• Title/Summary/Keyword: R290

Search Result 365, Processing Time 0.025 seconds

Influence of Working Fluids to Heat Transfer Characteristics of the Heat Exchanger using Oscillating Capillary Tube Heat Pipe for Low Temperature Waste Heat Recovery (저온 폐열회수용 진동세관형 히트파이프 열교환기의 작동 유체에 따른 열전달 특성)

  • 이욱현;임용빈;김정훈;김종수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.7
    • /
    • pp.659-666
    • /
    • 2000
  • Heat transfer characteristics of a heat exchanger for low temperature waste heat recovery using oscillating capillary tube heat pipe were evaluated against the charge ratio variation of working fluid and various working fluids. R-l42b, R-22 and R-290 were used as working fluids. The heat exchanger was composed of heat pipe with capillary tube bundles, having a 2.6mm in outer diameter, 1.4mm in inner diameter with 101m long, and 40 turns. Charge ratio of working fluid was 40% and 50%. Water was used as secondary fluid. Inlet temperature and mass velocity for each secondary fluid were 297 K, 280 K and9~27 kg /$m^2s$,, respectively. From experimental results, it was found that heat transfer performance of R-22 was higher than those of R-l42b and R-290 and it was proportional to Figure of merit for thermosyphons. As a result, it was thought that R-22 was the most suitable working fluid of waste heat recovery for low temperature waste heat recovery.

  • PDF

Prediction on Performance of Cascade Refrigeration System using Alternative Freon and Natural Refrigerants (대체 프레온 및 자연 냉매를 이용하는 이원 냉동시스템의 성능 예측)

  • Kim, Jong-Ryeol;Roh, Geon-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1427-1433
    • /
    • 2012
  • In this paper, cycle performance analysis of cascade refrigeration system using alternative FREON refrigerants and natural refrigerants are presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooled and superheated degree, and condensing and evaporating temperature, temperature difference of cascade heat exchanger in cascade refrigeration system. The COP of cascade refrigeration system increases with the increasing subcooled degree, but there is no significant changes with the increasing superheated degree. The COP of cascade refrigeration system depends on evaporating and condensing temperatures of cascade heat exchanger. Therefore, subcooled degree, evaporating and condensing temperature of cascade heat exchanger using alternative FREON refrigerants and natural refrigerants have an effect on the COP of this system. In this paper, COP of cascade refrigeration system using (R23 / R290), (R23 / R600), (R23 / R600a), (R23 / R717), (R744 / R404A) are higher 20 ~ 36 % than (R23 / R22), using R23 for low temperature system and R22 for high temperature system.

Condensation Heat Transfer Characteristics of Hydrocarbon Refrigerants in Horizontal Tubes of 7.73 mm and 5.80 mm (7.73 mm와 5.80 mm 수평관내 탄화수소 냉매의 응축 열전달 특성)

  • Son, Chang-Hyo
    • Journal of Hydrogen and New Energy
    • /
    • v.19 no.4
    • /
    • pp.331-339
    • /
    • 2008
  • 본 논문은 내경 7.73 mm와 5.80mm의 수평관내 프레온계 냉매 R-22와 탄화수소계 냉매 R-290과 600a의 응축 열전달 계수의 실험적 결과를 나타내었다. 실험장치는 압축기, 응축기, 팽창밸브, 증발기 등으로 구성된다. 응축 실험은 질량유속 $35.5{\sim}210.4\;kg/m^2s$이고, 응축온도 40$^{\circ}C$인 조건에서 수행하였다. 주요 결과를 요약하면 다음과 같다. 탄화수소계 냉매 R-290과 R-600a의 평균 열전달 계수는 프레온계 냉매 R-22보다 높게 나타났으며, R-600a의 평균 열전달 계수가 모든 관경에 대해 가장 높게 나타났다. 실험결과와 종래의 상관식을 비교한 결과, 모든 관경과 냉매에 대해 Haraguchi 등의 상관식이 가장 좋은 일치를 보였다. 그 중에서 Cavallini-Zecchin의 상관식은 7.73 mm 관경의 실험데이터와, Dobson 등의 상관식은 내경 5.80 mm 관경의 데이터와 좋은 일치를 보였다.

Performance Improvement on the Re-Liquefaction System of Ethylene Carrier using Low-Global Warming Potential Refrigerants (Low - Global Warming Potential 냉매를 이용한 에틸렌 수송선의 재액화 시스템 성능개선)

  • Ha, Seong-Yong;Choi, Jung-Ho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.55 no.5
    • /
    • pp.415-420
    • /
    • 2018
  • The development of sail gas has increased the production of ethane as well as natural gas. The decline in the market price for ethane has led to a change in the petroleum-based ethylene production process into an ethane-based ethylene production process and an increase in the ethane/ethylene trade volume. Large-scale ethane/ethylene carrier have been needed due to an increase in long-distance trade from the US, and cargo type change have leaded to consider a liquefaction process to re-liquefy Boil-Off gas generated during the voyage. In this paper, the liquefaction system of Liquefied Ethane Gas carrier was evaluated with Low-GWP (Low-Global Warming Potential) refrigerant and process parameters, Boil-Off Gas pressure and expansion valve outlet pressure, were optimized. Low-GWP refrigerants were propane (R290), propylene(R1270), carbon dioxide(R744) was considered at two type of liquefaction process such as Linde and cascade cycle. The results show that the optimal pressure point depends on the individual refrigerant and the highest liquefaction efficiency of carbon dioxide (R744) - propane (R290) refrigerant.

