• 제목/요약/키워드: Radiated Susceptibility : RS

검색결과 9건 처리시간 0.034초

Proposing a low-frequency radiated magnetic field susceptibility (RS101) test exemption criterion for NPPs

  • Min, Moon-Gi;Lee, Jae-Ki;Lee, Kwang-Hyun;Lee, Dongil
    • Nuclear Engineering and Technology
    • /
    • 제51권4호
    • /
    • pp.1032-1036
    • /
    • 2019
  • When the equipment which is related to safety or important to power production is installed in nuclear power plant units (NPPs), verification of equipment Electromagnetic Susceptibility (EMS) must be performed. The low-frequency radiated magnetic field susceptibility (RS101) test is one of the EMS tests specified in U.S NRC (Nuclear Regulatory Commission) Regulatory Guide (RG) 1.180 revision 1. The RS101 test verifies the ability of equipment installed in close proximity to sources of large radiated magnetic fields to withstand them. However, RG 1.180 revision 1 allows for an exemption of the low-frequency radiated magnetic susceptibility (RS101) test if the safety-related equipment will not be installed in areas with strong sources of magnetic fields. There is no specific exemption criterion in RG 1.180 revision 1. EPRI TR-102323 revision 4 specifically provides a guide that the low-frequency radiated magnetic field susceptibility (RS101) test can be conservatively exempted for equipment installed at least 1 m away from the sources of large magnetic fields (>300 A/m). But there is no exemption criterion for equipment installed within 1 m of the sources of smaller magnetic fields (<300 A/m). Since some types of equipment radiating magnetic flux are often installed near safety related equipment in an electrical equipment room (EER) and main control room (MCR), the RS101 test exemption criterion needs to be reasonably defined for the cases of installation within 1 m. There is also insufficient data regarding the strength of magnetic fields that can be used in NPPs. In order to ensure confidence in the RS101 test exemption criterion, we measured the strength of low-frequency radiated magnetic fields by distance. This study is expected to provide an insight into the RS101 test exemption criterion that meets the RG 1.180 revision 1. It also provides a margin analysis that can be used to mitigate the influence of low-frequency radiated magnetic field sources in NPPs.

통신해양기상위성과 정지궤도 발사체와의 전자파 적합성 해석 (Preliminary EMC Analysis between the COMS and the GEO Launch Vehicles)

  • 김의찬;이흥호
    • 전기학회논문지
    • /
    • 제57권3호
    • /
    • pp.439-445
    • /
    • 2008
  • In this paper, the preliminary EMC analysis process between the Communication, Ocean and Meteorological Satellite (COMS) and Geostationary Earth Orbit (GEO) launch vehicles in the frequency range [1MHz-47MHz] is described. The considered launch vehicles are arian V, sea Launch, land Launch, atlas III&V, delta IV, proton M/breeze M, soyuz, HII-A and Angara. The launch vehicle Radiated Emission (RE) specifications have been compared to COMS satellite Radiated Susceptibility (RS) limits. The COMS RS limits are the RS qualification levels of COMS units during launch. As a result, The radiated emission levels of arian V, sea launch, atlas III&V, delta IV, proton M/breeze M, HII-A and angara are compliant with COMS RS limits. The negative margins appear between land launch or soyuz launch vehicle RE and COMS RS. Then, if the land launch or soyuz is chosen by the customer, The tests should be performed at satellite level in order to demonstrate the compatibility with respect to launch vehicles specifications.

통신해양기상위성 복사방출과 정지궤도 발사체 복사감응과의 전자파 적합성 해석 (The Preliminary EMC Analysis Between the COMS RE and the GEO Launch Vehicles RS)

