• Title/Summary/Keyword: RF Detector

Search Result 122, Processing Time 0.029 seconds

Vital Sign Sensor Based on Second Harmonic Frequency Drift of Oscillator (발진기의 2채배 고조파 주파수 천이를 이용한 생체신호 측정센서)

  • Ku, Ki-Young;Hong, Yunseog;Lee, Hee-Jo;Yun, Gi-Ho;Yook, Jong-Gwan;Kim, Kang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.3
    • /
    • pp.299-306
    • /
    • 2016
  • In this paper, a vital sign sensor based on impedance variation of resonator is proposed to detect the respiration and heartbeat signals within near-field range as a function of the separation distance between resonator and subject. The sensor consists of an oscillator with a built-in planar type patch resonator, a diplexer for only pass the second harmonic frequency, amplifier, SAW filter, and RF detector. The cardiac activity of a subject such as respiration and heartbeat causes the variation of the oscillation frequency corresponding impedance variation of the resonator within near-field range. The combination of the second harmonic oscillation frequency deviation and the superior skirt frequency of the SAW filter enables the proposed sensor to extend twice detection range. The experimental results reveal that the proposed sensor placed 40 mm away from a subject can reliably detect respiration and heartbeat signals.

Design and implementation of power-controlled front-end module for direct conversion receiver (전력제어 직접변환수신 6단자 소자 설계 및 제작)

  • Kim, Young-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.11
    • /
    • pp.2391-2396
    • /
    • 2010
  • The power-controlled six-port element that can control the local oscillator signal power and receiving RF signal power was designed and implemented in this paper. The direct conversion six-port element configuration was proposed, which provides the constant six-port output power by controlling the six-port input power with various signal strength. The direct conversion six-port element protects the power detector element of six-port receiver from the saturation status and compensates the transmission performance degradation. For implementation of power-controlled six-port element, the power-controlled six-port element including the power controller was analyzed. The implemented power-controlled six-port element shows the power control capability of 36 dB and gain imbalance of about 1.6 dB, phase imbalance of about $4^{\circ}$ in the frequency range of 1.69 GHz. The measured results show the good performance as direct conversion front-end element.

Determination of Ginseng Saponins by Reversed-Phase High Performance Liquid Chromatography (역상 고속 액체크로마토그래피를 이용한 인삼 사포닌의 분석)

  • Jeong, Seung-Il;Kim, Choen-Suk;Lee, No-Woon;Choi, Kang-Ju;Lee, Yong-Gu;Kim, Il-Kwang
    • Analytical Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.436-439
    • /
    • 1998
  • Ginseng saponins were analysed using reversed-phase high performance liquid chromatography with several columns. The optimum conditions were as following : reverse phase column; Novapak $C_{18}$ ODS column ($3.9mm{\times}150mm$, $5{\mu}m$), acetonitrile/water binary mobile phase gradient controller system, solvent flow rate; 1.5 mL/min, and UV (203 nm) detector. The complete separation of ginsenoside $Rb_1$, $Rb_2$, Rc, Rd, Re, Rf and $Rg_1$ was achieved within 50 min. The regression coefficients of the calibration curves for seven ginsenosides were 0.98~0.99.

  • PDF

Study on the Development of Linearity of Broad-Band SDLVA Using Clamping Op-Amp (Clamping Op-Amp를 이용한 광대역 로그 비디오 증폭기의 선형성 개선에 관한 연구)

  • Park, Jong-Sul;Kim, Jong-Geon;Kim, Jum-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.6
    • /
    • pp.641-647
    • /
    • 2011
  • This paper describes a design and fabrication of SDLVA. The SDLVA operates 0.5~2.0 GHz with -70~0 dBm dynamic range. The SDLVA is consisted of 5-stage RF block, 2-stage detector block and summation circuit using clamping op-amp to improve video linearity. The result of measure, SDLVA of RF path has over 73 dB small-signal gain and 10.1~12.2 dBm saturation power. The video path has 25 mV/ dB${\pm}$1.0 mV and under ${\pm}$1.5 dB video linearity.

