• Title/Summary/Keyword: Radiation observation

Search Result 369, Processing Time 0.021 seconds

Effect of Citrus Pectin Oligosaccharide Prepared by Irradiation on High Cholesterol Diet B6.KOR-ApoE Mice

  • Kang, Ho-Jin;Kwon, Joong-Ho;Ahn, Dong-Uk;Lee, Ju-Woon;Lee, Wan-Kyu;Jo, Cheo-Run
    • Food Science and Biotechnology
    • /
    • v.18 no.4
    • /
    • pp.884-888
    • /
    • 2009
  • Effect of citrus pectin oligosaccharides produced by irradiation was studied on the ability to improve lipid metabolism and hypercholesterolemia in mice fed high cholesterol diets. A total of 35 mice were divided into 5 groups and fed the following diets for 6 weeks: normal diet (C), 0.5% cholesterol (CH), 0.5% cholesterol+5% non-irradiated pectin (P), 0.5% cholesterol+5% irradiated pectin at 20 kGy (PIR), and 0.5% cholesterol+5% irradiated at 20 kGy and dialyzed (PIR-F). CH group had significantly higher serum triglycerides, total cholesterol, and low density lipoprotein (LDL)-cholesterol contents than pectin oligosaccharide-treated groups (p<0.05). Triglycerides and total cholesterol contents was the lowest in C and PIR-F and followed by PIR and P group, and CH group had significantly higher LDL-cholesterol. Serum high density lipoprotein (HDL)-cholesterol content in C group was not different from that in CH and P groups, but lower than that of PIR and PIR-F groups. These results suggest that pectin oligosaccharides produced by irradiation can reduce the levels of serum triglyceride, total cholesterol, and LDL-cholesterol in the blood of mice fed high-cholesterol diets and therefore, irradiation can be used as a tool to produce functional oligosaccharides from citrus pectin.

Heat Loss Audit and Assessment of the Greenhouses Using Infrared Thermal Image Analysis (적외선 열화상 분석을 통한 온실의 열손실 진단 및 평가)

  • Moon, Jong-Pil;Yun, Nam-Kyu;Lee, Sung-Hyoun;Kim, Hak-Joo;Lee, Su-Jang;Kim, Young-Hwa
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.2
    • /
    • pp.67-73
    • /
    • 2010
  • Unlike Urban building, horticultural facilities has a lot of heat loss through plastic or glass covering material which could be much influential to growing plant and consuming energy for heating greenhouse. In many cases, heat loss from a break of cover, a gap of joint sealing, the entrance to greenhouse and windows for ventilation are the main factors considered in calculating the heating load for horticultural facilities. however the normal observation through human eye and digital camera could not recognize where the heat loss occurred. but the infrared thermal image camera with detecting thermal difference could be very effective for noticing heat loss by analyzing infrared thermal image. In this study, greenhouse structure, covering material, internal and external provisions for Horticultural facilities were surveyed in different sites and Infrared thermal camera shooting and image analysis were performed for auditing heat loss from cultivation facilities The results from this study were that unexpected heat loss had been noticed in 7 representative cases of greenhouse such as side wall covered with single or double plastic, and the joint of horizontal thermal curtain, roof without horizontal thermal curtain, entrance to greenhouse, windows for ventilation. the most important factors for keeping heat energy were whether the horizontal thermal curtain with multifold thermal material was installed or not. The internal or external covering using multifold thermal curtain proved to be the most effective ways to keep heat energy from losing through heat transmission, heat radiation. from inside to outside the horticultural facilities.

