• 제목/요약/키워드: RF monitoring system

검색결과 181건 처리시간 0.025초

Pet Location Tracking and Remote Monitoring System using a Wireless Sensor Network (무선센서네트워크를 이용한 애완동물 위치추적 및 원격모니터링 시스템)

  • Hwang, Sung-Ho;Park, Jae-Choon;Kwon, Ki-Hyeon;Choi, Shin-Hyeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제12권1호
    • /
    • pp.351-356
    • /
    • 2011
  • In this paper, we design a pet location tracking and remote monitoring system that uses ultrasonic, temperature, humidity and illumination sensors to study behavioral patterns and habits. Using ultrasonic waves to calculate distances, a WSN(Wireless Sensor Network) was constructed to transmit data at pet's location, such as temperature, humidity and illumination, to a sink mote. Data received by the system are stored in the database in real time to trace pet's location. Interference among transmitting motes was eliminated by sequentially transmitting RF beacons using sink mote's beacon as the reference signal. Experiments were performed with the laboratory prototype of a pet animal monitoring system implemented for this study. The system analyzes locations of a pet and displays movement patterns, areas of movement, temperature, humidity and illumination using a GUI (graphical user interface).

Temperature-Range-Dependent Optimization of Noninvasive MR Thermometry Methods (온도범위에 따른 비침습적 자기공명 온도측정방법의 최적화)

  • Kim, Jong-Min;Kumar, Suchit;Jo, Young-Seung;Park, Joshua Haekyun;Kim, Jeong-Hee;Lee, Chulhyun;Oh, Chang-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • 제36권6호
    • /
    • pp.241-250
    • /
    • 2015
  • Noninvasive temperature monitoring is feasible with Magnetic Resonance Imaging (MRI) based on temperature sensitive MR parameters such as $T_1$ and $T_2$ relaxation times, Proton Resonance Frequency shift (PRFs), diffusion, exchange process, magnetization transfer contrast, chemical exchange saturation transfer, etc. While the temperature monitoring is very useful to guide the thermal treatment such as RF hyperthermia or thermal ablation, the optimization of the MR thermometry method is essential because the range of temperature measurement depends on the choice of the measurement methods. Useful temperature range depends on the purpose of treatment methods, for example, $42^{\circ}C$ to $45^{\circ}C$ for RF hyperthermia and over $50^{\circ}C$ for thermal ablation. In this paper, MR thermometry methods using $T_1$ and $T_2$ relaxation times and PRFs-based MR thermometry are tried on a 3.0 T MRI system and their results are reported and compared. In addition, the scanning protocol and temperature calculation algorithms from $T_1$ and $T_2$ relaxation times and PRFs are optimized for the different temperature ranges for the purpose of RF hyperthermia and/or thermal ablation.

Design of Autonomous Stair Robot System (자율주행 형 계단 승하강용 로봇 시스템 설계)

  • 홍영호;김동환;임충혁
    • Journal of Institute of Control, Robotics and Systems
    • /
    • 제9권1호
    • /
    • pp.73-81
    • /
    • 2003
  • An autonomous stair robot recognizing the stair, and climbing up and down the stair by utilizing a robot vision, photo sensors, and appropriate climbing algorithm is introduced. Four arms associated with four wheels make the robot climb up and down more safely and faster than a simple track typed robot. The robot can adjust wheel base according to the stair width, hence it can adopt to a variable width stair with different algorithms in climbing up and down. The command and image data acquired from the robot are transferred to the main computer through RF wireless modules, and the data are delivered to a remote computer via a network communication through a proper data compression, thus, the real time image monitoring is implemented effectively.

Analysis of Sildenafil and its Analogues by LC/MS/MS (LC/MS/MS를 이용한 sildenafil 및 그 유사체 분석)

  • Myung, Seung-Woon;Park, So-Hee;Cho, Hyun-Woo
    • Analytical Science and Technology
    • /
    • 제16권6호
    • /
    • pp.488-498
    • /
    • 2003
  • By LC/MS/MS, the analytical method of sildenafil and its analogues (homosildenafil, vardenafil and tadalafil) used as used medical treatment of impotence was established. electrosprary ionization (ESI) and atmospheric pressure chemical ionization (APCI) as a ionization method were applied. Several parameter were varied and the sensitivity and reproducibility were compared. In LC/ESI-MS method, capillary voltage, cone voltage, extractor, entrance and RF lens to create appropriate productr ions for multiple reaction monitoring (MRM) were variable parameter, but the formation of the other product ions except the precursor ion could not detect. And the value of entrance, collision energy, exit, corona voltage, cone voltage, extractor, RF lens, cone gas, and desolvation gas in APCI mode were varied, only the creation pattern of fragment ions by the change of RF lens value were detected, and the limit of detection was decreased due to the increase of S/N. Ten millimole ammonium formate (pH 4.8):acetonitrile=70:30 by isocratic elution in HPLC system was shown the maximum sensitivity in MS, the detection limit of sildenafil, homosildenafil, vardenafil and tadalafil obtained by ESI-MRM were 0.10, 0.025, 0.025, and $0.25{\mu}g/mL$ at S/N>5, respectively.

위성발사를 위한 원격측정 지상국시스템 설계에 관한 연구

  • Lee, Sung-Hee;Oh, Chang-Yul;Lee, Hyo-Keun
    • Aerospace Engineering and Technology
    • /
    • 제2권2호
    • /
    • pp.167-178
    • /
    • 2003
  • The design on the Telemetry Ground System for launch of KSLV(Korea Space Launch Vehicle) in the korean Space center has been conducted in this study. For the optimized system design, first of all, the system deployment plan reflecting the topographic and geographic environments of the space center and launch vehicle characteristics has been developed. The RF link budget analysis for the maximum tracking range, requirement for receiving subsystem including antenna subsystem, requirement for data processing subsystem are also analyzed based on the On-Board Telemetry characteristics and launch vehicle parameters. Based on those analysis, telemetry ground system containing tracking/receiving subsystem, recording subsystem and data processing subsystem, timing subsystem, calibration subsystem and monitoring and control subsystem are designed. Futhermore, the analysis for the maximum permissible data latency and communication protocol between each telemetry station and control center are conducted and the entire system is designed so that the major telemetry parameters selected to the best quality are provided in real time to the control center(RCC, RSC) for the launch mission operation.