Influence of Mg composition on growth and characteristic of MgZnO/ZnO heterostructure (MgZnO/ZnO 이종접합구조의 특성과 성장에 Mg 합성이 미치는 영향)

  • Kim, Young-Yi;Kong, Bo-Hyun;Kim, Dong-Chan;An, Cheol-Hyeon;Han, Won-Seok;Choe, Mi-Gyeong;Jo, Hyeong-Gyun;Moon, Jin-Young;Lee, Ho-Seung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.73-73
    • /
    • 2008
  • 일반적으로 청색 및 자외선 발광다이오드, 레이저 다이오드, UV 감지기 (detector)소자 등의 기술적인 중요성은 ZnO를 기반으로 하는 산화물 반도체와 함께 와이드 밴드갭 반도체 연구가 활발히 진행되고 있다. ZnO의 경우 밴드갭 엔지니어링을 위해 일반적으로 Cd과 Mg을 사용하고 있으며 특히, ZnO에 Mg을 첨가하여 MgZnO 화합물을 첨가할 경우 밴드갭을 3.3eV~7.8eV까지 증가 시킬 수 있고, MgZnO/ZnO 초격자 구조를 이용할 경우 자유 엑시톤 결합에너지를 100meV 이상까지 증가시킬 수 있는 장점을 가지고 있다. 그러나 MgO는 결정구조가 rocksalt 구조를 가지는 입방정 구조이기 때문에 Hexagonal 구조를 가진 ZnO에 첨가될 경우 고용도에 큰 제한을 가지게 된다. 이와 같은 문제점으로 인하여 밴드갭 엔지니어링 기술은 여전히 해결되지 않은 문제점으로 남아 있다. 본 실험에서는 RF 마그네트론 스퍼터링 방법으로 사파이어 기판위에 MgZnO/ZnO 박막을 co-sputtering 시켰다. Targer은 ZnO(99.999%) 와 MgO (99.999%) target을 사용하였고, 스퍼터링 가스는 아르곤과 산소가스를 2:1 비율로 혼합시켜 성장하였다. MgZnO 박막을 성장하기 전 ZnO 층을 ~500 두께로 성장 시켰다. RF-power는 ZnO target을 고정 시키고, MgO targe power를 변화시켜 Mg 농도를 조절 하였다. 실험 결과 MgO target power 가 증가 할수록 반치폭이 증가하고, c-plane을 따라 격자 상수가 감소하는 것을 확인 할 수 있고, UV emission peak intensity가 감소며 단파장쪽으로 blue shift 하고, activation energy 가 증가하는 것을 관찰 할 수 있었다.

  • PDF

Design of IM components detector for the Power Amplifier by using the frequency down convertor (주파수 하향변환기를 이용한 전력증폭기의 IM 성분 검출기 설계)

  • Kim, Byung-Chul;Park, Won-Woo;Cho, Kyung-Rae;Lee, Jae-Buom;Jeon, Nam-Kyu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.665-667
    • /
    • 2010
  • In this paper, the method to detect the IM(Inter Modulation) components of power amplifier is proposed by using frequency down-convertor. Output signals of power amplifier which is coupled by 20dB coupler and divided by power divider are applied to RF and LO of the frequency converter. It could be found the magnitude of IM components of power amplifier as a converted DC voltage which is come from the difference between 3th and 5th IM component. The detected DC voltage values are changed from 0.72V to 0.9V when 3rd IM component level changed from -26.4dBm to +2.15dBm and 5th IM component level changed from -34.2dBm to -12.89dBm as the Vgs of 3W power amplifier is changed.

  • PDF

Antioxidant Activity and Inhibitory Effects on Oxidative DNA Damage of Callus from Abeliophyllum distichum Nakai

  • Jang, Tae Won;Park, Jae Ho
    • Korean Journal of Plant Resources
    • /
    • v.31 no.3
    • /
    • pp.228-236
    • /
    • 2018
  • In this study, we evaluated the antioxidant activity and protective effects against oxidative DNA damage of the ethyl acetate fraction from the callus of Abeliophyllum distichum Nakai (ECA). Callus of A. distichum was induced on MS medium containing NAA (1 mg/L) and 2,4-D (1 mg/L), and a sufficient amount was obtained for the extraction by subculture. Acteoside was analyzed and quantified (0.39 mg/g callus) from ECA using the high-performance liquid chromatography-photodiode array detector method. ECA showed very high antioxidative activity as revealed by DPPH and ABTS scavenging assays. The $IC_{50}$ values were 12.4 and $6.8{\mu}g/ml$, respectively. ECA showed protective effects against oxidative DNA damage evaluated by using ${\Psi}X-174$ RF I plasmid DNA. It also inhibited DNA damage by suppressing the oxidative stress-induced protein and mRNA levels of ${\gamma}$-H2AX and p53 in NIH/3T3 cells. In conclusion, ECA protects against oxidative DNA damage through its powerful antioxidant activity.

