• 제목/요약/키워드: Rad27

Search Result 47, Processing Time 0.027 seconds

MONITORING OF GAMMA-RAY BRIGHT AGN: THE MULTI-FREQUENCY POLARIZATION OF THE FLARING BLAZAR 3C 279

  • KANG, SINCHEOL;LEE, SANG-SUNG;BYUN, DO-YOUNG
    • Journal of The Korean Astronomical Society
    • /
    • v.48 no.5
    • /
    • pp.257-265
    • /
    • 2015
  • We present results of long-term multi-wavelength polarization observations of the powerful blazar 3C 279 after its γ-ray flare on 2013 December 20. We followed up this flare with single-dish polarization observations using two 21-m telescopes of the Korean VLBI Network. Observations carried out weekly from 2013 December 25 to 2015 January 11, at 22 GHz, 43 GHz, 86 GHz simultaneously, as part of the Monitoring Of GAmma-ray Bright AGN (MOGABA) program. We measured 3C 279 total flux densities of 22–34 Jy at 22 GHz, 15–28 Jy (43 GHz), and 10–21 Jy (86 GHz), showing mild variability of ≤ 50 % over the period of our observations. The spectral index between 22 GHz and 86 GHz ranged from −0.13 to −0.36. Linear polarization angles were 27°–38°, 30°–42°, and 33°–50° at 22 GHz, 43 GHz, and 86 GHz, respectively. The degree of linear polarization was in the range of 6–12 %, and slightly decreased with time at all frequencies. We investigated Faraday rotation and depolarization of the polarized emission at 22–86 GHz, and found Faraday rotation measures (RM) of −300 to −1200 rad m−2 between 22 GHz and 43 GHz, and −800 to −5100 rad m−2 between 43 GHz and 86 GHz. The RM values follow a power law with a mean power law index a of 2.2, implying that the polarized emission at these frequencies travels through a Faraday screen in or near the jet. We conclude that the regions emitting polarized radio emission may be different from the region responsible for the 2013 December γ-ray flare and are maintained by the dominant magnetic field perpendicular to the direction of the radio jet at milliarcsecond scales.

Performance Evaluation of Inelastic Rotation Capacity of Reinforced Concrete Beam-Column Connections (철근콘크리트 보-기둥 접합부의 비탄성 회전 능력에 대한 성능 평가)

  • Lee, Ki-Hak;Woo, Sung-Woo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.5
    • /
    • pp.1-9
    • /
    • 2007
  • This study summarizes the results of a research project aimed at investigating the inelastic rotation capacity of beam-column connections of reinforced concrete moment frames. A total of 91 test specimens for beam-column joint connections were examined in detail, and 28 specimens were classified as special moment frame connections based on the design and detailing requirements in the ACI 318-02 Provisions. Then the acceptance criteria, originally defined for steel moment frame connections in the AISC-02 Seismic Provisions, were used to evaluate the joint connections of concrete moment frames. Twenty-seven out of 28 test specimens that satisfy the design requirements for special moment frame structures provide sufficient strength and are ductile up to a plastic rotation of 0.03 rad. without any major degradation in strength. Joint shear stress, column-to-beam flexural strength ratio, and transverse reinforcement ratio in a joint all play a key role in good performance of the connections.

Fabrication of FeCuNi alloy by mechanical alloying followed by consolidation using high-pressure torsion

  • Asghari-Rad, Peyman;Kim, Yongju;Nguyen, Nhung Thi-Cam;Kim, Hyoung Seop
    • Journal of Powder Materials
    • /
    • v.27 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • In this research, a new medium-entropy alloy with an equiatomic composition of FeCuNi was designed using a phase diagram (CALPHAD) technique. The FeCuNi MEA was produced from pure iron, copper, and nickel powders through mechanical alloying. The alloy powders were consolidated via a high-pressure torsion process to obtain a rigid bulk specimen. Subsequently, annealing treatment at different conditions was conducted on the four turn HPT-processed specimen. The microstructural analysis indicates that an ultrafine-grained microstructure is achieved after post-HPT annealing, and microstructural evolutions at various stages of processing were consistent with the thermodynamic calculations. The results indicate that the post-HPT-annealed microstructure consists of a dual-phase structure with two FCC phases: one rich in Cu and the other rich in Fe and Ni. The kernel average misorientation value decreases with the increase in the annealing time and temperature, indicating the recovery of HPT-induced dislocations.

