• Title/Summary/Keyword: Radial Distribution System

Search Result 238, Processing Time 0.025 seconds

A study of communication-based protection coordination for networked distribution system (네트워크 배전계통용 통신기반 보호협조에 관한 연구)

  • Kim, WooHyun;Chae, WooKyu;Hwang, SungWook;Lee, HakJu
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.1
    • /
    • pp.43-48
    • /
    • 2022
  • Although the distribution system has been structured as complicated as a mesh in the past, the connection points for each line are always kept open, so that it is operated as a radial distribution system (RDS). For RDS, the line utilization rate is determined according to the maximum load on the line, and the utilization rate is usually kept low. In addition, when a fault occurs in the RDS, a power outage of about 3 to 5 minutes occurs until the fault section is separated, and the healthy section is transferred to another line. To improve the disadvantages of the RDS, research on the construction of a networked distribution system (NDS) that linking multiple lines is in progress. Compared to the RDS, the NDS has advantages such as increased facility utilization, load leveling, self-healing, increased capacity connected to distributed generator, and resolution of terminal voltage drop. However, when a fault occurs in the network distribution system, fault current can flow in from all connected lines, and the direction of fault current varies depending on the fault point, so a high-precision fault current direction determination method and high-speed communication are required. Therefore, in this paper, we propose an accurate fault current direction determination method by comparing the peak value polarity of the fault current in the event of a fault, and a communication-based protection coordination method using this method.

Parallel Genetic Algorithm-Tabu Search Using PC Cluster System for Optimal Reconfiguration of Distribution Systems (배전계통 최적 재구성 문제에 PC 클러스터 시스템을 이용한 병렬 유전 알고리즘-타부 탐색법 구현)

  • Mun Kyeong-Jun;Song Myoung-Kee;Kim Hyung-Su;Kim Chul-Hong;Park June Ho;Lee Hwa-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.10
    • /
    • pp.556-564
    • /
    • 2004
  • This paper presents an application of parallel Genetic Algorithm-Tabu Search(GA-TS) algorithm to search an optimal solution of a reconfiguration in distribution system. The aim of the reconfiguration of distribution systems is to determine switch position to be opened for loss minimization in the radial distribution systems, which is a discrete optimization problem. This problem has many constraints and very difficult to solve the optimal switch position because it has many local minima. This paper develops parallel GA-TS algorithm for reconfiguration of distribution systems. In parallel GA-TS, GA operators are executed for each processor. To prevent solution of low fitness from appearing in the next generation, strings below the average fitness are saved in the tabu list. If best fitness of the GA is not changed for several generations, TS operators are executed for the upper 10% of the population to enhance the local searching capabilities. With migration operation, best string of each node is transferred to the neighboring node aster predetermined iterations are executed. For parallel computing, we developed a PC-cluster system consisting of 8 PCs. Each PC employs the 2 GHz Pentium Ⅳ CPU and is connected with others through ethernet switch based fast ethernet. To show the usefulness of the proposed method, developed algorithm has been tested and compared on a distribution systems in the reference paper. From the simulation results, we can find that the proposed algorithm is efficient and robust for the reconfiguration of distribution system in terms of the solution qualify. speedup. efficiency and computation time.

Parallel Genetic Algorithm-Tabu Search Using PC Cluster System for Optimal Reconfiguration of Distribution Systems

  • Mun Kyeong-Jun;Lee Hwa-Seok;Park June-Ho
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.2
    • /
    • pp.116-124
    • /
    • 2005
  • This paper presents an application of the parallel Genetic Algorithm-Tabu Search (GA- TS) algorithm, and that is to search for an optimal solution of a reconfiguration in distribution systems. The aim of the reconfiguration of distribution systems is to determine the appropriate switch position to be opened for loss minimization in radial distribution systems, which is a discrete optimization problem. This problem has many constraints and it is very difficult to solve the optimal switch position because of its numerous local minima. This paper develops a parallel GA- TS algorithm for the reconfiguration of distribution systems. In parallel GA-TS, GA operators are executed for each processor. To prevent solution of low fitness from appearing in the next generation, strings below the average fitness are saved in the tabu list. If best fitness of the GA is not changed for several generations, TS operators are executed for the upper 10$\%$ of the population to enhance the local searching capabilities. With migration operation, the best string of each node is transferred to the neighboring node after predetermined iterations are executed. For parallel computing, we developed a PC-cluster system consisting of 8 PCs. Each PC employs the 2 GHz Pentium IV CPU and is connected with others through switch based rapid Ethernet. To demonstrate the usefulness of the proposed method, the developed algorithm was tested and is compared to a distribution system in the reference paper From the simulation results, we can find that the proposed algorithm is efficient and robust for the reconfiguration of distribution system in terms of the solution quality, speedup, efficiency, and computation time.

The Fault Distance Computation Method for Fault Location Identification of Distribution System (배전계통 고장위치 확인을 위한 고장점 표정기법)

  • Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.3 no.4
    • /
    • pp.276-281
    • /
    • 2008
  • Because the distribution systems experience frequently the fault by several causes, the identification task of fault location plays very important role in the view point of power supply reliability. The distribution systems are designed as radial structure with three-phase and single-phase branch line to supply the electric power to the widely dispersed loads, and it have a several load taps within each line segment. it makes the accurate fault distance determination difficult. Accordingly in this papers, the existing fault point determination methods are surveyed and analyzed, and then a fault distance determination method for distribution feeder is adopted which can be executed effectively in DAS center. Finally, the adopted method is verified using EMTP simulation.

