A LONG-TERM FIELD TEST OF A LARGE VOLUME IONIZATION CHAMBER BASED AREA RADIATION MONITORING SYSTEM DEVELOPED AT KAERI

  • Kim, Han-Soo;Ha, Jang-Ho;Park, Se-Hwan;Kim, Jung-Bok;Kim, Young-Kyun;Jin, Hyung-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.2
    • /
    • pp.77-81
    • /
    • 2009
  • An Area Radiation Monitoring System (ARMS) ionization chamber, which had an 11.8 L active volume, was fabricated and performance-tested at KAERI. Low leakage currents, linearities at low and high dose rates were achieved from performance tests. The correlation coefficients between the ionization currents and the dose rates are 1 at high dose rate and 0.99 at low dose rate. In this study, an integration-type ARMS ionization chamber was tested over a year for an evaluation of its long-term stability at a radioisotope (RI) repository of the Young-gwang nuclear power plant. The standard deviation of dose rate of 1 day data and over a 100-days mean value were 6.2 $\mu$R/h and 2.9 $\mu$R/h, respectively. The fabricated ARMS ionization chamber showed stable performance from the results of the long-term tests. Design and performance characteristics of the fabricated ionization chamber for the ARMS from performance-tests are also addressed.

Electronic Circuit System of a Portable Rl Gauge for Compaction Control (성토다짐용 휴대용 Rl 계기의 전자회로 시스템)

  • 김기준
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.4 no.2
    • /
    • pp.32-38
    • /
    • 1999
  • In this study, an objection is to develop a electronic circuit of a gauage using radioisotope for compaction control to be needed at public works The developed gauage makes use of radioisotope with the activity exempted from domestic atomic law and consists of measuring circuits for gamma-rays and thermal neutrons, a high voltage supply unit and a microprocessor. To obtain meaningful numbers of pulse counts, parallel five and tow circuits are provided for gamma-rays and thermal neutrons, respectively. Also, to minimize effects of natural environmental radiation and electrical noise, circuits are electrostatically shielded and pulses made by ripples are eliminated by taking frequency of high voltage supplied to the circuit and pulse height of ripples into consideration One-chip microprocessor is applied to process various counts, results are stored, Enough and meaningful numbers of pulses are counted with the prototype gauage for compaction control.

  • PDF

The Assessment of The Collective Dose Resulting from Airborne Releases of Radionuclides (방사성핵종(放射性核種)의 대기방출(大氣放出)로 인한 집단선량(集團線量) 평가(評價))

  • Lee, Tea-Young;Yook, Chong-Chul;Lee, Byung-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.8 no.2
    • /
    • pp.41-46
    • /
    • 1983
  • Annual collective dose within 50 miles radius of Ko-ri I reactor site due to normal airborne effluent discharges in 1979 has been estimated by AIRDOS-EPA computer code. Gaussian plume equation is used for estimation of both horizontal and vertical dispersion of radionuclide release into the atmosphere. Also, radionuclide concentrations in meat, milk, and fresh produce consumed by near-by population are estimated by coupling the output of the atmospheric transport models with the USNRC terrestrial food chain models. Annual collective doses are found to be $3.348{\times}10^{-1}$ whole body manrem and 84.95 thyroid manrem. Whole body manrem calculated by AIRDOS-EPA computer code do not differ greatly from that calculated by GASPAR computer code, but value for thyroid manrem have been estimated lower than that calculated by GASPAR computer code.

  • PDF

Primary Pulmonary Malignant Melanoma Presenting as Bilateral Multiple Subsolid Nodules: A Case Report (다수의 양측성 반고형결절들로 발현한 원발성 폐 악성 흑색종: 증례 보고)

  • Eun Gyu Soh;Ji Young Rho;Sooyeon Jeong;Se Ri Kang;Keum Ha Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.2
    • /
    • pp.387-393
    • /
    • 2022
  • Primary pulmonary malignant melanoma is an extremely rare type of melanoma. The radiologic features of primary pulmonary malignant melanoma are nonspecific; however, it almost always presents as a well-demarcated round or lobulated solitary solid nodule or mass. Herein, we report the case of a 78-year-old male with primary pulmonary malignant melanoma that was mistaken for primary pulmonary adenocarcinoma with lepidic growth and was seen as bilateral multiple subsolid nodules on CT.

