• Title/Summary/Keyword: R&D Program

Search Result 1,343, Processing Time 0.027 seconds

A study on optimized Blanking size of Brace Center Pillar using Inverse module in PAM-STAMP (PAM-STAMP Inverse 모듈을 이용한 Brace Center Pillar Blanking 사이즈 최적화에 관한 연구)

  • You S.R.;Kim T.H.;Park J.D.;Kim M.J.;Chang S.G.;Jeon E.C.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.349-350
    • /
    • 2006
  • PAM-STAMP is a widely used program which deals with press forming analysis. A blanking used in the press process depends on the experience of the workers. Thus it causes some waste material and demands a lot of time and many costs at the manufacturing mold. So we need to optimize of the blanking size. We have studied the optimal blanking size of the Brace Center Pillar using an Inverse module in PAM-STAMP

  • PDF

PRESENT AND FUTURE OF SUPER HIGH-EFFICIENCY TANDEM SOLAR CELLS

  • Yamaguchi, Masafumi
    • Electrical & Electronic Materials
    • /
    • v.11 no.11
    • /
    • pp.37-45
    • /
    • 1998
  • In this paper, present status of super high-efficiency tandem solar cells has been reviewed and key issues for realizing super high-efficiency have also been discussed. In addition, the terretrial R&D activities of tandem cells, in the New Sunshine Program of MITI(Ministry of International Trade and Industry) and NEDO(New Energy and Industrial Technology Development Organization) in Japan are reviewed briefly. The mechanical stacked 3-junction cells of monolithically grown InGaP/GaAs 2-junction cells and InGaAs cells have reached the highest efficiency achieved in Japan of 33.3% at 1-sun AM1.5. This paper also reports high-efficiency InGaP/GaAs 2-junction solar cells with a world-record efficiency of 26.9% at AM0, 28$^{\circ}C$ and radiation damage recovery phenomena of the tandem cell performance due to minority-carrier injection under light illumination or forward bias, which causes defect annealing in InGaP top cells. Future prospects for realizing super-high efficiency and low-cost tandem solar cells are also described.

  • PDF

Ultimate strength of long-span buildings with P.E.B (Pre-Engineered Building) system

  • Lee, Seong-Hui;Kim, Young-Ho;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • v.19 no.6
    • /
    • pp.1483-1499
    • /
    • 2015
  • With the improvement of the quality of construction materials and the development of construction technologies, large-scale long-span steel frame buildings have been built recently. The P.E.B system using tapered members is being employed as an economically-efficient long-span structure owing to its advantage of being able to distribute stress appropriately depending on the size of sectional areas of members. However, in December 2005 and in February 2014, P.E.B buildings collapsed due to sudden loads such as snow loads and wind gusts. In this study, the design and construction of the P.E.B system in Korea were analyzed and its structural safety was evaluated using the finite element analysis program to suggest how to improve the P.E.B system in order to promote the efficient and rational application of the system.

Analysis of Transient Overvoltages within a 345kV Korean Thermal Plant

  • Yeo, Sang-Min;Kim, Chul-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.3
    • /
    • pp.297-303
    • /
    • 2012
  • This paper presents the simulation results for the analysis of a lightning surge, switching transients and very fast transients within a thermal plant. The modeling of gas insulated substations (GIS) makes use of electrical equivalent circuits that are composed of lumped elements and distributed parameter lines. The system model also includes some generators, transformers, and low voltage circuits such as 24V DC rectifiers and control circuits. This paper shows the simulation results, via EMTP (Electro-Magnetic Transients Program), for three overvoltage types, such as transient overvoltages, switching transients, very fast transients and a lightning surge.

