A Study on Radiation Hardening of a Infrared Detector (적외선 탐지소자의 내방사선화 연구)

  • Lee, Nam-Ho;Kim, Seung-Ho;Kim, Young-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.11
    • /
    • pp.490-492
    • /
    • 2005
  • A study on radiation hardening of infrared(IR) detector, the chief component of IR camera was performed. The radiation test on IR sensor passivated with the ZnS by Co$^{60}$ gamma-ray over 1 Mrads showed the reduction in Ro by 1/100 which was related to the noise level. This effect that was caused by carrier trapping in the ZnS passivation layer increased the leakage current and resulted in degradation in the device performance. For the radiation hardening of IR devices we suggested the ones with CdTe passivation layer which had a tendency to reluctant to carrier trapping in its layer and developed test patterns. Radiation test to the patterns showed that the our CdTe passivated device could survived over 1 Mrad gamma-ray dose.

A Methodology of Dual Gate MOSFET Dosimeter with Compensated Temperature Sensitivity

  • Lho, Young-Hwan
    • Journal of IKEEE
    • /
    • v.15 no.2
    • /
    • pp.143-148
    • /
    • 2011
  • MOS (Metal-Oxide Semconductor) devices among the most sensistive of all semiconductors to radiation, in particular ionizing radiation, showing much change even after a relatively low dose. The necessity of a radiation dosimeter robust enough for the working environment has increased in the fields of aerospace, radio-therapy, atomic power plant facilities, and other places where radiation exists. The power MOSFET (Metal-Oxide Semiconductor Field-Effect Transistor) has been tested for use as a gamma radiation dosimeter by measuring the variation of threshold voltage based on the quantity of dose, and a maximum total dose of 30 krad exposed to a $^{60}Co$ ${\gamma}$-radiation source, which is sensitive to environment parameters such as temperature. The gate oxide structures give the main influence on the changes in the electrical characteristics affected by irradiation. The variation of threshold voltage on the operating temperature has caused errors, and needs calibration. These effects can be overcome by adjusting gate oxide thickness and implanting impurity at the surface of well region in MOSFET.

The Effects of Nanoparticles for Irradiation (방사선조사에서 나노 입자 혼합물의 영향)

  • Yea, Ji-Woon;Shin, Hyun-Jin
    • Journal of Yeungnam Medical Science
    • /
    • v.28 no.2
    • /
    • pp.145-152
    • /
    • 2011
  • Background: To evaluate the changes in the radiation dose and temperature distribution on irradiated egg albumin and nanoparticle ($Fe_3O_4$) powder mixed egg albumin. Methods: A new type of phantom was designed by fabricating a $30{\times}30{\times}30cm$ acryl square inside a $3{\times}3{\times}3cm$ small square and dividing it into two parts. In the control group, only egg albumin was irradiated, and in the test group, 25 nm 20 mg/cc, 25 nm 40 mg/cc, and 1 um 40mg/cc nanoparticles with egg albumin were irradiated. The radiation isodose distributions and temperature changes were then observed. Results: No significant changes were observed in the radiation dose and temperature distribution. Conclusion: The nanoparticles were considered not to have had any effect on the radiation dose and temperature distribution under the experimental conditions. Further studies can be conducted based on the changes in the mixture material.

  • PDF

Radiation Effects on the Flame Structure and Extinction Limit of Counterflow Partially Premixed Methane Flames Diluted with Water Vapor in the Air Stream (공기류측에 수증기가 첨가된 대향류 메탄 부분예혼합화염의 화염구조 및 소화한계에 미치는 복사효과)

  • Park, Ji-Woong;Oh, Chang Bo;Kim, Ook Joong
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.325-328
    • /
    • 2012
  • Radiation effects on the partially premixed methane flames diluted with water vapor in the air stream were numerically investigated. OPPDIF code and GRI-v3.0 were used in the numerical simulation. Adiabatic condition was compared with two different radiation models, optically-thin and WSGGM models. It was found that the radiation effect on the flame structure for the equivalence ratio (${\Phi}$) of 2.5 was less than ${\Phi}=1.5$. Extinction limit was not affected significantly, however, local flame structure was markedly influenced by the radiation models as increasing the water vapor concentration.

  • PDF

SRS Inversion of Flame Temperature/concentration Profile with Radiation/Turbulence Interaction (복사/난류간 상호작용이 고려된 화염의 온도 및 농도분포의 SRS 역계산)

  • Ko, Ju-Yong;Kim, Hyun-Keol;Song, Tae-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.9 s.252
    • /
    • pp.891-897
    • /
    • 2006
  • The SRS method is applied to a turbulent flame with radiation/turbulence interaction to invert the temperature and concentration profile. The flame is conditioned as optically thin per each fluctuation length and the flame spectral intensity is measured for inversion. From inversion result, we find that SRS can successfully invert the coupled temperature/concentration fluctuation amplitudes. For two cases of experiments, inverted values are within approximately 1% over the full range of fluctuation amplitude. However, SRS cannot find the detailed local fluctuation parameters such as pattern and phase, etc. as far as they do not affect the resulting radiation intensity. Important available parameters are the mean temperature and the temperature fluctuation amplitude. The radiation/turbulence interaction effect is verified to play an important role in the radiation.