  • 김의찬;이승민
    • 전기학회논문지
    • /
    • 제59권4호
    • /
    • pp.774-778
    • /
    • 2010
  • In this paper, the preliminary EMC analysis process between the Communication, Ocean and Meteorological Satellite (COMS) and the Geostationary Earth Orbit (GEO) launch vehicles in the frequency range is described. The considered launch vehicles are Arian Ⅴ, Sea Launch, Land Launch, Atlas III&Ⅴ, Delta IV, Proton M/breeze M, Soyuz, H II-Aa. The launch vehicle Radiated Susceptibility (RS) specifications have been compared to COMS satellite Radiated Emission (RE) limits. The COMS Radiated Emission (RE) level is determined by calculating the radiated field equal to the quadratic sum of radiated emissions of each equipment switched "ON" during launch. As a result, The RS requirements of Arian V, Atlas III&V and Delta IV lauchers are compliant with COMS RE limits. The negative margins appear between the others launch vehicle RS (Sea Launch, Land Launch, Proton M/Breeze M, Soyuz and H II-A) and COMS RE. Then, if the launchers that have negative margin were chosen by the customer, The EMC tests should be performed at satellite level in order to demonstrate the compatibility with respect to launch vehicles requirements.

통신해양기상위성 복사감응과 정지궤도 발사체 복사방출에 대한 EMC 해석 (EMC Analysis between the COMS RS and the GEO Launch Vehicles RE)

  • 김의찬;한조영;이호형
    • 항공우주기술
    • /
    • 제8권2호
    • /
    • pp.33-40
    • /
    • 2009
  • 본 논문에서 [1MHz-47MHz]의 주파수 범위에서의 통신해양기상위성과 정지궤도 발사체와의 예비적인 EMC 해석 과정을 기술한다. 정지궤도용 발사체 최대 복사 방출 한계치와 위성의 최대 복사 감응 한계치와 비교한다. 전자파 호환이 되지 않는 발사체로는 land launch와 소유즈가 있다. 만약에 이 발사체가 선정된다면 위성체 레벨에서 전자파 시험을 통하여 검증하여야 한다.

  • PDF

정지궤도위성과 발사체와의 전자파 적합성 해석 (Preliminary EMC Analysis between the COMS and the Arian V Launch Vehicles)

  • 김의찬;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1403-1405
    • /
    • 2008
  • In this paper, the preliminary EMC analysis process between the Communication, Ocean and Meteorological Satellite (COMS) and Geostationary Earth Orbit (GEO) launch vehicles in the frequency range [1MHz-47MHz] is described. The considered launch vehicle is the Arian V. The launch vehicle Radiated Emission (RE) specifications have been compared to COMS satellite Radiated Susceptibility (RS) limits. The COMS RS limits are the RS qualification levels of COMS units during launch. As a result, The radiated emission levels of the Arian V is compliant with COMS RS limits.

  • PDF

인공위성 S-band가 형성한 발사체 패어링내의 전기장 해석 (The analysis of E-field produced by satellite S-band under fairing of launcher)

  • 김의찬;이상곤
    • 항공우주기술
    • /
    • 제10권2호
    • /
    • pp.82-86
    • /
    • 2011
  • 본 논문에서는 통신해양기상위성의 TM 안테나[2.290 GHz]에 의해 발생된 RF가 발사체 PROTON M/Breeze M long 패어링 안에서 형성되는 전기장의 세기를 예측한다. 위성이 TM을 내보내기 위해 의도적으로 방사하는 전기장의 세기는 PROTON M / BREEZE M 패어링의 특성을 고려함으로써 예측될수 있다. 다른 정지궤도 발사체는 PROTON의 패어링과 유사한 특성을 갖기 때문에, 예측된 결과가 다른 발사체에도 적용될 것이라 예상된다. 해석결과로써, 패어링내의 전기장의 세기는 위성 본체와는 전자파 적합성 요구사항을 만족하나, 발사체 PROTON M/Breeze M과는 전자파 적합성 요구사항을 만족하지 못한다.

