• 제목/요약/키워드: ROM data

검색결과 376건 처리시간 0.025초

정상족과 편평족의 Arch Support 사용에 따른 운동역학적 분석 (Biomechanical Analysis of Arch Support Devices on Normal and Low Arch)

  • 박승범;박재영;김경훈
    • 한국운동역학회지
    • /
    • 제20권1호
    • /
    • pp.91-99
    • /
    • 2010
  • The purpose of this study was to the kinetic variables effects from the use of arch support inserts on low-arched people. We selected 10 people for the research and separated them into 2 groups, 5 people for the normal arched group and 5 people for the low arched group. Each group wear shoes which have a 3 step convertible arch support (level 0, level 2, level 5) and we measured their foot pressure and 3D motion analysis data. As a result, we found that the mean pressure at the heel of the low arched group was decreased when using the arch supports. The arch support induced the correct grounding area for the foot and dispersion of foot pressure. 3D motion analysis found that as the height of the arch support was increased, the movement of the Y-axis(inversion-eversion) was increased to relieve the shock to the heel. The arch support insert limited the range of motion(ROM) of the Z-axis(abduction-adduction) of the low arched person's ankle joint and prevented ankle injury caused by the excessive eversion when walking. Low arched people are seen to be easily tired due to the ineffective shock absorption of the knees and abnormal walking motion. In order to improve the problems, a 3 step convertible arch support(level 5) insert would improve the low-arched people's walking ability. In other words, the low arched people should be expected to walk as well as normal arched people when they wear shoes with the arch support insert.

Effects of chronic alcohol consumption on expression levels of APP and Aβ-producing enzymes

  • Kim, Sae-Rom;Jeong, Hye-Young;Yang, Sung-Hee;Choi, Sung-Pil;Seo, Min-Young;Yun, Young-Kwang;Choi, Yu-Ri;Baik, Sang-Ha;Park, Jong-Sung;Gwon, A-Ryeong;Yang, Dong-Kwon;Lee, Chan-Ho;Lee, Sun-Mee;Park, Kye-Won;Jo, Dong-Gyu
    • BMB Reports
    • /
    • 제44권2호
    • /
    • pp.135-139
    • /
    • 2011
  • Chronic alcohol consumption contributes to numerous diseases, including cancers, cardiovascular diseases, and liver cirrhosis. Epidemiological studies have shown that excessive alcohol consumption is a risk factor for dementia. Along this line, Alzheimer's disease (AD) is the most common form of dementia and is caused by the accumulation of amyloid-$\beta$ ($A{\beta}$ plaques in neurons. In this study, we hypothesized that chronic ethanol consumption is associated with pathological processing of APP in AD. To investigate the relationship between chronic alcohol consumption and $A{\beta}$ production, brain samples from rats fed an alcohol liquid diet for 5 weeks were analyzed. We show that the expression levels of APP, BACE1, and immature nicastrin were increased in the cerebellum, hippocampus, and striatum of the alcohol-fed group compared to the control group. Total nicastrin and PS1 levels were induced in the hippocampus of alcohol-fed rats. These data suggest that the altered expression of APP and $A{\beta}$-producing enzymes possibly contributes to the chronic alcohol consumption-mediated pathogenesis of AD.

불균등 Mesh를 사용한 유한차분법에 의한 전자총의 Beam 궤적 Simulation에 관한 연구 (A Study on the Simulation of Beam Trajectory in the Electron-Gun by FDM using the Irregular Mesh)

  • 김남호;정현열;이무용;정기호
    • 한국통신학회논문지
    • /
    • 제16권8호
    • /
    • pp.719-731
    • /
    • 1991
  • 본 논문은 일반형의 개통형전자총의 전자 빔 궤도를 비교적 신속 편리하게 해석할 수 있는 computer simulation의 한 방법을 소개하는 것으로써 전극의 구조와 인가전압등을 입력하면 빔 전류, cutoff 전압, 빔 직경 그리고 궤적도가 출력으로 얻어진다. 계산속도를 증가시키기 위해서 공간전위의 계산에는 전극공간을 여러개로 분할하고 요구되는 정도에 따라서 각기 다른 격자크기를 할당하였으며 유한차분법으로 계산하도록 하였다. 몇 가지의 model을 선정하여 본 방법으로 빔 궤적도를 simulation 시켰는데 그 결과는 전극의 집속기구를 명확하게 제시해줄 수 있었으며 본 방식으로 구해진 빔 전류, cutoff 전압, 빔 직경등은 실지의 측정실험에서 얻어진 결과와 실험오차 내의 정확도로써 잘 일치되었다. 이 방법을 적용하면 설계자로 하여금 실지로 전자관을 제작하지 않고서도 전극의 구조변화에 따른 영향을 정확히 파악 할 수 있는 까닭에 전자총의 설계나 개선작업에 유용하게 적용될 수가 있을 것이다.

