• 제목/요약/키워드: RAPID

검색결과 21,269건 처리시간 0.042초

전립선특이항원검사 Kit에 의한 정액의 신속 검출법 (Forensic Evaluation of Prostate-Specific-Antigen (PSA) Rapid Test Kit for Identification of Human Semen)

  • 임채원;이종훈;김형락
    • 대한임상검사과학회지
    • /
    • 제41권2호
    • /
    • pp.76-82
    • /
    • 2009
  • It would be one of the most important tests that determination of semen in crime scene as a matter of significant evidences. Recently, it has been developed for the identification of semen in forensic specimens which was used simply, easily and reproductively. In this study, Prostate-Specific-Antigen (PSA) Rapid Test kit was evaluated for the forensic identification of semen and compared with one step semen inspection forensic rapid test kit. The sensitivity and specificity of the rapid PSA kit were examined in addition to the stability of PSA. The positive band of rapid PSA kit shown even with 1,000,000-fold diluted semen, which was at least 100 timed higher than qualitative one step semen inspection forensic rapid test kit. PSA was detected in urine from normal male adult, however, it was not detected in urine from young boys and female body fluids. It was shown that PSA was very stable to resist boiling for 20 minutes and the effect of bacteria. In crime scene investigation, rapid PSA kit is expected to help to identify semen easily in the evidences.

  • PDF

Development of cellulose nano beads based a rapid detection kit to detect staphylococcal enterotoxin B

  • Kim, Giyoung;Yoo, Jinyoung;Park, Saetbyeol
    • 농업과학연구
    • /
    • 제46권3호
    • /
    • pp.549-557
    • /
    • 2019
  • Staphylococcal enterotoxin is a very common cause of food poisoning. Conventional detection methods for the toxin including enzyme-linked immunosorbent assays (ELISAs), chemiluminescence (ECL), and polymerase chain reaction (PCR) assays require a lot of time, efforts, and expert technicians. Lateral flow strip kits have shown great potential for the rapid detection of foodborne pathogens. The lateral flow strip kit is widely used in clinical settings because it is easy to use, fast, and cost effective. A typical lateral flow strip kit uses colloidal gold to generate a visual signal. However, the lateral flow strip kit based on colloidal gold has limited sensitivity to fulfill food safety regulation requirements. This study was performed to develop a rapid test kit for pathogenic staphylococcal enterotoxin B (SEB) in food samples. The rapid detection kit was fabricated based on a nitrocellulose lateral-flow strip. Cellulose nano beads and SEB antibodies were used as the tag and receptor, respectively, to improve the detection performance. Manually spotted SEB antibody and anti-rabbit antibody on the surface of the nitrocellulose membrane were used as test and control spots, respectively. The feasibility of the rapid test kit to detect SEB in samples was evaluated. The sensitivity of the kit was 10 ng/mL SEB spiked in PBS. Additionally, the rapid test kit could detect 1 ng/mL of SEB in chicken meat extract.

신속정밀제도력과 초신속정밀궤도력을 이용한 GPS 위성좌표 계산 (Calculates of GPS Satellite Coordinates Using Rapid and Ultra-Rapid Precise Ephemerides)

  • 박정현;이용욱;이은수
    • 한국측량학회지
    • /
    • 제22권4호
    • /
    • pp.383-390
    • /
    • 2004
  • IGS는 13일 이후에 제공되는 매우 정확한 최종정밀궤도력을 제공하고 있으며, 보다 신속한 활용을 위해 신속정밀궤도력을 제공하고 있다. 그리고 실시간 활용을 위해 초신속정밀궤도력을 제공하고 있다. 본 연구에서는 최종정밀궤도력을 기준으로 신속정밀궤도력과 초신속정밀궤도력의 정확도를 분석하고, 위성의 위치결정에 필요한 Lagrange 보간법의 차수를 결정하고자 한다. 연구결과, 신속정밀궤도력의 x,y,z좌표의 평균제곱근오차는 $\pm$0.016m 정도였으며, 관측된 초신속정밀궤도력은 약 $\pm$0.024m의 오차를 나타내었다. 24시간동안의 예측 초신속정밀궤도력은 $\pm$0.07m, 6시간동안 예측된 초신속정밀궤도력은 $\pm$0.04m 정도의 오차를 나타내어 방송궤도력보다 매우 높은 정확도를 갖고 있음을 알 수 있었다. 또한, Lagrange 방법으로 위성의 위치를 계산하는 경우, 9차 다항식을 이용하는 것이 효율적임을 확인하였다.

