• 제목/요약/키워드: Quasi steady state

검색결과 158건 처리시간 0.028초

Enzyme Kinetics of Multiple Inhibition in the Presence of Two Reversible Inhibitors

  • Han, Moon H.;Seong, Baik L.
    • Bulletin of the Korean Chemical Society
    • /
    • 제3권3호
    • /
    • pp.122-129
    • /
    • 1982
  • In order to extend our understanding on the multiple inhibition enzyme kinetics, a general equation of an enzyme reaction in the presence of two different reversible inhibitors was derived by what we call "match-box mechanism" under the combined assumption of steady-state and quasi-equilibrium for inhibitor binding. Graphical methods were proposed to analyze the multiple inhibition of an enzyme by any given sets of different inhibitors, i.e., competitive, noncompetitive, and uncompetitive inhibitors. This method not only gives an interaction factor $({\alpha})$ between two inhibitors, but also discerns ${\alpha}_1$ and ${\alpha}_2$ with and without substrate binding, respectively. The factors involved in the dissociation constants of inhibitors can also be evaluated by the present plot. It is also shown that the present kinetic approach can be extended to other forms of activators or hydrogen ions with some modification.

보조스위치가 동기정류기 구동 신호로 제어되는 능동 클램프형 플라이백 컨버터의 스위칭 특성에 관한 연구 (A Study on Switching Characteristics of Active Clamp Type Flyback Converter with Synchronous Rectifier Driving Signals Controlling Auxiliary Switch)

  • 안태영
    • 반도체디스플레이기술학회지
    • /
    • 제17권3호
    • /
    • pp.21-26
    • /
    • 2018
  • In this paper, the switching characteristics of the active clamp type flyback converter, which is deemed suitable for the miniaturization of the external power supply for home appliance, were analyzed and the process of reducing the switching loss was explained. The active clamp type flyback converter operating in the DCM has confirmed that the surge voltage of the main switch does not occur and the turn-off / on loss of the switch do not occur in principle. Also, in the case of the switch for synchronous rectifier, it was showed that the switch current showed half-wave rectified sinusoidal characteristic, and the switching loss was reduced. The switching characteristics of the experimental results gathered from 120 W class prototype were compared with the theoretical waveform in the steady-state and it was confirmed that the power conversion efficiency of the active clamp type flyback converter was maintained high due to the reduction of the switching loss.

Effect of rain on flutter derivatives of bridge decks

  • Gu, Ming;Xu, Shu-Zhuang
    • Wind and Structures
    • /
    • 제11권3호
    • /
    • pp.209-220
    • /
    • 2008
  • Flutter derivatives provide the basis of predicting the critical wind speed in flutter and buffeting analysis of long-span cable-supported bridges. Many studies have been performed on the methods and applications of identification of flutter derivatives of bridge decks under wind action. In fact, strong wind, especially typhoon, is always accompanied by heavy rain. Then, what is the effect of rain on flutter derivatives and flutter critical wind speed of bridges? Unfortunately, there have been no studies on this subject. This paper makes an initial study on this problem. Covariance-driven Stochastic Subspace Identification (SSI in short) which is capable of estimating the flutter derivatives of bridge decks from their steady random responses is presented first. An experimental set-up is specially designed and manufactured to produce the conditions of rain and wind. Wind tunnel tests of a quasi-streamlined thin plate model are conducted under conditions of only wind action and simultaneous wind-rain action, respectively. The flutter derivatives are then extracted by the SSI method, and comparisons are made between the flutter derivatives under the two different conditions. The comparison results tentatively indicate that rain has non-trivial effects on flutter derivatives, especially on and $H_2$ and $A_2$thus the flutter critical wind speeds of bridges.

월류 시 마운드형태 방조제에 작용하는 압력과 유속 산정 (Estimation of Overflow-Induced Pressure and Velocity on a Mound-Type Sea Dike)

  • 김태형;;김성웅;최명호
    • 한국지반환경공학회 논문집
    • /
    • 제16권3호
    • /
    • pp.5-13
    • /
    • 2015
  • 해일에 의한 바닷물의 월류는 방조제 구조물에 피해를 유발시킨다. 지금까지 발생된 마운드 형태 방조제의 파괴 유형 조사 결과, 육지 쪽 마루부 파손과 선단부의 세굴이 대표적인 파괴 사례로 지목되었다. 이와 같은 파괴를 유발하는 가장 큰 원인은 월류에 의해 발생된 압력과 유속이다. 본 연구에서는 에너지 관점에서 마운드 형태 방조제에서 압력과 유속을 산정할 수 있는 이론해를 제안하고 검증하였다. 이를 위해 방조제 마루부와 선단부에 흐름을 유사정적비회전류로 보고 동심원유선이 형성된다고 가정하였다. 한계흐름조건과 베르누이정리를 이용하여 방조제 마루부와 배면 선단부에서의 작용하는 압력 및 유속 산정식을 유도하였다. 이들 식을 이용하여 동심원유선 및 월류고를 가정하여 마루부와 선단부에서 압력과 유속을 산정하였다. 그 결과 마루부에서는 부의 압력이 선단부에서는 양의 압력이 각각 크게 작용하는 것으로 나타났으며 유속에 의한 전단응력도 작용하는 것을 확인하였다. 또한 제안된 이론해의 적용 한계에 대한 고찰도 이루어졌다.

