• 제목/요약/키워드: Radiation Limits

검색결과 174건 처리시간 0.032초

Sensitivity of GAGG based scintillation neutron detector with SiPM readout

  • Fedorov, A.;Gurinovich, V.;Guzov, V.;Dosovitskiy, G.;Korzhik, M.;Kozhemyakin, V.;Lopatik, A.;Kozlov, D.;Mechinsky, V.;Retivov, V.
    • Nuclear Engineering and Technology
    • /
    • 제52권10호
    • /
    • pp.2306-2312
    • /
    • 2020
  • Here we report on the first results of sensitivity evaluation of the gadolinium-aluminum-gallium- garnet (GAGG) scintillation detector with SiPM readout to fast and slow neutrons and, to the natural background and Co-60 γ-radiation as well. Data on sensitivity were obtained using certified dosimetry benches, so it can be utilized in the calculation of detection limits of neutron flux with such type of detectors. It was concluded that use of GAGG scintillator has a good prospect for neutron monitoring in different parts of nuclear research reactors and power plants.

Region-wise evaluation of gamma-ray exposure dose in decontamination operation after a nuclear accident

  • Jeong, Hae Sun;Hwang, Won Tae;Han, Moon Hee;Kim, Eun Han;Lee, Jo Eun;Lee, Cheol Woo
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2652-2660
    • /
    • 2021
  • The gamma-ray exposure doses in decontamination operation after a nuclear accident were evaluated with a consideration of various geometrical conditions and specific gamma-ray energies. The calculation domain is organized with three residence types and each form is divided into two kinds of geometrical arrangements. The position-wise air KERMA values were calculated with an assumption of evenly distributed gamma-ray source based on Monte Carlo radiation transport analysis using the MCNP code. The radioactivity is initially set to be unity to be multiplied by the deposition value measured in the actual accident condition. The workforce data set depending on the target object was determined by modifying the Fukushima report. The external exposure doses for decontamination workers were derived from the calculated KERMA values and the workforce analysis. These results can be used to efficiently determine the workforce required by the characteristics of the area and the structure to be decontaminated within the dose limits.

고온연료의 점화 및 화염 소화특성에 미치는 복사효과 (Radiation Effects on the Ignition and Flame Extinction of High-temperature Fuel)

  • 김유정;오창보;최병일;한용식
    • 한국화재소방학회논문지
    • /
    • 제27권6호
    • /
    • pp.50-56
    • /
    • 2013
  • 대향류 비예혼합 연료-공기 유동장에서 고온연료의 점화특성과 형성된 화염의 소화특성에 미치는 복사효과에 대해 수치계산을 통해 검토하였다. 화학반응의 계산을 위해 GRI-v3.0의 상세화학반응기구를 사용하였으며, 단열계산과 광학적으로 얇은 복사모델을 적용하여 계산을 수행하였다. 대향류 유동장의 점화와 소화점을 정확히 찾기 위하여 화염제어 연속계산법을 적용하였다. 결과를 통해 스트레인율 변화에 대해 최고 온도보다는 최고 H 라디칼 농도가 점화와 소화거동을 이해하는데 더 적합하다는 것을 확인하였다. 최고 H 라디칼 농도변화 거동을 통해 기존에 알려진 S-곡선, C-곡선 및 O-곡선 등을 확인하였다. 복사열손실 분율($f_r$)과 공간에 대해 적분된 열발생률(IHRR)을 통해 $f_r$이 가장 큰 점에서 복사효과에 의한 소화가 발생하였으며, 화염신장 소화점에서는 IHRR이 가장 높지만 화염에서의 전도에 의한 열손실로 인해 소화가 되는 것을 확인하였다. 복사는 화염신장 소화점에는 거의 영향이 없지만 복사 소화점과 점화점에는 큰 영향을 주는 것을 알 수 있었다. 또한 연료의 온도가 높아질수록 복사에 의한 소화점의 스트레인율과 화염신장에 의한 스트레인율 사이의 영역이 넓어지게 되어 화염 안정성이 향상되고 있음을 알 수 있었다.