RNCC 기반 다시기 RapidEye 위성영상의 정밀 상호좌표등록 (RNCC-based Fine Co-registration of Multi-temporal RapidEye Satellite Imagery)

  • 한유경;오재홍
    • 한국측량학회지
    • /
    • 제36권6호
    • /
    • pp.581-588
    • /
    • 2018
  • 본 연구는 다시기 영상의 활용이 유리한 RapidEye 영상의 활용성을 증대시키기 위하여, 이들 간에 지역적으로 존재하는 기하오차를 최소화 하는 정밀 상호좌표등록 기법을 제안하였다. 이를 위해, RapidEye 영상과 함께 제공되는 RPCs (Rational Polynomial Coefficients)를 이용하여 다시기 정사영상을 생성하고, 정사영상 간의 정밀 상호 좌표등록을 수행하였다. 정사영상을 생성하기 위해서 수치지도에서 추출된 DEM (Digital Elevation Model)을 활용하였으며, 정밀 상호좌표등록을 수행하기 위하여 RNCC (Registration Noise Cross Correlation) 기법을 적용하였다. 영광지역에 대해 2015년 5월부터 2016년 11월까지 획득된 RapidEye 1B 영상 총 4장을 활용하여 실험을 진행하였으며, 밴드별(blue, green, red, red edge, near-infrared)로 적용된 정밀 상호좌표등록 결과 비교분석을 통해 각 밴드가 보이는 상호좌표등록 적용 가능성 여부를 판단하였다. 실험 결과, RapidEye 영상의 모든 밴드를 활용하여 상호좌표등록이 가능하였으며, 상호좌표등록을 하지 않았을 때보다 다시기 영상 간 정량적/정성적으로 향상된 기하 일치도를 보였다. 특히 red와 red edge 밴드를 이용할 경우 다시기 영상 촬영시기의 계절적 차이에 관계없이 안정적인 상호좌표등록 결과를 보임을 확인하였다.

SLS 쾌속조형장치를 위한 고속 패킹 알고리즘 개발 (A Rapid Packing Algorithm for SLS Rapid Prototyping System)

  • 김부영;김호찬;최홍태;이석희
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.561-564
    • /
    • 2002
  • With Rapid Prototyping system, the efficient packing in a fixed work volume reduces build time when multiple parts are built in a process. In this paper, an efficient and rapid packing algorithm is developed for SLS system that has cylindrical workspace. A genetic algorithm is implemented to place as many part as possible in a vat. For fast computation, a collision detection algorithm "k-DOPs Tree" is implemented.

  • PDF

Rapid Local Modeling in Construction Automation

  • 권순욱
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2003년도 학술대회지
    • /
    • pp.173-179
    • /
    • 2003
  • Techniques to rapidly model local spaces, using 3D range data can enable implementation of: (1) real-time obstacle avoidance for improved safety, (2) advanced automated equipment control modes, and (3) as-built data acquisition for improved quantity tracking, engineering, and project control systems. The objective of the research reported here was to introduce current rapid local modeling techniques and develop rapid local spatial modeling tools.

  • PDF

자동설계 프로그램을 이용한 급속성형에 관한 연구 (A Study on the Rapid Prototyping using Automatic Design Program)

  • 김세민;이승수;김민주;주만식;전언찬
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 춘계학술대회 논문집(한국공작기계학회)
    • /
    • pp.365-370
    • /
    • 2001
  • This study is the selection of optimum forming condition for RP system using ADS. Program using ADS reduces the required time for feedback between design and manufacturing of workpiece. When we produce rapid prototype using RP system, we investigate the relationship between Facetres in system variable number of AutoCAD and circularity of rapid prototype, and we will find optimum forming condition in RP system.

  • PDF

Dosimetric comparison of volumetric modulated arc therapy with robotic stereotactic radiation therapy in hepatocellular carcinoma

