• 제목/요약/키워드: Radial Ejection

검색결과 17건 처리시간 0.027초

축방향 유입과 반경방향 유출이 있는 회전용기 내의 유동해석 (Flow Analysis in a Rotating Container with Axial Injection and Radial Ejection)

  • 박준상;손진국
    • 한국가시화정보학회지
    • /
    • 제9권1호
    • /
    • pp.49-54
    • /
    • 2011
  • An investigation has been made of a viscous incompressible flow in a circular cylindrical tank. The flow is driven by the spinning bottom disk of tank together with/without central injection and radial uniform-ejection through the sidewall. Numerical solutions of steady and unsteady flows to 3-dimensional Navier-Stokes equation were obtained for several cases of injection strength. In a moderate flow rate of injection, the mass transfer occurs through the boundary layers but, as the flow rate increases, the inner region far from the container walls takes part in mass transfer.

침식연소가 방지되는 사출용 다발 원통형 그레인 가스발생기 개발 (Development of a Ejection Gas Generator for Precluding Erosive Burning by Using Bundle Cylindrical Grains)

  • 오석진;차홍석;장승교
    • 한국추진공학회지
    • /
    • 제16권3호
    • /
    • pp.69-76
    • /
    • 2012
  • 본 논문에는 유도탄 사출시스템의 사출성능 향상을 위해 침식연소 현상이 발생하지 않는 상태에서 가스발생기의 압력 기울기를 증가시키는 방법에 대해 기술하였다. 안정연소를 얻기 위해 그레인에 반경방향홀을 뚫는 방법과 그레인의 길이대 직경비를 줄이는 방법을 고안하여 이를 적용, 연소시험을 실시하였다. 시험결과 반경방향홀 그레인을 적용했을 경우 침식연소 방지효과는 좋았으나 사출성능을 저하시키는 쪽으로 성능이 변화하였다. 반면에, 다열형 그레인을 적용시 침식연소 방지효과와 함께 사출성능을 향상시키는데 유용한 것으로 나타났다.

침식연소가 방지되는 사출용 다발 원통형 그레인 가스발생기 개발 (Development of a Ejection Gas Generator for precluding Erosive Burning by using Bundle Cylindrical Grains)

  • 오석진;차홍석;장승교
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.432-439
    • /
    • 2011
  • 본 논문에는 유도탄 사출시스템의 사출성능 향상을 위해 침식연소 현상이 발생하지 않는 상태에서 가스발생기의 압력 기울기를 증가시키는 방법에 대해 기술하였다. 안정연소를 얻기 위해 그레인에 반경방향홀을 뚫는 방법과 그레인의 길이대 직경비를 줄이는 방법을 고안하여 이를 적용, 연소시험을 실시하였다. 시험결과 반경방향홀 그레인을 적용했을 경우 침식연소 방지효과는 좋았으나 사출성능을 저하시키는 쪽으로 성능이 변화하였다. 반면에, 다열형 그레인을 적용시 침식연소 방지효과와 함께 사출성능을 향상시키는데 유용한 것으로 나타났다.

  • PDF

Green Body Behaviour of High Velocity Pressed Metal Powder

  • Jonsen, P.;Haggblad, H.A.;Troive, L.;Furuberg, J.;Allroth, S.;Skoglund, P.
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.22-23
    • /
    • 2006
  • High velocity compaction (HVC) is a production technique with capacity to significantly improve the mechanical properties of powder metallurgy (PM) parts. Investigated here are green body data such as density, tensile strength, radial springback, ejection force and surface flatness. Comparisons are performed with conventional compaction using the same pressing conditions. Cylindrical samples of a pre-alloyed water atomized iron powder are used in this experimental investigation. The HVC process in this study resulted in a better compressibility curve and lower ejection force compared to conventional quasi static pressing. Vertical scanning interferometry measurements show that the HVC process gives flatter sample surfaces.

  • PDF

Highly progressive 성능을 위한 다발 원통형 그레인 가스발생기 개발 (Development of a gas generator to obtain highly progressive performance using bundle cylindrical grains)

  • 오석진;차홍석;이응조
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.141-144
    • /
    • 2009
  • 본 논문에는 사출시스템의 성능향상을 위해 불안정 연소 현상이 발생하지 않는 상태에서 가스발생기 압력의 기울기를 증가시키는 방법에 대해 기술되어있다. 안정연소를 얻기 위해 그레인에 반경방향홀을 뚫는 방법 이외에 그레인의 세장비를 줄이는 방법을 제안하였다. 제안된 방법을 적용하여 가스발생기를 제작, 시험한 결과 기준모델과 비교시 유사한 수준의 사출종말속도에서 최대가속도를 최대 33% 줄일 수 있음을 확인하였다.