Taurine Level in Human Milk and Estimated Intake of Taurine by Breast -Fed Infants during the Early Period of Lactation (수유 초기 모유 중 타우린 함량과 영아의 섭취량 추정)

  • 김을상
    • Journal of Nutrition and Health
    • /
    • v.31 no.3
    • /
    • pp.363-368
    • /
    • 1998
  • Taurine is only supplied to the infants from the breast-fed or formula milks because the enzyme activities of taurine biosynthesis are limited in early stages of infants . The objectives of present study were to quantitate the contents of tarurine in human milk and to estimate the intake of taurine by breast-fed infants during early period of lactation. Thirty -three lactating women, volunteered and delivered in R hospital in Serou. were recruited. Milk samples were collected every day at B1-B5 day(from 1 to 5 day dafter start of milk secretion), 15th and 30th day postpartum. Taurine contents were determined by HPLC equipped with RF-detector. The intake of taurine by infants was estimated by multiplization with the infant milk intake reported in our laboratory. The content of taurine was 406$\pm$174nmol/ml at B1-B5 day, and then gradually decreased to 359$\pm$125nmol/ml at 15th day and to 304$\pm$94nmol/ml at 30th day postpartum. The estimated intake of taurine was almost same as 24-25mg/day at B1-B5 day, and 15th , 30th days postpartum . This results was due to the increase of the intake of milk by infants.

  • PDF

Continuous Blood Pressure Monitoring using Pulse Wave Transit Time

  • Jeong, Gu-Young;Yu, Kee-Ho;Kim, Nam-Gyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.834-837
    • /
    • 2005
  • In this paper, we describe the method of non-invasive blood pressure measurement using pulse wave transit time(PWTT). PWTT is a new parameter involved with a vascular that can indicate the change of BP. PWTT is measured by continuous monitoring of ECG and pulse wave. No additional sensors or modules are required. In many cases, the change of PWTT correlates with the change of BP. We measure pulse wave using the photo plethysmograph(PPG) sensor in an earlobe and we measure ECG using the ECG monitoring device our made in the chest. The measurement device for detecting pulse wave consists of infrared LED for transmitted light illumination, pin photodiode as light detector, amplifier and filter. We composed 0.5Hz high pass, 60Hz notch and 10Hz low pass filter. ECG measurement device consists of multiplexer, amplifier, filter, micro-controller and RF module. After amplification and filtering, ECG signal and pulse wave is fed through micro-controller. We performed the initial work towards the development of ambulatory BP monitoring system using PWTT. An earlobe is suitable place to measure PPG signal without the restraint in daily work. From the results, we can know that the dependence of PWTT on BP is almost linear and it is possible to monitoring an individual BP continuously after the individual calibration.

  • PDF

A Study on the Implementation of Exciter in VHF Band (VHF대역 Exciter 구성에 관한 연구)

  • 박순준;황경호;박영철;정창경;차균현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.13 no.3
    • /
    • pp.239-254
    • /
    • 1988
  • In this paper an exciter which performs modulation and amplification is composed of high power(30dBm) VCO(Voltage Controlled Oscillator) using push-pull circuit. Modulation is FSK using PLL(Phase Locked Loop). A single loop PLL synthesizer having sequency range of 42.5-100.5MHz, 25KHz channel spacing and switching time of 1msec converts down the exciter VCO frequency to 1.25MHz. This signal mixed with the FSK modulated signal coming in the phase detector of exciter. The acquisition time of exciter for frequency hoppng is less than 200usec, so the total acquisition time for transmission is less that 1.5msec. There is no need of additional power amplification because power amlifiction by high power VCO is high enough to communicate within near distance. The proposed frequency synthesizer is not complex so it is suitable for low cost slow frequency hopping spread spectrum communication.

  • PDF