• Title/Summary/Keyword: R-Peak

Search Result 1,514, Processing Time 0.03 seconds

Isolated word recognition using binary pattern (이치화 패턴을 이용한 고립단어 음성인식)

  • Ryoo, J.H.;Lee, Y.J.;Park, C.K.;Kim, Y.H.;Kim, K.T.
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1602-1605
    • /
    • 1987
  • This paper describes the isolated word recognition using binary patterns denoting the presence or absence of a local peak at a particular channel. In closed test, 81.3% and 76.8% of correct recognition rate were achieved in case of 10 males and 10 females with each 1588 test samples.

  • PDF

Dynamic Response Analysis of R/C Frame Structures Using High-Strength Concrete (고강도 콘크리트를 사용한 R/C 평면골조의 동적응답해석)

  • 장극관;황정현;방세용
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.04a
    • /
    • pp.278-286
    • /
    • 2001
  • The purpose of this paper is to suggest an analytical technique for time history analysis of R/C frame structure using high-strength concrete under seismic loading. Current researches in hysteretic model of structral elements using high-strength concrete are not enough. It is the cause of error that apply hysteretic model of element using normal-strength concrete to the inelastic analysis of high-strength concrete R/C frame structures. In this paper time history analysis using IDARC and DRAIN programs was performed for a 2-bay, 20-story R/C frame structures. Particularly nonlinear dynamic analysis was performed by IDARC program that was applied hysteretic model of structural element using high-strength concrete. centro earthquake 1940 NS waves was used in the analysis and its peak ground accelerations are changed to be 0.12g, 0.25g

  • PDF

Fabrication and Test of the 3.8 ㎸ Resistive SFCL Based on YBCO Films (3.8 ㎸급 7직렬 저항형 고온초전도한류기의 제작 및 시험)

  • 심정욱;김혜림;현옥배;박권배;이방욱;강종성;오일성
    • Progress in Superconductivity
    • /
    • v.5 no.2
    • /
    • pp.136-140
    • /
    • 2004
  • We fabricated and tested a resistive superconducting fault current limiters (SFCL) operated at 3.8 ㎸ based on YBCO thin films. The SFCL was composed of 7 components connected in series. Each component was designed to be capable of current limiting at 600 V, and has a SiC shunt resistor ( $R_{s}$) of 40 Ω in Parallel. Short circuit tests were carried out fur 0 and 90 degree faults lasting fur 5 cycles. The test results showed that the 7 components were quenched simultaneously under the safe quenches and evenly shared the applied voltage. The SFCL successfully suppressed the fault currents below 94 $A_{peak}$ within the quarter cycle after fault.t.t.

  • PDF

Cardiac Disease Detection Using Modified Pan-Tompkins Algorithm

  • Rana, Amrita;Kim, Kyung Ki
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.13-16
    • /
    • 2019
  • The analysis of electrocardiogram (ECG) signals facilitates the detection of various abnormal conditions of the human heart. The QRS complex is the most critical part of the ECG waveform. Further, different diseases can be identified based on the QRS complex. In this paper, a new algorithm based on the well-known Pan-Tompkins algorithm has been proposed. In the proposed scheme, the QRS complex is initially extracted by removing the background noise. Subsequently, the R-R interval and heart rate are calculated to detect whether the ECG is normal or has some abnormalities such as tachycardia and bradycardia. The accuracy of the proposed algorithm is found to be almost the same as the Pan-Tompkins algorithm and increases the R peak detection processing speed. For this work, samples are used from the MIT-BIH Arrhythmia Database, and the simulation is carried out using MATLAB 2016a.

Correlation between Lower Extremities Joint Moment and Joint Angle According to the Different Walking Speeds (보행 속도에 따른 하지 관절의 각도와 모멘트의 상관관계)

  • Shin, Seong-Hyoo;Lee, Hyo-Keun;Kwon, Moon-Seok
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.2
    • /
    • pp.75-83
    • /
    • 2008
  • The purpose of this study was to evaluate the correlation between joint moment and joint position angle according to the different walking speeds. According to the different walking speeds(1.5m/s, 1.8m/s, 2.1m/s), experiments were terminated by 8 male subjects. In conclusion, 1. The peak extensor moment of knee joint increased by increasing walking speed, however, walking speed didn't have an effect on peak flexor and abductor moment of knee joint. 2. The position angle of knee joint increased movement of flexion, but other position angles of knee joint didn't have difference when the peak extensor moment generated. 3. The peak joint moment of hip significantly increased in extension, flexion and abduction by increased walking speed. 4. The hip position angle showed more flexible at the hip peak flexor/extensor moment generated. 5. The co-ordination pattern between peak knee joint moment and knee position angle were mathematically modeled by using a least square method. We could get the high level value of R2. We expect to apply this results for evaluating the physical faculty of knee joint.

