• Title/Summary/Keyword: R-test

Search Result 10,557, Processing Time 0.04 seconds

Antigenicity test of cis-Malonato[(4R,5R)-4,5-bis(aminomethyl)-2-isopropyl-1,3-dioxolane]platinum(II)(SKI 2053R) in Guinea Pigs and Mice (기니픽 및 마우스에서 cis-Malonato[(4R,5R)-4,5-bis(aminomethyl)-2-isopropyl-1,3-dioxolane]platinum(II)(SKI 2053R)의 항원성시험)

  • Lee, Yong-Soon;Kang, Kyung-Sun;Shin, Dong-Jin;Kim, Hyoung-Ook;Cho, Jae-Jin;Kim, Bae-Hwan;Nam, Ki-Hoan;Seo, Kwang-Won
    • Toxicological Research
    • /
    • v.8 no.2
    • /
    • pp.255-263
    • /
    • 1992
  • SKI 2053R and SKI 2053R-human serum albumin(HSA) mixture were examined for their antigenicity in Hartley guinea pigs as well as C57BL/6 mice in comparison with distilled water (DW), HSA and DW-HSA conjugate. Several antigenicity tests, including acitive systemic anaphylaxis(ASA), passive systemic anaphylaxis (PSA), passive cutaneous anaphylaxis (PCA) and indirect hamagglutination test (IHA), were performed according to the Established Regulations of National Institute of Safety Research. The results were as follows: 1. When guinea pigs were sensitized with SKI2053R or SKI2053R-HSA emulsified with complete Freund's adjuvant(CFA), these animals showed negative reactions in ASA and PSA. 2.No blue spot was observed on the back skin of guinea pigs in the PCA test. 3. Sera from guinea pigs revealed a negative reaction in IHA. 4.Guinea pigs were sensitized by HSA emulsified with CFA as a positive control, and these animals showed positive reactions in ASA, PSA, PCA, and IHA. As shown above, SKI2053R was considered to possess neither antigenic, nor haptenic properties, and confirmed not to have the haemagglutinating activity.

  • PDF

An Evaluation of Aging Degradation Damage for Cr-Mo-V Steel by Electrochemical Potentiokinetic Reactivation Test (재활성화 분극시험에 의한 Cr-Mo-V강의 시효열화 손상 평가)

  • Kwon, Il-Hyun;Na, Sung-Hun;Song, Gee-Wook;Yu, Hyo-Sun
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.49-54
    • /
    • 2000
  • Cr-Mo-V steel is widely used as a material for the turbine structural component in fossil power plants. It is well known that this material shows the various material degradation phenomenons such as temper embrittlement, carbide coarsening. and softening etc. or ins to the severe operation conditions as high temperature and high pressure. These deteriorative factors cause tile change of mechanical properties as reduction of fracture toughness. Therefor it is necessary to evaluate tile extent of degradation damage for Cr-Mo-V steel in life assessment of turbine structural components. In this paper. the electrochemical potentiokinetic reactivation(EPR) test in $50wt%-Ca(NO_3)_2$ solution is performed to develop the newly technique for degradation damage evaluation of Cr-Mo-V steel. The results obtained from the EPR test are compared with those in small punch(SP) tests recommended by semi-nondestructive testing method using miniaturized specimen. The evaluation parameters used in EPR test are tile reactivation current density$(I_R)$ and charge$(Q_{RC})$ reactivation rate$(I_R/I_{Crit},\;Q_R/Q_{Crit})$. The results suggest that $I_R/I_{Crit}$ in these parameters shows a good correlation with SP test results.

  • PDF

The Primality Test (소수 판별법)

  • Lee, Sang-Un;Choi, Myeong-Bok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.8
    • /
    • pp.103-108
    • /
    • 2011
  • Generally, Miller-Rabin method has been the most popular primality test. This method arbitrary selects m at k-times from m=[2, n-1] range and (m,n)=1. Miller-Rabin method performs $k{\times}r$ times and reports prime as $m^d\;{\equiv}\;1(mod\;n)$ or $m^{2^rd}\;{\equiv}\;-1(mod n)$ such that n-1=$2^sd$, $0\;{\leq}\;r\;{\leq}\;s-1$. This paper suggests more simple primality test than Miller-Rabin method. This test method computes c=$p^{\frac{n-1}{2}}(mod\;n)$ for k times and reports prime as c=-1. The proposed primality test method reduces $k{\times}r$ times of Miller-Rabin method to k times.

