• Title/Summary/Keyword: Radiation Usage

Search Result 106, Processing Time 0.024 seconds

A Study on the Stability of Carpet by Thermal Decomposition (열분해에 의한 카펫의 안정성에 관한 연구)

  • Park, Keun-Ho;Lee, Ki-Cheol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.147-152
    • /
    • 2006
  • The accidents occurred by unstable material which is easily exploded or burnt up were caused by heat and collision under the condition of relatively low temperature without oxygen, have been reported frequently. However, the amount of the unstable material is getting higher by development of fine ceramic research area even though its dangerous characteristic is disregarded. This research studied a heat stability and measured boiling point of various carpet material. Carpet has been used in home as well as general indoor usage. Now a day, carpet material which is hardly burnt has been on commercial, but its detailed unstable conditions is not mentioned. This research reports the measurement of the initial temperature of generation heat and heat-radiation change on differential scanning calorimeter (DSC). The DSC data of nylon bulked continuous filament (N-BCF) yam 100%, nylon (NY), poly propylene (PP), and a new material named polytrimethylene terephthalate (PTT) are studied and researched about the effect of them using TGA, furnace, and direct-burning experiment.

Radiotherapy for Benign Diseases (양성질환의 방사선치료)

  • Choi, Sang Gyu
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.611-618
    • /
    • 2016
  • Radiotherapy, as a major 3 standard treatment for cancer, traditionally it has been useful treatment that aim of curative or palliative setting. In addition to some proliferative or inflammatory benign disease are also included in field of radiotherapy. Unlike cancer, in the case of benign disease, it shows good treatment result from usage of some medication, conservative management or surgery. But if fail of these treatment or impossible, low dose radiotherapy is use adjuvant or replacement treatment so that there are no harmful side effect result in safety and easy management for reduce pain or recurrence. Recently, the technical advances in radiotherapy that have been achieved make preservation of normal tissue and the clinical application of high precision radiotherapy focus to selective lesions is possible, and it makes useful treatment in senile patients especially.

A Review on Photodegradable Plastics as a Packaging Material (광분해성 플라스틱의 패키징 소재의 고찰과 적용)

  • Jang, Si-Hoon;You, Young-Sun;Lee, Youn-Suk;Kim, Jai-Neung;Park, Su-Il
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.14 no.2
    • /
    • pp.81-88
    • /
    • 2008
  • There are increasing public concerns that the disposal of most synthetic carbon-based plastics is a great threat to the environment. These have led to intensive research and development of degradable plastics, such as biodegradable plastics, photodegradable plastics, and multi-degradable plastics. Although these degradable plastics may not completely replace common synthetic plastics, these minimize environmental impacts caused by non degradable plastics. Photodegradable plastics are synthetic polymers into which have been incorporated copolymers or light-sensitive additives to weaken the structural bonds in polymer chains when exposed to UV radiation. A better understanding of photodegradable plastics, which also play an important role in the degradation of multi-degradable plastics, will expand the usage of degradable plastics. The aim of present article is to review the formation, degradation mechanism and properties of photodegradable plastics.

  • PDF

A Broadband Microstrip Array Antenna for PCS/IMT-2000 Base-Station (PCS/IMT-2000 기지국용 광대역 마이크로스트립 배열 안테나)

  • 김태우;최재훈
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.11B
    • /
    • pp.1620-1627
    • /
    • 2001
  • In this paper, a broadband microstrip antenna for PCS and IMT-2000 service is designed. To obtain the broadband characteristics of an antenna, we utilized the multi-layered structure composed of two foam material layers, parasitic element and aperture coupled feeding network. The broadband characteristic is obtained by changing the size of parasitic element and the height of foam materials. In addition to that, the usage of metal layer at the distance of λ/4 from feed-line, back radiation is reduced. The bandwidth of a single element for VSWR less than 1.3 is about 550MHz. The bandwidth of a designed 1$\times$4 array antenna for VSWR less than 1.3 is about 460MHz. The gain of a designed array antenna is about 11.15∼12.15dBi and the front-to-back ratio is about 30dB.