FDS의 격자 종횡비에 관한 연구 (A study on grid aspect ratio of fire dynamics simulator)

  • 김원욱;박외철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권9호
    • /
    • pp.923-928
    • /
    • 2015
  • FDS는 화재분석에 가장 많이 사용되는 프로그램 중 하나로 정확한 분석을 위하여 적정격자 선정이 필요하다. 이 연구에서는 적정격자 선정을 위하여 다양한 격자 종횡비(AR)를 선정하여 FDS v 6.1.2로 분석하였다. 계산시간은 온도 등의 변화로부터 시간평균값을 구하는데 충분히 긴 10분으로 설정하였다. 그리고 온도와 가시거리, 질량수지의 시간평균값은 준정상상태를 유지하는 200~600초 구간의 값으로부터 구하였다. 그 결과 $10{\times}10{\times}3[m^3]$$20{\times}20{\times}3[m^3]$의 두 공간에 각각 1 [MW]와 2 [MW]의 폴리우레탄 화재가 발생했을 때 종횡비 1~6에 대한 열방출률과 온도, 가시거리, 질량수지를 비교하였다. 열방출률은 종횡비와 공간의 크기 및 화재규모에 무관하게 정확함을 확인하였다. 또 $AR{\leq}5$에서는 준정상상태의 온도와 가시거리가 잘 예측되었다. 그러나 종횡비의 증가에 따라 온도의 감소폭이 증가하였고, 질량보존의 만족도가 떨어졌다. 따라서 화재 초기의 온도와 가시거리가 중요한 요소인 성능위주설계에서 $AR{\geq}3$인 경우에는 격자크기에 대한 세심한 검토가 필요함을 확인하였다. 높은 정확도가 요구되는 구획화재 시뮬레이션에는 수직방향 격자크기 0.1~0.2 [m] 이하와 종횡비 2 이하의 격자크기가 바람직함을 알 수 있었다.

Modeling of coupled liquid-gas-solid three-phase processes due to fluid injection

  • Zang, Yong-Ge;Sun, Dong-Mei;Feng, Ping;Stephan, Semprich
    • Geomechanics and Engineering
    • /
    • 제13권1호
    • /
    • pp.1-23
    • /
    • 2017
  • A coupled liquid-gas-solid three-phase model, linking two numerical codes (TOUGH2/EOS3 and $FLAC^{3D}$), was firstly established and validated by simulating an in-situ air flow test in Essen. Then the coupled model was employed to investigate responses of multiphase flow and soil skeleton deformation to compressed air or freshwater injection using the same simulation conditions in an aquifer of Tianjin, China. The simulation results show that with injecting pressurized fluids, the vertical effective stress in some area decreases owing to the pore pressure increasing, an expansion of soil skeleton appears, and land uplift occurs due to support actions from lower deformed soils. After fluids injection stops, soil deformation decreases overall due to injecting fluids dissipating. With the same applied pressure, changes in multiphase flow and geo-mechanical deformation caused by compressed air injection are relatively greater than those by freshwater injection. Furthermore, the expansion of soil skeleton induced by compressed air injection transfers upward and laterally continuously with time, while during and after freshwater injection, this expansion reaches rapidly a quasi-steady state. These differences induced by two fluids injection are mainly because air could spread upward and laterally easily for its lower density and phase state transition appears for compressed air injection.

복사 열손실을 받는 대향류 확산화염의 불안정성 해석 (Instability Analysis of Counterflow Diffusion Flames with Radiation Heat Loss)

  • 이수룡
    • 대한기계학회논문집B
    • /
    • 제36권8호
    • /
    • pp.857-864
    • /
    • 2012
  • 복사열손실을 받는 확산화염의 선형 안정성 해석을 수행하여 복사강도와 Damkohler 수에 대한 화염 불안정이 나타나는 조건을 확인하였다. 대향류 유동장을 모델로 하여 Lewis 수는 1로 가정하였다. 반응속도 제한에 의한 소염근처에서 교란의 증가율은 실수의 고유값을 가지며 안정한계는 정상상태 소염조건과 정확하게 일치한다. 반면에 복사 열손실에 의한 소염 영역 근처에서 증가율의 고유값은 복소수이며 정상상태 소염 전에 맥동 불안정성이 예측된다. 진동하는 화염온도가 양의 실수 고유값을 갖는 정상상태 화염온도 보다 클 경우에만 한계 순환 안정 특성이 나타난다. 만약 그 온도보다 작게 되면 화염은 회복되지 못하고 소염된다. 넓은 복사강도 범위에 대하여 복사 열손실에 의한 불안정성의 안정한계 곡선을 도시하였다.