  • Paik, Eun Kyung;Kim, Mi-Sook;Choi, Chul Won;Jang, Won Il;Lee, Sung Hyun;Choi, Sang Hyoun;Kim, Kum Bae;Lee, Dong Han
    • Radiation Oncology Journal
    • /
    • 제33권3호
    • /
    • pp.233-241
    • /
    • 2015
  • Purpose: To compare volumetric modulated arc therapy of RapidArc with robotic stereotactic body radiation therapy (SBRT) of CyberKnife in the planning and delivery of SBRT for hepatocellular carcinoma (HCC) treatment by analyzing dosimetric parameters. Materials and Methods: Two radiation treatment plans were generated for 29 HCC patients, one using Eclipse for the RapidArc plan and the other using Multiplan for the CyberKnife plan. The prescription dose was 60 Gy in 3 fractions. The dosimetric parameters of planning target volume (PTV) coverage and normal tissue sparing in the RapidArc and the CyberKnife plans were analyzed. Results: The conformity index was $1.05{\pm}0.02$ for the CyberKnife plan, and $1.13{\pm}0.10$ for the RapidArc plan. The homogeneity index was $1.23{\pm}0.01$ for the CyberKnife plan, and $1.10{\pm}0.03$ for the RapidArc plan. For the normal liver, there were significant differences between the two plans in the low-dose regions of $V_1$ and $V_3$. The normalized volumes of $V_{60}$ for the normal liver in the RapidArc plan were drastically increased when the mean dose of the PTVs in RapidArc plan is equivalent to the mean dose of the PTVs in the CyberKnife plan. Conclusion: CyberKnife plans show greater dose conformity, especially in small-sized tumors, while RapidArc plans show good dosimetric distribution of low dose sparing in the normal liver and body.

상악골 급속 확장 후 상악골 변화에 대한 정모두부방사선 규격사진 분석에 관한 연구 (A posteroanterior cephalometric study on the change of maxilla by rapid palatal expansion)

  • 김영준
    • 대한치과교정학회지
    • /
    • 제29권3호
    • /
    • pp.375-381
    • /
    • 1999
  • 본 연구는 상악궁이 양측성으로 협소하여 구치부 교차 교합을 보이는 환자 30 명에서 정중구개봉합 급속 확장술을 시행한 후, 정모두부방사선 규격 사진을 이용하여 상악골 기저부의 횡적 확장 여부를 확인하고, 그 양을 정량적으로 계측하여 상하악골 횡적 부조화의 개선 정도를 평가하여 다음과 같은 결과를 얻었다. 1. 정중구개봉합 급속 확장술을 시행한 경우 남녀 모두 각각 상악골 기저부의 유의성 있는 증가를 보였다. (P<0.001) 2. 정중구개봉합 급속 확장술을 시행한 후 확장량에 있어서 남녀간 유의성 있는 차이를 보이지 않았다. 3. 정중구개봉합 급속 확장술을 시행한 경우 사춘기 이전과 사춘기 이후 모두 각각 상악골 기저부의 유의성 있는 증가를 보였다. (P<0.001) 4. 정중구개봉합 급속 확장술을 시행한 후 확장량에 있어서 사춘기 이전과 이후 간에 유의성 있는 차이를 보이지 않았다.

  • PDF

중환자실에 근무하는 의료인의 전비강에서 PBP2a Rapid Kit와 직접 Coagulase 검사를 이용한 Methicillin-resistant Staphylococcus aureus의 검출 (Detection of Methicillin-resistant Staphylococcs aureus from the Anterior Nares of Healthcare Workers in a Intensive Care Unit by Using PBP2a Rapid Kit and Direct Coagulase Test)

  • 홍승복;신경아;손재철;신경섭
    • 대한임상검사과학회지
    • /
    • 제42권2호
    • /
    • pp.86-91
    • /
    • 2010
  • We evaluated the performance of a novel screening test, PBP2a MRSA rapid kit (Dinona Inc., Iksan, Korea), for methicillin-resistant Staphylococcus aureus (MRSA) based on a immunochromatographic assay. The test is able to detect penicillin-binding protein 2a (PBP2a) using the nasal specimens from health care workers. The nasal specimens were obtained from 69 healthcare workers and were incubated in enrichment broth followed eight hours incubatin in BHI with cefoxitin $4{\mu}g/mL$. These broth were tested by PBP2a Rapid Kit. The enrichment broths were also directly tested for tube coagulase using the conventional identification method. 19 of 22 MRSA showed positive results by PBP2a rapid test and direct coagulase test (the sensitivity for detection of MRSA, 86.36%). While, 8 of 47 non-MRSA showed false positive results for the two tests. All of the 8 non-MRSA which showed false positive were co-colonizing isolates with MRCNS and MSSA. In addition, 46 of 49 methicillin-resistant staphylococci (MRS) showed positive results for PBP2a MRSA rapid kit (the sensitivity for detection of MRS, 93.8%), and all of 20 non-MRS showed negative results (specificity, 100%). The combination of PBP2a MRSA rapid kit and direct coagulase test showed the good sensitivity for detection of MRSA from anterior nares but frequently showed false positive results from the co-colonizing carrier with MRCNS and MSSA.

  • PDF