The Expression of Clara Cell Secretory Protein in BAL Fluid of Patients with Idiopathic Interstitial Pneumonia (특발성 간질성 폐렴 환자의 기관지 폐포 세척액 내의 Clara Cell Secretory Protein 발현에 대한 연구)

  • Um, Sang-Won;Han, Seon-Jin;Choi, Chang-Min;Lee, Chang-Hoon;Yoo, Chul-Gyu;Lee, Choon-Taek;Han, Sung-Koo;Shim, Young-Soo;Kim, Young-Whan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.2
    • /
    • pp.127-135
    • /
    • 2002
  • Background : Idiopathic interstitial pneumonia is characterized by chronic inflammation and pulmonary fibrosis. The clara cell 10 kD protein (CC10, also designated CC16) is synthesized by the bronchial epithelium and has been suggested to have a potent anti-inflammatory effect. Therefore, CC-10 might be a candidate for controlling the inflammatory events in patients with idiopathic interstitial pneumonia. The aim of this study was to determine if the degrees of pulmonary fibrosis in idiopathic interstitial pneumonia is associated with CC-10 in the BAL fluid. Materials and Methods : The BAL fluid was collected from 29 patients and 10 controls. Densitometric analysis of the western blot assay for the CC-10 was subsequently performed. The RI (relative intensity) of each band was compared according to the diagnosis, the radiological degrees of pulmonary fibrosis and the relative proportion of inflammatory cells in the BAL fluid. Results : There were no differences in the CC-10 expression levels in the BAL fluid between the patients (RI $77.5{\pm}75.8%$) and the controls ($70.7{\pm}39.8%$) (p>0.05). In addition, the degrees of pulmonary fibrosis and airway inflammation in patients with usual interstitial pneumonia were not associated with CC-10 expression in the BAL fluid (p>0.05). Conclusion : This study suggests that CC-10 expression is not associated with the degrees of pulmonary fibrosis in patients with usual interstitial pneumonia.

A Study on the Determination of the Appropriate Imaging Conditions in the Use of Scintillation Camera (Scintillation Camera 사용시(使用時) 적정(適正)한 촬상조건(撮像條件)의 설정(設定)에 관(關)한 연구(硏究))

  • Huh, Joon;Kyong, Kwang-Hyon
    • Journal of radiological science and technology
    • /
    • v.6 no.1
    • /
    • pp.103-113
    • /
    • 1983
  • Scintillation cameras을 사용(使用)할때 양질(良質)의 화상(畵像)을 얻기 위하여 camera의 성능(性能), 방사성의약품(放射性醫藥品)의 특성(特性), 그리고 적정(適正)한 촬상조건(撮像條件)을 고려할 필요(必要)가 있다. 특(特)히 RI 상(像)에 대한 촬상조건(撮像條件)은 film의 성질(性質), 상(像)의 크기, 상(像)의 농도(濃度), window, 그리고 콜리메타 전면(前面)으로부터 거리(距離) 등(等)에 따라서 좌우(左右)된다. 이러한 요인(要因)들은 각각 화상(畵像)을 만드는 과정에 영향(影響)을 미치고 있다. 그러므로 상(像)의 표준화(標準化)와 촬상방법(撮像方法)의 기준(基準)을 확립(確立)하기가 매우 어렵다. 고로 이러한 문제(問題)들을 해결(解決)하는 것은 Scintillation camera을 사용(使用)하는 핵의학적(核醫學的) 검사(檢査)에 있어서 매우 중요(重要)하다. 저자(著者)는 이러한 점(點)을 고려하여 일정(一定)한 상(像)의 농도(濃度)을 얻을 수 있는 촬상조건(撮像條件)에 대(對)하여 실험(實驗)을 하였다. 실험(實驗)에 있어서 평행다공형(平行多孔型) 콜리메타를 camera의 head에 부착(附着)시키고 $^{99m}Tc$(3mCi)가 넣어져 있는 liver phantom을 콜리메타의 표면(表面)에 밀착(密着)시켜 다음과 같은 방법(方法)에 의하여 촬상(撮像)하였다. 즉, 일정(一定)한 상(像)의 농도(濃度)을 얻을 수 있는 촬상조건(撮像條件)을 찾아낼 목적(目的)으로 preset time, image size, 콜리메타전면(前面)- phantom간(間) 거리(距離), 그리고 window를 각각(各各) 변화(變化)시키면서 phantom을 촬상(撮像)하였으며, 특(特)히 거리(距離)와 window에 있어서는 cold defects의 검출능(檢出能)도 비교검토(比較檢討)하였다. 실험결과(實驗結果)는 다음과 같다. 1. C type film에 있어서 1.5의 농도(濃度)을 얻기위해서는 7.5의 intensity 에서 preset time은 60초(秒), image size는 1.0, 콜리메타-phantom간거리(間距離)는 0cm 그리고 window는 20%가 요구(要求)되고 있었다. 2. 편면유제(片面乳劑) film의 preset time은 양면유제(兩面乳劑) film보다 짧은 것으로 나타났다. 3. 상(像)의 분해능(分解能)은 image size가 작을수록, 콜리메타-phantom간(間) 거리(距離)가 짧을수록, 그리고 window 폭(幅)이 좁을수록 더욱 더 향상(向上)되고 있었다. 4. Cold defects의 검출능(檢出能)은 image size가 작을수록, 콜리메타-pantom간(間) 거리(距離)가 짧을수록, 그리고 window폭(幅)이 좁을수록 향상(向上)되고 있었다.

