• Title/Summary/Keyword: Rad4

Search Result 309, Processing Time 0.033 seconds

Concentrations of Bioavailable Testosterone and Dihydrotestosterone Determined by Luminescence Immunoassay in Serum (혈청내 섬광면역측정법에 의한 활성적 Testosterone과 Dihydrotestosterone의 농도)

  • Yoon, Yong-Dal;Lee, Chang-Joo;Chun, Eun-Hyun;Lee, Joon-Yeong
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.15 no.2
    • /
    • pp.83-92
    • /
    • 1988
  • 혈액에서 생물학적 활성을 나타내는 (bioavailable) steroid hormone은 주로 비결합형(free form)과 알부민 결합형(albumin-bound form)으로 구성된다. 특히 Testosterone (T)과 5 alpha-Dihydrotestosterone (DHT)의 활성적 분획이 전체의 T, DHT 양에 비해 생리적 현상과 보다 잘 일치하는 것으로 알려지고 있다. 본 연구는 섬광면역측정법(Luminescence immunoassay, LIA)으로 혈청내 활성적 T 및 DHT의 농도의 측정에 이용하고져 하였다. 항체는 T- 또는 DHT-3-CMO-BSA를 항원으로 토끼에 면역주사하여 얻었다. 추적자는 T-3-CMO, DHT-3-CMO에 aminobutylethylisoluminol(ABEI)를 부착시켜 사용하였다. 항체중 IgG분획을 Protein-A-Sepharose CL-4B로 분리한 후 Immunobead(Bio-Rad)에 부착시켜 Solid-phase LIA를 실시하였다. 본 연구에서 LIA는 정확도(accuracy), 정밀도(precision), 감도(sensitivity), 교차반응도(specificity)등을 조사하고, 기존의 방사면역측정법(RIA)과 비교하여 만족할만한 결과를 얻었다. 혈청내 T및 DHT의 활성적 분획의 농도를 측정한 결과는 다음과 같았다. T의 경우는 남성에서 T의 전체량의 33% 이상으로 $7.1{\pm}1.5nmol/l$, 여성에서는 26% 이상으로 $0.28{\pm}0.05nmol/l$이었다. DHT의 활성적 분획은 남성의 경우 $601.7{\pm}85.8pmol/l$, 여성의경우 $52.4{\pm}19.9\;pmol/l$이었다. 이상의 결과를 보아 본 연구에서 이용된 LIA는 혈청내 활성적 농도를 측정하기에 충분하다고 사료된다. 또한 이 방법을 이용하여 여성의 Androgenicity 및 남성 정소기능등의 제어방법에 응용될 수 있을 것으로 판단된다.

  • PDF

A femtosecond Cr:LiSAF laser pumped by semiconductor lasers (반도체 레이저 여기 펨토초 Cr:LiSAF 레이저)

  • 박종대
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.5
    • /
    • pp.360-364
    • /
    • 2000
  • We demonstrate self-starting passIve mode locking of a Cr:LiSAF laser, using a SCIDlconduclor Saturable Absorber Mirror (SESAM), Two high-power red semiconductor lasers (Coherent S-67-500C-100-H) of wavelength 667 nm and maximum power of 500 mW were used as pump lasers, The cavity has 10 cm radius-ai-curvature folding minors, two SF 10 prisms, a 99% reflectivity output coupler and a SESAM at dIe focus of a 10 cm radIus-at-curvature mirror. We used the laser crystal in BrewsterBrewster shape with 1 5% $Cr^{+3}$ ion concentration and the length of 6 mm, An X-shaped resonator was used to compensate the astigmatism induced by tile crystal. The structure of the SESAM cOllSists of 30 pmr of $AlAs/Al_{0.15}Ga_{0.85}As$ layer, wi1l1 a 10 nm GaAs quantum well situated in the topmost layer Output spectra were centeled at 833 nm, with 4 nm spectral bandwidth and pulse width was measured to be 220 fs, Output power of 3 mW is obtained at a pump power of 800 mW. 00 mW.

