• Title/Summary/Keyword: Quality control device

Search Result 434, Processing Time 0.023 seconds

The Study on the Medical and Nursing Service Needs of the Terminal Cancer Patients and Their Caregivers (말기암 환자와 가족의 의료 및 간호 서비스 요구)

  • 이소우;이은옥;허대석;노국희;김현숙;김선례;김성자;김정희;이경옥
    • Journal of Korean Academy of Nursing
    • /
    • v.28 no.4
    • /
    • pp.958-969
    • /
    • 1998
  • In this study, we attempted to investigate the needs and problems of the terminal cancer patients and their family caregivers to provide them with nursing information to improve their quality of life and prepare for a peaceful death. Data was collected from August 1, 1995 to July 31, 1996 at the internal medicine unit of S hospital in Seoul area with the two groups of participants who were family members of terminal cancer patients seventy four of them were in-patients and 34 were out-patients who were discharged from the same hospital for home care. The research tool used in this study has been developed by selecting the questionnaires from various references, modifying them for our purpose and refining them based on the results of preliminary study. While general background information about the patients was obtained by reviewing their medical records, all other information was collected by interviewing the primary family caregivers of the patients using the questionnaire. The data collected were analyzed with the SPSS PC/sup +/ program. The results of this study are summarized as follows ; 1) Most frequently complained symptoms of the terminal cancer patients were in the order of pain(87%), weakness(86.1%), anorexia(83.3%) and fatigue (80.6%). 2) Main therapies for the terminal cancer patients were pain control (58.3%), hyperalimentation(47.2%) and antibiotics(21.3%). 3) Special medical devices that terminal cancer patients used most were oxygen device (11.1%), and feeding tube(5.6%). Other devices were used by less than 5% of the patients. 4) The mobility of 70.4% of the patients was worse than ECOG 3 level, they had to stay in bed more than 50% of a day. 5) Patients wanted their medical staffs to help relieve pain(45.4%), various physical symptoms(29.6%), and problems associated with their emotion(11.1%). 6) 16.7% of the family caregivers hoped for full recovery of the patients, refusing to admit the status of the patients. Also, 37% wished for the extension of the patient's life at least for 6 months. 7) Only 38.9% of the family members was preparing for the patient's funeral. 8) 45.4% of family caregivers prefer hospital as the place for the patient's death, 39.8% their own home, and 14.8% undetermined. 9) Caregivers of the patients were mostly close family members, i.e., spouse(62%), and sons and daughters or daughter-in-laws(21.3%). 10) 43.5% of the family caregivers were aware of hospice care. 46.8% of them learned about the hospice care from the mass media, 27.7% from health professionals, and the rest from books and other sources. 11) Caregivers were asked about the most difficult problems they encounter in home care, 41 of them pointed out the lack of health professionals they can contact, counsel and get help from in case of emergency, 17 identified the difficulty of finding appropriate transportation to hospital, and 13 stated the difficulty of admission in hospital as needed. 12) 93.6% of family caregivers demanded 24-hour hot line, 80% the visiting nurses and doctors, and 69.4% the volunteer's help. The above results indicate that terminal patients and their family caregivers demand help from qualified health professionals whenever necessary. Hospice care system led by well-trained medical and nursing staffs is one of the viable answers for such demands.

  • PDF

Evaluation of Temperature and Humidity of a Thermo-Hygrostat of PET/CT Equipment using a Temperature and Humidity Sensor(BME 280) (온·습도센서(BME 280 센서)를 이용한 PET/CT 장비의 항온 항습기 온·습도 평가)

  • Ryu, Chan-Ju;Kim, Jeong-A;Kim, Jun-Su;Yun, Geun-Yeong;Heo, Seung-Hui;Hong, Seong-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • PET(Positron Emission Tomography) devices are used as PET/CT or PET/MRI devices fused with the devices of CT or MRI for obtaining anatomical information. Therefore, the devices are constructed in circular ring-type structure whose length of gantry(the main part of filming) becomes wider and the interior depth becomes longer in comparison to other common medical equipments. scintillator, one of the components in PET devices, is inside the gantry, and as it is consisted of crystal which is sensitive to the change of temperature and humidity, large temperature change can cause the scintillator to be damaged. Though scintillator located inside the gantry maintains temperature and humidity with a thermo-hygrostat, changes in temperature and humidity are expected due to structural reasons. The output value was measured by dividing the inside of the gantry of the PET/CT device into six zones, each of which an Adafruit BME 280 temperature and humidity sensor was placed at. A thermo-hygrostat keeps the temperature and humidity constant in the PET/CT room. As the measured value of temperature and humidity of the sensor was obtained, the measured value of temperature and humidity appeared in the thermohygrostat was taken at the same time. Comparing the average measured values of temperature and humidity measured at each six zones with the average values of the thermo-hygrostat results in a difference of 2.71℃ in temperature and 21.5% in humidity. The measured temperature and humidity of PET Gantry is out of domestic quality control range. According to the results of the study, if there is continuous change in temperature and humidity in the future, the aging of the scintillator mounted in the PET Gantry is expected to be aging, so it is necessary to find a way to properly maintain the temperature and humidity inside the Gantry structure.

Study on Hay Preparation Technology for Alfalfa Using Stationary Far-Infrared Dryer (정치식 원적외선 건조기를 이용한 알팔파 건초 조제 기술 연구)

  • Kim, Jong Geun;Kim, Hyun Rae;Jeong, Eun Chan;Ahmadi, Farhad;Chang, Tae Kyoon
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.42 no.2
    • /
    • pp.73-78
    • /
    • 2022
  • This experiment was conducted to establish the technology for artificial hay preparation in Korea. Using far-infrared heater, a device that can control temperature, airflow, and far-infrared radiation was produced and conducted on the fourth harvested alfalfa. The drying conditions were carried out by selecting a total of four conditions. For each condition, the radiation rate was set to around 40% (33-42%), and the temperature was set at 58~65℃, and the speed of the airflow was fixed at 60m/s. The overall drying time was set to 30 min in the single and 60 min (30-30 min) and 90 min (30-30-30 min) in the complex condition, and the radiation rate and temperature were changed by time period. In the case of drying condition 1, the final dry matter (DM) content was 46.26%, which did not reach a DM suitable for hay. However, all of the alfalfa corresponding to the remaining drying conditions 2 to 7 showed a DM content of 80% or more, resulting in optimal alfalfa hay production. In power consumption according to the drying conditions, the second drying condition showed the lowest at 4.7 KW, and the remaining drying conditions were as high as 6.5 to 7.1 KW. The crude protein content was found to be high at an average of 25.91% and it showed the highest content in the 5th drying condition (26.93%) and the lowest value in the 6th drying condition (25.16%). The digestibility showed a high value with an average of 84.90%, and there was no significant difference among treatments (p>0.05). Considering the above results, it was judged that drying condition 2 was the most advantageous.

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF