• 제목/요약/키워드: RS:X

검색결과 134건 처리시간 0.026초

Synthesis of barium-doped PVC/Bi2WO6 composites for X-ray radiation shielding

  • Gholamzadeh, Leila;Sharghi, Hamed;Aminian, Mohsen Khajeh
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.318-325
    • /
    • 2022
  • In this study, composites containing undoped and barium-doped Bi2WO6:Ba2+were investigated for their shielding against diagnostic X-ray. At first, Bi2WO6 and barium-doped Bi2WO6 were synthesized with different weight percentages of barium oxide through a hydrothermal process. The as-synthesized nanostructures were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS) and Raman spectroscopy (RS). After that, some shields were generated with undoped and barium-doped Bi2WO6:Ba2+ nanostructure particles incorporated into polyvinyl chloride (PVC) polymer with different thicknesses and 15% weight of the nanostructure. Finally, the prepared samples were exposed to an X-ray tube at 40, 80, and 120 kV voltages, 10 mAs and, 44.5 cm SID (i.e. the distance from the X-ray beam source to the specimen). Linear and mass attenuation coefficients were also calculated for different samples. The results indicated that, among the samples, the one with 7.5 mmol barium-doped Bi2WO6 had the most attenuation at the voltage of 40kV, and the attenuation coefficients would increase with an increase in the amount of barium. The samples with 15 and 17.5 mmol barium-doped Bi2WO6 had higher attenuation than the others at 80 and 120 kV. Moreover, the half-value layer (HVL), tenth-value layer (TVL) and 0.25 mm lead equivalent thickness were calculated for all the samples. The lowest HVL value was for the sample with 7.5 mmol barium-doped Bi2WO6. As the result clearly show, an increment in the barium-doping content leads to a decrease in both HVL and TVL. In every three voltages, 0.25 mm lead equivalent thickness of the barium-doped composites (7.5 mmol and 15 mmol) had less than the other composites. The lowest value of 0.25 mm lead equivalent thickness was 7.5 barium-doped in 40 kV voltage and 15 mmol barium-doped in 80 kV and 120 kV voltages. These results were obtained only for 15% weight of the nanostructure.

On the Tensor Product of m-Partition Algebras

  • Kennedy, A. Joseph;Jaish, P.
    • Kyungpook Mathematical Journal
    • /
    • 제61권4호
    • /
    • pp.679-710
    • /
    • 2021
  • We study the tensor product algebra Pk(x1) ⊗ Pk(x2) ⊗ ⋯ ⊗ Pk(xm), where Pk(x) is the partition algebra defined by Jones and Martin. We discuss the centralizer of this algebra and corresponding Schur-Weyl dualities and also index the inequivalent irreducible representations of the algebra Pk(x1) ⊗ Pk(x2) ⊗ ⋯ ⊗ Pk(xm) and compute their dimensions in the semisimple case. In addition, we describe the Bratteli diagrams and branching rules. Along with that, we have also constructed the RS correspondence for the tensor product of m-partition algebras which gives the bijection between the set of tensor product of m-partition diagram of Pk(n1) ⊗ Pk(n2) ⊗ ⋯ ⊗ Pk(nm) and the pairs of m-vacillating tableaux of shape [λ] ∈ Γkm, Γkm = {[λ] = (λ1, λ2, …, λm)|λi ∈ Γk, i ∈ {1, 2, …, m}} where Γk = {λi ⊢ t|0 ≤ t ≤ k}. Also, we provide proof of the identity $(n_1n_2{\cdots}n_m)^k={\sum}_{[{\lambda}]{\in}{\Lambda}^k_{{n_1},{n_2},{\ldots},{n_m}}}$ f[λ]mk[λ] where mk[λ] is the multiplicity of the irreducible representation of $S{_{n_1}}{\times}S{_{n_2}}{\times}....{\times}S{_{n_m}}$ module indexed by ${[{\lambda}]{\in}{\Lambda}^k_{{n_1},{n_2},{\ldots},{n_m}}}$, where f[λ] is the degree of the corresponding representation indexed by ${[{\lambda}]{\in}{\Lambda}^k_{{n_1},{n_2},{\ldots},{n_m}}}$ and ${[{\lambda}]{\in}{\Lambda}^k_{{n_1},{n_2},{\ldots},{n_m}}}=\{[{\lambda}]=({\lambda}_1,{\lambda}_2,{\ldots},{\lambda}_m){\mid}{\lambda}_i{\in}{\Lambda}^k_{n_i},i{\in}\{1,2,{\ldots},m\}\}$ where ${\Lambda}^k_{n_i}=\{{\mu}=({\mu}_1,{\mu}_2,{\ldots},{\mu}_t){\vdash}n_i{\mid}n_i-{\mu}_1{\leq}k\}$.

