를 이용하였다. 환자는 parasternal long-axis view (PLAX) 스캔하였고, 심장 내 구조물이 잘 보이는 탐촉자 지점에 위치를 표시하였다. 환자의 신체에 표시한 지점과 D530c 검출기에 표시된 기준점을 서로 일치시킨 상태에서 약물부하(stress)를 하였고, 방사성동위원소를 순간주사(bolus injection) 하면서 동적 촬영을 시행하였다. 3시간 경과 후, 휴지기(rest) 촬영 시 QFOV 중앙에 심장이 위치하도록 조정하였다. 테이블 및 검출기 위치에 대하여 이동형 초음파를 이용한 dynamic stress와 QFOV 중앙에 위치시킨 rest의 좌표를 비교 분석한 결과, 모든 항목에서 통계적으로 유의한 차이가 없었다(P > 0.05). 이동형 초음파의 이용은 비교적 사용이 간편하면서 시간 단축과 함께 공간의 제약이 없었고, 심장의 정확한 위치 선정에 도움이 되었다. 이는 영상의 질향상과 환자의 불필요한 방사선 피폭을 최소화하고, 심근혈류 및 관상동맥 혈류예비능의 정량적 평가에 도움을 줌으로써 임상적 진단에 효과적일 것으로 사료된다.

인터벤션 하지 혈관조영검사를 위한 보조기구의 유용성 평가 (Utility Evaluation of Supportive Devices for Interventional Lower Extremity Angiography)

  • 공창기;송종남;정문택;한재복
    • 한국방사선학회논문지
    • /
    • 제13권4호
    • /
    • pp.613-621
    • /
    • 2019
  • 하지 혈관조영검사에서 움직임을 줄이기 위한 방법으로 재질별 하드보드지, 포맥스, 폴리카보네이트, 아크릴을 사용하여 고정용 보조기구를 제작하였고, 제작된 재질별 Phantom의 정량적 화질평가를 위해 마스크 영상, DSA 영상, Roadmap 영상을 SNR과 CNR로 분석하여 보조기구의 유용성을 알아보고자 하였다. DSA 기법으로 하지 Phantom 만을 사용하여 촬영한 마스크 영상과 보조기구 위에 하지 Phantom을 올려놓고 촬영한 마스크 영상의 SNR과 CNR을 비교한 결과 SNR은 약 0~0.06(0~10%), CNR은 약 0~0.003(0~5.36%)정도의 낮은 차이를 확인 하였다. DSA 기법으로 혈관모형의 Water Phantom 만을 사용하여 촬영한 영상과 보조기구 위에 Water Phantom을 올려놓고 촬영한 영상의 SNR과 CNR을 비교한 결과 SNR은 약 0.11~0.35(0.78~2.47%), CNR은 약 0.016~0.031(0.18~2.85%) 정도의 낮은 차이를 확인 하였다. Roadmap 기법으로 Water Phantom 만을 사용하여 촬영한 영상과 보조기구(하드보드지, 포맥스, 폴리카보네이트, 아크릴) 위에 water Phantom을 올려놓고 촬영한 영상의 SNR과 CNR을 비교한 결과 SNR은 0.02~0.05(0.54~1.38%), CNR은 0.002~0.004(1.96~3.70%) 정도의 낮은 차이를 확인 하였다. 결과적으로 보조기구를 사용하지 않았을 때와 보조기구(하드보드지, 포맥스, 폴리카보네이트, 아크릴)을 사용하였을 때를 비교 했을때 SNR과 CNR의 차이가 낮아 보조기구의 사용이 화질의 미치는 영향이 적다고 판단된다. 환자 고정을 위한 보조기구의 사용은 움직임에 따른 조영제 사용량 감소, 시간적 측면 감소, 방사선 피폭 감소, 위험요소의 제거 등에 유용하게 사용할 수 있으며, 보조기구 제작에 대한 각각재료들의 장점은 많으나 본 연구에서 하드보드지 경우 다른 재료에 비해 가격이 저렴하고, 가공이 쉬운 장점을 가지고 있어 검사 및 시술에서 쉽게 적용이 가능할 것으로 판단된다. 검사자가 보조기구를 제작하여 사용 할 때 각 검사의 목적 및 방법에 맞게 재질의 특성, 경제성을 고려하여 사용하는 것이 유용할 것으로 판단된다.

