References
- Snoeyink, V. L. and Wagner, I., Internal Corrosion of Water Distribution Systems: Principle of Corrosion of Water Distribution Systems, 2nd ed., American Water Works Association, Denver, USA, pp. 1-2 (1996).
- Mullen, E. D. and Ritter, J. A., “Potable-Water Corrosion Control,” J. Am. Water Works Assoc., 66(8), 473-474 (1974).
- Lane, R. W., Control of Scale and Corrosion in Building Water System, McGraw-Hill, NY, pp. 11-20 (1993).
- Seo, G. T., Jung H., Lee, H. D., Chung W. S., and Gee, C. S., “Characteristics of Water Quality Parameters on Enhancing and Inhibiting Corrosion in Water Distribution System (Korean),” J. Korean Soc. Environ. Eng., 20(8), 1151-1160 (1998).
- Sarin, P., Snoeyink, V. L., Bebee, J., Jim, K. K., Beckett, M. A., Kriven, W. M., and Clement, J. A., “Iron release from corroded iron pipes in drinking water distribution systems: effect of dissolved oxygen,” Water Res., 38, 1259- 1269 (2004). https://doi.org/10.1016/j.watres.2003.11.022
- Merkel, T. H., Groβ, H.-J., Werner, W., Dahlke, T., Reicherter, S., Beuchle, G., and Eberle, S. H., “Copper corrosion by-product release in long-term stagnation experiments,” Water Res., 36, 2547-1555 (2002). https://doi.org/10.1016/S0043-1354(01)00482-1
- Stumn, W. and Morgan, J. J., Aquatic chemistry: Chemical equilibria and rates in natural waters, 3rd ed, Wiley, NY, pp. 373-377, 370-373 (1996).
- Trussell, R. R. and Wagner, I., Internal Corrosion of Water Distribution Systems: Corrosion of Galvanized pipe, 2nd ed, American Water Works Association, Denver, USA, pp. 98-99 (1996).
- Furguson, J. F., Franqué, O. V., and Shock, M. R., Internal Corrosion of Water Distribution Systems, 2nd ed, American Water Works Association, Denver, USA, pp. 233-235 (1996).
Cited by
- Corrosion of Water Pipes: a Comprehensive Study of Deposits vol.11, pp.05, 2012, https://doi.org/10.4236/jmmce.2012.115034
- Effects of advanced treatments using granular activated carbon adsorption with ozonation and ultrafiltration on chlorine decay vol.52, pp.4-6, 2014, https://doi.org/10.1080/19443994.2013.827319
- Distribution system water age can create premise plumbing corrosion hotspots vol.187, pp.9, 2015, https://doi.org/10.1007/s10661-015-4747-4
- Preliminary Investigation of the Corrosion Behavior of Proprietary Micro-alloyed Steels in Aerated and Deaerated Brine Solutions vol.26, pp.12, 2017, https://doi.org/10.1007/s11665-017-3031-x
- A corrosion evaluation of mild carbon steel in reclaimed refinery stripped sour water vol.272, pp.None, 2009, https://doi.org/10.1016/j.jenvman.2020.111080
- Analysis of early failure of galvanised borewell pipe vol.133, pp.None, 2009, https://doi.org/10.1016/j.engfailanal.2021.105957