영상레이더 위성시스템 구조물의 RF 간섭특성 분석 및 검증 (RF Interference Analysis and Verification in the Synthetic Aperture Radar Satellite System)

  • 장재웅;김태윤;임성빈
    • 항공우주기술
    • /
    • 제8권1호
    • /
    • pp.187-196
    • /
    • 2009
  • 지구관측을 위한 영상레이더 위성시스템은 고전력의 고주파 신호를 방출하는 영상레이더를 비롯하여, 획득한 영상 이미지 전송을 위한 데이터 링크 시스템, 위성 운용을 위해 지상과 통신하기 위한 원격측정명령계 시스템 등의 다양한 주파수를 가지는 RF 시스템을 탑재한다. 각각의 시스템은 다양한 주파수 성분을 가진 RF 신호를 송출할 뿐만 아니라 매우 높은 RF 전력을 복사하므로 위성체에 장착된 전기전자부품에서의 복사 내성 규격을 초과할 수 있다. 또한, RF를 송수신하는 여러 서브 시스템간 간섭 문제가 발생할 수 있다. 따라서, 영상레이더 위성과 동일한 형상을 가진 시스템 구조모델을 제작하고 위성에 탑재되는 RF시스템과 유사한 전기적인 특성을 가지는 안테나를 제작 및 설치하여 위성 운용시 발생할 수 있는 RF 간섭에 의한 영향을 분석 및 검증하였다.

  • PDF

추적 레이다 시스템의 전자기파 내성 설계 (Electromagnetic Susceptibility Design of Tracking Radar Systems)

  • 김홍락;김윤진;박성호;이만희;이다빈
    • 한국인터넷방송통신학회논문지
    • /
    • 제23권2호
    • /
    • pp.51-59
    • /
    • 2023
  • 추적 레이다 시스템은 지상, 함정, 항공기 등에 탑재되어 운용되며 주변의 전자장치들과의 전자기파 간섭에 대한 내성 설계가 필요하다. 특히 함정에 설치되는 추적레이다 및 항공기에 탑재되는 추적레이다의 경우 주변 여러 창치들과 전원 라인과 통신 라인으로 전기적 연결이 되어 있다. 이러한 경우 추적레이다와 연결된 케이블에 의한 전자기파 간섭에 의한 다른 장비들의 오동작을 방지하기 위하여 케이블 연결에 대한 방사규격과 내성규격을 만족해야 한다. 또한 추적레이다에서 생성되어 방사되는 전자기파 잡음이 주변장치에 영향을 주지 않도록 방사 규격 또한 만족해야 하여 주변 장치에서 방사되어 입력되는 전자기파에 대한 내성 규격을 만족 해야 한다. 본 논문에서는 CE, CS, RE, RS를 포함하는 MIL-STD-461G를 만족하기 위한 설계를 제시하고 시험을 통하여 설계 만족에 대하여 설명한다.

EMC 시험을 위한 EUT 시험장비 설계 (Design of EUT test equipment for EMC Testing)

  • 김홍락;김윤진;박성호;이만희
    • 한국인터넷방송통신학회논문지
    • /
    • 제23권4호
    • /
    • pp.35-40
    • /
    • 2023
  • EMC 시험을 위해서는 EUT가 정상적인 동작을 유지하고 있는 상황에서 EUT의 방사 특성과 내성 특성을 측정하게 된다. EUT의 정상적인 동작을 위해서는 무반향 챔버 외부에서 별도의 장비를 통하여 EUT를 동작시키고 상태를 모니터링해야 한다. 외부 장비는 1553B 통신, RS-485 통신, Ethernet 통신 등 다양한 통신을 통하여 EUT를 동작시키고 모니터링을 하게 된다. 이때 외부 장비가 통신 LINE을 통하여 잡음을 전달할 수 있다. 이러한 잡음은 연결된 전원케이블을 통하여 LISN에 전달되어 측정되게 된다. 또한 LISN에 연결단자를 통하여 방사되기도 한다. 이러한 경우 통신 LINE이 전원 LINE과 최대한 전자기적 격리를 통하여 잡음이 전달되지 못하도록 설계하여야 한다. 또한 외부 장비의 잡음이 통신 LINE을 통하여 챔버안으로 들어가는 것을 최대한 억압하야여 한다. 본 논문에서는 EMC 시험을 위하여 적용되는 외부의 EUT 시험장비의 설계 및 제작시 고려사항들에 대하여 설명하고 CE, RE를 포함한 시험을 통하여 설계 만족에 대하여 설명한다.