• 제목/요약/키워드: Quality factor(Q)

검색결과 462건 처리시간 0.025초

단일동조 수동고조파필터 설계시의 동조계수(δ) 및 양호도(Q)값 연구 (A Study on Tuning Factor(δ) and Quality Factor(Q) Values in Design of Single-Tuned Passive Harmonic Filters)

  • 조영식;차한주
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.64-70
    • /
    • 2010
  • This paper presents how to decide on tuning factor(${\delta}$) and quality factor(Q) values in design of single-tuned passive harmonic filters. Tuning factor(${\delta}$) and quality factor(Q) values have to consider before decision on circuit parameters of passive filters. A Study on these two value has not been scarcely performed and only experienced values has been used in passive harmonic filter design by far. As a experienced value, in cases of 5th and 7th filter, tuning factor(${\delta}$) is about 0.94 and 0.96 respectively and quality factor(Q) is, in all cases of, 50. If Single-tuned passive harmonic filter will be off-tuned, performance of filter will be decreased steeply and occur to parallel resonance between system reactance and filter capacitance. Therefore During the operation, In order not to off-tuning, Filter must be tuned at former order than actual tuning order. This is the same that total impedance of filter must have a reactive impedance. In this paper, Tuning factor(${\delta}$) is decided via example of real system and using the bode-plot and then performance of filters confirmed by filter current absorbtion rate. And Quality factor(Q) decided using the bode plot in example system and then performance of filters confirmed by filter current absorbtion rate also, which makes a calculated filter parameters to satisfy IEEE-519 distortion limits. Finally, Performance of the designed passive harmonic filter using the tuning factor(${\delta}$) and quality factor(Q) values, decided in this paper is verified by experiment and shows that 5th, 7th, 9th, 11th and 13th current harmonic distortions are decreased within IEEE-519 distortion limits, respectively.

고객지향적 병원 급식서비스 운영을 위한 질 평가 도구 개발 및 적용 (Development of Quality Assessment Tool and Application to Customer-Oriented Hospital Foodservice Management)

  • 이해영;장승희;양일선
    • Journal of Nutrition and Health
    • /
    • 제37권4호
    • /
    • pp.329-338
    • /
    • 2004
  • The purposes of this study were to : a) develop the quality assessment tool of hospital foodservice management, b) evaluate the S hospital's foodservice quality by this tool, and c) do the feasibility study about this tool in hospital food-service field by establishing quality management strategies. The developed quality assessment tool of hospital food-service management was consisted of 20 items for quality evaluation by Likert 5 point scale and two additional questions with the most satisfactory item and the most unsatisfactory item. As a result of evaluation, S hospital's foodservice quality was somewhat high, on the factor 'personnel attitude', especially. The IPA technique proved nine items including Q5, Q7, Q8, Q11, Q12, Q13, Q15, Q16, Q17 were in 'Doing Great, Keep It Up' and seven items such as Q1, Q2, Q3, Q6, Q9, Q18, Q19 that got high expectation and low perception needed to be focused in quality management strategy.

유연한 Quality factor가 가능한 단순한 광섬유 팁 공진 구조물 (Simple fiber tip assembly with flexible Quality factor)

  • 나경필;권오대
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2002년도 제13회 정기총회 및 2002년도 동계학술발표회
    • /
    • pp.260-261
    • /
    • 2002
  • For Near-field Scanning Optical Microscopy measurements, the fiber tip is glued on the side of one of the tuning fork prongs vertically to its extended direction. Higher Q-factor is attainable in this geometry than in the arrangement with the fiber tip parallel to the prong. A simple mechanical design is applied to hold the fiber tip above the gluing point. The overall tuning fork-fiber tip assembly gives another advantage of the flexible Q-factor enhancement. With this treatment, Q-factor higher than 3000 is easily achievable. As an operating instance, a grating is scanned for its one dimensional topographical image.