  • PDF

A Comparative Study on Output of Four Type Diagnostic X-ray Equipments (정류방식에 따른 진단용 X-선 장치의 출력비교)

  • Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.20 no.2
    • /
    • pp.34-43
    • /
    • 1997
  • There are 4 types of equipment in diagnostic radiography. These are single phase, three phase, inverter type and condenser type X-ray generators. It is very confusing to make an adequate exposure factor and to know the usage of different type of X-ray generators. In this experiment, I explored a comparative study of outputs in 4 different type of X-ray units. I expect that this experiment could be helpful for manufacturer to make both the X-ray equipment better, In terms of Ideal exposure factors, thereby reducing the patient dose. Experimental results are as follow : 1) X-ray output The ratio of X-ray output of single, three phase and inverter type of X-ray generator was 1 : 1.6 : 2 without absorber and 1 : 2 : 2.6 with 20 mm aluminium absorber. 2) Beam quality The X-ray beam quality of single phase generator was proved to be softer than three phase and inverter type of generators by 0.4 mmAL and 0.55 mmAl HVL respectively. 3) Reproducibility Linearity of X-ray output Retroducibility of X-ray output met the regulation below CV 0.05 and linearity also met the regulation below 0.1 in 4 types of diagnostic X-ray generators. 4) The comparison of incident dose Three phase X-ray generator was 20% higher than two other X-ray generators in radiation dose to make same film density.

  • PDF

Suggestion of Efficient High Dose Spent Filter Handling and Compaction Equipment

  • Lee, Kyungho;Chung, Sewon;Park, Seonghee;Kim, HuiGyeong
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.20 no.2
    • /
    • pp.243-253
    • /
    • 2022
  • Spent filters with a high radiation dose rate of 2 mSv·hr-1 or more are not easily managed. So far, the Korean policy for spent filter disposal is to store them temporarily at nuclear power plants until the waste filters can be easily managed. Nuclear power plant decommissioning in Korea is starting with Kori unit 1. Volume reduction of waste generated during decommissioning can reduce the cost and optimize the space usage at disposal site. Therefore, efficient volume reduction is a very important factor during the decommissioning process. A conceptual method, based on the experiences of developing 200 and 800 ton compactors at Orion EnC, has been developed considering worker exposure with the followings a crusher (upgrade of compaction efficiency), an automatic dose measuring system with a NaI(Tl) detector, a shield box, an inner drum to prepare for easy handling of drums and packaging, a 30 ton compactor, and an automatic robot system. This system achieves a volume reduction ratio of up to 85.7%; hence, the system can reduce the disposal cost and waste volume. It can be applied to other types of wastes that are not easily managed due to high dose rates and remote control operation necessity.

Mid- and Short-term Power Generation Forecasting using Hybrid Model (하이브리드 모델을 이용하여 중단기 태양발전량 예측)

  • Nam-Rye Son
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.4_2
    • /
    • pp.715-724
    • /
    • 2023
  • Solar energy forecasting is essential for (1) power system planning, management, and operation, requiring accurate predictions. It is crucial for (2) ensuring a continuous and sustainable power supply to customers and (3) optimizing the operation and control of renewable energy systems and the electricity market. Recently, research has been focusing on developing solar energy forecasting models that can provide daily plans for power usage and production and be verified in the electricity market. In these prediction models, various data, including solar energy generation and climate data, are chosen to be utilized in the forecasting process. The most commonly used climate data (such as temperature, relative humidity, precipitation, solar radiation, and wind speed) significantly influence the fluctuations in solar energy generation based on weather conditions. Therefore, this paper proposes a hybrid forecasting model by combining the strengths of the Prophet model and the GRU model, which exhibits excellent predictive performance. The forecasting periods for solar energy generation are tested in short-term (2 days, 7 days) and medium-term (15 days, 30 days) scenarios. The experimental results demonstrate that the proposed approach outperforms the conventional Prophet model by more than twice in terms of Root Mean Square Error (RMSE) and surpasses the modified GRU model by more than 1.5 times, showcasing superior performance.

