형광유리 선량계와 광자극 발광선량계를 이용한 핵의학과 선량 측정비교 (Comparison on the Dosimetry of OSLD and PLD Used in Nuclear Medicine)

  • 박정규;손상준;박명환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권1호
    • /
    • pp.47-51
    • /
    • 2019
  • This study was conducted from July 1 to September 30, 2018 using Optically Stimulated Luminescence Dosimeter(OSLD) and photoluminescent glass dosimeter(PLD) to measure the 3-month exposure dose and the cumulative dose in the active working area of the nuclear medicine worker Respectively. As a result, the cumulative dose for three months in the worker and work area was measured as 1.97 mSv and 2.02 mSv in the PLD. The mean surface dose and the mean depth dose of the OSLD were measured to be 2.04 mSv. The difference in the total surface dose measured by the PLD and the OSLD was 0.66mSv and the total mean surface dose was 0.07mSv. The difference between the total depth dose and the total depth dose was 0.1mSv and 0.02mSv, respectively. It was found that the dose value of the OSLD was higher than that of the PLD. In addition, it was found that the maximum difference of 0.01mSv was observed between the PLD and the OSLD of the worker. For the dose measurement of the two dosimetry systems, there was no significant difference between the PLD and the OSLD in the surface dose of 0.239 (p>0.05). Also, the significance of PLD and OSLD in the deep dose was 0.109, which was not statistically significant (p>0.05).

Brain CT검사 시 3D프린터 필라멘트에 따른 수정체 차폐 연구 (A Study on the Shielding of Orbit by 3D Printed Filament in Brain CT)

  • 최우전;김동현
    • 한국방사선학회논문지
    • /
    • 제15권2호
    • /
    • pp.101-108
    • /
    • 2021
  • CT는 인체 내 장기의 해부학적 구조를 정확하게 나타낼 수 있으며, 영상의 분해능이 우수하다. Brain CT 검사 시 수정체의 방사선 감수성이 높아서 피폭의 영향을 많이 받는다. 본 연구는 수정체에 피폭선량을 감소하기 위해 비스무스와 텅스텐 필라멘트 차폐물질을 사용하여 Non-shield와 Shield에 대한 피폭선량의 변화와 차폐율을 비교 하고자 한다. 본 연구에서는 3D printing으로 제작한 비스무스, 텅스텐 필라멘트 차폐물질을 사용하여, 차폐물질 두께와 slice에 따라 피폭되는 선량을 측정하였다. 헤드팬텀을 고정시켜 안구에 Magicmax universal 선량계를 위치시켜 차폐 물질을 놓지 않았을 경우와 그 위에 차폐 물질을 놓았을 때 차폐율을 각각 비교하기 위해 두 물질을 1mm ~ 5mm 두께로 각각 측정하였다. 1 mm 두께의 필라멘트에서 비스무스 필라멘트는 26.8 %, 텅스텐 필라멘트는 43.1 % 차폐율이 나타났다. 따라서 비스무스 필라멘트보다 텅스텐 필라멘트에서 더 큰 차폐효과가 나타났다. 차폐체의 종류, 두께, 슬라이스 간격에 따라 선량을 측정한 결과, 비스무스 필라멘트 보다 텅스텐 필라멘트가 더 큰 차폐효과가 나타났다.

중적외선 센서 위성 영상의 상온 온도 정보 추출 가능성 및 정확도 (Possibility and Accuracy of Extracting Room Temperature Information from Mid-Infrared Sensor Satellite Images)