Correlation between Balance and Lower Extremity Muscle Activity in Stroke Patients (뇌졸중 환자의 균형과 하지 근활성도와의 상관관계 연구)

  • Yang, Dae-Jung;Kim, Je-Ho;Jung, Yong-Sik;Uhm, Yo-Han;Park, Seung-Kyu
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.10 no.1
    • /
    • pp.1-5
    • /
    • 2012
  • Purpose : In this study, stroke patients' limits of stability and functional reach test and tibialis anterior, gastrocnemius muscle of lower extremity muscle activities to evaluate the correlation. Methods : 30 adult stroke patients to participate in this study. Limits of stability were measured using biorescue, tibialis anterior and gastrocnemius muscle of muscles activities were measured with functional reach test when there was movement. Results : Limits of stability and functional reach test (r=0.753, p<0.01), RMS value of the limits of stability and tibialis anterior muscle (r=0.706, p<0.01), RMS value of the limits of stability and gastrocnemius muscle (r=0.766, p<0.01), RMS value of the functional reach test and tibialis anterior muscle (r=0.835, p<0.01), RMS value of the functional reach test and gastrocnemius muscle (r=0.663, p<0.01), RMS value of the tibialis anterior and gastrocnemius muscle (r=0.816, p<0.01) correlations are shown as statistically significant. Conclusion : The balance and lower extremity muscle activities of stroke patients were studied, and were positively correlated with the RMS value of the limits of stability and functional reach test, tibialis anterior muscle, and gastrocnemius muscle. This study has shown that stroke patients' ankle joint muscle activity can greatly.

Reliability of joint angle during sit-to-stand movements in persons with stroke using portable gait analysis system based wearable sensors

  • An, Jung-Ae;Lee, Byoung-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.8 no.3
    • /
    • pp.146-151
    • /
    • 2019
  • Objective: The purpose of this study was to investigate the test-retest reliability and concurrent validity of the joint angle of the lower extremities during sit-to-stand movements with wearable sensors based on a portable gait analysis system (PGAS), and the results were compared with a analysis system (MAS) to predict the clinical potential of it. Design: Cross-sectional study. Methods: Sixteen persons with stroke (9 males, 7 females) participated in this study. All subjects had the MAS and designed PGS applied simultaneously and eight sensor units of designed PGAS were placed in a position to avoid overlap with the reflexive markers from MAS. The initial position of the subjects was 90º of hip, knee, and ankle joint flexion while sitting on a chair that was armless and backless. The height of the chair was adjusted to each individual. After each trial, the test administrator checked the quality of data from both systems that measured sit-to-stand for test-retest reliability and concurrent validity. Results: As a result, wearable sensor based designed PGAS and MAS demonstrated reasonable test-retest reliability for the assessment of joint angle in the lower extremities during sit-to-stand performance. The intra-class correlation coefficients (ICCs) for wearable sensor based designed PGAS showed an acceptable test-retest reliability, with ICCs ranging from 0.759 to 0.959. In contrast, the MAS showed good to excellent test-retest reliability, with ICCS ranging from 0.811 to 0.950. In concurrent validity, a significant positive relationship was observed between PGAS and MAS for variation of joint angle during sit-to-stand movements (p<0.01). A moderate to high relationship was found in the affected hip (r=0.665), unaffected hip (r=0.767), affected knee (r=0.876), unaffected knee (r=0.886), affected ankle (r=0.943) and unaffected ankle (r=0.823) respectively. Conclusions: The results of this study indicated that wearable sensor based designed PGAS showed acceptable test-retest reliability and concurrent validity in persons with stroke for sit-to-stand movements and wearable sensors based on developed PGAS may be a useful tool for clinical assessment of functional movement.

Flow Condensation Heat Transfer of R22, R134a, R407C, and R410A in Plain and Microfin Tubes (평관과 마이크로 핀관 내 R22, R134a, R407C, R410A의 흐름응축 열전달성능)

  • 조영목;박기호;송길흥;정동수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.8
    • /
    • pp.656-663
    • /
    • 2002
  • Flow condensation heat transfer coefficients (HTCs) of R22, R134a, R407C, and R410A were measured on horizontal plain and microfin tubes. The experimental apparatus was composed of three main parts; a refrigerant loop, a water loop and a water/glycol loop. The test section in the refrigerant loop was made of both a plain and a microfin copper tube of 9.52 mm outside diameter and 1.0 m length. The refrigerant was cooled by passing cold water through an annulus surrounding the test section. Tests were performed at a fixed refrigerant saturation temperature of $40^{\circ}C$ with mass fluxes of 100, 200, and 300 kg/$m^2s$. Test results showed that at similar mass flux the flow condensation HTCs of R134a were similar to those of R22 for both plain and microfin tubes. On the other hand, HTCs of R407C were lower than those of R22 by 11~l5% and 23~53% for plain and microfin tubes respectively. And HTCs of R410A were similar to those of R22 for a plain tube but lower than those of R22 by 10~21% for a microfin tube. In general, HTCs of a microfin tube were 2.0~3.0 times higher than those of a plain tube.