DEVELOPMENT OF THE SOLAR EUV TELESCOPE ENGINEERING MODEL FOR A SATELLITE (인공위성 탑재용 극자외선 태양망원경(EUVT) EM 개발)

  • 이선민;장민환;이은석
    • Journal of Astronomy and Space Sciences
    • /
    • v.20 no.4
    • /
    • pp.327-338
    • /
    • 2003
  • The aim of this paper is to describe the results of the study on the extreme-ultra-violet (EUV) solar telescope, which is designed to. a possible satellite mission. Since the EUV band can not be observed on the ground, the observation in EUV should be performed in space using a satellite or a rocket. Design of the Extreme-Ultra-Violet solar Telescope (BUVT) in this study is based on "Designing a small-sized engineering model of solar EUV telescope for a Korean satellite" (Han et al. 2001). Our EUVT design is satisfied with the requirements for a satellite in size and input voltage. The major goal of the study is to confirm if we can detect the specific wavelength (58.4nm to 62.9nm) with the EUVT. We describe re-designing of the EUVT to decrease a shelter ratio. Also we describe the technics in the optic system and the detector, which were used to manufacture the EUVT. We explain the detective program, which is to calculate the amount of the solar radiation, and the image data processing system.ng system.

Statistical Modelling and Forecasting of Cervix Cancer Cases in Radiation Oncology Treatment: A Hospital Based Study from Western Nepal

  • Sathian, Brijesh;Fazil, Abul;Sreedharan, Jayadevan;Pant, Sadip;Kakria, Anjali;Sharan, Krishna;Rajesh, E.;Vishrutha, K.V.;Shetty, Soumya B.;Shahnavaz, Shameema;Rao, Jyothi H.;Marakala, Vijaya
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.3
    • /
    • pp.2097-2100
    • /
    • 2013
  • Background: To estimate the numbers and trends in cervix cancer cases visiting the Radiotherapy Department at Manipal Teaching Hospital, Pokhara, Nepal, statistical modelling from retrospective data was applied. Materials and Methods: A retrospective study was carried out on data for a total of 159 patients treated for cervix cancer at Manipal Teaching Hospital, Pokhara, Nepal, between $28^{th}$ September 2000 and $31^{st}$ December 2008. Theoretical statistics were used for statistical modelling and forecasting. Results: Using curve fitting method, Linear, Logarithmic, Inverse, Quadratic, Cubic, Compound, Power and Exponential growth models were validated. Including the constant term, none of the models fit the data well. Excluding the constant term, the cubic model demonstrated the best fit, with $R^2$=0.871 (p=0.004). In 2008, the observed and estimated numbers of cases were same (12). According to our model, 273 patients with cervical cancer are expected to visit the hospital in 2015. Conclusions: Our data predict a significant increase in cervical cancer cases in this region in the near future. This observation suggests the need for more focus and resource allocation on cervical cancer screening and treatment.

Damage studies on irradiated tungsten by helium ions in a plasma focus device

  • Seyyedhabashy, Mir mohammadreza;Tafreshi, Mohammad Amirhamzeh;bidabadi, Babak Shirani;Shafiei, Sepideh;Nasiri, Ali
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.827-834
    • /
    • 2020
  • Damage of tungsten due to helium ions of a PF device was studied. The tungsten was analyzed by SEM and AFM after irradiation. SEM revealed fine bubbles of helium atoms with diameters of a few nanometers, which join and form larger bubbles and blisters on the surface of tungsten. This observation confirmed the results of molecular dynamics simulation. SEM analysis after etching of the irradiated surface indicated cavities with depth range of 35-85 nm. The average fluence of helium ion of the PF device was calculated about 5.2 × 1015 cm-2 per shot, using Lee code. Energy spectrum of helium ions was estimated using a Thomson parabola spectrometer as a function of dN/dE ∝ E-2.8 in the energy range of 10-200 keV. The characteristics of helium ion beam was imported to SRIM code. SRIM revealed that the maximum DPA and maximum helium concentration occur in the depth range of 20-50 nm. SRIM also showed that at depth of 30 nm, all of the tungsten atoms are displaced after 20 shots, while at depth of higher than 85 nm the destruction is insignificant. There is a close match between SRIM results and the measured depths of cavities in SEM images of tungsten after etching.