Improving usage of the Korea Meteorological Administration's Digital Forecasts in Agriculture: III. Correction for Advection Effect on Determination of Daily Maximum Temperature Over Sloped Surfaces (기상청 동네예보의 영농활용도 증진을 위한 방안: III. 사면 일 최고기온 결정에 미치는 이류효과 보정)

  • Kim, Soo-Ock;Yun, Jin I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.16 no.4
    • /
    • pp.297-303
    • /
    • 2014
  • The effect of solar irradiance has been used to estimate daily maximum temperature, which make it possible to reduce the error inherent to lapse-rate based elevation difference correction in mountainous terrain. Still, recent observations indicated that the effect of solar radiation would need correction for estimation of daily maximum temperature. It was attempted to examine what would cause the variability of solar irradiance effect in determination of daily maximum temperature under natural field conditions and to suggest improved methods for estimation of the temperature distribution over mountainous regions. Temperature at 1500 and the wind speed for 1100 to 1500 were obtained at 10 validation sites with various topographical features including slope and aspect within a mountainous $50km^2$ catchment for 2012-2013. Lapse-rate corrected temperature estimates on clear days were compared with these observations, which would represent the differential irradiance effect among sloped surfaces. Results indicated a negative correlation between the mean wind speed and the estimation error. A simple scheme was derived from relationship between wind speed and estimation error for daily temperature to correct the effect of solar radiation. This scheme was incorporated into an existing model to estimate daily maximum temperature based on the effect of solar radiation. At 10 validation sites on clear days, estimates of 1500 LST temperature with and without the correction scheme were compared. It was found that a substantial improvement was achieved when the correction scheme was applied in terms of bias correction as well as error size reduction at all sites.

Quantitative Evaluation of Image Quality using Automatic Exposure Control & Sensitivity in the Digital Chest Image (디지털 흉부영상에서 자동노출제어 및 감도변화를 이용한 영상품질의 정량적인 평가)

  • Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Kim, Dong-Hyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.275-283
    • /
    • 2013
  • The patient radiation dose is different depending on selection of Ion chamber when taking Chest PA which using AEC. In this paper, we studied acquiring the best diagnostic images according to selection of Ion chamber on AEC mode as well as minimizing patient radiation dose. Experimental methods were selection of Ion chamber and change of sensitivity under the same conditions as Chest PA projection. At AEC mode, two upper ion chambers sensors and one lower ion chamber sensor were divided into 7 cases according to selection of on/off. after measuring five times respectively, we obtained average value and calculated exposure dose. Image assessment was done with measured Modulation Transfer Function, Peak Signal to Noise Ratio, Root Mean Square, Signal to Noise Ratio, Contrast to Noise Ratio, Mean to Standard deviation Ratio respectively. In exposure assessment results, selection of two upper chambers was the lowest. In resolution assessment results, image of two upper chambers had the second high spatial frequency at sensitivity at 625(High) was 1.343 lp/mm. RMS value of image selecting two upper chambers was low secondly. SNR, CNR, MSR were the high value secondly. As the sensitivity was increased, radiation dose was decreased but better image could be obtained on image quality. In order to obtain the best medical images while minimizing the dose, usage of two upper ion chambers is considered to be clinically useful at sensitivity 625(High).

Improving Usage of the Korea Meteorological Administration's Digital Forecasts in Agriculture: Correction Method for Daytime Hourly Air Temperature over Complex Terrain (기상청 동네예보의 영농활용도 증진을 위한 방안: 복잡지형의 낮 기온 상세화 기법)

  • Yun, Eun-jeong;Kim, Soo-ock
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.21 no.4
    • /
    • pp.221-228
    • /
    • 2019
  • The effects of wind speed on the temperature change during day time could be insignificant in a region with a complex terrain. The objective of this study was to derive empirical relationship between solar radiation and hourly temperature under a windy condition for the period from sunrise to sunset in order to improve hourly air temperature at a site-specific scale. The deviation of the temperature measurements was analyzed along with the changes of the hourly sunlight at weather observation sites located on the east and west slopes under given wind speed. An empirical model where wind speed use used as an independent variable was obtained to quantify the solar effects on the temperature change (MJ/㎡). This model was verified estimating the hourly temperature during the daytime (0600-1900 h) at 25 weather observation sites located in the study area that has complex topography for the period from January to December 2018. The mean error (ME) and root mean square error (RMSE)of the estimated and measured values ranged from -0.98 to 0.67 ℃, and from 0.95 to 2.04 ℃, respectively. The daytime temperature at 1500 h were estimated using new and previous models. It was found that to the model proposed in the present study reduced the measurement errors of the hourly temperature in the afternoon in comparison with the previous model. For example, the ME and RMSE of the previous model were (ME -0.91 ℃ and 1.47 ℃, respectively. In contrast, the values of ME and RMSE were -0.45 ℃ and 1.22 ℃ for the new model, respectively. Our results suggested that the reliability of hourly temperature estimates at a specific site could be improved taking into account the effect of wind as well as solar radiation.