  • PDF

Internet망을 이용한 VOD Client에 관한 연구 (Research about VOD Client that use Internal net)

  • 서승범;홍철호;신동욱;김선주;이무재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 A
    • /
    • pp.211-214
    • /
    • 2003
  • 현재 VOD 의 구현 방식은 PC기반을 이용하여 구현되고 있는데 이 VOD를 PC기반이 아닌 Embedded System으로 구현하는 연구를 수행하였다. 이 시스템의 OS는 WindowsCE.net을 이용하였으며, x86코어를 내장한 Sc1200(National사의 Geode제품군)을 CPU로 사용하였고, 메모리는 128 MByte SDRAM을 사용하였다. 그 외에 영상 데이터의 처리를 위하여 Mpeg Decoder를 사용하였고, Internet 망을 이용하기 위한 Ethernet Controller를 이용하였다. 그리고 소프트웨어를 저장하기 위한 저장메모리가 3가지 가 있는데, BIOS를 위한 Boot ROM과 WindowsCE Kernel을 저장하고 있는 Flash Memory, 그리고 나머지 기타 환경을 저장하기위한 Disk On Chip이 3가지가 저장메모리이다. 이 시스템의 영상출력부는 컴포지트(Composite), 컴포넌트(Com ponent), S-Video가 있으며 이들 중 1가지를 선택하여 TV에 연결하여 동작 되도록 하였다. 실제 구현은 시스템 개발에 필요한 BIOS, WinodwsCE.net Porting, DeviceDriver와 동작 확인에 필요한 간단한 Application 제작하였으며, 영상 Play는 WindowsCE.net에 포함되어있는 Window Media Player를 이용하였다. 따라서, 본 논문은 현재 PC에서 구현되고 있는 VOD 서비스의 단점들인 불필요한 마우스와 키보드 조작, PC와 TV의 연결 시 해상도 호환 문제등 을 보완하고자 Embedded System의 형태로 바꾸어 손쉽게 TV와 연결하여 사용할 수 있도록 구현하는데 의의가 있다고 할 수 있다.

  • PDF

웹 로그분석을 이용한 실시간 온라인 마케팅 시스템 설계 및 개발에 관한 연구 (A Study on the Development of Realtime Online Maketing System Using Web Log Analytics)

  • 오재훈;김재훈;김종우
    • 한국전자거래학회지
    • /
    • 제16권3호
    • /
    • pp.249-261
    • /
    • 2011
  • e-Business 시장의 폭발적 성장으로 기존의 오프라인 기업들이 e-Business 시장으로 진입하게 되었으며, 이는 e-Business 시장의 과도한 경쟁을 야기 시켰다. 이에 기업들은 키워드 광고, 이메일 광고, 배너 광고 등의 온라인 마케팅에 대한 투자를 확대하고 있다. 그러나 기존의 온라인 마케팅 방법들은 방문자를 사이트로 유입시키는 데에만 초점을 맞추고 있으며, 방문자들이 사이트로 유입 후 구매로 전환시키기 위한 방법을 제시하지 못함으로써 마케팅의 투자 대비 효과는 점점 감소하고 있다. 본 논문에서는 사이트에 유입된 방문자를 대상으로 전환율을 높임으로써 마케팅의 효과를 높일 수 있는 실시간 온라인 마케팅 시스템 (ROMS: Realtime Online Marketing System)을 제안하고 개발하였다. ROMS는 방문자 행동을 실시간으로 수집하여 방문자 행동을 분석함으로써 방문자의 정보 및 행동을 실시간으로 모니터링 할 수 있으며, 방문자의 컨텍스트 특성에 따라 개인화된 마케팅을 수행할 수 있다.