  • PDF

Development of Effective ${\gamma}$-ray and ${\beta}$-ray Detection Methods For Low-Level Radioactive Wastes (극저준위 방사성 폐기물을 위한 효율적인 ${\gamma}$-선 및 ${\beta}$-선 측정 방법 개발)

  • Kwak, Sung-Woo;Yeom, Yu-Sun;Kim, Ho-Kyung;Cho, Gyu-Seong;Park, Joo-Wan;Kim, Chang-Lak;Song, Myung-Jae
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.4
    • /
    • pp.393-398
    • /
    • 2001
  • The non-combustible RI wastes disposed of in hospital every year emit ${\gamma}$-ray or ${\beta}$-ray but their activities are very low to the extent of background. Development of more simple methods is needed because the conventional detection methods are so ineffective and complex. In this study, to solve this problem, detection method using efficiency curve for ${\gamma}$-ray emitting radioactive wastes measurement is proposed and experimental detection efficiency equation is also determined through HPGe's standard specimen measurement. For ${\beta}$-emitting radioisotopes detection, new measurement method using detection efficiency estimated by Monte Carlo simulation and SBD measurements is also proposed. According to the results of this paper, the unknown activity of low-level radioactive wastes without LSC requiring the preparation of standard sample and measurement for standard source detection efficiency could be determined efficiently and simply about ${\pm}17%$ in errors by using the theoretical detection efficiency and the SBD measurement result.

  • PDF

Expression of Jun and p53 Genes from the Brain of Rats Irradiated with $^{60}Co{\gamma}$-ray (감마선 조사에 의한 뇌조직의 Jun 및 p53유전자 발현)

  • Kim Yong Seok;Woo Chong Kyu;Lee Yong Sung;Koh Jai Kyung;Chun Ha Chung;Lee Myung Za
    • Radiation Oncology Journal
    • /
    • v.14 no.4
    • /
    • pp.265-279
    • /
    • 1996
  • Damage produced by radiation elicits a complex response in mammalian cells, including growth rate changes and the induction of a variety of genes associated with growth control and apoptosis. At doses of 10,000 cGy or greater, the exposed individual was killed in a matter of minutes to a couple of days, with symptoms consistent with pathology of the central nervous system(CNS) including degenerative changes. The nature of the damage in irradiated cells underlies the unique hazards of ionizing radiation. Radiation injury to CNS is a rare event in clinical medicine, but it is catastrophic for the patient in whom it occurs. The incidence of cerebral necrosis has been reported as high as 16% for doses greater than 6,000 cGy. In this study, the effect of radiation on brain tissue was studied in vivo. Jun and p53 genes in the rat brain were induced by whole body irradiation of rat with 600Co in doses between 1 Gy and 100 Gy and analyzed for expression of jun and p53 genes at the postirradiation time up to 6 hours. Northern analyses were done using 1.8 Kb & 0.8 Kb-pGEM-2-JUN/Eco RI/Pst I fragments, 2.0 Kb-php53B/Bam HI fragment and ,1.1 Kb-pBluescript SK--ACTIN/Eco RI fragment as the digoxigenin or [${\alpha}^{32}P$] dCTPlabeled probes for Jun, p53 and ${\beta}$-actin genes, respectively. Jun gene seemed to be expressed near the threshold levels in 1 hour after irradiation of $^{60}$Co in dose less than 1 Gy and was expressed in maximum at 1 hour after irradiation of $^{60}$Co in dose of 30 Gy. Jun was expressed increasingly with time until 5 or 6 hours after irradiation of $^{60}$Co in doses of 1 Gy and 10 Gy. After irradiation of $^{60}$Co in dose between 20 Gr and 100 Gy, the expression of Jun was however increased to peak in 2 hours and decreased thereafter. p53 gene in this study also seemed to be expressed near the threshold levels in 1 hour after irradiation of $^{60}$Co in dose less than 1 Gy and was expressed in maximum at 6 hours after irradiation of $^{60}$Co in dose of 1 Gy, p53 was expressed increasingly with time until 5 or 6 hours after irradiation of $^{60}$Co in dose between 1 Gy and 40 Gy. After irradiation of $^{60}$Co in doses of 50 Gy and 100 Gy, the expression of p53 was however increased to peak in 2 hours and decreased thereafter. The expression of Jun and p53 genes was not correlative in the brain tissue from rats. It seemed to be very important for the establishment of the optimum conditions for the animal studies relevant to the responses of genes inducible on DNA damage to ionizing radiation in mammalian cells. But there are many limitations to the animal studies such as the ununiform patterns of gene expression from the tissue because of its complex compositions. It is necessary to overcome the limitations for development of in situ Northern analysis.

