• Title/Summary/Keyword: R2-loop

Search Result 283, Processing Time 0.021 seconds

Cooling Heat Transfer Characteristics of Carbon Dioxide in a Horizontal and Helically Coiled Tube (수평관과 헬리컬 코일관내 이산화탄소의 냉각 열전달 특성)

  • Son, Chang-Hyo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.1
    • /
    • pp.121-126
    • /
    • 2008
  • The cooling heat transfer coefficient of $CO_2$ (R-744) in a horizontal and helically coiled tube was investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater, evaporator and gas cooler (test section). The test section consists of a horizontal stainless steel tube and hellically coiled copper tube of 4.57 and 7.75 mm. The experiments were conducted at saturation temperature of 100 to $20^{\circ}C$, and mass flux of 200 to $500kg/m^2s$. The test results showed the variation of the heat transfer coefficient tended to decrease as cooling pressure of $CO_2$ increased. The heat transfer coefficient with respect to mass flux increased as mass flux increased. The experimental results were also compared with the existing correlations for the supercritical heat transfer coefficient, which generally underpredicted the measured data. However, the experimental data showed a relatively good agreement with the correlations of Pitla et al. except for the pseudo critical temperature.

He I D3 and 10830 observations of the flare-productive active region AR 12673 on 2017 September 7

  • Kim, Yeon-Han;Xu, Yan;Kim, Sujin;Bong, Su-Chan;Lim, Eun-Kyung;Yang, Heesu;Yurchyshyn, Vasyl;Ahn, Kwangsu;Park, Young-Deuk;Goode, Phillip R.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.46.2-46.2
    • /
    • 2018
  • The active region NOAA AR 12673 is the most flare productive active region in the solar cycle 24. On 2017 September 07, it produced an X1.3 flare, three M-class, and several C-class flares. We successfully observed several C-class flares from 16:50 UT to 22:00 UT using the 1.6m Goode Solar Telescope (GST; formerly NST) at Big Bear Solar Observatory (BBSO). The GST provides us with unprecedented high-resolution data of the Sun since 2009. Interestingly, we observed the active region in He I D3 and 10830 lines simultaneously. The data shows several interesting features: (1) D3 emission seems to be much weaker than 10830 emission around 21:29 UT; (2) a small loop seen in 10830 is moving upward and is brightened around 21:16 UT, but it is not clear in D3; (3) there are waves in the penumbra seen in 10830 line center; (4) there is a jet with twisting motion. In this presentation, we will give the results of our analysis and interpretations.

  • PDF

Calibration of frequency propagation channel sounder based on five-port reflectometer

  • Yem Van;Braga Judson;Huyart B;Begaud X;de Sousa F.R;Huyen Nguyen Bich
    • Proceedings of the IEEK Conference
    • /
    • summer
    • /
    • pp.23-26
    • /
    • 2004
  • Five-port reflectometer which consists of a ring with 5 arms (two inputs, three outputs) and three RF power detectors has been used as a vector network analyser, a demodulator in the homodyne receiver as well as in Phase Looked Loop (PLL) and so on. Calibration of five-port reflectometer is an important task. In this paper, we present a calibration method of five-port for a propagation channel sounder. The method is based on measurement of the phase differences between the three voltages at the five-port's outputs in order to determine the ratio of two input incident waves. The frequency channel sounder based on five-port is calibrated for each frequency from 2.2 GHz to 2.6 GHz with 1 MHz step. This method can also determine the absolute delays of each propagation path in the propagation channel. The calibration method is validated using measurement data.

  • PDF

Overcoming OBI Problem by Means of Heterodyne Detection in Upstream Transmission of WDM/SCM-PON (WDM/SCM-PON의 상향 전송에서 헤테로다인 방식을 이용한 광간섭잡음 문제 극복방안 연구)

  • Jeon, You-Chan;Shin, Hong-Seok;Park, Jin-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.2A
    • /
    • pp.202-208
    • /
    • 2010
  • The performance of upstream transmission in SCM-PON is generally limited by the presence of OBI which is caused by the beating of two or more lasers. In this paper, we propose a novel approach for reducing OBI problem by using heterodyne detection with an additional LD as a local oscillator, resulting that the RF signal is shifted to the other spectal band. In addition, it is possible that the proposed method can provide the cost-effective solution thanks to the loop-back mechanism using R-SOA in ONUs. The performance is superior when the spectral width of LD is smaller and the power difference between the transmission LD and the oscillation LD is bigger. System configuration and design consideration are discussed. Performance of the systems is evaluated by simulator called OptSim. It is expected to provide WDM/SCM-PON system not only cost-effective but also efficient in increasing the number of subscribers.

