• Title/Summary/Keyword: Radiation Measure

Search Result 808, Processing Time 0.022 seconds

Radionuclides in Environmental Samples and Sample Concentration of Land in the Analysis in the Method of Direct (직접법에서 환경시료중 육상시료의 방사성 핵종 및 농도 분석)

  • Jang, Eun-Sung;Kim, Jin-Seop
    • Journal of Environmental Science International
    • /
    • v.24 no.3
    • /
    • pp.275-280
    • /
    • 2015
  • In order to measure the Radionuclides and Concentration, the directly grinded land samples (river soil, pine leaves and mugwort) among the environment samples around the nuclear power plant were filled in a 450 mL Marinelli beaker and weighed to obtain the dry mass ratio of the samples. Then the background and land samples were measured for 80,000 sec. The analysis of the collected land samples showed that most of them contained less radiation nuclide than the detection minimum limit in the 'Ministry of Education, Science and Technology Public Notice No. 2010-32.'In others, the natural radionuclides $^{40}K$ were detected. Of the products of nuclear reaction discharged by a nuclear reaction, $^{134}Cs$ and $^{137}Cs$ are more easily detected, and their discharge sources can be traced using the relative ratio. Although the radioactive concentration in the vicinity of Kori Nuclear Power Plant, which is more than 1,100km away from Fukushima, the Japanese nuclear accident site, continuous monitoring is needed as the radionuclides can still be accumulated in the soil or animals and plants.

The centroid shift of Sgr A*

  • Cho, Il-Je;Sohn, Bong Won;Jung, Taehyun;Kino, Motoki;Zhao, Guang-Yao;Agudo, Ivan;Rioja, Maria;Dodson, Richard
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.41.1-41.1
    • /
    • 2016
  • The Galactic center, Sagittarius A* (Sgr A*), is the closest supermassive black hole and emits synchrotron radiation. It provides great opportunity to study the origin of mm/sub-mm emission. Currently, two competing models have been suggested as a jet base and a radiatively inecient accretion flow (RIAF). To unveil the properties, the extremely high resolution(${\sim}10{\mu}as$) corresponding to the projected Schwarzschild radius of ~0.1AU is necessary. With KVN, a jet model can be tested by multi- frequency simultaneous observations because the optically thick surface in a jet (i.e. radio core) moves toward the center at a higher frequency. We conducted 8 observations with KVN at 43/86GHz in 2015, and found that the measured positional shift to the reference calibrator, J1744-3116, was ~0.3 mas to the south of Sgr A* using the source frequency phase referencing (SFPR) at Q/W bands for the first time. With the result, in the future, we will attempt to measure the variation of source position shifts that can constrain the direction of approaching jets and the variability of black hole activity of Sgr A*.

  • PDF

Measurement of Electrophysiological Changes Caused by Electromagnetic Radiation Absorbed in Biobody (전자파에 노출된 생체의 전기 생리적 변화의 측정)

  • Ju-Tae Park
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.7 no.4
    • /
    • pp.353-362
    • /
    • 1996
  • In this paper, SAR distribution is calculated according to the rabbit's head using approximation of its medium three layers model. Our experiment was classified 5 groups dependent on the power intensity of 2,450MHz microwave to measure EEG(Electroencephalograph) of rabbit, which was checked in left frontal lobe before and after irradiation of microwave. In results, mean total power of EEG was slightly decreased and mean composition percentages of $\theta$, $\delta$ and $\beta$ wave were increased after irradiation in observation. It means to decrease of elect- rophysiologic activity and trend of fast wave in brain after irradiation of its microwave. We analyzed the electrophysiological effect of the biobody quantitatively using measured EEG and estimated MPE (Maximum Permissible Exposure).

  • PDF

Design of Filter for Output Signals in Incremental Encoder for Detecting Speed and Position of Motors (전동기 속도 및 위치검출용 증분형 엔코더 출력신호 필터 설계)

  • Ahn Jung-Ryol;Lee Hong-Hee;Kim Heung-Gun;Nho Eui-Cheol;Chun Tae-Won
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.290-295
    • /
    • 2005
  • The incremental encoder has been mostly used to measure the speed and position of the motor. As the output signals of encoder are high frequency digital signals, they have much influence on radiation noises due to switching of the power semiconductor circuits. It is so difficult to suppress the noises with the conventional LPF. In this paper, the hardware digital filter for suppressing noises in the output signals of the encoder signals is developed. As both the clock frequency and counter in the digital filter for encoder are easily adjusted according to the kinds of noises, any noises in the encoder can be entirely eliminated. The performance of the digital filter has been verified by simulation and experimental results.

Charge Accumulation in Glass under E-beam irradiation (E-beam 조사하에서 유리의 전하 측정)

  • Kim, Dae-Yeol;Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.268-269
    • /
    • 2008
  • Charging of spacecraft occurs in plasma and radiation environment. Especially, we focused on an accident caused by internal charging in a glass material that was used as the cover plate of solar panel array, and tried to measure the charge distribution in glass materials under electron beam irradiation by using a PEA (Pulsed Electro-Acoustic method) system. In the case of a quartz glass (pure $SiO_2$), no charge accumulation was observed either during or after the electron beam irradiation. On the contrary, positive charge accumulation was observed in glass samples containing metal-oxide components. It is found that the polarity of the observed charges depends on the contents of the impurities. To identify which impurity dominates the polarity of the accumulated charge, we measured charge distributions in several glass materials containing various metal-oxide components and calculated the trap energy depths from the charge decay characteristics of all glass samples.

