Measurement of Bremsstrahlung Radiation with Electron Beam Energy

  • Srivastava, R.P.;Chaurasia, P.P.;Prasiko, G.;Jha, A.K.
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.235-236
    • /
    • 2002
  • A Klystron powered dual photon energy electron linear accelerator 2300 C/D from Varian Associates has been installed in our center. From the radiological safety view as well as treatment planning, the output (contamination) of Bremsstrahlung Radiation with electron beam energy determined accurately. It has been found 0.5% to 4.7% with increasing the electron beam energy which is the clinically not much significant in the treatment of the malignant diseases with the treatment of electron beam.

  • PDF

한반도에서 해상도 변화에 따른 지표면 일사량의 시공간 분포 (Temporal and Spatial Distributions of the Surface Solar Radiation by Spatial Resolutions on Korea Peninsula)

  • 이규태;조일성;지준범;최영진
    • 신재생에너지
    • /
    • 제7권1호
    • /
    • pp.22-28
    • /
    • 2011
  • The surface solar radiations were calculated and analyzed with spatial resolutions (4 km and 1 km) using by GWNU (Gangneung-Wonju National University) solar radiation model. The GWNU solar radiation model is used various data such as aerosol optical thickness, ozone amount, total precipitable water and cloud factor are retrieved from Moderate Resolution Imaging Spectrometer (MODIS), Ozone Monitoring Instrument (OMI), MTSAT-1R satellite data and output of the Regional Data Assimilation Prediction System(RDAPS) model by Korea Meteorological Administration (KMA), respectively. The differences of spatial resolutions were analyzed with input data (especially, cloud factor from MTSAT-1R satellite). And the Maximum solar radiation by GWNU model were found in Andong, Daegu and Jinju regions and these results were corresponded with the MTSAT-1R cloud factor.

접수 원통형 구조물의 표면 진동속도를 이용한 총 방사음향파워 계산 (Estimation of Total Acoustic Radiation Power of Submerged Circular Cylindrical Structure Using Surface Vibration Velocity)

  • 한승진;이종주;강명환;배수룡;정우진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.236-239
    • /
    • 2014
  • Most naval underwater weapon system can be simplified to a circular cylindrical structure which has vibrating machineries inside. In order to predict efficiently the total acoustic radiation power of cylindrical structure, surface velocity is measured and radiation efficiency of surface element is calculated. Then, they are substituted to the surface pressure in the simplified Helmholtz integral equation which assumes acoustic far-field and plane-wave approximation at the surface. Surface velocity and total acoustic radiation power for a submerged cylinder are measured in water-tank. In this example, it is found that total acoustic power output obtained from the prediction is in good agreement with that of measurement in mid-high frequency range.

  • PDF

전자소자의 과도방사선피해 평가체계 구축 연구 (A Study on Implementation of Transient Radiation Effects on Electronics(TREE) Assessment System)

  • 이남호;황영관;김종열;정상훈;오승찬
    • 한국정보통신학회논문지
    • /
    • 제16권10호
    • /
    • pp.2329-2334
    • /
    • 2012
  • 본 논문에서는 초기 핵 펄스방사선에 대한 군 무기체계내의 반도체 소자에 대한 피해를 분석하기 위해 피해평가 모델개발 연구를 수행하였다. 우선 핵 펄스방사선을 입력신호로 모델링하고 물성과 구조특성에 따라 정밀하게 모델로 구현한 다이오드 소자에 인가하여 소자내부에서 생성되는 전하들의 거동을 모사하고 출력특성을 분석하였다. 구축한 펄스방사선 피해 평가모델의 신뢰성 검증을 위해서 모델링한 소자와 동일한 공정변수로 제작한 다이오드 소자에 대해 유사한 특성의 펄스 방사선을 조사하고 출력전압의 순간 변화량을 실측하는 실험을 진행하였다. 실험결과 얻은 실측값은 동일소자의 모델에 대한 입력 펄스방사선의 출력 시뮬레이션 결과와 22.9%의 오차를 보여 개발한 피해평가 모델을 통해 핵 펄스방사선의 전자소자 피해현상을 비교적 정확히 모사하고 있음을 확인할 수 있었다.

CsI(T1) 방사선센서의 제작 및 분광특성 연구 (A Study on the Fabrication of CsI(T1) Radiation Sensor and its Spectroscopic Characteristics)