  • PDF

심장 자기공명영상에서 방사형 임계치 결정법을 통한 좌심실 분할 알고리즘 (Left Ventricle Segmentation Algorithm through Radial Threshold Determination on Cardiac MRI)

  • 문창배;이해연;김병만;신윤식
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제36권10호
    • /
    • pp.825-835
    • /
    • 2009
  • 의학기술이 발전하면서 결핵, 폐렴, 영양실조, A형간염 등의 질병에 의한 사망률은 감소하는 반면, 심장 질환으로 인한 사망률은 증가하는 추세이다. 심장병을 예방하기 위하여 정기적인 검사가 중요하고, 인체에 무해한 자기공명영상을 활용하여 심장의 혈류량과 심박구출률을 계산하여 심장의 기능을 분석할 필요가 있다. 본 논문에서는 기존의 노동집약적이고 시간적 비용이 큰 수동윤곽분할을 대체하기 위한 자동 좌심실 분할 알고리즘을 제안하였다. 방사형 임계치 결정법을 통하여 심실을 분할하고 혈류량 및 심박구출률을 계산하였으며, 특히 기존 방법들에서 문제가 되었던 기저 영상도 사용자 간섭률을 최소화하여 자동분할을 수행하였다. 제안 알고리즘의 검증을 위하여 36명의 심장 자기공명영상 데이터를 사용하여 전문가에 의한 수동윤곽분할 및 제너럴일렉트로닉스 MASS 소프트웨어와 정량적 비교를 수행하였다. 실험을 통해 제안한 방법이 표준으로 간주되는 수동윤곽분할과 정확도가 유사하며, MASS 소프트웨어보다 높은 정확도를 갖고 있음을 알 수 있었다.

Right Ventricular Strain Is Associated With Increased Length of Stay After Tetralogy of Fallot Repair

  • Ranjini Srinivasan;Jennifer A. Faerber;Grace DeCost;Xuemei Zhang;Michael DiLorenzo;Elizabeth Goldmuntz;Mark Fogel;Laura Mercer-Rosa
    • Journal of Cardiovascular Imaging
    • /
    • 제30권1호
    • /
    • pp.50-58
    • /
    • 2022
  • BACKGROUND: Little is known regarding right ventricular (RV) remodeling immediately after Tetralogy of Fallot (TOF) repair. We sought to describe myocardial deformation by cardiac magnetic resonance imaging (CMR) after TOF repair and investigate associations between these parameters and early post-operative outcomes. METHODS: Fifteen infants underwent CMR without sedation as part of a prospective pilot study after undergoing complete TOF repair, prior to hospital discharge. RV deformation (strain) was measured using tissue tracking, in addition to RV ejection fraction (EF), volumes, and pulmonary regurgitant fraction. Pearson correlation coefficients were used to determine associations between both strain and CMR measures/clinical outcomes. RESULTS: Most patients were male (11/15, 73%), with median age at TOF repair 53 days (interquartile range, 13,131). Most patients had pulmonary stenosis (vs. atresia) (11/15, 73%) and 7 (47%) received a transannular patch as part of their repair. RV function was overall preserved with mean RV EF of 62% (standard deviation [SD], 9.8). Peak radial and longitudinal strain were overall diminished (mean ± SD, 33.80 ± 18.30% and -15.50 ± 6.40%, respectively). Longer hospital length of stay after TOF repair was associated with worse RV peak radial ventricular strain (correlation coefficient (r), -0.54; p = 0.04). Greater pulmonary regurgitant fraction was associated with shorter time to peak radial RV strain (r = -0.55, p = 0.03). CONCLUSIONS: In this small study, our findings suggest presence of early decrease in RV strain after TOF repair and its association with hospital stay when changes in EF and RV size are not yet apparent.

KINEMATIC OSCILLATIONS OF POST-CME BLOBS DETECTED BY K-COR ON 2017 SEPTEMBER 10

  • Lee, Jae-Ok;Cho, Kyung-Suk;Nakariakov, Valery M.;Lee, Harim;Kim, Rok-Soon;Jang, Soojeong;Yang, Heesu;Kim, Sujin;Kim, Yeon-Han
    • 천문학회지
    • /
    • 제54권2호
    • /
    • pp.61-70
    • /
    • 2021
  • We investigate 20 post-coronal mass ejection (CME) blobs formed in the post-CME current sheet (CS) that were observed by K-Cor on 2017 September 10. By visual inspection of the trajectories and projected speed variations of each blob, we find that all blobs except one show irregular "zigzag" trajectories resembling transverse oscillatory motions along the CS, and have at least one oscillatory pattern in their instantaneous radial speeds. Their oscillation periods are ranging from 30 to 91 s and their speed amplitudes from 128 to 902 km s-1. Among 19 blobs, 10 blobs have experienced at least two cycles of radial speed oscillations with different speed amplitudes and periods, while 9 blobs undergo one oscillation cycle. To examine whether or not the apparent speed oscillations can be explained by vortex shedding, we estimate the quantitative parameter of vortex shedding, the Strouhal number, by using the observed lateral widths, linear speeds, and oscillation periods of the blobs. We then compare our estimates with theoretical and experimental results from MHD simulations and fluid dynamic experiments. We find that the observed Strouhal numbers range from 0.2 to 2.1, consistent with those (0.15-3.0) from fluid dynamic experiments of bluff spheres, while they are higher than those (0.15-0.25) from MHD simulations of cylindrical shapes. We thus find that blobs formed in a post-CME CS undergo kinematic oscillations caused by fluid dynamic vortex shedding. The vortex shedding is driven by the interaction of the outward-moving blob having a bluff spherical shape with the background plasma in the post-CME CS.