A Study on the Condensation Heat Transfer and Pressure Drop in Internally Grooved Tubes Used in Condenser (응축기용 낮은 핀관의 내부 나선 홈에 의한 응축 열전달 성능과 압력손실에 관한 연구)

  • Han, Kyuil;Cho, Dong-Hyun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.2
    • /
    • pp.212-222
    • /
    • 1998
  • Heat transfer performance improvement by fin and groovs is studied for condensation of R-11 on integral-fin tubes. Eight tubes with trapczodially shaped integral-fins having fin density from 748 to 1654fpm(fin per meter) and 10, 30 grooves are tested. A plain tube having the same diameter as the finned tubes is also used for comparison. R-11 condensates at saturation state of 32 $^{\circ}C$ on the outside tube surface coded by inside water flow. All of test data are taken at steady state. The heat transfer loop is used for testing singe long tubes and cooling is pumped from a storage tank through filters and folwmeters to the horizontal test section where it is heated by steam condensing on the outside of the tubes. The pressure drop across the test section is measured by menas pressure gauge and manometer. The results obtained in this study is as follows : 1. Based on inside diameter and nominal inside area, overall heat transfer coefficients of finned tube are enhanced up to 1.6 ~ 3.7 times that of a plain tube at a constant Reynolds number. 2. Friction factors are up to 1.6 ~ 2.1 times those of plain tubes. 3. The constant pumping power ratio for the low integral-fin tubes increase directly with the effective area to the nominal area ratio, and with the effective area diameter ratio. 4. A tube having a fin density of 1299fpm and 30 grooves has the best heat transfer performance.

  • PDF

Comparison of effect of desensitizing agents on the retention of crowns cemented with luting agents: an in vitro study

  • Jalandar, Sonune Shital;Pandharinath, Dange Shankar;Arun, Khalikar;Smita, Vaidya
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.3
    • /
    • pp.127-133
    • /
    • 2012
  • PURPOSE. Many dentists use desensitizing agents to prevent hypersensitivity. This study compared and evaluated the effect of two desensitizing agents on the retention of cast crowns when cemented with various luting agents. MATERIALS AND METHODS. Ninety freshly extracted human molars were prepared with flat occlusal surface, 6 degree taper and approximately 4 mm axial length. The prepared specimens were divided into 3 groups and each group is further divided into 3 subgroups. Desensitizing agents used were GC Tooth Mousse and $GLUMA^{(R)}$ desensitizer. Cementing agents used were zinc phosphate, glass ionomer and resin modified glass ionomer cement. Individual crowns with loop were made from base metal alloy. Desensitizing agents were applied before cementation of crowns except for control group. Under tensional force the crowns were removed using an automated universal testing machine. Statistical analysis included one-way ANOVA followed by Turkey-Kramer post hoc test at a preset alpha of 0.05. RESULTS. Resin modified glass ionomer cement exhibited the highest retentive strength and all dentin treatments resulted in significantly different retentive values (In Kg.): GLUMA ($49.02{\pm}3.32$) > Control ($48.61{\pm}3.54$) > Tooth mousse ($48.34{\pm}2.94$). Retentive strength for glass ionomer cement were GLUMA ($41.14{\pm}2.42$) > Tooth mousse ($40.32{\pm}3.89$) > Control ($39.09{\pm}2.80$). For zinc phosphate cement the retentive strength were lowest GLUMA ($27.92{\pm}3.20$) > Control ($27.69{\pm}3.39$) > Tooth mousse ($25.27{\pm}4.60$). CONCLUSION. The use of $GLUMA^{(R)}$ desensitizer has no effect on crown retention. GC Tooth Mousse does not affect the retentive ability of glass ionomer and resin modified glass ionomer cement, but it decreases the retentive ability of zinc phosphate cement.