  • 권수일;신동호
    • 한국의학물리학회지:의학물리
    • /
    • 제13권1호
    • /
    • pp.44-50
    • /
    • 2002
  • 실험실에서 성장시킨 CsI(T1)섬광체를 이용하여 검출기를 설계 제작하고 분광 및 출력특성을 조사하여 핵분광과 진단방사선센서로서의 응용가능성을 타진해 보았다. CsI(T1)단결정은 수직 Bridgman성장장치를 이용하여 지름 11mm, 몰농도 0.001mo1%로 성장시키었다. 이 단결정을 광다이오드를 이용하여 방사선 센서로 제작한 후, $^{22}$ Na, /up 137/Cs, $^{30}$ Co 표준감마선원에 대한 에너지 분해능을 각각 측정하였으며 진단 X선 영역에 대한 출력특성도 측정하였다. $^{22}$ Na의 0.511 MeV 의 경우13.2%, $^{137}$Cs의 0.662 MeV의 경우 8.3%, 그리고 $^{60}$Co의 1.17 MeV와 1.332 MeV에 대해서는 각각 6.7%와 5.1%의 에너지 분해능을 얻었다. 또한 관전압 60kVp, 80kVp, 100kVp, 120kVp 에 대하여 5mAs부터 80mAs 까지 진단 X선영역에 대한 출력 선형성을 확인하였다.

  • PDF

Comparison of Temperature Distribution in Agar Phantom and Gel Bolus Phantom by Radiofrequency Hyperthermia

  • Jung, Dong Kyung;Kim, Sung Kyu;Lee, Joon Ha;Youn, Sang Mo;Kim, Hyung Dong;Oh, Se An;Park, Jae Won;Yea, Ji Won
    • 한국의학물리학회지:의학물리
    • /
    • 제27권4호
    • /
    • pp.224-231
    • /
    • 2016
  • The usefulness of Gel Bolus phantom was investigated by comparing the temperature distribution characteristic of the agar phantom produced to investigate the dose distribution characteristic of radiofrequency hyperthermia device with that of the Gel Bolus phantom under conditions similar to those of an agar phantom that can continuously carry out temperature measurement. The temperatures of the agar phantom and the Gel Bolus phantom were raised to $36.5{\pm}3^{\circ}C$ and a temperature sensing was inserted at depths of 5, 10, and 15 cm from the phantom central axis. The temperature increase rate and the coefficient of determination were analyzed while applying output powers of 100 W and 150 W, respectively, at intervals of 1 min for 60 min under conditions where the indoor temperature was in the range $24.5{\sim}27.5^{\circ}C$, humidity was 35~40%, internal cooling temperature of the electrode was $20^{\circ}C$, size of the upper electrode was 250 mm, and the size of the lower electrode was 250 mm. The coefficients of determination of 150 W output power at the depth point of 5 cm from the central axis of the phantom were analyzed to be 0.9946 and 0.9926 in the agar and Gel Bolus phantoms, respectively; moreover, the temperature change equation of the agar and Gel Bolus phantoms with time can be expressed as follows in the state the phantom temperature is raised to $36^{\circ}C:Y(G)$ is equation of Gel Bolus phantoms (in 5 cm depth) applying output power of 150 W. Y(G)=0.157X+36. It can be seen that if the temperature is measured in this case, the Gel Bolus phantom value can be converted to the measured value of the agar phantom. As a result of comparing the temperature distribution characteristics of the agar phantom of a human-body-equivalent material with those of the Gel Bolus phantom that can be continuously used, the usefulness of Gel Bolus phantom was exhibited.

일일 정도관리를 위한 Daily Check Device의 제작 및 효율성 평가 (Manufacture of Daily Check Device and Efficiency Evaluation for Daily Q.A)

  • 김찬용;제영완;박흥득;이제희
    • 대한방사선치료학회지
    • /
    • 제17권2호
    • /
    • pp.105-111
    • /
    • 2005
  • 목 적 : 방사선 치료의 성적 향상과 안정성, 정확성을 위해 시행되고 있는 정도관리는 치료과정의 오류를 사전 점검하기 위해 무엇보다 우선되어야 할 항목이다. 최근 방사선 치료기술이 3차원적으로 다양화되면서 정도관리의 중요성이 증대되고 있으며, 일일 정도관리 시 업무능률 향상을 위하며 체계적이고 신속한 방법이 요구되었다. 이에 본원에서는 일일 점검항목을 동시에 확인할 수 있는 Device를 자체 제작하여 그 효율성을 평가해 보고자 한다. 대상 및 방법 : 출력선량, laser alignment, field size, SSD indicator 점검을 한 번의 set up으로 시행할 수 있도록 device의 전면중앙 아크릴판 (가로 $30{\times}$ 세로 $30cm^2$)의 2 cm 깊이에 반도체 검출기를 삽입하였다. 상단에 $10{\times}10,\;20{\times}20cm^2$의 정방형 표시를 하여 field size를 확인할 수 있게 하였으며, 좌우 측면에 수직교차선이 표시되어있는 $30{\times}20cm^2$의 아크릴판을 부착하였다. 본 device를 4개월(2005. $2{\sim}5$월) 동안 본원에 설치되어 있는 4대의 선형가속기 일일 정도 관리에 사용하여 오차 점검의 편리성과 업무의 효율성에 관해 적용해 보았다. 결 과 : 측정과정이 간편하고 소요시간이 5분 정도로 기존($10{\sim}15$분)보다 단축되어 일일점검의 효율성이 향상되었고, 출력선량측정은 각 Energy별로 ${\pm}2%$이내였으며, laser, field size, SSD indicator는 ${\pm}1mm$이내의 범위에서 측정되었다. 결 론 : 일일 점검의 소요시간 단축으로 인하며 업무능률이 향상되었고 일일 정도관리 기록을 바탕으로 월간, 연간 정도 관리 기초 자료로써의 활용이 가능하였다. 또한 제작된 Daliy Check Device는 상품화된 고가의 측정 장비를 대체함으로써 비용절감 효과를 얻을 수 있었으며, 사용자의 편의 개선을 위한 장치 재질의 견고성 및 가벼운 소재의 개발이 필요할 것으로 사료된다.