자동노출제어장치를 적용한 흉부 측면 방사선검사 시 환자 위치 변화가 주변 장기의 선량에 미치는 영향 (Effects of Change in Patient Position on Radiation Dose to Surrounding Organs During Chest Lateral Radiography with Auto Exposure Control Mode)

  • 김승욱;임청환;주영철;유신영
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.903-909
    • /
    • 2023
  • 본 연구는 자동노출제어장치를 이용한 흉부 측방향 검사 시에 환자의 중심위치 변화가 주변 장기의 피폭선량과 화질에 미치는 영향을 탐구하는데 목적이 있다. 실험은 인체모형팬텀을 대상으로 하였다. 바늘침을 팬텀의 관상선 중심 하단부에 부착하였고, 납 자를 검출기 하단부에 부착하여, 50 cm 지점이 AEC 이온챔버의 중앙 하단부에 위치하도록 하였다. 조사조건은 125 kVp, 320 mA, 초점-영상검출기간 거리는 180 cm, 조사야 크기는 14×17 inch를 사용하였다. AEC 이온 챔버는 중앙-하단 1개만 사용했고, Sensitivity 'Middle', Density '0' 으로 설정하여, 중심 X선은 6번째 흉추를 향해 수직입사 하였다. AEC mode를 적용한 상태에서 바늘침과 납 자의 50 cm 지점이 일치되게 위치시킨 후 팬텀을 배 쪽으로 5 cm (F5), 등 쪽으로 5 cm (B5) 씩 이동시킨 후 ESD를 측정하여 선량 인자를 분석하였다. 환자 중심위치 변화에 따른 갑상선의 ESD는 Center의 경우 232.60±2.20 μGy, F5는 231.22±1.53 μGy, B5는 184.37±1.19 μGy로 나타났으며, 유방의 ESD는 Center의 경우 288.54±3.03 μGy, F5는 260.97±1.93 μGy, B5는 229.80±1.62 μGy, 폐 중심부의 ESD는 Center의 경우 337.02±3.25 μGy, F5는 336.09±2.29 μGy, B5는 261.76±1.68 μGy 로 나타났다. 선량 인자의 각 그룹 간 평균값의 차이를 비교한 결과 통계적으로 유의한 차이가 나타났으며(p<0.01), 각각 독립적인 그룹으로 나타났다. 연구의 결과, 환자 중심위치 변화에 따른 갑상선, 유방, 폐 중심부의 선량의 차이는 환자가 전방 5 cm 정도의 움직임에서는 유방(10%)를 제외한 장기에서는 큰 차이가 없었으나, 후방 5 cm 정도의 움직임에서는 각 부위에서 평균 23.7%의 선량 감소를 나타냈다. 또한, 환자 중심위치가 후방으로 이동 시 화질의 저하가 나타났다.

필터보정역투영과 적절한 커널을 이용한 소아 저선량 안면 컴퓨터단층촬영의 시행 가능성 (Feasibility of Pediatric Low-Dose Facial CT Reconstructed with Filtered Back Projection Using Adequate Kernels)

  • 지혜;유선경;이정은;이소미;조현혜;엄준영
    • 대한영상의학회지
    • /
    • 제83권3호
    • /
    • pp.669-679
    • /
    • 2022
  • 목적 필터보정역투영(filtered back projection; 이하 FBP)법과 적절한 커널로 재구성된 소아 저선량 안면 컴퓨터단층촬영(이하 CT)의 시행 가능성을 평가하고자 한다. 대상과 방법 응급실에서 안면 CT를 촬영한 10세 이하 환자의 임상 및 영상 데이터를 후향적으로 검토하였다. 환자들을 두 그룹으로 나누었다: 고정된 80 kVp와 자동관전류변조기법을 사용하는 저선량 CT (low-dose CT, 그룹 A, n = 73), 고정된 120 kVp와 자동관전류변조기법을 사용하는 표준 선량 CT (standard-dose CT, 그룹 B, n = 40). 모든 영상은 FBP로 재구성되었다: 그룹 A는 뼈와 연조직 커널을, 그룹 B는 뼈 커널을 이용하였다. 두 그룹의 영상 잡음, 신호대잡음비(signal-to-noise ratio; 이하 SNR), 그리고 대조대잡음비(contrast-to-noise ratio; 이하 CNR)를 비교하였다. 두 명의 영상의학과 의사가 뼈와 연조직의 영상 품질에 대해 주관적으로 점수화하였다. 용적 CT 선량지수(CT dose index volume)와 선량길이곱(dose length product)을 기록하였다. 결과 영상 잡음은 그룹 A가 그룹 B보다 높았다(p < 0.001). 연조직 커널을 사용한 그룹 A 영상에서 가장 높은 SNR과 CNR을 보였다(p < 0.001). 뼈의 정성적 평가에서 뼈 커널 영상들을 비교하면 그룹 A가 그룹 B보다 비슷하거나 높은 점수를 보였다. 연조직의 정성적 평가에서 연조직 커널을 이용한 그룹 A와 뼈 커널에 연조직 창 설정을 이용한 그룹 B 사이에는 통계적으로 유의한 차이가 없었다(p > 0.05). 그룹 A는 그룹 B에 비해 방사선 선량이 76.9% 감소했다(3.2 ± 0.2 mGy vs. 13.9 ± 1.5 mGy, p < 0.001). 결론 연조직 커널 영상을 FBP로 재구성된 전통적인 CT에 추가함으로써 영상 품질을 유지하면서 소아 저선량 안면 CT 프로토콜을 사용할 수 있다.