Postoperative irradiation after implant placement: A pilot study for prosthetic reconstruction

  • Doh, Re-Mee;Kim, Sungtae;Keum, Ki Chang;Kim, Jun Won;Shim, June-Sung;Jung, Han-Sung;Park, Kyeong-Mee;Chung, Moon-Kyu
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권5호
    • /
    • pp.363-371
    • /
    • 2016
  • PURPOSE. On maxillofacial tumor patients, oral implant placement prior to postoperative radiotherapy can shorten the period of prosthetic reconstruction. There is still lack of research on effects of post-implant radiotherapy such as healing process or loading time, which is important for prosthodontic treatment planning. Therefore, this study evaluated the effects of post-implant local irradiation on the osseointegration of implants during different healing stages. MATERIALS AND METHODS. Custom-made implants were placed bilaterally on maxillary posterior edentulous area 4 weeks after extraction of the maxillary first molars in Forty-eight Sprague-Dawley rats. Experimental group (exp.) received radiation after implant surgery and the other group (control) didn't. Each group was divided into three sub-groups according to the healing time (2, 4, and 8 week) from implant placement. The exp. group 1, 2 received 15-Gy radiation 1 day after implant placement (immediate irradiation). The exp. group 3 received 15-Gy radiation 4 weeks after implant placement (delayed irradiation). RESULTS. The bone mineral density (BMD) was significantly lower in the immediate irradiation groups. BMD was similar in the delayed irradiation group and the control group. The irradiated groups exhibited a lower bone-to-implant contact ratio, although the difference was not statistically significant. The irradiated groups also exhibited a significantly lower bone volume and higher empty lacuna count than the control groups. No implant failure due to local irradiation was found in this study. CONCLUSION. Within the limits of this study, the timing of local irradiation critically influences the bone healing mechanism, which is related to loading time of prostheses.

Multivariate statistical study on naturally occurring radioactive materials and radiation hazards in lakes around a Chinese petroleum industrial area

  • Yan Shi;Junfeng Zhao;Baiyao Ding;Yue Zhang;Zhigang Li;Mohsen M.M.Ali;Tuya Siqin;Hongtao Zhao;Yongjun Liu;Weiguo Jiang;Peng Wu
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2182-2189
    • /
    • 2024
  • The high-purity germanium gamma-ray spectrometer was used to measure the radioisotope in surface water of lakes in a Chinee petroleum industrial area. 92 samples were collected from surface water of three lakes. Activity concentrations of 232Th, 226Ra and 40K in three lakes were measured, distributed in the range of 101.8-209.4, 192.1-224.9 and 335.0-548.9 mBq/L, respectively. Results were all within the limits of WHO and China. Potential environmental and health risks were assessed by calculating some radiation hazard indicators, radium equivalent index, annual effective dose, excess lifetime cancer risk, absorbed dose rate, external hazard index, internal hazard index, annual gonadal dose equivalent, activity utilization index and representative gamma index, which ranged 0.38-0.54 Bq/L, 0.06-0.08 mSv/y, 0.23 × 10-3-0.31 × 10-3, 0.17-0.24 nGy/h, 1.01 × 10-3-1.46 × 10-3, 1.55 × 10-3-2.02 × 10-3, 1.16-1.66 μSv/y, 3.13 × 10-3-4.45 × 10-3 and 2.60 × 10-3-3.77 × 10-3. The results were all at acceptable levels, meaning no impact on human health. The relationship between the electrical conductivity of surface water and the activity concentration of 232Th, 226Ra and 40K was evaluated. The electrical conductivity value was 0.241-0.369 mS/cm, showing a significant correlation coefficient between 226Ra and 40K and electrical conductivity. Multivariate statistical methods were used to determine the relationship between the activity concentrations of 232Th, 226Ra, and 40K, radiation hazard indicators and electrical conductivity.