  • PDF

생명공학과 담배 및 다른 작물들의 응용 현황

  • 박성원
    • Proceedings of the Korean Society of Tobacco Science Conference
    • /
    • 2001.05a
    • /
    • pp.72-78
    • /
    • 2001
  • 농업 유전공학 기술은 생산성 향상, 환경보전, 식품의 안정성 및 품질향상에 기여함은 물론 농업의 경쟁력을 높일 수 있는 유일한 대안으로 인식되고 있다. 전 세계적으로 유전자 재조합 작물의 경작지는 2000년 한해동안 지난해 같은 기간에 비해 11% 증가하였으며 이는 1996년 대비 25배 증가하였고, 선진국과 개발도상국은 각각 2%, 51% 1999년 대비 증가하였다. 1983년 유전자 재조합에 의한 식물의 형질전환이 성공한 뒤 종묘업계는 형질전환 종자개발과 보급에 열중하고 있으며 종자시장에 형질전화 품종이 차지하는 비율은 2000년 30억 달러에서 2010년이면 전체의 60%인 200억 달러에 이를 것으로 전망된다. 1995년 제초제 저항성 콩(라운드업레디콩)이 농가에 보급된 이후 2000년 형질전환품종 재배면적이 3990만 ha에 이르렀고 1997년 미국과 캐나다는 옥수수, 대두, 면화, 감자, 유채 등의 형질전환 품종 재배로 각각 3억1400만 달러, 5300만 달러를 벌어들였음. 형질전환 품종의 보급 증가속도는 소비자들의 GMO에 대한 거부반응으로 다소 주춤한 상태이다. 그러나 최근 종자회사들은 생태계 위해성 논란을 피해갈 수 있는 연구로 이러한 상황을 돌파하려 하고 있다. 우리나라에서도 유전자변형 생물체에 관한 법률이 제정되었으며 많은 대학과 연구소에서 형질전환 연구가 꾸준히 이루어지고 있고 최근 제초제 저항성 벼와 바이러스 저항성 감자가 개발돼 GMO 안정성 점검에 들어가 있고, 살충성 배추, 혈압강하 토마토, 지방산 강화 들깨, 병저항성 고추 등도 실험실과 포장에서 재배되고 있다. 이르면 4-5년 뒤 형질전환 작물들이 농가에 보급될 전망이다. 이처럼 체크 툴은 Firewall의 수비능력을 보강하는 위치에 있다고 생각할 수 있다.다. 4 장에서는 3장에서 제기한 각각의 문제점에 대해 RAD 의 관점에 비추어 e-business 시스템의 단기개발을 실현하기 위한 고려사항이나 조건 해결책을 제안한다. 본 논문이 지금부터 e-business 를 시작하려고 하는 분, e-business 시스템의 개발을 시작하려고 하는 분께 단기간의 e-business 실현을 위한 하나의 지침이 된다면 다행이겠다.formable template is used to optimize the matching. Then, clustering the similar shapes by the distance between each centroid, papaya can be completely detected from the background.uage ("Association of research for algorithm of calculating machine (1992)"). As a result, conventional NN and CNN were available for interpolation of sampling data. Moreover, when nonlinear intensity is not so large under the field condition of small slope, interpolation performance of CNN was a little not so better than NN. However, when nonlinear intensity is large under the field condition of

  • PDF

Numerical and Experimental Study on Motion Response of 1MW OTEC Platform (1MW OTEC 구조물의 운동 응답에 대한 수치 및 모형시험 연구)

  • Kwon, Yong-Ju;Nam, Bo Woo;Kim, Namwoo;Jung, Dong-Ho;Hong, Sa Young;Kim, Hyeon-Ju
    • Journal of Ocean Engineering and Technology
    • /
    • v.31 no.2
    • /
    • pp.81-90
    • /
    • 2017
  • The 1MW OTEC (Ocean Thermal Energy Conversion) platform was designed for application in equatorial seas. In this study, the OTEC platform was investigated using numerical and experimental methods. An octagon-shaped OTEC platform was investigated using the Ocean Engineering Basin of KRISO. These experiments included various tests of regular waves, irregular waves and irregular waves with current (wave+current). The responses of the platform in regular waves showed good agreement between the numerical and experimental results, including the motion RAO, wave run up, and mean drift force. The peak period of heave and pitch motions were observed around 0.5 rad/s, and the effect of the total reflection was found under short wave conditions. The standard deviation (STD) of the platform motion was checked in irregular waves of equatorial and Hawaiian seas. The STD of the pitch was less than $4^{\circ}$ different from the operability requirement under equatorial conditions and the surge STD of the wave frequency showed good agreement between the numerical and experimental results. The STD values of the surge and pitch were increased 66.6% and 92.8% by the current effects in irregular waves, but the pitch STD was less than $4^{\circ}$ under equatorial conditions. This study showed that the STD of the surge was affected by spring effects. Thus, the watch circle of the platform and tension of the mooring lines must be evaluated for a specific design in the future.