항공기 전기체 정적구조시험의 반력 분석 (Analysis on Reactions of Full-Scale Airframe Static Structural Test)

  • 심재열
    • 한국항공우주학회지
    • /
    • 제48권3호
    • /
    • pp.195-205
    • /
    • 2020
  • 본 논문은 항공기 전기체 구조시험에서 6개 자유도를 구속하는 자세구속시스템에서 발생하는 반력들 분석에 대해 다루고 있다. 반력에는 시험의 모든 오차(제어오차와 기타시험오차)를 포함하고 있으므로 반력분석을 통한 시험오차를 평가하는 연구가 의미가 있고 이를 위해서는 우선 바른 반력산출이 우선되어야 하고 바른 반력산출이 본 연구의 초점이다. 본 연구에서 반력을 공칭반력(Rn)과 시험오차반력(Rce, Rerr)의 합으로 표시할 것을 제시하였고 초기상태(0%DLL)에서 이미 내포한 시험오차특성과 하중증분에 따라 발생하는 시험오차특성을 구분하기 위해 반력을 초기상태반력과 상대 반력으로 구분하여 분석하였다. 선미익기 전기체 구조시험 데이터를 활용하여 정량적 반력분석 결과 제어오차로 인한 반력(Rce)값은 전 하중레벨에서 크기변화가 크지 않으며, 합성력 크기가 82.8N 이내로 유지되었고, 이는 하중부가 전체널에 대한 제어오차(TMF)가 -30~40N 범위 내에서 큰 변화 없이 유지되기 때문이다. 상대반력분석을 통해 산출된 기타시험오차(Rerr_r)의 합성력 크기는 하중 증분에 따라 증대되며, 그 크기도 Rce_r보다는 매우 크게 증대됨(최대치808N)을 보여주었고 바른 상대반력 산출을 위해서는 시험체 변형을 고려해야 함을 각 성분별(X0, Y0, Z0) Rerr_r 분석을 통해 보였다. 시험체 변형을 고려한 반력산출은 시험체에 가해지는 힘들의 작용점 이동을 산출할 수 있는 시험체 변형특성식을 요구한다는 것을 보였다.

과학기술위성 3호 S-대역 송신기 비행모델 설계, 제작 및 시험 (Design, Implementation and Test of Flight Model of S-Band Transmitter for STSAT-3)

  • 오승한;서규재;이정수;오치욱;박홍영
    • 한국항공우주학회지
    • /
    • 제39권6호
    • /
    • pp.553-558
    • /
    • 2011
  • 본 논문에서는 현재 KAIST 인공위성연구센터(SaTReC)에서 개발 진행 중인 과학기술위성3호(STSAT-3) 위성체의 위성 상태정보 전송을 위한 S-대역 송신기 비행모델 개발 및 시험에 관하여 서술하고 있다. STSAT-3의 통신시스템은 크게 상태정보, 명령 송수신을 위한 통신채널과 임무데이터 전송을 위한 통신채널로 구성되며 상태 정보 및 명령 송수신을 위하여 S-대역을 사용하며 임무데이터 전송용으로 X-대역 주파수를 사용하고 있다. S-대역 송신기(S-band Transmitter, STX)는 기능적으로 변조기, 주파수 합성기, 파워 앰프 및 전력공급기 로 구성되어 제작되었다. 전송데이터 변조 방법으로는 주파수 천이방식(Frequency Shift Keying, FSK)을 사용 하며 위성본체와의 데이터 통신은 표준방식인 RS-422통신 방식을 사용하였다. STSAT-3의 STX는 기능적 모듈화에 근거하여 설계 및 제작 되었으며 1.5W(31.7dBm) 송신 출력에 $1{\times}10^{-5}$ 비트오율(BER) 성능을 만족한다. STX 비행모델은 성능시험, 환경시험(진동시험, 열진공시험)을 성공적으로 마치고 위성체 조립단계에 납품되었다.