세기조절방사선치료 시 치료 부위에 따른 치료계획 시스템 간 선량평가 (Dose Evaluation of TPS according to Treatment Sites in IMRT)

  • 김진만;김종식;홍채선;박주영;박수연;주상규
    • 대한방사선치료학회지
    • /
    • 제25권2호
    • /
    • pp.181-186
    • /
    • 2013
  • 목 적: 본 연구는 치료계획 시스템인 $Pinnacle^3$ (version 9.2, Philips Medical Systems, USA)과 Eclipse (version 10.0, Varian Medical Systems, USA)을 이용하여 전립선암과 폐암의 세기조절방사선 치료계획시 불균질 부위의 선량 계산 차이를 알고리즘별로 알아보고자 한다. 대상 및 방법: 각 5명의 전립선암 및 폐암 환자를 대상으로, 본원 Protocol에 따른 동일한 조건으로 최적화 계산을 진행하였다. 전립선암 환자의 치료계획은 10 MV, 7Beam을 사용하였으며 2.5 Gy씩 28 fx, 총 70 Gy를 동일 처방하였고, 폐암 환자의 치료계획은 6 MV, 6Beam을 사용하였으며 2 Gy씩 33 fx, 총 66 Gy를 동일 처방하였다. 두 치료계획시스템을 통해 CTV, PTV 및 종양주위의 OAR의 최대선량, 평균선량, 최소선량을 비교하였다. 결 과: 전립선암에서 두 치료계획시스템 모두 CTV와 PTV의 선량변화가 2%이내였으며 종양주변 정상 장기(방광, 대퇴골, 직장)도 선량제약조건을 충족하였다. 폐암에서도 CTV와 PTV는 2%이내의 선량변화를 보였고, 정상 장기(식도, 척수, 양측 폐)도 선량제약 조건을 충족하였다. 하지만, Eclipse 치료계획의 최소선량은 CTV에서 1.9%, PTV에서 3.5% 높았고 양측 폐의 경우 V5 Gy에서 3.0% 높은 차이를 보였다. 결 론: 치료부위에 따른 각각의 치료계획시스템은 본원의 선량제한 조건을 모두 만족하여 임상적 정확성을 확인할 수 있었다. 향후 다양한 부위의 치료계획 연구와 치료계획시스템의 적용은 보다 정확한 치료계획을 위한 방법을 제시할 것이라 사료된다.

  • PDF

위상기반 호흡연동 방사선치료 시 오차 분석 프로그램 개발 (Development of Error Analysis Program for Phase-based Respiratory Gating Radiation Therapy)

  • 송주영;나병식;정웅기;안성자;남택근;윤미선
    • 한국의학물리학회지:의학물리
    • /
    • 제17권3호
    • /
    • pp.136-143
    • /
    • 2006
  • 방사선 치료 시 환자 호흡에 의한 치료부위의 움직임 영향을 줄이기 위해 환자 복부에 배치한 적외선 반사체 표식자의 호흡에 따른 주기적 움직임을 분석하여 안정된 일정 영역에서만 방사선이 조사되도록 하는 호흡연동 방사선치료 방법이 임상에서 활용되고 있다. 이러한 호흡연동 방사선치료에서 표식자의 운동 주기 중 안정된 특정 위상영역을 기반으로 방사선 조사 구간을 설정하는 방법은 진폭변위를 기반으로 하는 방법보다 안정적으로 치료를 수행할 수 있는 장점이 있으나, 치료 시 방사선 조사 구간 내 표식자 진폭의 변화가 발생해도 설정 위상 기반영역에만 포함되면 방사선이 조사되는 경우가 발생할 수 있어, 실제 호흡량의 변위에 따른 내부 장기의 움직임 정도를 정확히 반영하기에는 한계가 있다. 본 연구에서는 이와 같은 위상기반 호흡연동 방사선치료 시 발생할 수 있는 표식자 진폭의 변화와 이로 인한 치료 부위의 움직임에 의한 오차를 분석할 수 있는 프로그램을 개발하여 정확성과 임상 적용 타당성을 분석하였다. 모의치료 시 설정된 방사선 조사 구간 내 가상의 진폭 변위를 주어 작성한 치료 기록 파일과 팬텀을 사용하여 임상에서 발생할 수 있는 진폭 변위의 크기와 불규칙한 변화가 발생하였을 경우의 환경 설정 후 방사선을 조사하고 생성된 치료 기록 파일들을 개발한 프로그램으로 분석하였을 때, 정확한 오차 구간의 판별과 오차 계산이 수행됨을 확인할 수 있었다. 실제 위상기반 호흡연동 방사선 치료 환자에 적용하였을 때에도 설정된 허용기준을 벗어나는 지점의 오차 영역 인식과 오차 계산이 정확히 수행됨을 확인하여, 향후 위상기반 호흡연동 방사선치료 시 발생할 수 있는 방사선 조사 구간 내 환자 호흡량의 변화로 인한 치료 표적의 변위 오차 분석에 유용한 도구로 사용될 것으로 생각된다.

