• Title/Summary/Keyword: RECLAMATION

Search Result 1,104, Processing Time 0.028 seconds

Effect of Hydrogen Peroxide on UV Treatment of Color in Secondary Effluent for Reclamation (물 재이용을 위한 하수처리장 방류수 색도의 자외선처리에 미치는 과산화수소의 영향)

  • Park, Ki-Young;Maeng, Sung-Kyu;Kim, Ki-Pal;Lee, Seock-Heon;Kweon, Ji-Hyang;Ahn, Kyu-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.377-384
    • /
    • 2004
  • In the present study, a feasibility of an advanced oxidation process using UV/Hydrogen peroxide($H_2O_2$) system equipped with a medium pressure lamp for secondary effluent reclamation was investigated. Initial concentration of $H_2O_2$ and pH were changed to determine the optimum operation condition for the system. The removal efficiency of color was than 80% with 14.3mg/L of initial $H_2O_2$ and 5 minute of contact time in the UV/$H_2O_2$ system. The color removal was analyzed using first-order reaction equation. The dependence of rate constant (k) on initial $H_2O_2$ represented the rational relationship with maximum value. Residual $H_2O_2$ caused increase of effluent COD, since analyzing agent, dichromate, reacted with $H_2O_2$ in the sample. Therefore, excess initial concentration of $H_2O_2$ would significantly affect effluent COD measurement. At pH variation experiment, both residual $H_2O_2$ and color showed peak in the neutral pH range with the same pattern. Effect of $H_2O_2$ dose also enhanced color removal but raised residual $H_2O_2$ problem in the continuous operation UV system. In conclusion, these results indicated that medium pressure UV/$H_2O_2$ system could be used to control color in the secondary effluent for reclamation and reuse.

Enhancement of Discfilter Removal Efficiency for Small-scale Wastewater Reclamation (소규모 하수 재이용을 위한 디스크필터의 처리 효율 증진에 관한 연구)

  • Choi, Nag-Choul;Kim, Bong-Ju;Park, Seong-Yong;Park, Hyeong-U;Lee, Sung-Jae;Park, Cheon-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.4
    • /
    • pp.66-72
    • /
    • 2015
  • The aim of this study was to enhance of the Discfilter process (maximum treatment capacity - 500 ton/day) removal efficiency for small-scale wastewater reclamation under various influent wastewater conditions (with / without coagulation process, coagulant content and temperature). The result of chemical resistance test for fiber filter in the Discfilter that weight loss was obtained with 0.535% under pH 3, 0.092% under pH 9 and 0.028% under 10% NaClO. The removal efficiency test of Discfilter process on the with / without coagulation process showed that with coagulation process condition was occurred CODMn of 42.26 ± 0.61, BOD5 of 88.72 ± 0.44, T-P of 84.67 ± 0.72 and SS of 90.58 ± 0.61. The removal efficiency of Discfilter process on the coagulant content (4.5, 5.0 and 5.0 mL/min) and temperature (< 10℃, 10℃~ 20℃ and > 20℃) conditions were increased as coagulant content and temperature increased. This study demonstrated the potential application of Discfilter process for small-scale wastewater reclamation.

Characterization of Mineralogical and Physicochemical Properties of Soils Contaminated with Metals at Gahak Mine (가학광산 주변 중금속 함유 토양입자의 이화학적·광물학적 특성연구)

  • Lee, Choong Hyun;Lee, Seon Yong;Park, Chan Oh;Kim, Jong Won;Lee, Sang Hwan;Park, Mi Jeong;Jung, Moon Young;Lee, Young Jae
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.4
    • /
    • pp.83-89
    • /
    • 2015
  • Soil samples collected in an area of Gahak Mine were investigated for the characterization of mineralogical and physicochemical properties of contaminants in soils. It is found that soils in the study area are contaminated by lead (Pb), copper (Cu), zinc (Zn), cadmium (Cd), in which their concentrations are 595.3 mg/kg, 184.9 mg/kg, 712.8 mg/kg, and 10.64 mg/kg, respectively. All the concentrations exceed the concern criteria of Korean standard. Upon distribution patterns of metals identified by the sequential extraction procedure, our results show that more than 50% of metals are found as a residual type, and 30% are accounted for the association of Fe/Mn oxides. Interestingly, XRD results show that minium (Pb3O4) and cuprite (Cu2O) are identified in the soil samples, suggesting that the sources of the contaminants for Pb and Cu are these minerals. In SEM images, tens of µm of Pb oxides and Pb silicate-minerals are observed. We, therefore, note that the contamination of metals in the study area results from the direct influx and disturbance of tailings. Our findings indicate that the characterization of physicochemical and mineralogical properties of contaminated soils is a critical factor and plays an important role in optimizing recovery treatments of soils contaminated in mine development areas.