ACUTE RESPONSE OF THE RAT INCISOR BY SINGLE AND FRACTIONATED IRRADIATION (단일 및 분할 방사선조사에 의한 백서절치의 급성반응에 관한 연구)

  • Rhee In-Suk;Park Tae-Won;Ahn Hyung-Kyu
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.19 no.1
    • /
    • pp.39-48
    • /
    • 1989
  • Six to eight-month-old female albino rats were used as experimental animals. As an irradiation equipment, a Co-60 was used. The experimental animals were divided to; 6 of the control group, 12 of the 500cGy single irradiation group, 12 of the 1000cGy fractionated irradiation group, and 12 of the 1500cGy fractionated irradiation group. From the first week to the forth, 3 rats were picked from each group every week to be sacrificed and fixed with formalin. Those rats were observed by means of H-E stain after being taken radiograph and decalcified. The analysis of radiographic findings and light microscopic findings gives results as follows: 1. The delay of dental eruption rate was found in every group which underwent the irradiation experiment. Dentin niche, osteodentin, and dentin island were formed in the parts which were damaged by the irradiation. 2. The longer the observation period was, the more deposit of osteodentin and dentin island was formed. 3. In the single irradiation group, the damage effect was in proportion to the increase of radiation dose, whereas the damage was much less in the fractionated group receiving the same dose. 4. The 500cGy single irradiation group got temporary repairable damage, while the 1000cGy single irradiation group got considerable damage and showed much slower eruption rate than the 500cGy single irradiation group. The basal portion of the 1500cGy single irradiation group, whose growth was arrested, was destroyed. 5. The fractionated group were irradiated 500cGy everyweek. Repair was visible during the interval periods. The damage was accumulated as irradiation repeated, but degree of damage was lower than that of the 1000cGy and 1500cGy single irradiation group.

  • PDF

NECK DISSECTION OF CLINICALLY NO NECK OF ORAL SQUAMOUS CELL CARCINOMA & PATHOLOGIC COMPARISON (구강편평세포암종에서 임상적 N0 경부의 경부 곽청술 후 병리학적인 비교)

  • Kang, Jin-Han;Ahn, Kang-Min;Lee, Sang-Woo;Myoung, Hoon;Lee, Jong-Ho;Kim, Myung-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.6
    • /
    • pp.591-596
    • /
    • 2007
  • Neck node metastasis of oral cancer can be diagnosed by bimanual palpation, CT, MRI and neck sonography and the final diagnosis can be confirmed by pathologic evaluation of the neck nodes after elective neck dissection. When we meet clinically negative neck node(N0 neck) of oral squamous cell carcinoma, the treatment modality of the neck nodes with the primary lesions are so controversial. The usually used methods are various from close observation to elective radiation and elective neck dissection. The methods can be chosen by the primary size of the carcinoma, site of the lesions and the expected percentage of the occult metastasis to the neck. We reviewed the 86 patients from 1996 to 2006 who were diagnosed as oral squamous cell carcinoma, whose necks were diagnosed negative in radiographically and clinically. According to TNM stage, the patients were in the states of N0 and treated by surgery using mass excision and elective neck dissection. We compared the differences between the clinical diagnoses and pathologic reports and would discuss the needs for elective neck dissection.

Statistical Analysis on the trapping boundary of outer radiation belt during geosynchronous electron flux dropout : THEMIS observation

  • Hwang, Jung-A;Lee, Dae-Young;Kim, Kyung-Chan;Choi, Eun-Jin;Shin, Dae-Kyu;Kim, Jin-Hee;Cho, Jung-Hee
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.90.2-90.2
    • /
    • 2012
  • Geosynchronous electron flux dropouts are most likely due to fast drift loss of the particles to the magnetopause (or equivalently, the "magnetopause shadowing effect"). A possible effect related to the drift loss is the radial diffusion of PSD due to gradient of PSD set by the drift loss effect at an outer L region. This possibly implies that the drift loss can affect the flux levels even inside the trapping boundary. We recently investigated the details of such diffusion process by solving the diffusion equation with a set of initial and boundary conditions set by the drift loss. Motivated by the simulation work, we have examined observationally the energy spectrum and pitch angle distribution near trapping boundary during the geosynchronous flux dropouts. For this work, we have first identified a list of geosynchronous flux dropout events for 2007-2010 from GOES satellite electron measurements and solar wind pressures observed by ACE satellite. We have then used the electron data from the Time History of Events and Macroscale Interactions during Substorms (THEMIS) spacecraft measurements to investigate the particle fluxes. The five THEMIS spacecraft sufficiently cover the inner magnetospheric regions near the equatorial plane and thus provide us with data of much higher spatial resolution. In this paper, we report the results of our investigations on the energy spectrum and pitch angle distribution near trapping boundary during the geosynchronous flux dropout events and discuss implications on the effects of the drift loss on the flux levels at inner L regions.