  • PDF

확장된 SSD에 기인한 Electron beam의 Output 및 특성 변화에 관한 연구 (A Study on clinical Considerations caused by inevitably Extended SSD for Electron beam therapy)

  • 이정우;김정만
    • 대한방사선치료학회지
    • /
    • 제8권1호
    • /
    • pp.29-35
    • /
    • 1996
  • We are often faced with the clinical situations that is inevitably extended SSD for electron beam therapy due to anatomical restriction or applicator structure. But there are some difficulties in accurately predicting output and properties. In electron beam treatment , unlike photon beam the decrease in output for extended SSD does not follow inverse-square law accurately because of a loss of side scatter equilibrium, which is particularly significant for small cone size and low energies. The purpose of our study is to analyze the output in changing with the energy, cone size, air gap beyond the standard SSD and to compare inverse-square law factor derived from calculated effective SSD, mominal SSD with measured output factor. In addition, we have analyzed the change of PDD for several cones with different SSDs which range from 100cm to 120cm with 5cm step and with different energies(6MeV, 9MeV, 12MeV, 16MeV, 20MeV). In accordance with our study, an extended SSD produces a significant change in beam output, negligible change in depth dose which range from 100cm to 120cm SSDs. In order to deliver the more accurate dose to the neoplastic tissue, first of all we recommend inverse-square law using the table of effective SSDs with cone sizes and energies respectively or simply to create a table of extended SSD air gap correction factor. The second we need to have an insight into some change of dose distribution including PPD, penumbra caused by extended SSD for electron beam therapy.

  • PDF

60 GHz 대역 능동 안테나 모듈 설계 (Active Antenna Module for 60 GHz Frequency Band)

  • 안세인;윤상원
    • 한국전자파학회논문지
    • /
    • 제30권6호
    • /
    • pp.518-521
    • /
    • 2019
  • 본 논문에서는 상용 트랜스미터 칩과 패치 어레이 안테나를 결합하여 60 GHz 대역에서 동작하는 능동 안테나 모듈을 설계, 제작하였다. 설계된 모듈은 안테나 PCB와 트랜스미터 칩이 장착된 송신 모듈 PCB가 결합되는 구조로 하였다. 주파수 제어신호 및 바이어스 제어신호는 아두이노 키트를 사용하여 인가하였으며, 기저대역의 I/Q 신호가 트랜스미터 칩으로 인가될 수 있도록 하였다. 송신 모듈의 출력은 단일 출력으로 안테나에 연결되므로 차동 출력을 내는 트랜스미터 칩의 출력을 링 하이브리드 발룬에 전달하고, 이를 초소형 상용 커넥터로 $2{\times}4$ 마이크로스트립 패치 어레이 안테나 PCB로 전달되도록 하였다. 최종 출력되는 밀리미터파 신호의 방사패턴 측정을 통하여 시뮬레이션 결과와 비교하는 방식으로 확인하였다. 제작된 능동 안테나 모듈의 방사패턴 측정 결과, 3 dB 빔폭과 null 포인트의 위치가 시뮬레이션 결과와 잘 일치함을 확인하였다.

A Study on Radiation Risk Recognition Aided System Visualizing Risk Information by CG

  • Katagiri, M.;Tuzuki, Y.;Sawamura, S.;Aoki, Y.
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -1
    • /
    • pp.425-428
    • /
    • 2002
  • The technology of Computer Graphics (CG) has been in great progress for almost 20 years and has proven to be a valuable tool for a broad variety of fields, including nuclear engineering. To work in any hazardous environment for example radiation field is particularly challenging because the danger is not always visually apparent. In this study as the application of CG to nuclear engineering field, we proposed to develop a radiation risk recognition aided system in which various radiation information; radiation risks, radiation distribution, hazard information and so on, were visualized by CG. The system used the server and client system. In the server there were two parts; one (main-server) was the database part having various data and the other (sub-server) was the visualization part visualizing the human phantom by POV-Ray. In the client there was the input and output part. The outputs from the system were various radiation information represented by coloring, circle graph and line graph intuitionally. The system is useful for a broad range of activities including radiation protection, radiation management, dose minimization, and demonstration to the public.

  • PDF