• Title/Summary/Keyword: Radiation devices

Search Result 499, Processing Time 0.026 seconds

Analysis of the Imaging Dose for IGRT/Gated Treatments (영상유도 및 호흡동조 방사선치료에서의 영상장비에 의한 흡수선량 분석)

  • Shin, Jung-Suk;Han, Young-Yih;Ju, Sang-Gyu;Shin, Eun-Hyuk;Hong, Chae-Seon;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.27 no.1
    • /
    • pp.42-48
    • /
    • 2009
  • Purpose: The introduction of image guided radiation therapy/four-dimensional radiation therapy (IGRT/4DRT) potentially increases the accumulated dose to patients from imaging and verification processes as compared to conventional practice. It is therefore essential to investigate the level of the imaging dose to patients when IGRT/4DRT devices are installed. The imaging dose level was monitored and was compared with the use of pre-IGRT practice. Materials and Methods: A four-dimensional CT (4DCT) unit (GE, Ultra Light Speed 16), a simulator (Varian Acuity) and Varian IX unit with an on-board imager (OBI) and cone beam CT (CBCT) were installed. The surface doses to a RANDO phantom (The Phantom Laboratory, Salem, NY USA) were measured with the newly installed devices and with pre-existing devices including a single slice CT scanner (GE, Light Speed), a simulator (Varian Ximatron) and L-gram linear accelerator (Varian, 2100C Linac). The surface doses were measured using thermo luminescent dosimeters (TLDs) at eight sites-the brain, eye, thyroid, chest, abdomen, ovary, prostate and pelvis. Results: Compared to imaging with the use of single slice non-gated CT, the use of 4DCT imaging increased the dose to the chest and abdomen approximately ten-fold ($1.74{\pm}0.34$ cGy versus $23.23{\pm}3.67$cGy). Imaging doses with the use of the Acuity simulator were smaller than doses with the use of the Ximatron simulator, which were $0.91{\pm}0.89$ cGy versus $6.77{\pm}3.56$ cGy, respectively. The dose with the use of the electronic portal imaging device (EPID; Varian IX unit) was approximately 50% of the dose with the use of the L-gram linear accelerator ($1.83{\pm}0.36$ cGy versus $3.80{\pm}1.67$ cGy). The dose from the OBI for fluoroscopy and low-dose mode CBCT were $0.97{\pm}0.34$ cGy and $2.3{\pm}0.67$ cGy, respectively. Conclusion: The use of 4DCT is the major source of an increase of the radiation (imaging) dose to patients. OBI and CBCT doses were small, but the accumulated dose associated with everyday verification need to be considered.

Phase Controlled Thin Film Loop Antenna for Multi-media Devices (멀티미디어단말기용 박막형 위상제어루프 안테나)

  • Shin, Cheon-Woo
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.7
    • /
    • pp.971-978
    • /
    • 2009
  • The paper is a phase controlled loop antenna for multi-media devices. We developed a phase control loop pattern arrangement methods for loop antenna in mobile devices like as a cell phone and PCS, WCDMA. In the loop antenna pattern, arrange close adhesive the loop antenna pattern $180^\circ$ cycle in wave length, the radiated electro-magnetic wave from close adhesive loop pattern become to coherent wave than the phase controlled loop antenna has high efficiency and high radiation gain. To acquire a wide band width on phase controlled loop antenna, we arrange a multiple phase controlled loop pattern that has a different length each other. Different length for each other loop pattern cause a different frequency that we can acquire a wide band width for loop antenna from close adhesive phase control. In experiment, we designed a CDMA850 mobile multi-media antenna in 20mm$\times$20mm area thickness 0.4mm, the radiation efficiency is over 60% and radiation gain is over 0dBi.