Crystallographic analysis of dehydrated fully Tl+-exchanged zeolite Y

  • Lim, Woo Taik;Kwon, Ji Hye;Choi, Sik Young;Kim, Young Hun;Heo, Nam Ho
    • 분석과학
    • /
    • 제18권4호
    • /
    • pp.278-286
    • /
    • 2005
  • The crystal structure of ($Tl_{71}$-Y ($Tl_{71}Si_{121}Al_{71}O_{384}$), ${\alpha}=24.706(3){\AA}$, dehydrated at 653 K and $8{\times}10^{-6}$ torr, has been determined by single-crystal X-ray diffraction techniques in the cubic space group $Fd\bar{3}m$ at 294(1) K. The structure was refined using all intensities to the final error indices (using only the 302 reflection for which $F_{\circ}$ > $4{\sigma}(F_0)$) $R_1=0.0602$ (based on F) and $R_w=0.1744$ (based on $F_2$). The 71 $Tl^+$ ions per unit cell are found at four crystallographically distinct positions. Site I' position in the sodalite cavity opposite D6Rs are each occupied by eighteen $Tl^+$ ions per unit cell; these $Tl^+$ ions are recessed ca. $1.45{\AA}$ into the sodalite cavity from their O(3) plane (Tl-O=2.701(15), $3.163(16){\AA}$ and O-Tl-O=$92.1(4)^{\circ}$). The 23 $T1^+$ ions fill site II in the supercage; these $T1^+$ ions are recessed ca. $1.58{\AA}$ into the supercage from their O(2) plane (Tl-O = 2.850(16), $3.156(16){\AA}$ and O-T1-O = $85.1(5)^{\circ}$). The 19 $Tl^+$ ions lie at site III' in the supercage near a triple 4-ring (Tl-O = 3.10(7), $3.39(5){\AA}$ and O-Tl-O = 47.8(9), $95.3(18)^{\circ}$) and the remaining II ions occupy another site III' near a triple 4-ring in the supercage (Tl-O = 2.81(4), $2.71(4){\AA}$ and O-Tl-O = $57.3(8)^{\circ}$).

Numerical analyses of soil-mat foundation and space frame system

  • Daniel Thangaraj, D.;Ilamparuthi, K.
    • Interaction and multiscale mechanics
    • /
    • 제5권3호
    • /
    • pp.267-284
    • /
    • 2012
  • In most of the design offices, analysis of the frame is carried out without considering the effect of the rigidity of mat. The analysis of the superstructure without modelling the foundation properly and conversely analysing the foundation system without considering the stiffness of the superstructure may mislead the estimation of the forces. This paper examines the parameters, which affect the interaction and they are grouped into relative stiffness factors ${\kappa}_{rs}$ and ${\kappa}_{sb}$. An interaction analysis is performed for the five storeyed space frame of 3 bays ${\times}$ 5 bays, using ANSYS finite element code. The soil was treated as an isotropic, homogenous and elastic half space medium and the following conclusions were drawn from the analyses. The differential settlement is reduced due to interaction and the performance of the mat depends on ${\kappa}_{sb}$ values. The moments $M_x$ and $M_y$ in the corner column at all the storey levels are higher in the case of the interaction analysis than in the conventional analysis. The axial forces in the peripheral columns increased and to that extent, the inner column axial loads are reduced. In the beam, more variation is seen in the support moments than in the span moments.

Toward Complete Bacterial Genome Sequencing Through the Combined Use of Multiple Next-Generation Sequencing Platforms

  • Jeong, Haeyoung;Lee, Dae-Hee;Ryu, Choong-Min;Park, Seung-Hwan
    • Journal of Microbiology and Biotechnology
    • /
    • 제26권1호
    • /
    • pp.207-212
    • /
    • 2016
  • PacBio's long-read sequencing technologies can be successfully used for a complete bacterial genome assembly using recently developed non-hybrid assemblers in the absence of second-generation, high-quality short reads. However, standardized procedures that take into account multiple pre-existing second-generation sequencing platforms are scarce. In addition to Illumina HiSeq and Ion Torrent PGM-based genome sequencing results derived from previous studies, we generated further sequencing data, including from the PacBio RS II platform, and applied various bioinformatics tools to obtain complete genome assemblies for five bacterial strains. Our approach revealed that the hierarchical genome assembly process (HGAP) non-hybrid assembler resulted in nearly complete assemblies at a moderate coverage of ~75x, but that different versions produced non-compatible results requiring post processing. The other two platforms further improved the PacBio assembly through scaffolding and a final error correction.