A design of transmission-type multi-target X-ray tube based on electric field modulation

  • Zhao, Lei;Jia, Wenbao;Jin, Limin;Shan, Qing;Cheng, Can;Zhu, Hongkui;Hei, Daqian
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.3026-3034
    • /
    • 2021
  • Multi-target X-ray tube is a new type X-ray source, and can be applied in many fields such as sensitive X-ray fluorescence analysis and medical imaging. In this work, we report an electric field modulation multi-target X-ray tube, which contains four targets (Cr, Ni, Au, Mo) coated on a Beryllium (Be) window. A four-valve electric field deflector was developed to deflect the electron beam to bombard the corresponding targets. Particle dynamics analysis software was employed to simulate the particle tracking of electron beam. The results show that the 30 keV electron beam could get a 6.7 mm displacement on the target plane by 105 V/m electric field. The focus areas are about 2 mm × 5 mm and 4 mm × 2.5 mm after deflection in two directions. Thermal behavior calculated by ANSYS shows that the designed target assembly could withstand a 10 W continuous power. The optimum target thicknesses and emission spectra were obtained by Geant4 when the thickness of Be window was 300 mm and the electron beam incident angle was 0.141 rad. The results indicate that this multi-target X-ray tube could provide different X-ray sources effectively.

The Preventive Effects of Standardized Extract of Zataria multiflora and Carvacrol on Acetaminophen-Induced Hepatotoxicity in Rat - Zataria multiflora and Carvacrol and Hepatotoxicity -

  • Mohebbati, Reza;Paseban, Maryam;Beheshti, Farimah;Soukhtanloo, Mohammad;Shafei, Mohammad Naser;Rakhshandeh, Hasan;Rad, Abolfazl Khajavi
    • Journal of Pharmacopuncture
    • /
    • v.21 no.4
    • /
    • pp.249-257
    • /
    • 2018
  • Objectives: The hepatotoxicity induced by Acetaminophen (AAP) mostly mediated by effect on oxidative stress parameters. The Zataria multiflora (Z.M) is an herbal medicine with well-known antioxidant effect. The aim of this study is investigation of preventive effects of Z.M and Carvacrol (CAR) on AAP-induced hepatotoxicity in rats. Methods: Rats were randomly divided into four groups including: 1) Control, 2) Acetaminophen (AAP), 3) and 4) CAR. The saline, Z.M (200 mg/kg) and CAR (20 mg/kg) were administrated orally for 6 days, after that AAP (600 mg/kg) was administrated in the $7^{th}$ day. Blood sampling was performed on the first and last days. Also, the liver tissue was removed for evaluation of Malondyaldehide (MDA), Thiol content, Superoxide dismutase (SOD) and Catalase (CAT). Total Protein (tPro), Glutamic Oxaloacetic Transaminase (GOT), Glutamic Pyruvic Transaminase (GPT) and Alkaline Phosphatase (ALP) in liver tissue were evaluated. The changes (${\Delta}$) of enzymes activities were presented. Results: The ${\Delta}GOT$, ${\Delta}GPT$ and ${\Delta}ALP$ in CAR group significantly decreased compared to AAP group (P < 0.01 to P < 0.001) and ${\Delta}GPT$ in Z.M group was significantly reduced in comparison with AAP group (P < 0.05). Also, MDA, Thiol, SOD and CAT levels in treated groups were attenuated compared to AAP group (P < 0.05 to P < 0.001). Conclusion: Z.M and CAR have a powerful hepatoprotective effect. CAR is more effective than Z.M. Based on the results. Z.M and CAR could be potent supplementary agents against hepatotoxicity of AAP in patients.

Beam-Column Connection with 1200mm Deep Multi-Reduced Taper Beam for Intermediate Moment Frame (깊이 1200mm급 변단면보의 중간모멘트골조용 내진접합부 개발)

  • Jung, Si-Hwa;Alemayehe, Robel Wondimu;Park, Man-Woo;Ju, Young-Kyu
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.4
    • /
    • pp.135-146
    • /
    • 2019
  • Deep beam has high section modules compared with shallow beam of the same weight. However, deep beam has low rotational capacity and high possibility of brittle failure so it is not possible to apply deep beams with a long span to intermediate moment frames, which should exhibit a ductility of 0.02rad of a story drift angle of steel moment frames. Accordingly, KBC and AISC limit the beam depth for intermediate and special moment frame to 750mm and 920mm respectively. The purpose of this paper is to improve the seismic performance of intermediate moment frame with 1200mm depth beam. In order to enhance vulnerability of plastic deformation capacity of deeper beam, Multi-Reduced Taper Beam(MRTB) shape that thickness of beam flange is reinforced and at the same time some part of the beam flange width is weakened are proposed. Based on concept of multiple plastic hinge, MRTB is intended to satisfy the rotation requirement for intermediate moment frame by dividing total story drift into each hinge and to prevent the collapse of the main members by inducing local buckling and fracture at the plastic hinge location far away from connection. The seismic performance of MRTB is evaluated by cyclic load test with conventional connections type WUF-W, RBS and Haunch. Some of the proposed MRTB connection satisfies connection requirements for intermediate moment frame and shows improved the seismic performance compared to conventional connections.