  • PDF

높은 Q값을 갖는 저전압 능동 CMOS 인덕터 (A Low-voltage Active CMOS Inductor with High Quality Factor)

  • 유태근;홍석용;정항근
    • 대한전자공학회논문지SD
    • /
    • 제45권2호
    • /
    • pp.125-129
    • /
    • 2008
  • 본 논문에서는 Q값(Q-factor)을 증가시킬 수 있는 저전압 능동(active) CMOS 인덕터를 제안하고 설계하였다. Q값을 증가시키기 위한 방법으로 저전압 능동 CMOS 인덕터에 피드백 저항을 삽입하여 등가적인 인덕턴스와 Q값을 증가시켰다. 저전압 능동 CMOS 인덕터는 0.18um 표준 CMOS 공정으로 설계하였으며 모의실험은 애질런트사의 ADS 시뮬레이터를 이용하였다. 모의 실험결과 설계된 피드백 저항을 삽입한 저전압 능동 CMOS 인덕터는 4GHz에서 1.5nH의 인덕턴스와 최대 3000이상의 Q값을 가졌고 소비전력은 5.4mW였다.

캐비티 재질이 마이크로파 유전체 공진기의 Q값 측정에 미치는 영향 (Effect of Cavity Material on the Q-Factor Measurement of Microwave Dielectric Materials)

  • 박재환;박재관
    • 마이크로전자및패키징학회지
    • /
    • 제18권3호
    • /
    • pp.39-43
    • /
    • 2011
  • 마이크로파 유전체의 Q 값 측정에 널리 사용되고 있는 유전체 공진기 방법에서 캐비티의 재질변화가 유전체의 Q 값 측정에 미치는 오차요인에 대해 HFSS 시뮬레이션과 실측평가를 병행하여 조사하였다. HFSS의 전자계 벡터 형상으로부터 $TE_{01\delta}$ 모드의 공진주파수를 결정하고 $S_{21}$ 파라메터의 3dB 대역폭으로부터 Q 값을 계산하였다. 캐비티 금속이 Cu, SUS, Au 등으로 변화할 경우 유전체 공진기의 Q 값 측정에 큰 오차는 발생하지 않았으나, 금속이 산화하여 전도도가 수 천 정도로 떨어질 경우 Q 값이 매우 낮게 측정되는 오차가 발생함을 확인하였다. 이러한 시뮬레이션 결과는 실제로 다양한 재질의 금속 캐비티를 가지고 유전체 공진기의 Q 값을 측정해 본 결과 서로 일치되는 관련성을 나타내었다.

실리콘 기판에서 다층 메탈을 이용한 CMOS 나선형 인덕터의 Q향상에 관한 연구 (Study on Q Improvement of CMOS Spiral Inductor Using Multi Metal Layer for Silicon Substrate)

  • 손주호;최석우;김동용
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권1호
    • /
    • pp.6-11
    • /
    • 2003
  • The multi layer spiral inductors, which enhance the quality factor Q of an inductor fabricated on the silicon substrate, has been designed using a TSMC CMOS 0.2sum 1-poly 5-metal layer technology. To investigate the performance of the designed inductors, a 2.5-dimensional field simulation tool(Momentum) is used. The simulation results show that the quality factor Q of the 5-metal inductor is improved 1.8 times over that of a convention31 spiral inductor at 2GHz for wireless LAN applications.

Pb(La,Ce)$TiO_3$계 세라믹스의 길이와 두께비($\ell$/t)에 따른 공진특성 (Resonant Characteristics as the Variations of $\ell$/t(length/thicknes) Ratio of Pb(La,Ce)$TiO_3$ System Ceramics)

  • 민석규;오동언;윤광희;류주현;박창엽;김종선
    • 한국전기전자재료학회논문지
    • /
    • 제14권9호
    • /
    • pp.720-725
    • /
    • 2001
  • In this study, Pb(La,Ce)Ti $O_3$ ceramics were manufactured for 20 MHz resonator application. Electromechanical coupling factor( $k_{t}$, $k_{t3}$, mechanical quality factor( $Q_{mt}$ , $Q_{mt3}$ and dydnamic range (D.R) of thickness vibration mode were measured as the variations of $\ell$/t(length/thickness) ratio of ceramic substrates. Mechanical quality factor( $Q_{mt3}$) and dynamic range of third overtone thickness vibration mode showed the highest value of 2,773 and 52.22dB at specimen S4($\ell$/t=12), respectively. The excellent temperature stability of resonant frequency suitable for resonator application was shown, regardless of thermal shock.k.ock.k.