  • PDF

Clinical Observation and Prognostic Analysis of Pemetrexed plus Platinum as First-line Treatment in Patients with Advanced Non-small Cell Lung Cancer

  • Wang, Ji-Ying;Cai, Yong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.11
    • /
    • pp.6267-6271
    • /
    • 2013
  • Objective: To determine clinical efficacy, safety and prognostic factors of pemetrexed plus platinum as first-line treatment in patients with advanced non-small cell lung cancer (NSCLC). Materials and Methods: Clinical characteristics, short-term efficacy, survival and adverse reactions of 47 advanced non-squamous NSCLC patients who had received pemetrexed plus platinum as first-line treatment in Shanghai Pulmonary Hospital from January 2009 to June 2011 were retrospectively analyzed. The Chi-squared test was applied to statistically analyze the overall response rate (ORR), disease control rate (DCR) and toxicity reactions in both groups, while survival data wereanalyzed by Kaplan-Meier and logrank methods, and the COX proportional hazards model was adopted for a series of multi-factor analyses. Results: Only two patients were lost to follow-up. The ORR, DCR, medium progression-free survival time (PFS) and medium overall survival (OS) were 31.9%, 74.5%, 5 months and 15.2 months, while 1- and 2-year survival rates were 63.8% (30/47) and 19.2% (9/47), respectively. Single-factor analysis showed that tumor pathological patterns and efficacy were in association with medium PFS (P<0.05), whereas tumor pathological patterns, smoking history and efficacy were closely connected with medium OS (P<0.05). Multi-factor analyses demonstrated that pathological patterns and efficacy were independent factors influencing OS (P<0.05). The rate of toxicity reactions in degree III/IV was low, including hematologic toxicity marked by decline in white blood cell count and decrease in the platelet count (PLT), and non-hematologic toxicity manifested by gastrointestinal reactions, such as nausea and vomiting. Conclusions: Pemetrexed plus platinum as first-line treatment has excellent efficacy and slight adverse reactions with favorable drug-tolerance in patients with advanced non-squamous NSCLC.

VALIDATION OF SEA ICE MOTION DERIVED FROM AMSR-E AND SSM/I DATA USING MODIS DATA

  • Yaguchi, Ryota;Cho, Ko-Hei
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.301-304
    • /
    • 2008
  • Since longer wavelength microwave radiation can penetrate clouds, satellite passive microwave sensors can observe sea ice of the entire polar region on a daily basis. Thus, it is becoming popular to derive sea ice motion vectors from a pair of satellite passive microwave sensor images observed at one or few day interval. Usually, the accuracies of derived vectors are validated by comparing with the position data of drifting buoys. However, the number of buoys for validation is always quite limited compared to a large number of vectors derived from satellite images. In this study, the sea ice motion vectors automatically derived from pairs of AMSR-E 89GHz images (IFOV = 3.5 ${\times}$ 5.9km) by an image-to-image cross correlation were validated by comparing with sea ice motion vectors manually derived from pairs of cloudless MODIS images (IFOV=250 ${\times}$ 250m). Since AMSR-E and MODIS are both on the same Aqua satellite of NASA, the observation time of both sensors are the same. The relative errors of AMSR-E vectors against MODIS vectors were calculated. The accuracy validation has been conducted for 5 scenes. If we accept relative error of less than 30% as correct vectors, 75% to 92% of AMSR-E vectors derived from one scene were correct. On the other hand, the percentage of correct sea ice vectors derived from a pair of SSM/I 85GHz images (IFOV = 15 ${\times}$ 13km) observed nearly simultaneously with one of the AMSR-E images was 46%. The difference of the accuracy between AMSR-E and SSM/I is reflecting the difference of IFOV. The accuracies of H and V polarization were different from scene to scene, which may reflect the difference of sea ice distributions and their snow cover of each scene.

  • PDF