  • PDF

Tunable-Slot-Type Ground Radiation Antenna with Dual Band Operation Using LC Resonator

  • Zahid, Zeeshan;Kim, Hyeongdong
    • Journal of electromagnetic engineering and science
    • /
    • v.17 no.2
    • /
    • pp.71-75
    • /
    • 2017
  • A dual-band tunable-slot-type ground radiation antenna is proposed. The feeding structure consists of a coplanar waveguide and a lumped capacitor to excite currents for first- and second-order resonant modes of the ground. The resonant frequencies of both bands are controlled using a series combination of a capacitor and an inductor. The proposed design may be an attractive choice for mobile devices owing to its compact geometry and tunable operating frequencies. The measurement and simulation results of the proposed antenna show good agreement, indicating good impedance matching and radiation performance.

Visualization of Laser-Produced, Xe Gas Plasma in EUV Light Sources for the Lithography (EUV 리소그라피 광원용 레이저 생성 Xe 가스 플라즈마의 가시화)

  • Jin Yun-Sik;Jeong Sun-Sin;Kim Jong-Uk;Kim Chang-Beom;Kim Yong-Ju
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2002.07a
    • /
    • pp.106-107
    • /
    • 2002
  • Extreme ultraviolet (EUV) radiation of wavelength $\lambda$~10 nm or photon energy hv~100 eV is presently a blank region in the electromagnetic spectrum where applications are concerned. This is because no powerful sources were available until when intense-laser-produced plasmas are available. Both a new laboratory-sized source of EUV radiation and its new applications in lithography of semiconductor devices have been developed. (omitted)

  • PDF

Synchrotron Radiation Induced Photochemical Reactions for Semiconductor Processes

  • Rhee, Shi-Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.3 no.2
    • /
    • pp.147-157
    • /
    • 1994
  • Valence or core electron excitations induced by Synchrotron radiation (SR) irradiation and ensuing chemical reactions can be applied for semiconductor processes i, e, deposition etching and modifications of thin film materials. Unique selectivity can be achieved by this photochemical reactions in deposition and etching. Some materials can be ecvaporated by SR irradiation which can be utilized for low temperature surface cleaning of thin films. Also SR irradiation significantly lowers the reaction temperature and photon activated surface reactions can be utilized for direct writing or projection lithography of electronic materials. This technique is especially effective in making nanoscale feature size with abrupt and well defined interfaces for next generation electronic devices.

  • PDF

Development of Devices for Improving the Reducibility of Patient Positioning on a Breast Board (Breast Board를 이용한 방사선치료에서 환자 위치 재현성 향상 방안에 대한 연구)

  • Huh Soon Nyung;Cho Woong;Park Yang Kyun;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.23 no.2
    • /
    • pp.123-130
    • /
    • 2005
  • Purpose: We wanted to improve the setup reproducibility of breast cancer patients when utilizing a commercially available breast board for radiation therapy. The breast board was modified by using a new head rest and 2 types of board fixation devices. Materials and Methods: A conventional head/neck rest was modified to be positioned in various slots of the breast board, and it was fabricated 1 cm thinner to provide more comfort to a patient when the patient's neck was rotated. This rest improves the uncertainty of the daily setup. Also, the sagging problems at the left and right sides became negligible with the two types of board fixation devices: (1) the stair type, and (2) the arm type. The first device consists of an upper/lower holder with 4 stair-types of grooves and 4 rectangular Inserts. In order to cover the whole range of vertical setup of the breast board, 4 rectangular inserts were needed, and each covered 10 steps. The arm-type fixation device was also fabricated and attached to the breast board, It had two aluminum bars that were fixed by utilizing a lock-type of screw. These devises were evaluated with two volunteers in order to prove the effectiveness of the improved setup accuracy. Results; The developed cranio-caudal fixation device demonstrated that it could reduce the cranio-caudal error by nearly $55\%$ compared to the old device. As for left-and-right inclination, the stair-type and arm-type fixation devices can reduce the relative inclination by nearly $80\%$ and $90\%$, respectively, compared to the breast board without the fixation device. Conclusion: It was verified that the developed devices were effective for positioning the patients and for avoiding inclination of the breast board.