Launch and Early Orbit Phase Simulations by using the KOMPSAT Simulator

  • Lee, Sanguk;Park, Wan-Sik;Lee, Byoung-sun;Lee, Ho-Jin;Park, Hanjun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.33-36
    • /
    • 1999
  • The KOMPSAT, which is scheduled to be launched by Taurus launch vehicle in late November of 1999, will be in a sun-synchronous orbit with an altitude of 685km, eccentricity of 0.001, inclination of 98deg and local time of ascending node of 10:50 a.m. Electronics and Telecommunications Research Institute and Daewoo Heavy Industry had jointly developed a KOMPSAT Simulator as a component of the KOMPSAT Mission Control Element. The MCE had been delivered to Korea Aerospace Research Institute for the KOMPSAT ground operation. It is being used for training of KOMPSAT ground station personnel. Each of satellite subsystems and space environment were mathematically modeled in the simulator. To verify the overall function of KOMPSAT simulator, a Launch and Early Orbit Phase(LEOP) operation simulations have been performed. The simulator had been verified through various tests such as functional level test, subsystem test, interface test, system test, and acceptance test. In this paper, simulation results for LEOP operations to verify flight software adapted into simulator, satellite subsystem models and environment models are presented.

  • PDF

Manufacture of High-temperature High-pressure Vessel for Mixed Gas Performance Test via Optimized Design (최적화 설계를 통한 혼합가스 성능시험용 고온 고압 용기의 제작)

  • Ku, Hyoun-Kon;Ryu, Hyung-Min;Ahn, Jae-Woong;Bae, Young-Gwan;Kim, Jin-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.11
    • /
    • pp.83-88
    • /
    • 2019
  • In this study, the high-temperature high-pressure vessel was successfully manufactured, which can be used to store pressurized air and to increase the temperature for the mix performance test of high-temperature high-pressure air with coolant (e.g., water). In this research, static structure analysis and transient thermal analysis were performed using the commercial software Midas NFX 2015 R1. Based on the results, the optimized pressure vessel design was carried out. As a result of the optimized design, the minimum stress and minimum weight were found at 120 mm of the vessel thickness, and the optimized pressure vessel was verified. Finally, through manufacture and performance test (e.g., the non-destructive inspection and hydraulic pressure test), the reliability and safety were validated for the designed pressure vessel.

A Study on the Antigen Characteristics of Rhodotorula rubra (Rhodotorula rubra의 항원특성에 관한 연구)

  • Kwon, Hyuk-Ku;Lee, Jang-Hoon;Ryeon, Kon
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.5
    • /
    • pp.28-34
    • /
    • 2002
  • Antigenicity of Rhodotrula rubra isolated from pulmonary tissue of pulmonary tuberculosis patients was studied by means of agglutination reaction with R. rubra whole cell antiserum. And the serological reactivity of crude polyfac charide from R. frubra, Candida albicans, Candida tropicalis, Candida, glabrata, and Saccharomyces cerevisiae ATCC 26603 with antiserum to R. rubra whole cell was studied by means of immunodiffusion test. R. rubra showed stationary phase after 48h when it was cultured in GYEP broth. While agglutinogen titer was 1:64 at lag phase, agglutinogen titer was 1 :256 after 20h. After growth of R. rubra on different 11 media, nutritional environment showed similar agglu-tination reartivity. The agglutinogen titer of C. albicans, C. tropicalis, C. giabrata, which were isolated from patient's expectoration, to R. rubra antiserum by means of agglutination reaction were 1:16, respectively. But, Sacch. cervisiae ATCC26603 was negative. Those results were lower than that of R. rubra agglutinogen titer 1:256. As a result of immu-nodiffusion test with crude polysaccharide extracted from cell wall of R. rubra, C. albicans, C. tropicalis, C. glabrata, Sacch. cervisiae ATCC26603, precipitin line was found only with R. rubra, of which antibody titer was 8.

Image Sticking Evaluation Methods for OLED TV Applications

  • Lee, Hun-Jung;Choi, Dong-Wook;Lee, Eun-Jung;Kim, Su-Young;Shin, Mi-Ok;Yang, Sun-A;Lee, Seung-Bae;Lee, Han-Yong;Berkeley, Brian H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1077-1080
    • /
    • 2009
  • In this paper, we propose a new method for measuring image sticking of an OLED display using a human visual test. We determined that the perceptual image sticking threshold is 2% of luminance difference at 200 nits and 1% at 100 nits, respectively. Color shift must also be considered when evaluating image sticking, as a ${\Delta}$(u', v') shift of just over 0.002 can be recognized regardless of background brightness. Perception of image sticking is affected by the background level, test pattern, and ambient illumination conditions. The evaluation standard must consider both luminance variation and color shift simultaneously.

  • PDF