아동이 인지하는 사회적 지지에 관한 연구 - 정상아와 지체부자유아를 대상으로 - (A Study of the Social Support Perceived by Children -Physically Handicapped and Non-physically Handicapped-)

  • 심미경
    • 대한간호학회지
    • /
    • 제17권1호
    • /
    • pp.79-87
    • /
    • 1987
  • Study was to identify the structural and functional characteristics of social support system to better provide social support to physically handicapped children. The research design was a comparative descriptive study and the data were obtained by use of interview and questionnaire. The result of this were as follows: 1. The physically handicapped children perceived that they had a fewer number of social support providers than the non-handicapped children. (t= -4.62, p<.001) 2. The physically handicapped children Perceived a lower level of social support than the non-handicapped children. (t= -3.93, p<.001) In the cases of 3 types of social support (social integration, attachment / intimacy, assistance/guidance), the handicapped children perceived a lower level of social support. 3. It was found that physically handicapped children and nonhandicapped children perceived degree of social support differently (x$^2$=72.08, p<.001). and also the two groups perceived in all types of social support differently. 4. The results of this study showed that parents, school mates, school teachers, brothers and sisters were significant providers of social support and between the two groups the supportive source ranked consistently. (rs=.83, p<.01) 5. The relationship between sociability and the support level was a positive correlation (r=.28, p<.01), the relationship between sociability and the size of the support network showed a positive correlation. (r=.47, p<.01) And with the increase in the number of friends. the number of support providers increased. (F= 4.46, p<.05).

  • PDF

동맥관개존증의 임상적 고찰 (A Clinical Study of Patent Ductus Arteriosus)

  • 이형렬
    • Journal of Chest Surgery
    • /
    • 제20권3호
    • /
    • pp.528-535
    • /
    • 1987
  • A clinical study was performed on 164 cases of PDA experienced at the Dept. of Thoracic and Cardiovascular Surgery of Pusan National University Hospital during 6 years from Jan. 1981 to Dec. 1986. It was shown that the PDA was a female-dominant heart disease [male to female ratio, 1:2.8] and two most common symptoms were frequent URI [45.6%] and exertional dyspnea [36.7%]. Continuous machinery murmurs were detected in 143 cases [87.2%], increased pulmonary vascularities [89.0%] and cardiomegalies [63.4%] by chest X-ray. The signs of LVH [43.9%], RVH [3.7%] and BVH [4.9%] were noted on the EKG. Cardiac catheterizations were performed on 67 out of 164 patients and the mean systolic pulmonary artery pressure was 48mmHg [range: 18-131mmHg] and the mean Qp/Qs was 3.1 [range:1.2-8.5] and Rp/Rs below 0.25 was 83.6%. Associated cardiac anomalies were VSD [7.9%], ASD [3.0%], pulmonary valvular stenosis [2.4%] and left persistent SVC [2.4%]. Operative methods were as follows; ligations [145; 88.4%] and divisions [6;3.7%] were performed through the left posterolateral thoracotomies without mortality and the remained cases [13;8.0%] were managed under the cardiopulmonary bypass because of the associated cardiac anomalies. Atelectasis [4.9%] and pneumonia [4.3%] were most frequent postoperative complications and the overall mortality rate was 2.4% [4 out of 164 cases].

  • PDF

유연 힌지를 이용한 초정밀 3자유도 병렬 매니퓰레이터 개발 (Development of 3-DOF Parallel Manipulator Using Flexure Hinge)

  • 신동익;김영수;서승환;한창수;최두선;황경현
    • 한국정밀공학회지
    • /
    • 제26권7호
    • /
    • pp.127-133
    • /
    • 2009
  • We present a $3-{\underline{P}}RS$ compliant parallel manipulator actuated by PZTs. The motion ranges are $400-{\mu}m$ translation to the z-direction and 5.7-mrad rotation about any axis on the x-y plane. A mechanical amplifier whose advantage is approximately 5.5 is designed and integrated with flexure revolute and spherical joints in a monolithic way. We evaluated the performance of the system: kinematic and dynamic characteristics. In kinematic point of view, the flexures play the roles of conventional mechanism but any nonlinearity such as dead-zone and backlash, which make it possible to achieve the steady-state resolution less than $0.1{\mu}m$. The system shows resonance near 86 Hz with high magnitude and, therefore, poor transient response. But the settling is faster when the flexures are strained higher.