Genus Hibiscus의 품종에 관한 연구 -1. 한국재래종 및 남방형 양마의 개화와 수정- (Studies on the kenaf variety of Genus Hibiscus -I. The flowering and fertilization of the kenaf variety)

  • 박종문
    • 한국작물학회지
    • /
    • 제2권
    • /
    • pp.50-56
    • /
    • 1964
  • (1) 양마의 개화 및 수정현상을 조사해서 교잡육종에 참고자료를 얻고저 이 실험을 하였다. (2) 양마의 개화시각은 품종에 따라서 현저한 차이가 있으며 따른 것은 오후 11시부터 11시 30분 늦은 것은 오전 9시 30분부터 10시 사이에 개화를 끝냈다. 가장 개화가 빠른 품종은 한국재래종이고 (P.M. 12∼12시 30분, 성화기) 제일 늦은 품종은 미국에서 도입한 Everglades 71(AM6∼6시 30분, 성화기)이며 Guatemala에서 도입한 Guatemala 38F(A.M. 4∼4시 30분, 성화기), Guatemala 2A(A.M. 4시 30분∼5시, 성화기) 미국종과 한국종의 중간정도로 개화하였다. (3) 한국재래종에 있어서는 동일품종에 있어서도 개화초기와 개화종기에 있어서는 개화시각이 다소 상이하였고 후자의 개화시각은 전자보다 늦었다. 이 원인은 주로 기온에 영향되는 것 같았고 온도의 저하에 따라 개화시각도 늦어지는 것 같이 생각되었다. (4) 상마는 개화됨과 동시에 수술의 화사가 신장되고 개약하여 수분이 되며 수분하여 수정이 되는 소요시간은 5∼6시간으로 볼 수 있었다. (5) 품종간 교잡에 있어서 제일 알맞은 교배시각은 각 품종의 개화최성기라고 생각되었다.

  • PDF

인터넷 원거리출판의 응용과 PDF의 인쇄활용에 관한 연구 (A Study on the online of PDF Electronic Documents System)

  • 유영수;강영립;김병현;이광수
    • 한국인쇄학회:학술대회논문집
    • /
    • 한국인쇄학회 2001년도 국제학술발표회
    • /
    • pp.63-77
    • /
    • 2001
  • PDF(Portable Document Format) is a file format that Adobe advances postscritp technique and use in managing document information or electric publishing(internet, CD-ROM, DVD). PDF is a devised document type for being able to read and print anywhere, independent of OS, printer type, resolution, and the kind of computer etc. Because this includes a compressing function, it transfers document through a small size of file in internet or intranet. In addition, that is a file format has various advantages-sharing of information and transfering documents in on line or off line environment. In this paper, we developed electronic document system using PDF format. Electronic document system consists of filter, automatic indexing, special searching system and web server. The information used in this paper is database made using Zwon\`s DocuCom. The filter recognizes various kinds of document structure. And according to property of document, it produces ASCII output. In addition to processing various formats of document, the filter can extract keywords in documents of MS WORD, Excel, Powerpoint, PDF, CAD etc. This filter uses the structure of window printer drive and can extract the information for text, page, font type and size from relevant document. The automatic indexing recognizes the formatted tag of document form ASCII text produced by filter and extracts adequate keyword to structure and property of document. PDF electronic document systems proposed in this paper can be used in Internet, PC communication. Users can choose and read electronic documents by two ways. First, users can choose and read relevant books using PDF electronic document homepage. Second, users can use PDF integrated-search system. User can search after inputing keyword and choose reference field and type of data. But, now, PDF products of Adobe can\`t support the Korean character. If this problem is resolved, we thick that PDF applications system looks active. Although there is limited function in case of using Zwon DocuCom used in this study, we think that there isn\`t a great deal of difficulty in electronic document and building digital database.