The Relationship Between Bone mineral Density and The Environmental Factors in Korean Pubescent Girls (한국 사춘기 소녀들의 골밀도와 환경요인들과의 관계(II))

  • 최미자
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.5 no.1
    • /
    • pp.41-51
    • /
    • 1995
  • Bone mass accretion during puberty appears to be critical in the development of peak bone mass. Although bone density of females in Korea has been studied, only a few studies have related bone mass with anthropometric patterns or puberty in the pubescent girls. This study was conducted as part of a study of major determinants of bone development during puberty. Subjects were aged 14∼16 yr(mean 14.97), and had no history of disorders or dedication use likely to influence bone or calcium metabolism. Bone mineral density and content were measured by dual energy X-ray absorptiometry using a Lunar DPX+Scanner (Lunar Madison, WI). Also, total body fat, and total lean body mass were assessed using a Lunar DPX dual-energy X-ray absorptiometer, Pubertal status was assessed according to the Marshall and Tanner guidelines. Serum levels of osteocalcin was measured by RIA using a commercial kit assay. Skinfold measurements were taken with a skinfold caliper(Lange Caliper, USA). Data were analyzed using the regression and GLM procedure of the statistical package SAS. The results indicated that the observed means for lumbar spine BMD and femoral BMD correspond to approximately 91% and 96% of the means for young adult females, respec tively. All subjects were menarchal, with the majority being in the middle to end stages of pubertal development. Total body BMD was positively related to fat mass(P<0.001), lean body mass and time since menarche, and negatively related to urine pyridinoline, serum alkaline phosphatase and osteocalcin. The data indicate that girls who reported lower age for menarche had significantly higher bone densities than girls who reported higher age for menarche. Attaining peak skeletal bone mass during puberty may reduce the incidence of osteoporosis in later life. this finding suggests that early menarche may augment peak bone mass, influencing the extent of bone loss later in adulthood. The results suggest that good nutrition in childhood appears to be needed not for growth and development, but possibly also to assure an optimal peak of bone mass and thus greater latitude for the maintenance or skeletal integrity in the face of bone losses. Troeps skinfold thickness was a better predictor of total BMD and total BMC than was any other skinfold thickness. The study did not find a relationship between total BMD and body fat %, but total fat was significantly positively related to total BMD(r=0.49) and total BMC(r=0.60). It supports earlier report that there was a significant correlation between TBMD and body weight. Conclusively, total fat, lean body mass and pubertal development could influence BMD in pubescent girls. Clearly, longitudinal studies are required to assess the effect of puberty on peak bone mass, and to define further the potential determinants of peak bone mass.

  • PDF

Development of PC Based Signal Postprocessing System in MR Spectroscopy: Normal Brain Spectrum in 1.5T MR Spectroscopy (PC를 이용한 자기공명분광 신호처리분석 시스템 개발: 1.5T MR Spectroscopy에서의 정상인 뇌 분광 신호)

  • 백문영;강원석;이현용;신운재;은충기
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.128-135
    • /
    • 2000
  • Purpose : The aim of this study is to develope the Magnetic Resonance Spectroscopy(MRS) data processing S/W which plays an important role as a diagnostic tool in clinical field. Materials and methods : Post-processing software of MRS based on graphical user interface(GUI) under windows operating system of personal computer(PC) was developed using MATLAB(Mathwork, U.S.A.). This tool contains many functions to increase the quality of spectrum data such as DC correction, zero filling, line broadening, Gauss-Lorentzian filtering, phase correction, etc. And we obtained the normal human brain $^1H$ MRS data from parietal white matter, basal ganglia and occipital grey matter region using 1.5T Gyroscan ACS-NT R6 (philips, Amsterdam, Netherland) MRS package. The analysis of the MRS peaks were performed by obtaining the ratio of peak area. Results : The peak ratios of NAA/Cr, Cho/Cr, MI/Cr for the different MRS machines have a little different values. But these peak ratios were not significantly different between different echo time MRS peak ratios in the same machine (p<0.05). Conclusion : MRS post-processing S/W based on GUI using PC was developed and applied to the analysis of normal human brain $^1H$ MRS. This independent MRS processing job increases the performance and throughput of patient scan of main console. Finally, we suggest that the database for normal in-yivo human MRS data should be obtained before clinical applications.