  • 최석원;서두천;이동한
    • 우주기술과 응용
    • /
    • 제1권3호
    • /
    • pp.356-363
    • /
    • 2021
  • 중적외선을 이용하여 획득한 영상은 상온 부근의 온도 측정에는 적당하지 않다는 것이 교과서적 상식이었으나, 최근 중적외선 센서를 이용한 위성 영상을 살펴보면 중적외선 센서를 이용하여 측정한 결과물도 상온 부근의 온도를 측정할 수 있다는 가능성을 보여주고 있다. 본 논문에서는 중적외선 센서를 가지는 위성영상의 상온 온도 정보 추출 가능성 및 정확도에 대해 살펴보고자 한다. 논문에서 검토된 중적외선 위성영상은 상온 부분의 온도를 잘 표시하였으며, 측정된 온도의 절대값으로서의 신뢰성에 관해서는, 태양광의 지표면 직접 반사에 의한 열전달량 영향과 대기에서 흡수되는 적외선 대기 흡수량의 영향은 비교적 작거나 일정한 값으로 볼 수 있지만, 비접촉식 온도계의 한계인 물성치의 의한 복사 계수(emissivity)의 불확실성 문제는 여전히 해결해야할 문제로 남아 있게 되었다.

체적골밀도 측정법 동향: 수술부위 골밀도 분석 (Volumetric Bone Mineral Density Measurement: for Surgery Specific Bone Volumes)

  • 이연수
    • 한국방사선학회논문지
    • /
    • 제16권1호
    • /
    • pp.53-59
    • /
    • 2022
  • CT영상을 기반으로 한 QCT는 CT장비와 컴퓨터영상처리기술의 발전과 함께 적은 방사선 투과양으로도 체적골밀도를 측정할 수 있는 방향으로 크게 발전하고 있다. 방사선 의료영상을 대표적인 골밀도 측정법인 이중방사선흡수계수법(DXA)은 척추나 근위대퇴골과 다른 뼈와의 상관성이 떨어지는 경우가 많고질량효과에 의한 부정확성의 근본 원인을 가지고 있기 때문에 체적골밀도측정법인 단일에너지CT영상을 이용한 QCT법이 가장 보편적인 정확한 골밀도 측정법이다. 이중에너지CT의 사용은 단단한 뼈와 동시에 종양이나 연부조직의 이상을 같이 볼 수 있는 영상을 얻을 수 있게 되어 QCT 골밀도와 함께 특정연부조직이나 장기를 검사할 수 있어 그 사용이 더욱 늘어날 것으로 예상된다. 임상수술이나 추적검사가 필요한 위치에 사용자가 해부학적으로 특정한 형상체적에 대한 국부골밀도측정 방법도 병원의 임상현장에서 활용할 기술로 대두되고 있다.

Preliminary Study on Natural Killer Cell Activity for Interfer-on-Gamma Production after Gamma Knife Radiosurgery for Brain Tumors

  • Park, Kawngwoo;Jeong, Sang Soon;Kim, Jung Hoon;Chung, Hyun-Tai;Lee, Eun Jung;Moon, Hyo Eun;Park, Kwang Hyon;Kim, Jin Wook;Park, Hye Ran;Lee, Jae Meen;Lee, Hye Ja;Kim, Hye Rim;Cho, Yong Hwan;Paek, Sun Ha
    • Journal of Korean Neurosurgical Society
    • /
    • 제65권6호
    • /
    • pp.861-867
    • /
    • 2022
  • Objective : High-dose radiation is well known to induce and modulate the immune system. This study was performed to evaluate the correlation between clinical outcomes and changes in natural killer cell activity (NKA) after Gamma Knife Radiosurgery (GKS) in patients with brain cancer. Methods : We performed an open-label, prospective, cross-sectional study of 38 patients who were treated with GKS for brain tumors, including metastatic and benign brain tumors. All of the patients underwent GKS, and blood samples were collected before and after GKS. NKA was measured using an enzyme-linked immunosorbent assay kit, to measure interferon-gamma (IFNγ) secreted by ex vivo-stimulated NK cells from whole blood. We explored the correlations between NK cell-produced IFNγ (NKA-IFNγ) levels and clinical parameters of patients who were treated with GKS for brain tumors. Results : NKA-IFNγ levels were decreased in metastatic brain tumor patients compared to those with benign brain tumors (p<0.0001). All the patients who used steroid treatment to reduce brain swelling after GKS had an NKA-IFNγ level of zero except one patient. High NKA-IFNγ levels were not associated with a rapid decrease in brain metastasis and did not increase after GKS. Conclusion : The activity of NK cells in metastatic brain tumors decreased more than that in benign brain tumors after GKS.

