• Title/Summary/Keyword: Radiation convergence shields

Search Result 6, Processing Time 0.017 seconds

Evaluation of Surface Radiation Dose Reduction and Radiograph Artifact Images in Computed Tomography on the Radiation Convergence Shield by Using Sea-Shells (전산화단층영상장비에서 패각을 이용한 방사선 융합차폐체의 표면 방사선량 감소율과 방사선 인공물 영상 평가)

  • Seoung, Youl-Hun
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.2
    • /
    • pp.113-120
    • /
    • 2017
  • The purpose of this present study was to evaluate the surface radiation dose reduction and radiograph artifact images in computed tomography (CT) for the manufactured radiation shields by using sea-shells. The radiation convergence shields were made from silicons, sea-shells, barium powders, producted circle types of diameter 50 mm, thickness 3.5 mm for 5 kinds (only silicon shield, only barium shield, mixed sea-shells with silicon shield, mixed barium with silicon shield, mixed sea-shells with barium and silicon shield). Radiation generation and acquisition were used 4-channel multi-detector CT. The results of this study showed that mixed sea-shells with silicon shields could reduce the surface dose of 5.3% without radiograph artifact images. In the future, we will expect the radiation convergence shield as environmentally friendly materials by using the recycling of sea-shells with the advantages of silicon which can make various shapes.

A study on the usefulness of a fusion model designed cloak shield to reduce the radiation exposure of the assistant during CT of severely injured patient (중증외상환자 CT 검사 시 검사보조자의 방사선피폭 경감을 위한 융합적 망토 차폐체의 유용성 연구)

  • Seo, Sun-Youl;Han, Man-Seok;Kim, Chang-Gyu;Jeon, Min-Cheol;Kim, Yong-Kyun;Kim, Gab-Jung
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.9
    • /
    • pp.211-216
    • /
    • 2017
  • The purpose of this study is to evaluate the usefulness of a newly fusion model designed cloak shield to reduce the radiation exposure of the assistant during CT(computed tomography) of severely injured patient. Radiation dose was measured in the heart, both axillary and thyroid areas using newly designed cloak shield and existing shield with head phantom and human phantom under the same conditions as brain vascular CT scan. The newly designed cloak shield was measured higher for radiation shielding rate than the existing shields, 61.9 % for heart, 46.2 % for left axillary, 69.8 % for right axillary and 71.1 % for thyroid gland, respectively. a newly developed fusion model of cloak shields are useful for reducing radiation exposure. It is expected to make a significant contribution to reduction of radiation exposure.

Study of occupational exposure in PET/CT (PET/CT 종사자의 방사선피폭에 관한 연구)

  • Na, Soo-Kyung;Park, Byung-Sub;Kang, Yong-Gil
    • Journal of Digital Convergence
    • /
    • v.10 no.11
    • /
    • pp.449-457
    • /
    • 2012
  • The purpose of this study is to investigate the relationship between radiation origin and health professionals, and to reduce exposed dose of radiation through efficient management. Increasing exposed dose of radiation to health professionals are caused by the increase of PET/CT use and a radioactive isotope. Hence, in this study, space dose from each origin of radiation generating was analyzed and the use of personnel protective clothing and shields was compared. As a result of this study, we confirmed that the exposed dose of radiation was much higher in case of wearing personnel protective clothing(0.5 mm pb) than no wearing personnel protective clothing under high energy gamma radiation(511 keV) of the position emitter($^{18}F$).

Analysis of Radiation Fusion Shielding Performance of Ytterbium Oxide, a Radiation Impermeable Substance (방사선 불투과성 물질 산화이테르븀(Ytterbium oxide)의 방사선 융합 차폐성능 분석)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.4
    • /
    • pp.87-94
    • /
    • 2021
  • While the shielding substances of radiation shields in medical institutions are beginning to be replaced by environmentally friendly materials, radiation protection according to the shielding properties of environmentally friendly substances is becoming an important factor rather than the existing lead shielding properties. Tungsten and barium sulfate are representative shielding materials similar to lead, and are made in sheets or fiber form with eco-friendly materials. Ytterbium is an impermeable material used as a fluorine compound in the dental radiation field. This study aims to evaluate the shielding performance in the x-ray shielding area by comparing the shielding properties of ytterbium by energy band and that of existing eco-friendly materials. When three types of shielding sheets were fabricated and tested under the same process conditions, the shielding performance of the medical radiation area was about 5 % difference from tungsten. Furthermore, shielding performance was superior to barium sulfate. In the cross-sectional structure of the shielding sheet, there was a disadvantage that the arrangement of particles was not uniform. Ytterbium oxide showed sufficient potential as a medical radiation shielding material, and it is thought that it can improve the shielding performance by controlling the particle arrangement structure and particle size.

Comparative Evaluation of Shielding Performance according to the Characteristics of Eco-friendly Shielding Material Tungsten (친환경 차폐재료 텅스텐 특성에 따른 차폐성능 평가)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.10
    • /
    • pp.129-136
    • /
    • 2021
  • Radiation shields used in medical institutions mainly use lead to manufacture products and fitments. Although lead has excellent processability and economic efficiency, its use is being reduced due to environmental issues when it is disposed of. In addition, when used for a long time, there is a limit to using it as a shielding film, shielding wall, medical device parts, etc. due to cracking and sagging due to gravity. To solve this problem, copper, tin, etc. are used, but tungsten is mostly used because there is a difficulty in the manufacturing process to control the shielding performance. However, it is difficult to compare with other shielding materials because the characteristics according to the type of tungsten are not well presented. Therefore, in this study, a medical radiation shielding sheet was manufactured in the same process using pure tungsten, tungsten carbide, and tungsten oxide, and the particle composition and shielding performance of the sheet cross-section were compared.As a result of comparison, it was found that the shielding performance was excellent in the order of pure tungsten, tungsten carbide, and tungsten oxide.

Development and Performance Evaluation of X-Ray Shields using Fe2O3 and Al2O3 (산화철, 알루미나를 이용한 X선 차폐체 개발 및 성능 평가)

  • Hui-Su, Yang;Ji-Hwan, Kim;Min-Cheol, Jeon
    • Journal of Advanced Technology Convergence
    • /
    • v.1 no.2
    • /
    • pp.19-25
    • /
    • 2022
  • It is intended to evaluate the performance of the shield after manufacturing a shield with cheap and eco-friendly iron oxide and alumina instead of lead, which is a radiation shielding material. After manufacturing the shield by mixing iron oxide and alumina with gypsum, the performance is evaluated by comparing it with gypsum board and lead apron using an X-ray tube. As a result of the experiment, the shielding performance of alumina was lower than that of the gypsum board, and when 50% of alumina was contained, the shielding performance was similar to that of the gypsum board. Iron oxide became similar to the shielding performance of lead apron when it contained about 75%. A shielding material using alumina shows shielding performance similar to that of gypsum, so it is not suitable as a substitute for lead. However, since iron oxide exhibits similar shielding performance to lead, it can be used as an X-ray shielding material to replace lead in the future, so further research is needed.