  • PDF

JPEG 재압축이 컬러 이미지 품질에 미치는 영향에 관한 연구 (A study on the effect of JPEG recompression with the color image quality)

  • 이성형;조가람;구철희
    • 한국인쇄학회지
    • /
    • 제18권2호
    • /
    • pp.55-68
    • /
    • 2000
  • Joint photographic experts group (JPEG) is a standard still-image compression technique, established by the international organization for standardization (ISO) and international telecommunication standardization sector (ITUT). The standard is intended to be utilized in the various kinds of color still imaging systems as a standard color image coding format. Because JPEG is a lossy compression, the decompressed image pixel values are not the same as the value before compression. Various distortions of JPEG compression and JPEG recompression has been reported in various papers. The Image compressed by JPEG is often recompressed by same type compression method in JPEG. In general, JPEG is a lossy compression and the quality of compressed image is predicted that is varied in according to recompression Q-factor. In this paper, four difference color samples(photo image, gradient image, gradient image, vector drawing image, text image) were compressed in according to various Q-factor, and then the compressed images were recompressed according to various Q-factor once again. As the result, this paper evaluate the variation of image quality and file size in JPEG recompression and recommed the optimum recompression factor.

  • PDF

JPEG 재 압축이 컬러 이미지 품질에 미치는 영향에 관한 연구 (A Study on the effect of JPEG recompression with the color image quality)

  • 이성형;구철회
    • 한국인쇄학회:학술대회논문집
    • /
    • 한국인쇄학회 2000년도 춘계 학술발표회 논문집
    • /
    • pp.17-24
    • /
    • 2000
  • The Joint Photographic Experts Group (JPEG) is a standara still-image compression technique, established by the International for Standardization (ISO) and International Telecommunication Standardization Sector (ITUT). The standard is intended to be utilized in the various kinds of color still imaging systems as a standard color image coding format. Because JPEG is a lossy compression, the decompressed image pixel values are nto the same as values before compression. Image of JPEG compression is often made to JPEG recompression at saving to apply JPEG compression of color image. In general, JPEG is a lossy compression and compression image is predicted to be varied image quality according to recompressed Q-factor. Various distortions of JPEG compression and JPEG recompression has been reported in previous paper. In this paper, we compress four difference color samples (photo image, gradient image, vector drawing image, text image) according to various Q-factor, and then compressed images are recompressed according to various Q-factor once again. As the results, we inspect variation of quality and file size of recompressed color image, and ensure the optimum recompression factor.

Quality of Life Index-Caner의 구성타당도 검증 -국내 암환자를 대상으로- (Validation of Quality of Life Index-Cancer among Korean Patients with Cancer)

  • 소향숙;이원희;이은현;정복례;허혜경;강은실
    • 대한간호학회지
    • /
    • 제34권5호
    • /
    • pp.693-701
    • /
    • 2004
  • Purpose: The purpose of this study was to validate Quality of Life Index-Cancer (Q.L.I.-C) developed by Ferrans (1990) among Korean cancer patients. Method: This study design was exploratory factor analysis methodology. Q.L.I.-C was translated into Korean and reverse-translated into English. The subjects were 357 Korean patients with various cancers. Data were collected by questionnaires from May to August, 2000 and was analyzed by descriptive statistics, Principal Component Analysis for construct validity and Cronbach's alpha coefficient for reliability. Result: The range of factor loadings was .446~.841. The explained variance from the 5 extracted factors was 63.7% of the total variance. The first factor 'family' was 35.5%, and 'health & physical functioning', 'psychological', 'spiritual', and 'economic' factors were 11.5%, 6.9%, 5.6%, and 4.2% respectively. Because of cultural difference between Americans and Koreans, certain items such as sexuality, job status, and education were deleted from the extraction of factors in this study. The Cronbach's alpha coefficient was .9253 among the 28 items. Conclusion: Q.L.I.-C could be applied in measuring quality of life of Korean cancer patients. It also recommend to do further studiesfor validation of Q.L.I.-C American and Korean versions relating to cultural differences.