• 제목/요약/키워드: RT storage

검색결과 71건 처리시간 0.034초

감자의 품질안정성에 대한 저장 온.습도의 영향 (Effect of Storage Temperature and Humidity on the Quality Stability of Potatoes)

  • 권중호;변명우
    • 한국식품저장유통학회지
    • /
    • 제2권2호
    • /
    • pp.243-249
    • /
    • 1995
  • Potatoes, Irish cobbler, were subject to quality evaluation from the physiological and physicochemical points of view during storage under different temperatures and relative humidities for 11 months. Quality criteria were sprouting, rotting, weight changes, moisture, total sugar, reducing sugar and vitamin C. Low temperature condition(LT, 2∼4$^{\circ}C$, 80% RH) was enough to preserve Potatoes for 11 months, but it was indicated to be limitations that the increase in reducig sugar as well as sprouting by about 3.3 to 6.7% occurred from the 3rd month of storage. Meanwhile, pit temperature(PT, 3∼15$^{\circ}C$, 75∼85% RH), room temperature(RT, 7∼17$^{\circ}C$, 80∼95% RH) and ambient temperature(AT, 2∼25$^{\circ}C$, 62∼72 RH) were shown infeasible conditions for the storage of potatoes mainly due to the increase In sprouting-rate and subsequent quality-loss after 3 months of storage. Based on the results, it proposed that more economical conditions, ranging 10 to 15$^{\circ}C$ and about 80% RH following sprout inhibition treatment should be used for the long-term storage of potatoes.

  • PDF

미생물에 대한 항균효과를 이용한 한약 전탕팩의 유효기한 연구 (Establishment of the Expiration Date of Herbal Formula Decoction Pouch by Antimicrobial Activities Against Microorganisms)

  • 하혜경;최순용;서창섭;이나리;신현규
    • 대한한의학회지
    • /
    • 제41권2호
    • /
    • pp.1-8
    • /
    • 2020
  • Objectives: To establish the expiration date of herbal decoction pouch, the change in antimicrobial activities was measured according to storage temperature and period. Methods: Five herbal formulas, Gyeji-tang, Jakyakgamcho-tang, Saengmaek-san, Paljung-san, and Dangguisu-san, with antimicrobial activity were selected from 51 herbal formulas commonly used in traditional Korean medical institutions. Five herbal formula decoction pouches were prepared and stored at room temperature (RT) or 4℃ from 0 to 12 weeks to evaluate the antimicrobial activity against Bacillus cereus, Listeria monocytogenes, or Vibrio parahaemolyticus. The antimicrobial activities were evaluated by the disk diffusion method (disk size: 10 mm). Results: The decoction pouches of Gyeji-tang and Jakyakgamcho-tang maintained antimicrobial activity against V. parahaemolyticus from week 0 (14 mm) to week 12 (14 mm) at both temperatures. Saengmaek-san pouch had antimicrobial activities against V. parahaemolyticus and B. cereus from week 0 (19 mm and 20 mm) to week 12 (both 18 mm), respectively. At RT and 4℃, the antimicrobial activity of Paljung-san pouch was maintained week 0 (17 mm) to week 12 (both 13 mm) against B. cereus. Against L. monocytogenes, the antimicrobial activity of Dangguisu-san pouch showed 27 mm at week 0 and 23 mm (RT) and 24 mm (4℃) at week 12, respectively. Conclusion: According to increase of the storage duration, the antimicrobial activities of 5 herbal formula decoction pouches decreased slightly but remained up to 12 weeks. These results can be used as important data to establish the expiration date of herbal formula decoction pouches.

탕약의 실온과 냉장보관 및 기간별 안정성에 대한 실험적 연구 (Stability Study for Herbal Drug According to Storage Conditions and Periods)

  • 손진영;신장우;손창규
    • 대한한의학회지
    • /
    • 제30권2호
    • /
    • pp.127-132
    • /
    • 2009
  • Objectives: This study aimed to investigate the stability of a decoction using three herbal plants and their major components according to the storage conditions and periods. Materials and Methods: A three-herb mixture (1:1:1) of Glycyrrhiza uralensis Fischer, Artemisia capillaris Thunberg, and Poncirus trifoliata Rafinesqui was decocted and kept at room temperature ($25{\pm}2^{\circ}C$) or cold temperature ($4^{\circ}C$) for 0, 2, 4 or 8 weeks in liquid form in a plastic pack under dark conditions. At time points given, they were lyophilized. 200 mg of powdered samples were dissolved in 1 mL of 90% methanol and then applied to a high performance thin layer chromatography (HPTLC) with glycyrrhizin, 6,7-dimethoxycoumarin or poncirin for quantitative or qualitative analysis. Results: There were no gross changes in HPTLC-based compositional band-patterns of the three herbal mixture according to the storage conditions and period. The major components of each herb, glycyrrhizin, 6,7-dimethoxycoumarin and poncirin, showed slight time-dependent reduction in their contents both at room and cold temperature for 8 weeks. Conclusion: We could conclude that the current herbal decoction is generally safe for the stability at both RT or CT for at least 8 weeks. Nevertheless, we proposed that further advanced studies are required for more multiple herbal mixtures and longer storage periods.