Estimation of Historical Shorelines on a Coastal Reclaimed Land (II) : Shoreline Change Analysis (해안 매립지에서 과거 해안선의 산정 (II): 해안선변화 분석)

  • Kim, Baeck-Oon;Lee, Chang-Kyung
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.21 no.5
    • /
    • pp.380-390
    • /
    • 2009
  • This study was conducted as a part of investigating pre-reclamation shorelines from aerial photographs to estimate coastal land area at reclaimed lands (Anjeong industrial complex, Myeongji residental complex, and Noksan industrial complex), southeastern coast of Korea. To assess how the shorelines were suitable for the calculation of coastal lands, we constructed shoreline change data. Secondary ground control points were used to accomplish triangulation for old aerial photographs. Two kinds of shorelines were mapped; one was the shoreline based on approximately highest high water level (AHHWL) and the other was the high water line based on wet/dry signiture. These shorelines were consistent at artificial coast. Shoreline change data were built with a variety of levels of error due to detailed differences in the photograph scale, quality of image, type of ground control point and type of shoreline. Thus assessment of the pre-reclamation shorelines at the level of qualitative analysis for the trend of shoreline changes was satisfactory. Most of shoreline changes before reclamation in this study were associated with coastal development. Investigation of shoreline attributes in relation to aerial photographs allowed us to understand the shoreline changes.

The Study on the Engineering Characteristics by Self-Hardening of Coal Ash (석탄회의 자경성에 따른 공학적 특성연구)

  • Sang, Jung-Hyuk;Shin, Woong-Gi;Kim, Ji-Won;Chun, Byung-Sik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09b
    • /
    • pp.81-87
    • /
    • 2010
  • As enormous construction projects of land development are carried out around Korea, useful construction materials are needed to perform the construction projects. However, there are no more enough of fill and reclamation materials in our country. That is why the coal ash is expected to be utilized as an alternative material. Since the coal ash has the characteristics of a pozzolan and a selfhardening material, it is adjudged that coal ash has a great possibility to be used as a fill and reclamation material. In this study, grain size analysis, Atterberg limit test, and specific gravity test were performed to examine the physical characteristics of the coal ash about a self-hardening material before utilizing the coal ash in the construction. Compaction test, unconfined compression test were conducted to investigate the engineering characteristics according to mixture ratios of fly ash and bottom ash. As a result of the tests, it was confirmed that the mixing ratio 1:1 of fly ash and bottom ash is the most effective to use as a fill and reclamation material. If the mixture of coal ash is used as a backfill material with light weight around structure, it is expected to play a significant role in reducing earth pressure on the back of the structure. As described above, the coal ash should be considered as an alternative material of fill and reclamation materials since the result of the tests indicates that the coal ash is suitable to a useful material on the construction design.

  • PDF

Developing Object Library Browser for Reclamation Based BIM (BIM 기반의 준설매립전용 Library Browser 개발)

  • Lee, Dongyun;Lee, Junho;Lee, Sangwoong;Choi, Chaseok;Gu, Bonhyo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.3
    • /
    • pp.57-63
    • /
    • 2014
  • This study has been conducted to building a library intended for structures considered in the design of reclamation for design automation and developing browser for integrated management system. The library has been developed using a parametric modeling method capable of changing section shape, also classifying standard crossing and family library, has been developed according to the working environment. Classified library by the characteristics manages objects and working modeling on based BIM has been developed browser using the C# program for objects to use conveniently. By interworking between developed Browser and 3D Autocad based BIM, it is possible to use easily at design drafting, calculating quantities, developing a new library, and managing a library. The browser using effectively exclusive library to reclamation is developed in this study.

Assessment of Advanced Oxidation Processes using Low and Medium-Pressure Lamps with H2O2 for Reclamation of Biologically Treated Wastewater Effluents (하수 2차 처리수 재이용을 위한 저압 및 중압 고도산화시스템의 성능평가)