Intercomparison of the KAERI Reference Photon and Beta Radiation Measurements (한국원자력연구소 기준 광자 및 베타선장 측정의 국제상호비교)

  • Chang, Si-Yeong;Kim, Bong-Hwan;Kim, Jang-Lyul;McDonald, J.C.;Murphy, M.K.
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.4
    • /
    • pp.255-262
    • /
    • 1996
  • This paper describes the results of intercomparison measurements of KAERI reference photon and beta radiation fields between the KAERI and the PNNL(Pacific Northwest National Laboratory), recently performed at KAERI radiation calibration and dosimetry laboratory on the basis of the ANSI N13.11 criteria for personal dosimeter performance test. Each laboratory used her own radiation detectors or measurement devices traceable to her national primary standard in measuring the exposure rates for photon fields, the absorbed dose rates for beta radiation fields. The agreements in reference radiation measurements between two laboratories were found to be less than ${\pm}2.0%$ for photon fields, ${\pm}1.0%$ for beta radiation fields. Therefore, it could be concluded that KAERI reference radiation fields comply well with the international standard and thus can further serve as a national basis for the researches and developments in radiation protection dosimetry in Korea.

  • PDF

DataBase system construction for the study of radiation hardened electronic devices using pulse radiation (펄스방사선을 이용한 내방사선 연구 DB 구축)

  • Ko, Seong-Gon;Oh, Seung-Chan;Hwang, Young-Gwan;Jeong, Sang-Hun;Lee, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.778-781
    • /
    • 2012
  • The electronic element the damage occurs with radiation being bombed. In order applies in the artificial satellite or the space ship therefore from the within has radiation introspection the use of the radiation electronic element is essential. Transient radiation tests performed for the first time in Korea evaluation data database (DB) was constructed to. Web-based materials in the DB is designed to be able to search and update, and existing foreign (NASA, ESA) for a total of 695 species, including public sources of data has been entered. Search DB than the existing foreign DB is an efficient and practical.

  • PDF

The Study of Latch-up (과도방사선 조건에서 PN다이오드소자의 방사선 영향분석)

  • Oh, Seung-Chan;Jeong, Sanghun;Hwang, YoungGwan;Lee, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.791-794
    • /
    • 2013
  • Electronic systems may be cause of various serious failures due to an ionizing radiation effect when exposed to a prompt gamma-ray pulse. This transient electrical malfunction can, in some cases, results in a failure of the electronic system of which the circuits are a part. Transient radiation measurement and evaluation system is required to development for enhanced radiation-resistance against the initial nuclear radiation produced by the detonation of a nuclear weapon of semiconductor devices. In these studies, we performed the following work. In the first part of the work, we carried out a SPICE simulation applied to nuclear radiation condition for PN diode and we also investigated the photocurrent by a pulsed gamma-ray on a PN diode using a TCAD simulation.

  • PDF

Understanding radiation effects in SRAM-based field programmable gate arrays for implementing instrumentation and control systems of nuclear power plants

  • Nidhin, T.S.;Bhattacharyya, Anindya;Behera, R.P.;Jayanthi, T.;Velusamy, K.
    • Nuclear Engineering and Technology
    • /
    • v.49 no.8
    • /
    • pp.1589-1599
    • /
    • 2017
  • Field programmable gate arrays (FPGAs) are getting more attention in safety-related and safety-critical application development of nuclear power plant instrumentation and control systems. The high logic density and advancements in architectural features make static random access memory (SRAM)-based FPGAs suitable for complex design implementations. Devices deployed in the nuclear environment face radiation particle strike that causes transient and permanent failures. The major reasons for failures are total ionization dose effects, displacement damage dose effects, and single event effects. Different from the case of space applications, soft errors are the major concern in terrestrial applications. In this article, a review of radiation effects on FPGAs is presented, especially soft errors in SRAM-based FPGAs. Single event upset (SEU) shows a high probability of error in the dependable application development in FPGAs. This survey covers the main sources of radiation and its effects on FPGAs, with emphasis on SEUs as well as on the measurement of radiation upset sensitivity and irradiation experimental results at various facilities. This article also presents a comparison between the major SEU mitigation techniques in the configuration memory and user logics of SRAM-based FPGAs.