  • PDF

SE-9000 자동 혈구계산기에서 EDTA 검체의 보관기간 및 온도가 CBC 및 백혈구 감별계산에 미치는 영향 (The Effect of the Storage Duration and Temperature of EDTA Specimen for CBC and WBC Differential Count in SE-9000 Automated Cell Counter)

  • 홍승복;김종석;신경섭
    • 대한임상검사과학회지
    • /
    • 제38권3호
    • /
    • pp.147-151
    • /
    • 2006
  • Although various automated CBC analyzers with different WBC analytical principles were consequently introduced to clinical laboratory, the specific information concerning the suitability or unsuitability of aging samples is scarce. For this reason, we studied the effect of storage duration and temperature on CBC parameter in SE-9000 (SYSMEX Medical Electronics Co., Ltd., Kobe, Japan), automated CBC analyzer. We tested 32 K3-EDTA specimens with SE-9000 during 72 hours. Specimens were kept at room temperature (RT) and refrigerated and were analyzed at 0 hr, 4 hr, 8 hr, 24 hr, 48 hr and 72 hr after the collection of the specimens. The percentage changes from initial value for each parameters were calculated. Among the CBC parameters, hemoglobin, red blood cell count, mean corpuscular hemoglobin and platelets were stable for the study period at both temperatures. The mean corpuscular volume (MCV), hematocrit (Hct) and red cell distribution (RDW) increased and the mean corpuscular hemoglobin concentration (MCHC) decreased over time at room temperature. These parameters were stable when refrigerated. The leukocyte count was stable during 72hr at RT and when refrigerated. At room temperature, the relative percentages of neutrophils tend to increase, whereas those of lymphocyte and monocytes tend to decrease after 48 hours. When refrigerated, those of neutrophils and monocytes tend to increase, whereas those of lymphocytes tend to decreased over time. CBC parameters of refrigerated specimen were reliable for 72 hr for the exception of differential count from 24 hr but many CBC parameters, such as MCV, Hct, MCHC, RDW and differential count of leukocyte of blood stored at room temperature for 24 hr were unreliable.

  • PDF

대수층 축열 시스템의 열 간섭 모델링 (Thermal Interference Modeling in the Aquifer Thermal Energy Storage Systems)

  • 김종찬;이영민;윤운상;구민호;김영석
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.596-599
    • /
    • 2009
  • 대수층 축열 시스템(ATES)의 효율은 지중에 저장된 열 사이의 간섭에 의해 결정이 되며, 열 간섭에 영향을 미치는 요인들은 시추공 간 이격거리, 대수층의 수리 전도도, 주입/양수량 등이 있다. 따라서 이 연구에서는 지하수-지열 거동 모델링을 통하여 열 간섭이 일어나는 현상과 열 간섭이 시스템 효율에 미치는 영향을 분석하였다. 모델링 결과로부터 이격거리는 작을수록 그리고 대수층의 수리전도도와 주입/양수량은 클수록 열 간섭이 잘 일어나는 것을 확인하였고, 열 간섭 계수가 1일 때는 시스템 효율이 상대적으로 크게 낮아지고, 열 간섭 계수가 1 미만일 때는 변화가 미미한 것을 확인하였다. ATES 를 이용한 냉난방 시스템을 시공 하고 있는 안성 연구지역에 대한 장기 예측 모델링을 수행 하였다. 모델링 결과 이격거리가 80 m 이고, 주입/양수량이 100 $m^3/day$ 일 때, 시스템 가동 7년경과 뒤 여름철과 겨울철에 계산된 시스템 효율은 각각 36 RT 와 31 RT 로 나타났다. 따라서 주입/양수량을 100 $m^3/day$로 했을 때, 냉난방 대상건물의 필요 부하인 20 RT 를 충분히 충족할 수 있을 것으로 판단된다.

  • PDF

삼백초 근경의 저장방법에 따른 품질과 Lignans 함량 변화 (Qualities and Lignans Contents of Saururus chinensis Baill. Rhizome by Storage Methods)

  • 김인재;김민자;남상영;윤태;김홍식;정승근
    • 한국식품저장유통학회지
    • /
    • 제13권3호
    • /
    • pp.279-284
    • /
    • 2006
  • 저장방법에 따른 삼백초 생근경의 품질과 유효성분 함량의 변화를 조사하였다. 감모율과 부패율 및 맹아수는 저장기간이 경과할수록 증가하거나 많았다. 감모정도와 맹아수는 저온저장에서 가장 적었으며, 부패율은 창고 내 흙 충진 저장에서 낮았다. 삼백초 근경의 chromatogram상 각 성분의 머무름시간(RT)은 $18{\sim}36$분대로 saucernetin>sauchinone>manassantin A>saucerneol D>manassantin B의 순으로 나타났다. Lignans의 함량은 저장방법 모두 저장 후 30일에 비해 120일에 낮았으나, 저장방법간에는 차이가 없었고 manassantin B>manassantin A>saucernetin>sauchinone>saucerneol D의 순으로 함량이 높았다.