DEA-Malmquist 지수를 이용한 중국 환경효율에 관한 평가 연구 (Research on Eco-efficiently Evaluation of China Based on DEA-Malmquist Index)

  • YULIN, LU;YAN, HE
    • 디지털융복합연구
    • /
    • 제20권5호
    • /
    • pp.375-381
    • /
    • 2022
  • 본 연구는 중국 30개 성시를 연구 대상으로 하여 정태적, 동태적 두 가지 각도에서 연구의 시발점으로 하였으며, DEA-BCC 모델과 Malmquist 지수를 사용하여 2011~2020년 중국 30개 성시의 환경 효율성을 산정하였다. 연구에 따르면 중국 30개 성시의 정태 환경 효율성은 평균 0.643으로 전국 범위에서 뚜렷한 차이를 보인다. Beijing, Shanghai는 환경 효율성이 유효하고 나머지 28개 성시는 모두 차원이 다른 비효율 상태를 가지고 있다. 구역발전에서도 차별성이 있어 전반적으로 동고서저형 공간 구도를 보인다. 전국 30개 성시의 환경 효율성인 Malmquist 지수는 상승하는 성장세를 보이며 기술진보가 주요한 추진력이 된다. 향후 정책에서는 동부지역의 방사선 견인능력을 높이고 각 구역 간 시너지를 강화하여 구역 우위를 충분히 발휘해야 할 것이다. 그리고 산업구조 최적화, 과학기술 수준 제고, 전국 환경 효율성의 상승을 견인하여 녹색 발전을 실현한다.

뇌혈관 직경측정을 위한 3차원 회전 혈관조영술의 유용성 (Usefulness of 3D Rotational Angiography for Cerebral Vascular Diameter Measurement)

  • 김승기;김상현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권1호
    • /
    • pp.9-14
    • /
    • 2023
  • When measuring cerebrovascular with 3D rotational angiography, the accuracy was verified by comparing the actual size and measurement size, respectively. It is intended to help select therapeutic materials and instruments during cerebrovascular intervention by comparing the average error rates for measured values in the 3DRA and CTA methods by examining with protocols such as brain CTA, which are always performed in emergency situations. The mean error rate between the groups of measurers was ±3.655% for radiation technologist and ±3.331% for university students, and the mean error rate of the student group was within tolerance (±10%), and the independent sample T-test result t =0.879, p=0.394 (p>0.05) showed no statistically difference between the two. In addition, the average error rate measured by both groups by 3DRA was measured below ±5% within the tolerance error rate (±10%), and most of CTA was measured within the tolerance range (±10%), but showed an average error rate of up to 5.65%, and the independent sample T-test result was statistically more accurate than 3DRA. Both the 3DRA method and the brain CTA method for measuring cerebrovascular size could be accurately measured within tolerance, but it would be better to measure cerebrovascular blood vessels using a more accurate 3DRA method during cerebrovascular intervention.

2022년 발생한 기록적인 유럽 폭염 발생의 역학적 원인 규명 연구 (Understanding Physical Mechanism of 2022 European Heat Wave)