  • Ahn, Kyu-Hong;An, Seok;Maeng, Seung-Kyu;Kim, Ki-Pal;Hong, Joon-Seok;Jung, Min-Woo;Kweon, Ji-Hyang;Ahmed, Zubair
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.17 no.4
    • /
    • pp.542-549
    • /
    • 2003
  • In the present study, the feasibility of $UV/H_2O_2$ systems was investigated using low and medium-pressure lamps on biologically treated wastewater effluents for secondary effluent reclamation. Two types of UV lamps were used as the light sources (a 39-W low-pressure mercury lamp and a 350-W medium-pressure mercury lamp). The results from these UV systems showed that the removal of organic compounds could be achieved in the contact time of longer than 30min (i.e., low UV doses). Efficiencies of color removal and disinfection were far better than those of organic matters measured as TOC, DOC and $TCOD_{cr}$. In the low-pressure lamp UV system, it has been found that DOC and color removals were 60.9 and 86.2% with 50mg/L of $H_2O_2$ and contact times of 30 minute, respectively. Whereas, with the medium-pressure lamp UV system, TOC, DOC and color removal were 27.1, 5.6 and 95% with 14.3mg/L of $H_2O_2$ and 14 minute of contact times, respectively. Both systems could be applied for the reclamation of secondary effluent treated with biological treatment processes.

A study of seasonal variation of the residual flow before and after Saemangeum reclamation (새만금간척 전.후 잔차류의 계절변화에 관한 연구)

  • Shin, Moon-Seup;vanagi, T.;Hong, Sung-Kun;Lee, Dong-Ju
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.4 s.129
    • /
    • pp.425-442
    • /
    • 2002
  • The land reclamation area of Saemangeum(Kunsan) is located between $126^{\circ}10'\;E{\sim}126^{\circ}50'\;E\;and\;35^{\circ}35'\;N{\sim}36^{\circ}05'\;N$ at the western coast of the Korean peninsula. The reclamation area of Saemangeum has a range of 5.6m spring tide and the maximum tidal current speed is about $1.41m\;s^{-1}$. In ordinary spring tide. Most of the sediments deposited on the tidal flats are transported from the Geum river, the Mankyung river and the Dongjin river. The soil in this area consists of silty sand with the depth of 10m to 30m. The wind in winter is strong from the direction of northwest. Saemangeum coastal area is being constructed 33km the sea dike and 40,100ha reclamation area. The purpose of this study Is to find the residual circulations in four seasons before and after the dike construction by a robust diagnostic and prognostic numerical model.

Development of USLExls and its Application for the Analysis of the Impact of Soil-Filling Work on Soil Loss (USLExls를 이용한 복토법에 따른 필지 단위 토양유실량 분석)

  • Kim, Sorae;Yu, Chan;Lee, Sang-Whan;Ji, Won-Hyun;Jang, Min-Won
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.6
    • /
    • pp.109-125
    • /
    • 2017
  • This study aimed to develop a parcel-unit soil loss estimation tool embedded in Excel worksheet, USLExls, required for the design of contaminated farmland restoration project and to analyze the impact of the project carried out soil-filling work on soil loss. USLE method was adopted for the estimation of average annual soil loss in a parcel unit, and each erosivity factor in the USLE equation was defined through the review of previous studies. USLExls was implemented to allow an engineer to try out different combinations just by selecting one among the popular formulas by each factor at a combo box and to simply update parameters by using look-up tables. This study applied it to the estimation of soil loss before and after soil-filling work at Dong-a project area. The average annual soil loss after the project increased by about 2.4 times than before on average, and about 60 % of 291 parcels shifted to worse classes under the classification criteria proposed by Kwak (2005). Although average farmland steepness was lower thanks to land grading work, the soil loss increased because the inappropriate texture of the cover soil induced the soil erosion factor K to increase from 0.33 before to 0.78 after the soil-filling work. The results showed that the selection of cover soil for soil-filling work should be carefully considered in terms soil loss control and the estimation of change in soil loss should be mandatory in planning a contaminated farmland restoration project.

Removal and Recovery of Arsenic from Gold Concentrate (금(金) 정광(精鑛)내의 비소(砒素)(As) 제거(除去) 및 회수(回收)에 관한 연구(硏究))

  • Yoo, Kyoungkeun;Shin, Shun-Myung;Park, Jay Hyun;Choi, Ui Kyu;Wang, Jei-Pil
    • Resources Recycling
    • /
    • v.22 no.4
    • /
    • pp.33-37
    • /
    • 2013
  • A study on the removal of arsenic from gold concentrate was conducted using thermal decomposition method at $700^{\circ}C$ as a function of reaction time. In addition, the arsenic removed from the concentrate was also collected in the bag-filter as a form of AsS. The content of arsenic in the concentrate was dramatically decreased from 12.62 wt/% to 1.40 wt.% for 1 hour and even lower than 1 wt.% after two hours. The removal efficiency of arsenic was finally achieved to be about 95% after 2 hours at a given temperature.