관상동맥조영술에 사용된 요골동맥의 우회도관으로서의 적합성에 대한 분석 (Analysis of Suitability of Radial Artery Graft as Bypass Conduit after Transradial Catheterization)

  • 신윤철;이동석;지현근;김응중
    • Journal of Chest Surgery
    • /
    • 제37권11호
    • /
    • pp.897-902
    • /
    • 2004
  • 배경: 관상동맥조영술 또는 중재술에 사용된 요골동맥을 관상동맥우회술시 우회도관으로 사용하는 경우가 늘고 있으나 이로 인한 요골동맥도관의 개존성 및 환자의 임상성적에 미치는 영향에 대해 체계적인 연구는 보고되고 있지 않다. 이에 본 저자들은 관상동맥조영술에 사용된 요골동맥을 우회도 관으로 사용한 환자들의 임상성적과 술 후 개존도를 그렇지 않은 환자들과 비교 분석하고자 하였다. 대상 및 방법: 2000년 1월 부터 2004년 2월까지 관상동맥조영술에 사용된 요골동맥을 동맥도관으로 사용한 49예를 I군으로, 관상동맥조영술에 산이지 않은 요골동맥을 동맥도관으로 사용한 44예를 II군으로 정하여 두 군간에 성비, 나이, 술 전 위험인자, 과거력, 임상진단, 수술방법, 수술성적, 우회도관의 개존도 등을 후향적으로 비교 분석하였다. 결과: 두 군 간 남녀비, 연령, 진단명, 수술 위험인자, 심박출률 등의 유의한 차이는 없었다. 술 전 관상동맥조영술은 I군에서는 전예에서 좌측 요골동맥을 이용하였고 II군에서는 대퇴동맥 혹은 우측 요골동맥을 이용하였다. 수술은 전예에서 인공심폐기를 이용한 관상동맥우회술을 시행하였으며 수술사망은 양군에서 모두 없었고 주요합병증은 I군은 5예(10%), II군은 3예(7%) 있었다. 수술에 이용된 우회도관으로는 양군에서 내흉동맥, 요골동맥, 대복재 정맥을 주로 이용하였고 I군은 환자당 평균 3.7$\pm$1.1원위부문합, II군은 3.7$\pm$0.9원위부문합을 시행하였고 요골동맥절편은 I군에서 환자당 평균 1.2$\pm$0.4원위부문합, II군에서 1.3$\pm$0.5원위부문합을 시행하였다. 요골동맥의 원위부문합은 양 군에서 회선지 부위가 가장 많았고 근위부문합은 두군에서 모두 상행대동맥, 내흉동맥, 대복재정맥 후드 순이었다. 수술 후 관상동맥조영술상 양군에서 내흉동맥과 요골동맥은 모두 100%의 개존도를 보였으며 대복재정맥은 I군 85%, II군 86%의 개존도를 보였다. 요골동맥절편에서 완전개존이 I군에서 93%로 II군의 81%보다 오히려 높게 나왔으나 유의하지는 않았다. 결론: 술 후 시행한 관상동맥조영술에서 양군에 개존율에 큰 차이는 없었으며 수술 전 관상동맥 조영술에 사용된 요골동맥도 비교적 안전하게 관상동맥우회술의 우회도관으로 사용할 수 있다고 판단된다.

측정 자세 및 상완 혈압에 의한 맥파 특성 변화 (Change of arterial pulse wave characteristic by measurement posture and brachial blood pressure)

  • 남기창;김은근;허현;허영
    • 감성과학
    • /
    • 제12권3호
    • /
    • pp.299-306
    • /
    • 2009
  • 본 연구에서는 비침습적으로 압력 맥파를 검출하는 토노메트리 방식의 맥파 측정 장비인 SphygmoCor(AtCor, Australia)를 사용하여 측정자세에 따라 맥파를 측정하였다. 측정 결과를 통해 선 자세, 앉은 자세, 누운 자세에 따른 맥파의 분석 지표들의 변화를 분석하였다. 또한 측정된 데이터를 저혈압군, 정상혈압군, 고혈압군으로 구분하여 혈압군에 따른 맥파의 비교를 수행하였다. 그 결과 자세에 따른 요골동맥의 파형에서 유의차를 보인 분석지표는 맥파의 진폭에 해당되는 압력 보다 주요 피크가 발생되는 시간에서 나타났다. 맥압의 경우 맥파증대계수(AI)나 중심동맥압과 요골동맥압의 비율과 같이 맥압 간의 비율이 자세에 따른 변별력이 있었다. 사후검정에 따라 각 자세별로 상호 간에 모두 유의한 차이를 보인 분석지표는 주파(P_$T_1$)와 반사파(P_$T_2$)의 시간, 심박출지속시간(ED), 심박수(HR)로 나타났다. 혈압군에 대한 비교에서 대부분 맥파의 시간에 해당되는 지표보다 주요 피크의 진폭에 해당되는 맥파의 압력을 나타내는 지표가 혈압군에 따른 유의차를 보였다.

  • PDF