Primary Mediastinal Seminoma: A Case Report (원발성 종격동 정상피종: 1례 보고)

  • Lee, In-Sung;Kim, Hyoun-Mook
    • Journal of Chest Surgery
    • /
    • v.11 no.2
    • /
    • pp.170-174
    • /
    • 1978
  • A case of mediastinal seminoma is presented. A male driver, 27 years old Korean, has been suffered from substernal pain, cough and moderate swallowing difficulty since 5 months prior to this admission. At the time of onset, he visited at a local clinic to find some mass in his anterior mediastinum on chest P-A and lateral X-ray check. Recently, intermittent hiccups with much aggravated dysphagia forced him to visit our hospital, and admitted for radical resection under the impression of anterior superior mediastinal tumor of thymus origin. Median sternotomy was done and total resection of the tumor of 8.0X11.0X3.5cm was done without any specific complication and biopsy of the tumor revealed as primary mediastinal seminoma of the mediastinum. Supplementary prophylactic irradiation therapy was done with a tumor dose of 4,000 rad in 4 weeks after operation. Postoperative hospital course was uneventful and patient was joyful with his occupation for 3 months after discharge.

  • PDF

Radiologic projections for avusion fractures of the lateral malleolus (족관절 외과 견연 골절의 새로운 방사선 촬영법)

  • Park Jong Sam;Choi Ga Young;You Kwang Hyun;Choi Ku Seo;Kim Jin Tea;Kim Chang Hwoe;Han Dong Hyun
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.27 no.2
    • /
    • pp.115-123
    • /
    • 2001
  • The two ligaments, the anterior talofibular ligament(ATFL) and the calcaneofibular ligament(CFL), arise from the anteroinferior aspect of the lateral malleolus, and therefore avulsion fragments are superimposed on the lateral malleolus on the srandard rad

  • PDF

Thermodynamic Studies on the Interaction of Copper Ions with Carbonic Anhydrase

  • Sarraf, N.S.;Mamaghani-Rad, S.;Karbassi, F.;Saboury, A. A.
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.7
    • /
    • pp.1051-1056
    • /
    • 2005
  • The interaction of bovine carbonic anhydrase II with copper ions was studied by isothermal titration microcalorimetry, circular dichroism, UV spectrophotometry and temperature scanning spectrophotometry methods at 27 ${^{\circ}C}$ in Tris buffer solution at pH = 7.5. It was indicated that there are three non-identical different binding sites on carbonic anhydrase for $Cu^{2+}$. The binding of copper ions is exothermic and can induce some minor changes in the secondary and tertiary structure of the enzyme, which does not unfold it, but can result in a decrease in both activity and stability of the enzyme.

Radiation Effects on the Power MOSFET for Space Applications

  • Lho, Young-Hwan;Kim, Ki-Yup
    • ETRI Journal
    • /
    • v.27 no.4
    • /
    • pp.449-452
    • /
    • 2005
  • The electrical characteristics of solid state devices such as the bipolar junction transistor (BJT), metal-oxide semiconductor field-effect transistor (MOSFET), and other active devices are altered by impinging photon radiation and temperature in the space environment. In this paper, the threshold voltage, the breakdown voltage, and the on-resistance for two kinds of MOSFETs (200 V and 100 V of $V_{DSS}$) are tested for ${\gamma}-irradiation$ and compared with the electrical specifications under the pre- and post-irradiation low dose rates of 4.97 and 9.55 rad/s as well as at a maximum total dose of 30 krad. In our experiment, the ${\gamma}-radiation$ facility using a low dose, available at Korea Atomic Energy Research Institute (KAERI), has been applied on two commercially available International Rectifier (IR) products, IRFP250 and IRF540.