SOME PROPERTIES OF GM MODULES AND MR GROUPS

  • Cho, Yong Uk
    • Korean Journal of Mathematics
    • /
    • v.16 no.3
    • /
    • pp.281-290
    • /
    • 2008
  • The purpose of this paper, GM modules are defined as a generalization of AGR rings. Also, from the faithful GM-property, we get a commutativity of rings. Finally, for a nearring R, we will introduce MR groups, and also derive some properties of GM modules and MR groups.

  • PDF

Performance Analysis of 2-Stage Compression and 1-Stage Expansion Refrigeration System using Alternative Natural Refrigerants (암모니아 대체 자연냉매를 이용하는 2단압축 1단팽창 냉동시스템의 성능예측)

  • Roh, Geon-Sang
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.3
    • /
    • pp.42-47
    • /
    • 2012
  • In this paper, alternative natural refrigerant R290(Propane), R600(Butane), R717(Ammonia), R1270(Propylene) for freon refrigerant R22 were used working fluids for 2-stage compression and 1-stage expansion refrigeration system. The operating parameters considered in this study included evaporation temperature, condensation temperature, subcooling degree, superheating degree, mass flow rate ratio of inter-cooler. The main results were summarized as follows : The COP of 2-stage compression and 1-stage expansion refrigeration system increases with the increasing subcooling degree and mass flow rate ration of inter-cooler, but decreases with the increasing evaporating temperature, condensing temperature and superheating degree. Therefore, subcooling degree, mass flow rate ratio of inter-cooler of 2-stage compression and 1-stage expansion refrigeration system using natural refrigerants have an effect on COP of this system. The COP of natural refrigerants was higher than the COP of freon R22 in this study, so points to be considered are the security, the attached facilities for natural refrigerants than COP.

A Study on User Authentication based on Keystroke Dynamics of Long and Free Texts (자유로운 문자열의 키스트로크 다이나믹스를 활용한 사용자 인증 연구)

  • Kang, Pil-Sung;Cho, Sung-Zoon
    • IE interfaces
    • /
    • v.25 no.3
    • /
    • pp.290-299
    • /
    • 2012
  • Keystroke dynamics refers to a way of typing a string of characters. Since one has his/her own typing behavior, one's keystroke dynamics can be used as a distinctive biometric feature for user authentication. In this paper, two authentication algorithms based on keystroke dynamics of long and free texts are proposed. The first is the K-S score, which is based on the Kolmogorov-Smirnov test, and the second is the 'R-A' measure, which combines 'R' and 'A' measures proposed by Gunetti and Picardi (2005). In order to verify the authentication performance of the proposed algorithms, we collected more than 3,000 key latencies from 34 subjects in Korean and 35 subjects in English. Compared with three benchmark algorithms, we found that the K-S score was outstanding when the reference and test key latencies were not sufficient, while the 'R-A' measure was the best when enough reference and test key latencies were provided.

Association between PCR-RFLP of Melatonin Receptor 1a Gene and High Prolificacy in Small Tail Han Sheep

  • Chu, M.X.;Ji, C.L.;Chen, G.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.12
    • /
    • pp.1701-1704
    • /
    • 2003
  • Melatonin regulates circadian rhythms and reproduction changes in seasonally reproductive mammals through binding to high-affinity, G-protein-coupled receptors. Small Tail Han sheep that has significant characteristics of high prolificacy and nonseasonal ovulatory activity is an excellent local sheep breed in P. R. China. The exon 2 of the ovine melatonin receptor 1a (MTNR1A) gene was amplified and a uniform fragment of 824 bp was obtained in 150 ewes of Small Tail Han sheep. The 824 bp PCR product was digested with restriction endonucleases Mnl I and Rsa I, and genetic polymorphism was detected by PCR-RFLP. Polymorphic Mnl I site was detected at base position 605 of the exon 2 of the MTNR1A gene. There were two kinds of genotypes in Small Tail Han sheep, AB (303 bp, 236 bp/67 bp) and BB (236 bp/67 bp, 236 bp/67 bp). The results indicated that genotype AA (303 bp, 303 bp) at Mnl I-RFLP site did not exist in non-seasonal estrous Small Tail Han sheep, which suggested that there was an association between genotype AA (303 bp, 303 bp) and reproductive seasonality in sheep. Polymorphic Rsa I site was detected at base position 604 of the exon 2 of the MTNR1A gene. Three kinds of genotypes were found in Small Tail Han sheep, AA (290 bp, 290 bp), AB (290 bp, 267 bp/23 bp) and BB (267 bp/23 bp, 267 bp/23 bp). Least squares means of litter size in the first parity and the second parity for genotype AA (290 bp, 290 bp) at Rsa I-RFLP site were 0.43 and 1.06 more than those for genotype AB (290 bp, 267 bp/23 bp) in Small Tail Han sheep.