  • 김주헌;양군환;성현준;박정현;서은교
    • 대기
    • /
    • 제33권3호
    • /
    • pp.307-317
    • /
    • 2023
  • This study investigates the physical mechanisms that contributed to the 2022 European record-breaking heatwave throughout May-August (MJJA). The European climate has experienced surface warming and drying in the recent decade (1979~2022) which influences the development of the 2022 European heatwave. Since its spatial pattern resembles the 2003 European heatwave which is a well-known case developed by the strong coupling of near-surface conditions to land surface processes, the 2022 heatwave is compared with the 2003 case. Understanding heatwave development is carried out by the European Centre for Medium-Range Weather Forecasts (ECMWF) Reanalysis version 5 (ERA5) and daily maximum surface temperature released by NCEP (National Centers for Environmental Prediction) CPC (Climate Prediction Center). The results suggest that the persistent high pressure along with clear sky tends to increase the downward shortwave radiation which leads to enhanced sensible heat flux with the land surface dryness. Terrestrial Coupling Index (TCI), a process-based multivariate metric, is employed to quantitatively measure segmented feedback processes, separately for the land, atmosphere, and two-legged couplings, which appears to the development of the 2022 heatwave, can be viewed as an expression of the recent trends, amplified by internal land-atmosphere interactions.

PET-CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구 (A Study of Decrease Exposure Dose for the Radiotechnologist in PET/CT)

  • 김빛나;조석원;이주영;유광열;박훈희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권1호
    • /
    • pp.23-30
    • /
    • 2015
  • 양전자 방출핵종은 511 keV의 감마선을 방출하기 때문에 기존 140 keV의 99mTc에 비해 종사자의 방사선 피폭의 증가로 피폭선량 저감을 위한 노력이 요구된다. 본 연구는 환자에게로부터 일정거리에 따른 선량률 변화를 확인하고 차폐를 이용하여 외부선량률의 변화를 알아보았으며 환자 주변의 외부선량 분포에 대한 영 향을 분석하여 방사선 종사자의 피폭 관리에 도움이 되고자 하였다. 10 명의 환자를 대상으로 하였으며 평균연령은 $47.7{\pm}6.6$ 세였다. 환자의 키는 평균 $165.5{\pm}3.8cm$, 몸 무게 평균은 $65.9{\pm}1.4kg$으로 비슷한 몸무게의 환자를 대상으로 하였다. 머리, 가슴, 복부, 무릎, 발끝 쪽의 위치에서 10 cm, 50 cm, 100 cm, 150 cm, 200 cm 위치에서 측정하였고 측정 후에 즉시 이동형 방사선 차폐체을 설치한 후 머리와 가슴, 복부 부분에서 100 cm, 150 cm, 200 cm 거리에서 선량률을 측정하였다. 거리에 따른 선량률 변화와 차폐 전, 후의 투과율을 구하였다. 평균 10 cm 거리에서는 머리 부분이 $105.40{\mu}Sv/h$로 가장 높게 나타났으며 발 부분에서 $15.85{\mu}Sv/h$로 가장 낮게 나타났다. 200 cm 거리에서는 머리, 가슴, 복부 부분에서 비슷한 선량률이 나타났다. 머리 부분에 서 차폐 전 100 cm에서 $9.56{\mu}Sv/h$, 150 cm에서 $5.23{\mu}Sv/h$, 200 cm에서 $3.40{\mu}Sv/h$로 나타났으며 차폐 후에는 100 cm, 150 cm, 200 cm 에서 각각 $2.24{\mu}Sv/h$, $1.67{\mu}Sv/h$, $1.27{\mu}Sv/h$로 측정되었다. 가슴 부분에 서 차폐 전 100 cm에서 $8.54{\mu}Sv/h$, 150 cm에서 $4.90{\mu}Sv/h$, 200 cm에서 $3.44{\mu}Sv/h$로 나타났으며 차폐 후에는 100 cm, 150 cm, 200 cm 에서 각각 $2.27{\mu}Sv/h$, $1.34{\mu}Sv/h$, $1.13{\mu}Sv/h$로 측정되었다. 복부 부분에 서 차폐 전 100 cm에서 $9.83{\mu}Sv/h$, 150 cm에서 $5.15{\mu}Sv/h$, 200 cm에서 $3.18{\mu}Sv/h$로 나타났으며 차폐 후에는 100 cm, 150 cm, 200 cm 에서 각각 $2.60{\mu}Sv/h$, $1.75{\mu}Sv/h$, $1.23{\mu}Sv/h$로 측정되었다. 투과율은 거리에 따라 증가함을 알 수 있었다. 거리가 멀어질수록 선량율이 낮아지는 것을 확인할 수 있었으며 차폐를 하였을 경우 차폐를 하지 않았을 때보다 1 / 4 정도 더 낮아지는 것을 확인할 수 있었다. 검사를 진행하는 근무자는 환자와의 거리를 멀리 할 수 없기 때문에 방사선 피폭이 증가할 수밖에 없다. 따라서 적절한 차폐를 한다면 방사선 종사자의 방사선 피폭을 줄 일 수 있을 것이다.

PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구 (A Study to Decrease Exposure Dose for the Radiotechnologist in PET/CT)

  • 조석원;박훈희;김정열;반영각;임한상;오기백;김재삼;이창호
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.159-165
    • /
    • 2010
  • 방사선 분야는 건강검진의 증가와 방사선 장치의 발달로 진단에서 치료까지 그 업무의 범위가 확대 및 급격히 증가하고 있으며 방사선 종사자의 방사선 피폭 관리가 중요하게 대두되고 있다. PET 검사에 이용되는 양전자 방출핵종은 511 keV의 감마선을 방출하기 때문에 종사자의 방사선 피폭의 증가로 피폭선량 저감을 위한 노력이 요구된다. 본 연구는 환자에게로부터 일정거리 외부선량률을 측정하고 거리에 따른 선량률 변화를 확인하고 차폐를 이용하여 외부선량률의 변화를 알아보았다. 2009년 12월부터 2010년 1월까지 PET/CT 검사를 위해 내원한 10명의 환자를 대상으로 하였다. Digital surveymeter를 이용하여 선량률을 측정하였다. 산란선에 대한 영향을 평가하기 위해서 이동식 방사선 차폐체를 설치하고 왼쪽, 중앙, 오른쪽 부분의 100 cm, 150 cm, 200 cm에서 총 12회 선량률을 측정하였다. 환자 선량률 측정은 $^{18}F$-FDG 5.18 MBq/kg을 주사하고 1시간이 지난 후에 선량이 안정되었을 때 즉시 1회를 측정하였다. 이동식 방사선 차폐체를 설치하기 전에 머리, 가슴, 복부, 무릎, 발끝 쪽의 위치에서 10 cm, 50 cm, 100 cm, 150 cm, 200 cm 위치로 총 80포인트에서 측정하였고 이동형 방사선 차폐체를 설치한 후 머리와 가슴, 복부 부분에서 100 cm, 150 cm, 200 cm 거리의 선량률을 측정하여 외부선량률을 확인하였다. 산란선 측정에 대해서는 위치별로 거리에 따라 분산분석을 시행하였다. 납 차폐를 하지 않았을 때와 차폐를 했을 때의 등선량곡선을 그렸으며 100 cm, 150 cm, 200 cm에 대하여 두 집단간에 상관분석을 시행하였다(SPSS ver. 12). 점 선원을 이용한 산란선 측정에서 100 cm, 150 cm, 200 cm에서는 p>0.05로 유의한 차이가 없었다. 거리가 멀어질수록 선량률이 낮아졌으며 머리 부분이 가장 높은 선량률이 나타났고 발 부분으로 갈수록 선량률이 떨어졌다. 또한 차폐를 하였을 경우 차폐를 하지 않았을 때보다 선량률이 낮아졌으며 100 cm에서 유의한 차이가 있었고(p<0.05) 150 cm, 200 cm에서는 유의한 차이가 없었다(p>0.05). 피폭을 줄이기 위해서는 방사선원에서 거리를 멀리하거나 적당한 차폐체를 이용하는 것이 피폭저감에 도움을 준다. 근무자의 동선을 파악하여 적당한 차폐체를 이용한다면 방사선 종사자의 방사선 피폭을 줄일 수 있을 것이다.