Fire design of concrete encased columns: Validation of an advanced calculation model

  • Zaharia, R.;Dubina, D.
    • Steel and Composite Structures
    • /
    • v.17 no.6
    • /
    • pp.835-850
    • /
    • 2014
  • The fire resistance of composite steel and concrete structures may be determined by using the simplified methods provided in EN 1994-1-2. For the particular situations not covered by the standard, an advanced calculation model might be applied, using special purpose programs for the analysis of structures in fire. The validation of these programs has always been an important issue for software developers, but also for designers and authorities. Clause 4.4.4 from EN 1994-1-2 refers to the validation of the advanced calculation models and states that these models must be validated through relevant test results. The paper presents the calculation of fire resistance of the composite columns in a high-rise building built in Romania, and focusses on the validation of the calculation model (computer program SAFIR), for this particular case. This validation, asked by the Romanian authorities, considers the available experimental results of a fire test, performed on a similar composite steel-concrete column.

The benign prostate hypertrophy measurement simulator implementation and usefulness assessment through the sound analysis (요류음 분석을 위한 시뮬레이터의 구현)

  • Jeong D. U.;Shon J. M.;Jeon S. H.;Lee H. J.;Cho S. T.;Yong S. Y.;Choi B. C.;Jung M. K.;Jeon G. R.
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2005.05a
    • /
    • pp.154-159
    • /
    • 2005
  • In this paper, We used the microphone unlike existing urodynamic inspection which diagnoses the LUTS(lower urinary tract symptoms) and proposed sound measurement the method which the urination happens and apply at a blockade diagnosis. To analyze the blockade degree, We made the experiment set to modeling the Lower Urinry System of the human body and made the microphone of the stethoscope form for the measurement of the urinary sound which the urination happens. We used PC for the analysis of the urinary sound to be measured and implemented the analysis program to use the MATLAB. Hereafter, An analysis result usage, The Practical use will be possible as one of new inspection methods's.

  • PDF

Factors influencing the image about emergency medical technology jobs in paramedic students (응급구조(학)과 학생의 응급구조사 직업이미지에 미치는 영향 요인)

  • Hwang, Seong-Hak;Uhm, Dong-Choon
    • The Korean Journal of Emergency Medical Services
    • /
    • v.18 no.3
    • /
    • pp.63-75
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate the image about emergency medical technology (EMT) jobs and to identify factors influencing the image of EMT jobs among students of this department. Methods: A self-reported questionnaire was administered to 532 paramedic students in the cities of D, G, and J between May 28 and June 19, 2013. Data were analyzed by using the SPSS version 21.0 program. Results: The image about EMT jobs was positively related to self-esteem. However, the image about EMT jobs was negatively related to grade and hospital practice experience. In the multiple regression analysis, the adjusted $R^2$ value was .220 (p < .001). Conclusion: The importance of enhancing the self-esteem of paramedic students should be emphasized. Further research on the image about EMT jobs in the hospital practice setting is needed.

Design of Remote Control Systems using Super-Speed Ethernet and TCP/IP

  • Park, Joon-Hoon;Oh, Sea-Youn
    • Journal of information and communication convergence engineering
    • /
    • v.1 no.1
    • /
    • pp.6-11
    • /
    • 2003
  • In general, standard TCP/IP (transmission control protocol-internet protocol), which is called TCP/IP, is using as the communication basis protocol between any collections of networks that is connected. In this paper, using this TCP/IP implementation of remote control system and suitable program for long distance communication is proposed. This system can make system, which basic Ethernet and TCP/IP used system, to mini modeling, so all module that is using here can be used. Therefore, intention of this paper is to reduce expenses, to effective manage for plant and to increase of productivity as linking each plant of several factory to TCP/IP and Ethernet, and then many control plant and manager minimize the needed course.

Review of Social Manufacturing Technology on Product Life Cycle Management(PLM) Base (제품수명주기관리(PLM) 기반의 소셜매뉴팩처링 기술 고찰)

  • Park, Jong-Man;Kim, Bong-Sun
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.39 no.3
    • /
    • pp.156-162
    • /
    • 2013
  • Social manufacturing architecture is based on information delivery through social media and SNS, PLM and social platform, crowd source and knowledge base on whole phase of product life cycle. Although advanced social manufacturing issues are rising globally, its technology emerging into domestic industry is likely to be slow. We focused to review technological changes and R&D trend, patent issues, and then suggest assignments and advices to be practiced for social manufacturing modeling.