  • PDF

DEVELOPMENT OF 2.8-GHZ SOLAR FLUX RECEIVERS

  • Yun, Youngjoo;Park, Yong-Sun;Kim, Chang-Hee;Lee, Bangwon;Kim, Jung-Hoon;Yoo, Saeho;Lee, Chul-Hwan;Han, Jinwook;Kim, Young Yun
    • Journal of The Korean Astronomical Society
    • /
    • v.47 no.6
    • /
    • pp.201-207
    • /
    • 2014
  • We report the development of solar flux receivers operating at 2.8 GHz to monitor solar radio activity. Radio waves from the sun are amplified, filtered, and then transmitted to a power meter sensor without frequency down-conversion. To measure solar flux, a calibration scheme is designed with a noise source, an ambient load, and a hot load at $100^{\circ}C$. The receiver is attached to a 1.8 m parabolic antenna in Icheon, owned by National Radio Research Agency, and observation is being conducted during day time on a daily basis. We compare the solar fluxes measured for last seven months with solar fluxes obtained by DRAO in Penticton, Canada, and by the Hiraiso solar observatory in Japan, and finally establish equations to convert observed flux to the so-called Penticton flux with an accuracy better than 3.2 sfu.

Prediction of the Radiated Noise from the Vehicle Intake System (자동차 흡기계의 방사소음 예측에 대한 연구)

  • Kim, Hoi-Jeon;Ih, Jeong-Guon;Lee, Seong-Hyun;Shinoda, K.;Kitahara, S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.105-108
    • /
    • 2005
  • The radiated noise from the automotive intake system should be predicted at the design stage. To this end, the precise measurement of in-duct acoustic source parameters of the intake system, i.e., the source strength and source impedance, is essential. Most of previous works on the measurement of acoustic source parameters were performed under a fixed engine speed condition. However, the requirement of vehicle manufacturer is the noise radiation pattern as a function of engine speed. In this study, the direct method was employed to measure the source parameters of engine intake system under a fixed engine speed and engine run-up condition. It was noted that the frequency spectra of source impedance hardly changes with varying the engine speed. Thus, it is reasonable to calculate the source strength under the engine run-up condition by assuming that source impedance is invariant with engine speed. Measured and conventional source models, i.e., constant pressure source, constant velocity source, and non-reflective source, were utilized to predict insertion loss and radiated sound pressure level. A reasonable prediction accuracy of radiated sound pressure level spectra from the intake system was given in the test vehicle when using the measured source characteristics which were acquired under the operating condition.

  • PDF

Noise Source Identification and Acoustic Radiation Power Reduction of Hard Disk Drive Using Sound Intensity (음향 인텐시티를 이용한 하드디스크 드라이브의 소음원 파악 및 음향파워 제어)

  • Kang, Seong-Woo;Han, Yun-Sik;Hwang, Tae-Yeon;Son, Young;Koo, Ja-Choon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1540-1548
    • /
    • 2000
  • Sound intensity techniques and ODS(Operational Deflection Shape) techniques are applied to identify the acoustic noise source of a hard disk drive and its control system. The sound intensity is used to visualize the noise source locations, and the ODS information to visualize the vibration pattern and to obtain the dynamic characteristics of the noise sources. The measurement systems are customized to accurately measure the sound intensity and ODS distributions of HDD system in space domains as well as frequency domains. The measurement systems for the sound absorption and transmission loss of materials are also used to support the background data for the efficient noise control. Using the visual information of source locations and its dynamic characteristics, the partial noise barrier structure and optimum absorption are designed and its controlled sound power level is proved to be under 3.1 Bel(Idle)/3.3Bel (Seek) which is the lowest level in the disk drive industry.

  • PDF

A Study on the System Development and Management Method of USN Plants for Monitoring of Natural Disasters and Radioactive Contamination (자연재해 및 방사능 오염 모니터링용 USN 식물공장관리방법 및 시스템 개발)

  • Joo, Hae-Jong;Cho, Moon-Taek;Lee, Chung-Sik;Baek, Jong-Mu
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.351-355
    • /
    • 2011
  • In this paper, monitoring system and platform of plant growth are suggested which are required by safe crop management about disaster and radiation pollution. In addition, by monitoring plant growth, the growth of plants that can measure the size of the efficient system was developed. The expected effect of this study, first, through natural disasters and radioactive contamination monitors produce fast and accurate response function can result in improved quality and productivity. Second, the size of the plant required to maintain the measurement data can save time and expense savings. Finally, plant managers can improve work efficiency.

Evaluation Absorbed Dose During the Breast Cancer Brachytherapy in Canine Phantom (반려견 팬텀에서 유방암 근접방사선치료 시 흡수선량 평가)

  • Kim, Jung-Hoon;Lee, Deuk-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.523-528
    • /
    • 2020
  • The application of breast cancer, which has the highest incidence in females among cancer that is the number one cause of death for dogs, was to be evaluated the absorbed dose during brachytherapy using simulation. MCNPX program was used for simulation, and a small size canine phantom was produced to measure absorbed dose. The results of the absorbed dose was the highest at 192Ir to 1.02E-12 Gy/# for tumors, and the same tendency was shown for internal and external absorbed dose. Therefore, the selection of appropriate sources for dog breast cancer should be considered in brachytherapy, taking into account dog breeds and exposures.