AKD 에멀션의 안정성 평가 (A Study on Stability of AKD-Emulsion)

  • 권원태;김정희;신종호;박민태
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2002년도 추계학술발표논문집
    • /
    • pp.209-217
    • /
    • 2002
  • Stability deterioration of AKD emulsion was studied with respect of the physical change of emulsion particles and the chemical change of AKD itself. Four kinds of commercial emulsions were kept at RT, 40, 50, and $60^{\circ}C$ water bath, respectively. Viscosity, particle size distribution, and solid contents of the emulsions were measured with storage time. At the same time, by performing NMR and IR spectroscopy analysis of the solvent-extracted AKD from the emulsions, the qualitative and quantitative information about the deformation of the AKD itself were obtained. AKD was gradually hydrolyzed to become dialkylketone and higher storage temperature accelerated destabilization of the AKD emulsions.

  • PDF

X-Ray TDI Camera를 이용한 알루미늄 주강품 검사장치 개발 (Development of Inspection System for Aluminum Castings with X-Ray TDI Camera)

  • 남문호;박성욱;김창호;정찬수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1734-1735
    • /
    • 2011
  • In case of inspection on aluminum castings, traditional RT (Radiographic Testing) method have been utilized for its advantages in interpretation, cost and perpetual storage. But it has disadvantages like time consumption in film processing, low efficiency in storage and environmental pollution. In this thesis, a DRS (Digital Radiography System) utilizing X-Ray TDI Camera (Time Delay and Integration Camera) is developed. Inspections on aluminum castings are performed using the developed Digital Radiography System, DRS and reviewed if newly developed system can substitute for the traditional method.

  • PDF

탈구치 저장 매체로서 치주인대 세포에 미치는 Polydeoxyribonucleotide의 효과에 대한 연구 (Effect of Polydeoxyribonucleotide on Human Periodontal Ligament Cells as a Storage Medium for Avulsed Tooth)

  • 노상태;채용권;이고은;김미선;남옥형;이효설;최성철
    • 대한소아치과학회지
    • /
    • 제50권3호
    • /
    • pp.347-359
    • /
    • 2023
  • 본 연구는 탈구된 치아의 저장 매체로서 polydeoxyribonucleotide (PDRN)의 적합성을 평가하고자 하였다. HBSS와 10, 25, 50, 100 ㎍/mL 농도의 PDRN 용액과 수돗물에 저장된 인간 치주인대 세포의 생존율을 측정하기 위해 Cell Counting Kit-8 assay와 Live/Dead assay를 시행하였다. 또한, PDRN의 항염증 효과를 평가하기 위한 NO 검출 및 qRT-PCR 실험을 진행하였다. 100 ㎍/mL 농도의 PDRN 용액에 저장된 치주인대 세포의 생존율이 다른 용액보다 유의하게 높았다(p < 0.01). 또한, 100 ㎍/mL 농도의 PDRN 용액은 유의하게 NO의 생산을 줄였다(p < 0.0001). 그리고, HBSS 용액에 비하여 50 및 100 ㎍/mL 농도의 PDRN 용액에서 유의하게 tumor necrosis factor α, interleukin (IL)-4, IL-6, 그리고 IL-10의 발현이 낮았다(p < 0.01). 이 연구를 통해 PDRN은 치주인대 세포에 세포 보존 및 항염증 효과를 가진 것으로 밝혀졌다. 이 연구는 효과적인 탈구치 저장매체의 개발을 위한 향후 추가적인 실험의 기반이 될 수 있을 것이라 생각한다.

펄스레이저증착법으로 증착한 Indium Zinc Oxide 박막의 물성 (Properties of Indium Zinc Oxide Thin Films Prepared by Pulsed Laser Deposition)

  • 최학순;정일교;신문수;김헌오;김용수
    • 한국전기전자재료학회논문지
    • /
    • 제24권7호
    • /
    • pp.537-542
    • /
    • 2011
  • Recently, n-InZnO/p-CuO oxide diode has attracted great attention due to possible application for selector device of 3-dimensional cross-point resistive memory structures. To investigate the detailed properties of InZnO (IZO), we have deposited IZO films on the fused quartz substrate using PLD (pulsed laser deposition) method at oxygen pressure of 1~100 mTorr and substrate temperature of RT$\sim600^{\circ}C$. The influence of oxygen pressure and substrate temperature on structural, optical and electrical of IZO films is analyzed using XRD (x-ray diffraction), SEM (scanning electron microscopy), UV-Vis spectrophotometry, spectroscopic ellipsometry (SE) and hall measurements. The XRD results shows that the deposited thin films are polycrystalline over $300^{\circ}C$ of substrate temperature independent of oxygen pressure. The resistivity of films was increased as oxygen pressure and substrate temperature decrease. The thickness and optical constants of the deposited films measured with UV-Vis spectrophotometer were also compared with those of broken SEM and SE results.