전신 뼈 검사에서 Wide Beam Reconstruction 기법의 유용성 (Utility of Wide Beam Reconstruction in Whole Body Bone Scan)

  • 김정열;강청구;박민수;박훈희;임한상;김재삼;이창호
    • 핵의학기술
    • /
    • 제14권1호
    • /
    • pp.83-89
    • /
    • 2010
  • UltraSPECT사의 Wide Beam Reconstruction (WBR)은 노이즈(Noise)와 조준기의 광속 확산 함수 효과(Beam spread function effect)를 제거하고 환자와의 거리를 자동적으로 보상하여 높은 해상도와 대조도를 제공할 수 있어 영상 획득 시간을 짧게 할 수 있고 상당한 영상 질 향상에 도움을 준다고 보고되고 있다. 이에 본 연구에서는 핵의학 분야에서 가장 흔히 이용되는 전신 뼈 스캔에 대해 WBR의 임상적 적용에 대한 유용성을 알아보고자 한다. XpressBone (WBR)의 성능 실험을 위하여 NEMA에서 제공하는 방법에 의하여 선원(Line source)과 SPECT Phantom을 이용하여 공간 분해능을 측정 분석하였다. 실험방법은 선원의 총 계수치를 200 kcps에서 300 kcps로 변화시켜 측정하였으며, SPECT Phantom은 매트릭스 크기를 변화시켜 측정하여 공간분해능에 대한 분석을 하였다. 또한 2009년 1월부터 2009년 9월까지 본원을 내원하여 뼈 스캔을 시행 받은 환자 40명을 두 군으로 나누어 임상 연구를 시행하였다. 1군은 $^{99m}Tc$-HDP 740 MBq (20mCi)를 투여하고 검사속도(20, 30 cm/min)를 변화시켰고, 2군은 동일한 검사속도에서 $^{99m}Tc$-HDP의 투여량을 변화시켜 영상을 획득하여 Standard data와 WBR기법으로 재구성한 영상을 비교 평가하였다. 분석방법은 대퇴골체부에서 뼈와 연부조직간 섭취비(Femur to tissue ratio: FTR)를 측정한 정량적인 분석과 핵의학과 전문의와 5년 이상의 실무경험을 가진 방사선사가 육안적인 분석을 하여 비교 평가하였다. 성능 실험에서 선원을 사용하여 실험한 결과 Planar WBR data는 Standard data에 비하여 분해능이 약 10% 향상되었으며, WBR 반치폭(Full-Width at Half-Maximum)은 16% 향상되었다(Standard data 8.45, WBR data 7.09). SPECT Phantom에서는 약 50%의 분해능이 향상되었으며, WBR 반치폭은 50% 향상되었다(Standard data 3.52, WBR data 1.65). 임상 연구에서는 $^{99m}Tc$-HDP 투여량을 고정시키고 검사속도를 20cm/min과 30 cm/min로 변화시킨 1군에서 Standard data와 WBR data의 전신 뼈 스캔 전면 영상에서 뼈 대비 연부조직간 섭취비는 통계적으로 유의한 차이를 보이지 않았다 (p=0.07). 검사속도를 고정하고 $^{99m}Tc$-HDP 투여량을 변화시킨 2군에서는 Standard data와 WBR data간의 전신 뼈 스캔전면 영상에서는 통계적으로 유의한 차이를 보이지 않았다 (p=0.458). 영상의 육안적 분석에서도 두 군 간 유의한 차이를 보이지 않았다(p>0.05). NEMA test 결과 WBR 기법의 영상에서 분해능이 향상되는 결과를 나타내었고, 임상 실험에서는 기존 재구성 방법에서의 동일한 해상도를 가지면서도 검사시간을 단축시킬 수 있었으며 방사성의약품의 투여량도 줄일 수 있었다. 이미 알려진 바와 같이 WBR은 노이즈를 감소시켜 신호 대 잡음비를 증강시키는 새로운 영상 재구성 방법임을 확인 할 수 있으며 동일한 검사속도에서 투여량을 감소시킬 수 있어 수신자의 피폭선량 경감과 검사시간을 단축할 수 있었으며 임상 현장에서 유용하게 이용되리라 사료된다.

  • PDF