Effect of Radiotherapy on the Ascorbate (Vitamin C) Levels in Whole Blood and Plasmas (방사선 조사가 체내 아스코베이트(비타민 C)농도에 이치는 영향)

  • Choi, Gyu-Young;Yoon, Sang
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.227-231
    • /
    • 1993
  • The role of ascorbate as an antioxidant in the prevention and cure of disease that result from free radicals has been of considerable interest and controversy lately. As an antioxidant, we can expect it to protect against radiation damage caused by free radicals that are produced when radiation, especially sparsely ionizing radiation, interacts with living tissues. The plasma and whole blood concentration of ascorbate was analyzed before and just after the radiation therapy for the purpose of estimating the consumption amount of ascorbate during radiotherapy. Whole blood ascorbate was decreased from 1.82 mg/dl to 1.58 mg/dl, plasma ascorbate was decreased from 1.13 mg/dl to 1.08 mg/dl, and urine ascorbate was decreased from 9.33 mg/dl to 6.96 mg/dl after radiotherapy. Although the difference was not significant statistically, further human study should be followed to define the role of ascorbate as a radioprotector.

  • PDF

Effects of Radiation-Counseling Convergence Education on Radiation Awareness (방사선카운슬링 융합교육이 방사선 인식도에 미치는 영향)

  • Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.323-329
    • /
    • 2017
  • The purpose of study was to analysis on the effects of radiation-counseling convergence education on radiation awareness. The survey objects were students of radiation-counseling convergence education from 12th May to 22th June in 2016. The questionnaires were education satisfactions and radiation awareness (risk, benefit, control) by Likert-type 5 scales. The analysis results revealed that education satisfactions of men students showed a significant higher female students and correlation coefficient of education satisfactions were the best high in the benefit and control of radiation. Finally radiation-counseling convergence education had a significant effect on radiation benefit. This convergence education influenced positive recognition on radiation benefit and it was indicated that radiation-counselors could treat clients on the basis of radiation benefit.

Development of Radiation Restrictor for Secondary Radiation Shielding of Mobile X-ray Generator (이동형 X선 발생장치의 2차 방사선 차폐를 위한 선속조절기 개발 연구)

  • Koo, Bon-Yeoul;Kim, Gha-Jung
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.397-403
    • /
    • 2018
  • Mobile X-ray generators are used not in the radiation area but in open space, which causes the exposure of secondary radiation to the healthcare professionals, patients, guardians, etc., regardless of their intentions. This study aimed to investigate the shielding effect of the developed radiation restrictor to block the secondary radiation scattered during the use of mobile X-ray generator. Upon setting the condition of mobile X-ray generator with chest AP, spatial doses were measured by the existence of human equivalent phantom and radiation restrictor, and measured by the existences of phantom and radiation restrictor at the same length of 100 cm. Measurements were taken at intervals of 10 cm every $30^{\circ}$ from $-90^{\circ}$ (head direction) to $+90^{\circ}$ (body direction). Upon the study results, spatial doses in all direction were increased by 45% on average when using phantom in the same condition, however, they were decreased by 64% on average when using the developed radiation restrictor. The dose at 100 cm from the center of X-ray was $3.0{\pm}0.08{\mu}Gy$ without phantom and was increased by 40% with $4.2{\pm}0.08{\mu}Gy$ after phantom usage. The dose when using phantom and the developed radiation restrictor was $1.4{\pm}0.08{\mu}Gy$, which was decreased by 66% compared to the case without using them. Therefore, it is considered the scattered radiation can be shielded at 100-150 cm, the regulation of the distance between beds, effectively with the developed radiation restrictor when using mobile X-ray generators, which can lower the radiation exposure to the people nearby including healthcare professionals and patients.

Structural Relationship for Recognition of Radiation Risks on Management and Benefits of the University Students (대학생들의 방사선 위험 인식이 관리와 편익에 미치는 구조적 관계)

  • Seoung, Youl-Hun;Kim, Sung-Soo
    • Journal of Digital Convergence
    • /
    • v.12 no.2
    • /
    • pp.431-437
    • /
    • 2014
  • The purpose of this study was to perform an actual proof analysis on the structural effects of recognition of radiation risks on management and benefits. Data was collected using self-administered questionnaires targeting students having majors related to radiation from 1 April to 31 May in 2013 of one four-year-course university located in Chungbuk, Korea. As a result of the analysis, it turned out that as recognition of radiation risks is higher, recognition of radiation management is higher, which has a significant effect on benefits. It was indicated that although recognition of radiation risks does not directly influence radiation benefits, positive recognition on radiation benefits could increase through the parameter, radiation management. In order to improve smooth use of radiation and increase benefits, education that emphasizes the need of proper radiation management should be performed.

A Review of Dose Rate Meters as First Responders to Ionising Radiation

  • Akber, Aqeel Ahmad;Wiggins, Matthew Benfield
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.3
    • /
    • pp.97-102
    • /
    • 2019
  • Background: Dose rate meters are the most widely used, and perhaps one of the most important tools for the measurement of ionising radiation. They are often the first, or only, device available to a user for an instant check of radiation dose at a certain location. Throughout the world, radiation safety practices rely strongly on the output of these dose rate meters. But how well do we know the quality of their output? Materials and Methods: This review is based on the measurements 1,158 commercially available dose rate meters of 116 different makes and models. Expected versus the displayed dose patterns and consistency was checked at various dose rates between $5{\mu}Gy{\cdot}h^{-1}$ and $2mGy{\cdot}h^{-1}$. Samples of these meters were then selected for further investigation and were exposed to radiation sources covering photon energies from 50 keV to 1.5 MeV. The effect of detector orientation on its reading was also investigated. Rather than focusing on the angular response distribution that is often reported by the manufacturer of the device, this study focussed on the design ergonomics i.e. the angles that the operator will realistically use to measure a dose rate. Results and Discussion: This review shows the scope and boundaries of the ionising radiation dose rate estimations that are made using commonly available meters. Observations showed both inter and intra make and model variations, occasional cases of instrument failure, instrument walk away, and erroneous response. Conclusion: The results indicate the significance of selecting and maintaining suitable monitors for specific applications in radiation safety.