수소 희석비에 따른 실리콘 이종접합 계면에 대한 분석 및 태양전지로의 응용 (Effect of Hydrogen Dilution Ratio on The Si Hetero-junction Interface and Its Application to Solar Cells)

  • 박준형;명승엽;이가원
    • 한국전기전자재료학회논문지
    • /
    • 제25권12호
    • /
    • pp.1009-1014
    • /
    • 2012
  • Hydrogenated amorphous silicon (${\alpha}$-Si:H) layers deposited by plasma enhanced chemical vapor deposition (PECVD) are investigated for use in silicon hetero-junction solar cells employing n-type crystalline silicon (c-Si) substrates. The optical and structural properties of silicon hetero-junction devices have been characterized using spectroscopy ellipsometry and high resolution cross-sectional transmission electron micrograph (HRTEM). In addition, the effective carrier lifetime is measured by the quasi-steady-state photocoductance (QSSPC) method. We have studied on the correlation between the order of ${\alpha}$-Si:H and the passivation quality at the interface of ${\alpha}$-Si:H/c-Si. Base on the result, we have fabricated a silicon hetero-junction solar cell incorporating the ${\alpha}$-Si:H passivation layer with on open circuit voltage ($V_{oc}$) of 637 mV.

결정방향에 따른 결정질 실리콘 태양전지 후면전계 특성 연구 (Study of back surface field for orientation on Crystalline Silicon solar cell)

  • 김현호;박성은;김영도;송주용;탁성주;박효민;김성탁;김동환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.41.2-41.2
    • /
    • 2010
  • 최근 태양전지 제조비용 절감을 위해 초박형 실리콘 태양전지 개발이 활발히 이루어지고 있다. 이에 따라 후면전계(Back Surface Field, BSF) 특성에 대한 관심이 높아지는 추세이다. 이에 본 연구에서는 후면의 결정방향 및 표면구조에 따라 형성되는 후면전계(BSF)의 특성에 대해 알아보고자 하였다. 후면이 절삭손상층 식각(Saw damage etching) 후 (100)면이 드러난 실리콘 기판과 텍스쳐링(Texturing) 후 (111)면이 드러난 실리콘 기판에 후면 전극을 스크린 인쇄 후 Ramp up rate을 달리 하여 소성 공정(RTP system)을 통해 후면전계(BSF)를 형성하여 비교하였다. 후면전계(BSF)의 형상과 특성만을 평가하기 위하여 염산을 이용하여 후면 전극층을 제거하였다. 후면 전극 제거 후 주사전자현미경(Scanning Electron Microscopy)과 3차원 미세형상측정기(Non-contacting optical profiler)로 후면전계(BSF)의 형상을 비교하였다. 또한 후면전계(BSF)의 특성을 평가하고자 Quasi-Steady-State Photo Conductance(QSSPC)를 사용하여 포화전류(Saturation current, $J_0$)을 측정하였고, 면저항 측정기(4-point probe)로 면저항을 측정하여 비교하였다. 후면 전계(BSF)는 (100)면과 (111)면에서 모두 Ramp up rate이 빠를수록 향상된 특성을 보였고, (111)면에서 더 큰 차이를 보였다.

  • PDF

Passivation Properties of Hydrogenated Silicon Nitrides deposited by PECVD

  • Kim, Jae Eun;Lee, Kyung Dong;Kang, Yoonmook;Lee, Hae-Seok;kim, Donghwan
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.334.2-334.2
    • /
    • 2016
  • Silicon nitride (SiNx:H) films are generally used as passivation layer on solar cell and they are usually made by plasma enhanced chemical vapor deposition (PECVD). In this study, we investigated the properties of silicon nitride (SiNx:H) films made by PECVD. Effects of mixture ratio of process gases with silane (SiH4) and ammonia (NH3) on the passivation qualities of silicon nitride film are evaluated. Passivation properties of SiNx:H are focused by making antireflection properties identical with thickness and refractive index controlled. The absorption coefficient of each film was evaluated by spectrometric ellipsometery and the minority carrier lifetimes were evaluated by quasi-steady-state photo-conductance (QSSPC) measurement. The optical properties were obtained by UV-visible spectrophotometer. The interface properties were measured by capacitance-voltage (C-V) measurement and the film components were identified by Fourier transform infrared spectroscopy (FT-IR) and Rutherford backscattering spectroscopy detection (RBS) - elastic recoil detection (ERD).

  • PDF