  • PDF

Nonlinear Conte-Zbilut-Federici (CZF) Method of Computing LF/HF Ratio: A More Reliable Index of Changes in Heart Rate Variability

  • Vernon Bond, Jr;Curry, Bryan H;Kumar, Krishna;Pemminati, Sudhakar;Gorantla, Vasavi R;Kadur, Kishan;Millis, Richard M
    • Journal of Pharmacopuncture
    • /
    • v.19 no.3
    • /
    • pp.207-212
    • /
    • 2016
  • Objectives: Acupuncture treatments are safe and effective for a wide variety of diseases involving autonomic dysregulation. Heart rate variability (HRV) is a noninvasive method for assessing sympathovagal balance. The low frequency/high frequency (LF/HF) spectral power ratio is an index of sympathovagal influence on heart rate and of cardiovascular health. This study tests the hypothesis that from rest to 30% to 50% of peak oxygen consumption, the nonlinear Conte-Zbilut-Federici (CZF) method of computing the LF/HF ratio is a more reliable index of changes in the HRV than linear methods are. Methods: The subjects of this study were 10 healthy young adults. Electrocardiogram RR intervals were measured during 6-minute periods of rest and aerobic exercise on a cycle ergometer at 30% and 50% of peak oxygen consumption ($VO_{2peak}$). Results: The frequency domain CZF computations of the LF/HF ratio and the time domain computations of the standard deviation of normal-to-normal intervals (SDNN) decreased sequentially from rest to 30% $VO_{2peak}$ (P < 0.001) to 50% $VO_{2peak}$ (P < 0.05). The SDNN and the CZF computations of the LF/HF ratio were positively correlated (Pearson's r = 0.75, P < 0.001). fast Fourier transform (FFT), autoregressive (AR) and Lomb periodogram computations of the LF/HF ratio increased only from rest to 50% $VO_{2peak}$. Conclusion: Computations of the LF/HF ratio by using the nonlinear CZF method appear to be more sensitive to changes in physical activity than computations of the LF/HF ratio by using linear methods. Future studies should determine whether the CZF computation of the LF/HF ratio improves evaluations of pharmacopuncture and other treatment modalities.

Analyzing Investment Effects of Fisheries R&D Projects : A Case of NFRDI's R&D Projects (수산업 R&D 사업의 투자효과 분석 : 국립수산과학원 수산시험연구사업을 중심으로)

  • Park, Kyoung-Il;Kim, Do-Hoon
    • The Journal of Fisheries Business Administration
    • /
    • v.44 no.2
    • /
    • pp.101-109
    • /
    • 2013
  • This study is aimed to analyze investment effects of fisheries R&D projects of the National Fisheries Research and Development Institute(NFRDI). In the analysis, Granger causal relations between R&D investment and fisheries production are tested. In addition, time-lag effects of fisheries R&D investment are estimated with an impulse response analysis and investment effects of R&D projects are estimated by changes of social surplus. Results indicate that there exists an Granger-causality between R&D investment and fisheries production and fisheries production responds to the fisheries R&D shock about three years after the initial shock. The magnitudes of the impacts increase until a peak is reached 5~7 years and the impacts decline to zero after 25 years. As investment effects, it is shown that the internal rate of returns of fisheries R&D investment is 55.2%.

An Evaluation of the Accuracy of Mini-Wright Peak Flow Meter (mini-Wright Peak Flow Meter에 의한 PEFR 측정의 정확도)

  • Koh, Young-Il;Choi, In-Seon;Na, Hyun-Ju;Park, Seok-Chae;Jang, An-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.298-308
    • /
    • 1997
  • Background : Portable devices for measuring peak expiratory flow(PEF) are now of proved value in the diagnosis and management of asthma and many lightweight PEF meters have become available. However, it is necessary to determine whether peak expiratory flow rate(PEFR) measurements measured with peak flowmeters is accurate and reproducible for clinical application. The aim of the present study is to define accuracy, agreement, and precision of mini-Wright peak flow meter(MPFM) against standard pneumotachygraph. Methods : The lung function tests by standard pneumotachygraph and PEFR measurement by MPFM were performed in a random order for 2 hours in 22 normal and 17 asthmatic subjects and also were performed for 3 successive days in 22 normals. Results : The PEFR measured with MPFM was significantly related to the PEFR and $FEV_1$ measured with standard pneumotachygraph in normal and asthmatics(for PEFR, r = 0.92 ; p < 0.001 ; for $FEV_1$, r = 0.78 ; p < 0.001). The accuracy of MPFM was within 100(limits of accuracy recommeded by NAEP) in all the subjects or 22 normal, mean difference from standard pneumotachygraph being 16.5L/min(percentage of difference being 2.90%) or 10.6L/min(percentage of difference being 1.75%), respectively. According to the method proposed by Bland and Altman, the 95% limits of the distribution of differences between MPFM and standard pneumotachygraph after correction of PEFR using our regression equation were +38.2 and -71.5L/min in all the subjects or 20.49~+9.49L/min in 22 normal and was similar to the intraindividual agreements for 3 successive days in normal. There was no statistically significant difference of PEFR measured with MPFM and standard pneumotachygraph among three days(p > 0.05) and the coefficient of variation($2.4{\pm}1.2%$) of PEFR measured with MPFM was significantly lower than that($5.2{\pm}3.5%$) with standard pneumotachygraph in normal (p < 0.05). Conclusion : This results suggest that the MPFM was as accurate and reproducible as standard pneumotachygraph for monitoring of PEFR in the asthmatic subjects.

  • PDF