  • PDF

관성측정장치를 이용한 경추 가동범위 측정에 대한 고찰 (A review on measuring cervical range of motion using an inertial measurement unit)

  • 임주혁;김현호;박영재;박영배
    • 대한한의학회지
    • /
    • 제38권1호
    • /
    • pp.56-71
    • /
    • 2017
  • Objectives: The purpose of this study was to review the article using an IMU(Inertial Measurement Unit) for measuring the cervical range of motion and to evaluate the feasibility of using an IMU for measuring the cervical range of motion. Method: Scopus was used to search for the articles relating to the inclusion criteria. Which is measuring the cervical range of motion using an IMU. A total of 15 articles were selected through discussion. Degree and the reliability of the cervical range of motion and the validity of the data within the articles were extracted. Results: The measurement of the cervical range of motion using an IMU were $92.25^{\circ}$ to $138.2^{\circ}$, $122.4^{\circ}$ to $154.9^{\circ}$, $73.75^{\circ}$ to $93.1^{\circ}$ on the sagittal plane, transverse plane, and coronal plane respectively. 38 of the 43 values showed good reliability. They were larger than 0.75. 5 of the 43 values showed reliability less than 0.75. They were measured by smart phone. 16 of the 21 values showed good validity. The remaining 5 were measured by smart phone. The lower reliability and validity of smart phone were related to the protocol. The IMU can measure the coupling motion and may be used in various situations. Conclusion: The IMU may become a gold standard for measuring the cervical range of motion. The IMU measured not only the cervical range of motion but also the coupling motion. Furthermore, IMU may be used in various situations. Therefore, IMU must be considered a valuable measurement device.

PSA 기법에 근거한 생산라인상의 디지털 회로 보오드 검사전략에 대한 연구 (A Study on the Test Strategy of Digital Circuit Board in the Production Line Based on Parallel Signature Analysis Technique)

  • 고윤석
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권11호
    • /
    • pp.768-775
    • /
    • 2004
  • The SSA technique in the digital circuit test is required to be repeated the input pattern stream to n bits output nodes n times in case of using a multiplexor. Because the method adopting a parallel/serial bit convertor to remove this inefficiency has disadvantage of requiring the test time n times for a pattern, the test strategy is required, which can enhance the test productivity by reducing the test time based on simplified fault detection mechanism. Accordingly, this paper proposes a test strategy which enhances the test productivity and efficiency by appling PAS (Parallel Signature Analysis) technique to those after analyzing the structure and characteristics of the digital devices including TTL and CMOS family ICs as well as ROM and RAM. The PSA technique identifies the faults by comparing the reminder from good device with reminder from the tested device. At this time, the reminder is obtained by enforcing the data stream obtained from output pins of the tested device on the LFSR(Linear Feedback Shift Resister) representing the characteristic equation. Also, the method to obtain the optimal signature analyzer is explained by furnishing the short bit input streams to the long bit input streams to the LFSR having 8, 12, 16, 20bit input/output pins and by analyzing the occurring probability of error which is impossible to detect. Finally, the effectiveness of the proposed test strategy is verified by simulating the stuck at 1 errors or stuck at 0 errors for several devices on typical 8051 digital board.

경골 원위부 골절에서 최소 침습적 잠김 압박 금속판 고정술과 함께 최소 절개를 통한 골절편간 지연 나사 고정술을 시행한 경우의 치료 결과 (Clinical Outcomes of Combinations of Locking Compression Plate Fixation through Minimally Invasive Precutaneous Plate Osteosynthesis and Interfragmentary Screw Fixation in Distal Tibia Fracture)

  • 정형진;추지웅
    • 대한족부족관절학회지
    • /
    • 제17권2호
    • /
    • pp.136-142
    • /
    • 2013
  • Purpose: To analyze the outcome of distal tibia fracture treated with the Distal Tibia LCP with combination of interfragmentary screw. Materials and Methods: Between January 2008 and March 2012, data of 34 patients with fracture of distal tibia treated with the Distal Tibia LCP with or without combination of interfragmentary screws were reviewed. There were 17 males and 17 females with an average age of 51.8 years (range, 18~77 years). Radiographic union time and time from surgery until ability to full weight bearing were measured and compared. Callus index was measured as quotient of callus thickness and diameter of corticalis both in AP and sagittal direction. Results: 12 fractures were treated with interfragmentary screws and 22 fractures were treated with bridging plate alone. In interfragmentary fixation group, time to full weight bearing was 14 weeks versus 15.75 weeks without screw. Callus index at bearing was not significantly lesser in patients with screw compated with those without, but callus index difference at posterative 4weeks was sigficant. Radiologic union time was 11.3 weeks in interfragmentary fixation group and 12.58 weeks without screw. Conclusion: The osteosynthesis with the Distal tibia LCP with combination of interfragmentary screw seems to be more stable in postoperative 4weeks than Distal tibia LCP alone, expecting to earlier ROM exercise and rehabilitation.