Evaluation of Radon Concentration according to Mechanical Ventilation Systems in Apartments (공동주택 내의 기계환기 설비에 따른 라돈농도 평가)

  • Choi, Jiwon;Hong, Hyungjin;Lee, Jeongsub;Yoo, Juhee;Park, Boram;Kim, Gahyun;Yoon, Sungwon;Lee, Cheolmin
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.4
    • /
    • pp.330-338
    • /
    • 2021
  • Background: This study was conducted to provide background information for the proper management of radon contamination in apartments using mechanical ventilation facilities in residential environments. Objectives: To this end, this study compared and evaluated changes in radon concentrations based on different operating intensities of mechanical ventilation with or without natural ventilation. Methods: For the continuous measurement of radon concentrations, an RAD7 instrument was installed in four apartments equipped with a ventilation system. The measurements were done for comparison of ventilation types and different ventilation intensities ("high", "middle", "low"). Results: The results confirmed that both mechanical and natural ventilation sufficiently reduced the radon concentration in the apartments. In particular, mechanical ventilation at "high" intensity was the most effective. Natural ventilation combined with mechanical ventilation and then natural ventilation alone were the second and the third most effective, respectively. Conclusions: When using ventilation to reduce indoor radon concentrations, it is most effective to operate mechanical ventilation ("high") or natural ventilation and mechanical ventilation at the same time. In cases where mechanical ventilation is available alone, it is recommended to operate it at a minimum of "middle" intensity.

A Study on Radio Resource Management for Multi-cell SC-FDMA Systems (다중셀 SC-FDMA를 위한 무선자원 관리기법에 관한연구)

  • Chung, Yong-Joo
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.15 no.4
    • /
    • pp.7-15
    • /
    • 2010
  • This study proposes a rad o resource management scheme to maximize the performance of the LTE(Long Term Evolution) uplink, using SC-FDMA(Single Carrier-Frequency Division Multiple Access). Rather than the single-cell SC-FDMA system the existing studies are mainly concerning, this study focuses on multi-cell system which needs considering the interaction among cells. Radio resource management is divided into two phases, planning and operation phases. The former is for the master eNB(e-NodeB) to allocate RBs(radio bearer) to eNB, the latter for eNB to assign RBs to the mobiles in the cell. For each phase, an optimization model and greedy algorithm are proposed. Optimization models aim to maximize the system performance while satisfying the constraints for both QoS and RB continuity. The greedy algorithms, like generic ones, move from a solution to a neighboring one having the best objective value among neighboring ones. From the numerous numerical experiments, the performance and characteristics of the algorithms are analyzed. This study is expected to play a volunteering role in radio resource management for the multi-cell SC-FDMA system.

The Effect of 131I Therapy by Taking in Laxatives (방사성요오드 치료 시 완하제 투여 효과)

  • Kil, Sang-Hyeong;LEE, Hyo-Yeong;Park, Kwang-Yeol;Jo, Kyung-Nam;Baek, Seung-Jo;Hwang, Kyo-Min;Cho, Seong-Mook;Choi, Jae-Hyeok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.3-9
    • /
    • 2014
  • Purpose: Our goals were to evaluate the effect of high dose radioiodine treatment for thyroid cancer by taking in laxatives. Materials and Methods: Twenty patients(M:F=13:7, age $46.3{\pm}8.1\;yrs$) who underwent high dose radioiodine treatment were seperated into Group 1 taking $^{131}I$ 5,500 MBq and Group 2 with the use of laxatives after taking $^{131}I$ 5,500 MBq. The whole body was scanned 16 hours and 40 hours after taking radioactive iodines by using gamma camera, the ROIs were drawn on the gastro-intestinal tract and thigh for calculation of reduction ratio. At particular time during hospitalization, the radioactivity remaining in the body was measured in 1 meter from patient by using survey meter (RadEye-G10, Thermo Fisher Scientific, USA). Schematic presentation of an Origin 8.5.1 software was used for spatial dose rate. Statistical comparison between groups were done using independent samples t-test. P value less than 0.05 was regarded as statistically significant. Results: The reduction ratio in gastro-intestinal 16 hours and 40 hours after taking laxatives is $42.1{\pm}6.3%$ in Group 1 and $72.1{\pm}6.4%$ in Group 2. The spatial dose rate measured when discharging from hospital was $23.8{\pm}6.7{\mu}Sv/h$ in Group 1 and $8.2{\pm}2.4{\mu}Sv/h$ in Group 2. The radioactivity remaining in the body is much decreased at the patient with laxatives(P<0.05). Conclusion: The use in combination with laxatives is helpful for decreasing radioactivity remaining in the body. The radioactive contamination could be decreased at marginal individuals from patients.

  • PDF