  • PDF

The Effect of Flow Distribution on Transient Thermal Behaviour of CDPF during Regeneration (배기의 유속분포가 CDPF의 재생 시 비정상적 열적 거동에 미치는 영향)

  • Jeong, Soo-Jin;Lee, Jeom-Joo;Choi, Chang-Ho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.2
    • /
    • pp.10-19
    • /
    • 2009
  • The working of diesel particulate filters(DPF) needs to periodically burn soot that has been accumulated during loading of the DPF. The prediction of the relation between an uniformity of gas velocity and soot regeneration efficiency with simulations helps to make design decisions and to shorten the development process. This work presents a comprehensive combined 'DOC+CDPF' model approach. All relevant behaviors of flow fluid are studied in a 3D model. The obtained flow fields in the front of DPF is used for 1D simulation for the prediction of the thermal behavior and regeneration efficiency of CDPF. Validation of the present simulation are performed for the axial and radial direction temperature profile and shows goods agreement with experimental data. The coupled simulation of 3D and 1D shows their impact on the overall regeneration efficiency. It is found that the flow non-uniformity may cause severe radial temperature gradient, resulting in degrading regeneration efficiency.

An Experimental Study on the Flame Structure of Partially Premixed Flame using OH PLIF (OH PLIF를 이용한 부분 예혼합 화염의 화염구조에 관한 실험적 연구)

  • Lee, Seung-Young;Lee, Jong-Ho;Jeon, Chung-Hwan;Chang, Young-June
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.54-59
    • /
    • 2001
  • OH radical concentration have been measured in a methane-air partially premixed flames using PLIF. Excitation lines were selected $Q_{1}(6)$ branch, (1,0) band. The system is consisted of Nd:YAG laser, dye laser and frequency doubler to make pump beam for OH radical. On the direct photographs, flame height increases as fuel flow rate and equivalence ratio increase. And on the PLIF images, OH radical is distributed from premixed flame front to nonpremixed flame front through the flame structure with all equivalence ratio. OH overall concentrations increase with equivalence ratio. At the stoichiometric equivalence ratio, the peak of OH radical concentration exists strongly near the inner cone. As equivalence ratio is changed to richer, OH radical distribution goes thinly and the peak is increased as longitudinal direction. As the flow goes to the downstream, OH radical concentration decreases and broadens, because OH radical reacts with another species after OH formation at the initial oxidization. This phenomenon resembles radial distribution. At the l00cc fuel flowrate, the radial peak of OH radical exists from x/R=l.0 to 1.5.

  • PDF

Microstructure and shear modulus in concentrated dispersions of bidisperse charged spherical colloids

  • Chun, Myung-Suk;Lee, Sangwoo;Lee, Tae-Seok;Cho, Jae-Seol
    • Korea-Australia Rheology Journal
    • /
    • v.16 no.1
    • /
    • pp.17-26
    • /
    • 2004
  • We examine rigorous computations on microstructural as well as rheological properties of concentrated dispersions of bidisperse colloids. The NVT Monte Carlo simulation is applied to obtain the radial distribution function for the concentrated system. The long-range electrostatic interactions between dissimilar spherical colloids are determined using the singularity method, which provides explicit solutions to the linearized electrostatic field. The increasing trend of osmotic pressure with increasing total particle concentration is reduced as the concentration ratio between large and small particles is increased. From the estimation of total structure factor, we observe the strong correlations developed between dissimilar spheres. As the particle concentration increases at a given ionic strength, the magnitude of the first peak in structure factors increases and also moves to higher wave number values. The increase of electrostatic interaction between same charged particles caused by the Debye screening effect provides an increase in both the osmotic pressure and the shear modulus. The higher volume fraction ratio providing larger interparticle spacing yields decreasing high frequency limit of the shear modulus, due to decreasing the particle interaction energy.

A Study on the STATCOM Application for Efficient Operations of Wind Farm (풍력발전단지의 효율적인 운전을 위한 STATCOM 적용 가능성 연구)

  • 장성일;최정환;박인기;황혜미;최돈만;김광호;유능수
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.5
    • /
    • pp.250-256
    • /
    • 2003
  • In this papur, the STATCOM (STATic synchronous COMpensator) application for efficient operations of wind farm is described. The wind farm connected with the electric power network is one of good alternative energy sources. However, it would be also highly possible that interconnection of wind farm causes unwanted influences on distribution system operation, protection and control. This paper proposes the STATCOM application for reducing the negative effects from interconnection of wind farm with distribution networks. The simulation results show that STATCOM would be on effective and useful device to resolve the bad influences from wind farm on distribution networks and improve the operational efficiency of wind farm. In the simulation, the radial distribution network of IEEE 13 bus was modeled using PSCAD/EMTDC.

Development of 3 phase Power Flow calculation algorithm in distribution Power Systems using Symmetrical Component (Symmetrical Components를 이용한 배전계통 3상 조류 계산 알고리즘 개발)

  • Choi, J.H.;Jang, S.I.;Kim, K.H.;Park, J.K.;Kim, J.E.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.147-149
    • /
    • 2000
  • This paper describes a power flow method for distribution systems, applying the method of symmetrical component to back/forward sweep method. The proposed algorithm is effective for unbalanced radial distribution system, with process of distributed resource(PQ & PV node), AVR(Auto Voltage Regulator), shunt capacitor. This proposed method compared conventional back/forward sweep method with the using three phase unbalanced distribution systems with 34 nodes.

  • PDF

A fault location algorithm for distribution feeder systems (배전선로 고장점 표정 알고리즘)

  • Lee, D.S.;Jin, B.G.;Lee, S.J.;Kang, S.H.;Choi, M.S.;Ahn, B.S.;Yoon, N.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.251-253
    • /
    • 2001
  • This paper presents a fault location algorithm for distribution feeder systems. Distribution feeders include single phase and three phase laterals. The proposed algorithm achieves a high accuracy by continuously updating voltage and current phasor using the symmetrical components and admittance load model.

  • PDF