  • PDF

의료기관 내 방사선사의 검사 한도 설정에 관한 연구 (A Study on the Setting of Examination Limits for Radiographers in Medical Institutions)

  • 김정호;김갑중
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.401-410
    • /
    • 2023
  • 방사선사는 영상진단장치를 담당하는 직종으로 적절한 업무 수준을 제시하여 국민건강 증진에 기여하여야 한다. 이를 위해 업무에 따른 인체 유해성 평가, 설문지를 통한 통계 평가, 국내·외 동향을 통해 적절한 업무 수준을 제시하고자 한다. 인체 유해성 평가의 경우 방사선 피폭을 고려하여 42.6 %, 차폐체 작업은 69.7 %, MRI의 경우 검사실 체류시간이 최대 15분, 30회를 초과하지 않도록 조절하여야 한다. 설문통계에서는 근로시간 대비 업무량 및 난이도가 높아 신체적, 정신적 부담이 증가됨을 확인할 수 있었으며, 국내·외 동향을 통해 국내 방사선사의 검사 기준을 36.8 %까지 조절하여 방사선 검사의 질적 향상을 통해 국민건강증진을 도모하여야 한다.

최소검출한계, 잠상퇴행 및 반복사용으로 인한 감도면화 결정에 의한 $CaSO_4$:Dy 열형광선량계 특성 (Characteristics of $CaSO_4$:Dy TL Dosimeters by Determining LLDs, Fadings and Sensitivity Changes in Repeat Uses)

  • 김장렬;김봉환;장시영;이형섭;이재기
    • Journal of Radiation Protection and Research
    • /
    • 제22권3호
    • /
    • pp.161-170
    • /
    • 1997
  • 현재 한국원자력연구소에서 개인방사선피폭관리용으로 사용되고 있는 C-300-A $CaSO_4$:Dy 열형광선량재의 최소검출한계(LLD)를 계산 및 실험에 의하여 구하였으며, 이때 오차의 확율이 자연방사선의 측정변화에 기인되는 선량준위로 정의되는 임계준위도 함께 구하였다. 개인방사선피폭서비스를 수행하는 기관에서는 이를 이용하여 개인선량계 패용 기간동안의 자연방사선 판독결과와 기지의 선량을 조사시킨 선량제의 판독결과로부터 쉽게 LLD를 구할수 있다. 또한 3개월간에 걸쳐 온도 및 습도의 변화에 따른 개인선량제의 잠상퇴행률을 실험적으로 구하였다. 마지막으로 40회 연속사용시 개인선량계의 반복사용에 의한 감도변화를 측정하였다. 본 실험결과 얻어진 잠상퇴행률과 연속사용시의 감도변화를 실제 개인방사선피폭 평가시 적용방법에 대하여 간략하게 논의하였다.