  • PDF

The study on Remote Monitoring System for Fault Indicator used in underground Distribution Line (지중배전선로 고장표시기 원격감시시스템 개발에 관한 연구)

  • Jung, Geum-Young;Oh, Young-Hyun;Song, Wan-Seok
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.667-669
    • /
    • 2005
  • 지중배전선로에 설치되어 있는 23kV 수동개폐기의 고장표시 상태를 단말장치와 소출력 RF 통신을 이용하여 배전자동화 주장치에서 FII(Fault Indicator)로 고장 판단할 수 있는 시스템 구성에 대해 논하고자 한다.

  • PDF

Intrusion Detection System for Mobile Ad hoc Network using Characteristics of MAC & LLC Layer (MAC 및 LLC Layer의 특성을 이용한 Mobile Ad hoc 네트워크에서의 침입탐지에 관한 연구)

  • 이재상;김동성;박종서
    • Proceedings of the Korea Institutes of Information Security and Cryptology Conference
    • /
    • 한국정보보호학회 2003년도 하계학술대회논문집
    • /
    • pp.279-282
    • /
    • 2003
  • Mobile Ad hoc망의 경우 단말기에서 무선접속 인터페이스만 있으면 침입자로 하여금 쉽게 접속이 가능하게 하며, SSID와 WEP Key를 쉽게 취득하여 네트워크의 일원으로 참여할 수 있는 보안상의 취약성이 존재한다. 보안 취약성을 극복하기 위해서는 한정된 에너지 자원과 프로세서를 가진 무선 단말기로 침입탐지를 수행하기에는 문제점들이 존재한다. 따라서 본 논문에서는 프로세스 부하를 줄이는 IEEE802.11 Frame헤더의 Sequence Number 분석방법과 효과적으로 침입을 탐지할 수 있는 RF Monitoring을 이용하여 Mobile Ad hoc 환경에 적합한 칩입탐지 시스템을 제안한다.

  • PDF

Real-time Reefer Container Monitoring System based on IoT (IoT 기반 실시간 냉장컨테이너 상태 모니터링 시스템)

  • Moon, Young-Sik;Jung, Jun-Woo;Choi, Sung-Pill;Kim, Tae-Hoon;Lee, Byung-Ha;Kim, Jae-Joong;Choi, Hyung-Lim
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제19권3호
    • /
    • pp.629-635
    • /
    • 2015
  • In this paper, we propose the reefer container monitoring system that not only monitors internal temperature, humidity of reefer container but also tracks the real-time location using GPS. It consists of a tag of information of situation using 433MHz RF transmitter(communication), GPS to track the real-time location and a device using WCDMA/GSM communication to transmit information to the server. We tested by applying the proposed system in reefer containers with yellow melons, melons transported from Korea to Singapore to track the location and check the temperature and the humidity. The result of this test is that there is a temperature difference around 1.7 degree depending on the position of inside of container and maintains the humidity stably about 97%. If we apply this proposed system to agricultural marketing, it is possible to get the time that fruits start to decay and minimize the loss of fruits by decaying during shipping.

Location Tracking System for Container Trailer Using Ubiquitous Sensor Networks (USN를 이용한 컨테이너 트레일러 위치추적 시스템)

  • Park, Jong-Hyun;Choo, Young-Yeol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제11권3호
    • /
    • pp.627-633
    • /
    • 2007
  • This paper describes position tracking system of a container trailer approaching to a gantry crane for loading or unloading a container into or from a ship, respectively. Proposed position tracking system informs the trailer driver of right position to stop the car under a gantry crane. To measure the location of a trailer, we used Cricket Mote modules which adopted RF and ultrasound technology. We present an elaborate method to improve position errors occurring at sensing and calculate three dimensional position by triangulation along with how to reduce location tracking interval for real-time monitoring. The location information was transmitted to a Personal Digital Assistant (PDA) periodically through Bluetooth communication for guidance of the trailer driver. In indoor and outdoor tests, position errors were less than 3 cm and location tracking interval was 0.5 second on average.

RGB-LED-based Optical Camera Communication using Multilevel Variable Pulse Position Modulation for Healthcare Applications

  • Rachim, Vega Pradana;An, Jinyoung;Pham, Quan Ngoc;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • 제27권1호
    • /
    • pp.6-12
    • /
    • 2018
  • In this paper, a 32-variable pulse position modulation (32-VPPM) scheme is proposed to support a red-green-blue light-emitting-diode (RGB-LED)-based optical camera communication (OCC) system. Our proposed modulation scheme is designed to enhance the OCC data transmission rate, which is targeted for the wearable biomedical data monitoring system. The OCC technology has been utilized as an alternative solution to the radio frequency (RF) wireless system for long-term self-healthcare monitoring. Different biomedical signals, such as electrocardiograms, photoplethysmograms, and respiration signals are being monitored and transmitted wirelessly from the wearable biomedical device to the smartphone receiver. A common 30 frames per second (fps) smartphone camera with a CMOS image sensor is used to record a transmitted optical signal. Moreover, the overall proposed system architecture, modulation scheme, and data demodulation are discussed in this paper. The experimental result shows that the proposed system is able to achieve > 9 kbps using only a common smartphone camera receiver.