Design of Video Encoder activating with variable clocks of CCDs for CCTV applications (CCTV용 CCD를 위한 가변 clock으로 동작되는 비디오 인코더의 설계)

  • Kim, Joo-Hyun;Ha, Joo-Young;Kang, Bong-Soon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.1
    • /
    • pp.80-87
    • /
    • 2006
  • SONY corporation preoccupies $80\%$ of a market of the CCD used in a CCTV system. The CCD of SONY have high duality which can not follow the progress of capability. But there are some problems which differ the clock frequency used in CCD from the frequency used in common video encoder. To get the result by using common video encoder, the system needs a scaler that could adjust image size and PLL that synchronizes CCD's with encoder's clock So, this paper proposes the video encoder that is activated at equal clock used in CCD without scaler and PLL. The encoder converts ITU-R BT.601 4:2:2 or ITU-R BT.656 inputs from various video sources into NTSC or PAL signals in CVBS. Due to variable clock, property of filters used in the encoder is automatically changed by clock and filters adopt multiplier-free structures to reduce hardware complexity. The hardware bit width of programmable digital filters for luminance and chrominance signals, along with other operating blocks, are carefully determined to produce hish-quality digital video signals of ${\pm}1$ LSB error or less. The proposed encoder is experimentally demonstrated by using the Altera Stratix EP1S80B953C6ES device.

The Korean Defense Industry System and Its Policy Leverages (한국 방위산업의 시스템과 정책 레버리지)

  • Seo, Hyeok;Myung, Geon-Seek
    • Korean System Dynamics Review
    • /
    • v.8 no.2
    • /
    • pp.83-114
    • /
    • 2007
  • The Korean defense industry was brought up in the government policy since 1970's. The important parts of defense industrial technologies have not been developed, and usually introduced from overseas. Moreover, the development of advanced technologies was not actively stimulated or pursued, consequently shaping the current structure of the defense industry which lacks global competitiveness due to the dearth of high technologies necessary for high-technology weapons. This research analyzes the systems of the Korean defense industry through a systems thinking approach in order to understand the whole mechanism and to find ways to improve the defense industry. Finding some leverages is the main purpose of systems thinking, that yields desirable results with a little effort. The three policy leverages are: (1) the policy for timely fielding; (2) the R&D investment for development and production of domestic high-technology weapons; and (3) the policy measures for exports. The research findings will contribute to the invigorating and developing the Korean defense industry by providing policy-makers and acquisition practitioners with systematic understanding and insight into the dynamics of the defense industry for them to make and execute efficient policies taking into account the Korean overall defense industry.

  • PDF

Effect of Dissolved Oxygen (DO) on Internal Corrosion of Water Pipes

  • Jung, Hae-Ryong;Kim, Un-Ji;Seo, Gyu-Tae;Lee, Hyun-Dong;Lee, Chun-Sik
    • Environmental Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.195-199
    • /
    • 2009
  • A series of laboratory-scale corrosion experiments was carried out to observe the effect of dissolved oxygen (DO) in the presence of other water quality parameters, such as hardness, Cl-, and pH using various pipe materials. In addition, a simulated loop system was installed at a water treatment plant for pilot-scale experiment. Laboratory-scale experiment showed that corrosion rates for galvanized steel pipe (GSP), carbon steel pipe (CSP), and ductile cast iron pipe (DCIP) were decreased to 72%, 75%, and 91% by reducing DO concentration from 9${\pm}$0.5 mg/L to 2${\pm}$0.5 mg/L. From the pilot scale experiment, it was further identified that the average ionization rate of zinc in GSP decreased from 0.00533 to 0.00078 mg/$cm^2$/d by controlling the concentration of DO. The reduction of average ionization rate for copper pipe (CP) and stainless steel pipe (SSP) were 71.4% for Cu and 63.5% for Fe, respectively. From this study, it was concluded that DO could be used as a major parameter in controlling the corrosion of water pipes.

Study on the Coercive Field Strenght Noise Depends on The Magnetic Field Annealing Effect of Amorphous Ribbon (비정질 리본의 자기장중 열처리에 의한 보자력 노이즈의 변화에 관한 연구)

  • 최근화;손대락
    • Journal of the Korean Magnetics Society
    • /
    • v.4 no.2
    • /
    • pp.150-153
    • /
    • 1994
  • Magnetic field annealing method has been used to obtain proper hysteresis loop shapes which are useful to a device using amorphous ribbon. In this study, two pairs of Helmhotz coils were used to apply longitudinal and transverse magnetic field during annealing. For the measurement of coercive field strength noise which depends on magnetic field annealing, Co-based amorphous alloy ribbon $VITROVAC^{\circledR}$ 6030 was used. For the sample which was annealed under dc transverse and dc longitudinal magnetic field, coercive field strength noise was nearly independent of magnetizing frequency ranging from 1 to 100 kHz, but dc transverse and ac longitudinal magnetic fields annealed samples show that the coercive field strength noise decreased in power of magnetizing frequency. When magnetic domain nucleation occurred, the coercive field strength noise increased remarkably and decreased in power of magnetizing frequency.

  • PDF