  • PDF

ALARA 개념(槪念)에 의한 기체상방사성물질(氣體狀放射性物質)의 환경방출한도(環境放出限度) 설정(設定) (Establishment of Release Limits for Airborne Effluent into the Environment Based on ALARA Concept)

  • 이병기;차문회;남순권;장시영;하정우
    • Journal of Radiation Protection and Research
    • /
    • 제10권1호
    • /
    • pp.50-63
    • /
    • 1985
  • 농축인자법(濃縮因子法)(Concentration Factor Method)을 이용(利用)하여 결정피폭경로(決定被曝經路)를 분석(分析)한 후(後) 표준원전(標準原電)의 기체상방사성대기방출물(氣體狀放射性大氣放出物)에 대한 유도방출한도(誘導放出限度)(Derived Release Limits, DRL's)를 계산(計算)하였다. 이 방출한도(放出限度)는 핵시설(核施設) 주변(周邊)의 결정군구성개인(決定群構成個人)에 대(對)한 방사선(放射線) 피폭(被曝)을 관련피폭한도이하(關聯被曝限度以下)로 유지(維持)시키는 양(量)이다 본(本) 연구(硏究)에서는 1985년(年) 초(初) 미국(美國)의 환경보호청(環境保護廳)(EPA)에서 새로 권고(勸告)한 피폭한도(被曝限度)를 채택(採擇)하여 계산(計算)을 수행(遂行)하였다. 유도방출한도(誘導放出限度)(DRL)의 계산(計算)은 미국(美國)의 원자력(原子力) 규제위원회(規制委員會)(USNRC)가 규제지침(規制指針)(Reg. Guide) 1.109에서 제시(提示)하고 있는 선양평가(線量評價)모델을 표준(標準)모델로 사용(使用)하여 수행(遂行)하였으나, 동(同) 모델의 피폭경로분석(被曝經路分析)에서 우유(牛乳) 및 육류(肉類)의 섭취경로(攝取經路)는 국내(國內)의 현실상(現實狀) 무시가능(無視可能)한 것으로 고려(考慮)하여 본(本) 연구(硏究)에서 제외(除外)시켰다. 계산(計算)에서 고려(考慮)한 방출선원항(放出線源項)은 희유기체(稀有氣體), 요오드, 입자상원소(粒子狀元素) 및 삼중수소기체(三重水素氣體)였으며, 방출원(放出源)에서 북(北)쪽으로 1.3 km 거리에 위치(位置)하고 있는 주민영구거주지역(住民永久居住地域)을 대상(對象)으로 계산(計算)을 수행(遂行)하였다. 본(本) 연구(硏究)에서는 표준원전(標準原電)의 대상(對象)으로 고리원전(古里原電) 1호기(號機)를 선정(選定)하여 동원전(同原電)의 연간방출(年間放出)에 대(對)한 유도한도(誘導限度)를 계산(計算)하였으며, 1982년도(年度)의 실방출률(實放出率)과 비교(比較) 검토(檢討)하였다. 검토결과(檢討結果), 고리원전(古里原電) 1호기(號機)의 1982년도(年度)의 실방출률(實放出率)은 본(本) 연구(硏究)에서 구(求)해진 유도방출한도(誘導放出限度)보다 낮았으며, 방출물(放出物)에 의한 시설주변(施設周邊) 개인(個人)의 년간피폭선량(年間被曝線量)은 EPA에서 권고(勸告)하는 피폭한도이하(被曝限度以下)로 유지(維持)되었음을 알 수 있었다. 또한 본(本) 연구(硏究)에서 가장 결정적(決定的)인 피폭경로(被曝經路)는Co-60와 Cs-137과 같은 입자상침적방사핵종(粒子狀沈積放射核種)으로 오염(汚染)된 토양(土壤)에 의한 전신외부(全身外部) 피폭경로(被曝經路)였다.

  • PDF