  • PDF

Estimation of Surplus Solar Energy in Greenhouse (II) (온실내 잉여 태양에너지 산정(II))

  • Suh, Won-Myung;Bae, Yong-Han;Ryou, Young-Sun;Lee, Sung-Hyoun;Kim, Hyeon-Tae;Km, Yong-Ju;Yoon, Yong-Cheol
    • Journal of Bio-Environment Control
    • /
    • v.20 no.2
    • /
    • pp.83-92
    • /
    • 2011
  • This study is about an analysis of surplus solar energy by important greenhouse type using Typical Meteorological Year (TMY) data which was secured in order to provide basic data for designing an optimum thermal storage system to accumulate surplus solar energy generated in greenhouses during the daytime. The 07-auto-1 and 08-auto-1 types showed similar heat budget tendencies regardless of greenhouse types. In other words, the ratios of surplus solar energy were about 20.0~29.0% regardless of greenhouse type. About 54.0~225.0% and 53.0~218.0% of required heating energy will be able to be supplemented respectively according to the greenhouse types. The 07-mono-1 and 07-mono-3 types also showed similar heat budget tendencies regardless of greenhouse types. In other words, the ratios of surplus solar energy were about 20.0~26.0% and 21.0~27.0% respectively by greenhouse type. About 57.0~211.0% and 62.0~228.0% of required heating energy will be able to be supplemented by greenhouse type. Except for Daegwallyeong and Suwon area, other regions can cover heating energy only by surplus solar energy, according to the study.

Effects of Radiation on the Chromosomes in Bone Marrow Cells of the Mouse (방사선(放射線)이 생쥐 골수세포(骨髓細胞)의 염색체(染色體)에 미치는 향영(響影))

  • Kim, Yung-Jin;Kim, Jong-Bong
    • Journal of Radiation Protection and Research
    • /
    • v.10 no.2
    • /
    • pp.137-143
    • /
    • 1985
  • To study the relationships among the frequency of chromosomal aberration induced by radiation, mouse age at the time of exposure and elapsed time after the irradiation, the 40, 150 and 300 day old mice were irradiated by gamma rays to 200 rad of acute whole body doses. The bone marrow chromosomes were observed in 8 experimental groups such as 1, 2, 3, 4, 8, 16, 30, 60 and 90 days after irradiation. In the 40 day old mice the frequencies of cell with chromosomal aberration were 53.0%, 21.5%, 8.4%, 8.4%, 12.0%, 8.0%, 7.0% and 5.0% in 8 experimental groups, in the 150 day old mice 32.5%, 12.1%, 10.5%, 12.8%, 0.03%, 9.7%, 7.0% and 4.2%. The 300 day old mice showed that the frequencies of cells with chromosomal aberration were 27.7%, 13.6%, 9.0%, 9.3%, 13.3%, 14.4%, 7.5% and 9.5% in each experimental group. There were tendencies that the frequencies of cell with chromosomal aberration were higher in the young mice than the old ones within 2 days after the irradiation but in the old mice than the young ones after 4 days.

  • PDF

A Precision Rotational Device using Piezoelectric Elements and Impact Drive Mechanism (압전소자와 충격구동 메커니즘을 이용한 초정밀 회전장치)

  • Ten, Aleksey-Deson;Ryu, Bong-Gon;Jeon, Jong-Up
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.1
    • /
    • pp.49-57
    • /
    • 2010
  • This paper describes the design, construction, and fundamental testing of a precision rotational device that utilizes piezoelectric elements as a source of driving force and impact drive mechanism as a driving principle. A novel device structure is designed and the numerical simulations about the static displacement, stress distribution, and mode shape of the designed structure are performed. A fabricated rotational device has been rotated successfully by applying saw-shaped voltages to the piezoelectric elements. The one-step rotational angle was $0.44{\times}10^{-3}$ rad at the applied voltages of 80V. The angular velocities of the device were revealed to be increased as the driving frequency and voltage were respectively increased and the preload was decreased. The device has a feature that it can be translated as well as rotated. An experimental result shows that the device was translated by ${\pm}4.56{\mu}m$ maximum when the 120V sinusoidal voltages with a phase difference of $180^{\circ}$ were respectively supplied to two piezoelectric elements.