  • PDF

A Study for Analysis of Image Quality Based on the CZT and NaI Detector according to Physical Change in Monte Carlo Simulation (CZT와 NaI 검출기 물질 기반 물리적 변화에 따른 영상의 질 분석에 관한 연구: 몬테카를로 시뮬레이션)

  • Ko, Hye-Rim;Yoo, Yu-Ri;Park, Chan-Rok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.741-748
    • /
    • 2021
  • In this study, we evaluated image quality by changing collimator length and detector thickness using the Geant4 Application for Tomographic Emission (GATE) simulation tool. The gamma camera based on the Cadimium Zinc Telluride (CZT) and NaI detectors is modeled. In addition the images were acquired by setting 1, 2, 3, 4, 5, and 6 cm collimator length and 1, 3, 5, and 7 mm detector thickness using point source and phantom, which is designed by each diameter (4.45, 3.80, 3.15, 2.55 mm) with 447, 382, 317, and 256 Bq. The sensitivity (cps/MBq) for point source, and signal to noise ratio (SNR) and profile for phantom at the 4.45 mm by drwan the region of interests were used for quantitative analysis. Based on the results, the sensitivity according to collimator length is 2.3 ~ 48.6 cps/MBq for CZT detector, and 1.8 ~ 43.9 cps/MBq for NaI detector. The SNR using phantom is 3.6~9.8 for CZT detector, and 2.9~9.5 for NaI detector. As the collimator length is increased, the image resolution is also improved according to profile results based on the CZT and NaI detector. In addition, the senistivity for detector thickness is 0.04 ~ 0.12 cps/MBq for CZT detector, and 0.03 ~ 0.11 cps/MBq. The SNR using phnatom is 7.3~9.8 count for CZT detector, and 5.9~9.5 for NaI detector. As the detector thickness is increased, the image resolution is decreased according to profile results based on the CZT and NaI detector due to scatter ray. In conclusion, we need to set the geometric material such as detector and collimator to acuquire suitable image quality in nuclear medicine.

Physical Properties Effect of Dry-Heat and Microwave-Cured Acrylic Resins depending on the Irradiation-Induced Changes (유도광선변화에 따른 건식중합과 마이크로파중합 아크릴레진의 물리적 성질영향)

  • Kim, Gyu-Ri
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4388-4397
    • /
    • 2015
  • The purpose of this study was to research the property change of acrylic resins depending on the induced-beam change and research the improved physical property of dry-heat and microwave-cured dental place acrylic resin in order to develop the acrylic resins with the optimum characteristic. As a result of observing flexural rigidity, hardness and color difference, the dry-heat-cured specimens of Vertex RS and Paladent 20 showed ideal property at 5, 15, and 25 kGy irradiation. The microwave-cured specimens of Vertex RS and Paladent 20 showed ideal property at 5 kGy irradiation. The correlation analysis showed a positive correlation among ARD, flexural rigidity (0 418), E coefficient (0.675) and Barcol hardness (0 588). The radiation cure technology is helpful for relieving the contamination caused by the manufacture of polymer composite. It can significantly contribute to the fusion of ultra violet cure technology and nano technology and the improvement of mechanical property without giving effect to the workability of polymer.