• Title/Summary/Keyword: Quality Maintenance

Search Result 1,842, Processing Time 0.057 seconds

The Evaluation of River Naturalness Improvement Using AHP (계층분석과정기법(AHP)을 이용한 하천자연도평가법 개선)

  • Cho, Hong-Je;Yoon, Jong-Chun
    • Journal of Wetlands Research
    • /
    • v.11 no.3
    • /
    • pp.21-35
    • /
    • 2009
  • To propose a sound direction for river rehabilitation plan, the naturalness of the river must be evaluated. In this study, the conventional methods for evaluating the naturalness of rivers proposed by Park, et al. has been improved to estimate the weights for each items subject to assessment and applied adequate Analytic Hierarchy Process (AHP). To estimate the weights, survey was conducted on a group of 83 experts in Civil and Environmental Engineering with a customized questionnaire. The results of the survey were generalized and used to estimate the weights of each items. Among the 14 evaluation items that have been generated as a result of the estimation, a total of 7 weight values such as water quality, variations in water flow, vegetation around minor bed, curve of waterway, vegetation around flood plain, variety in minor bed width, and diversity of stream bed materials appeared to be high. The improved method for evaluating the naturalness of rivers was applied to Hoe-ya River, where the method has successfully discriminated the sections having low degree of naturalness. The proposed assessment method can be employed as a criterion to determine the business zones in the river environment maintenance projects.

  • PDF

Comparison of Continuing Education Program for Emergency Medical Technician in Korea and Abroad (국내·외 응급구조사의 보수교육프로그램 비교조사)

  • Shin, Dong-Min;Jang, Mun-Sun;Kang, Bo-Ra;Yoon, Byeung-Gil;Tak, Yang Ju;Lee, In-Soo
    • The Korean Journal of Emergency Medical Services
    • /
    • v.14 no.3
    • /
    • pp.95-105
    • /
    • 2010
  • Purpose: This study aims to investigate the operation of continuing education system and continuing education program for emergency medical technician in Korea, Japan and United States and develop reasonable operating scheme of continuing education and curriculum in order to provide the base data for the improvement of continuing education for the improved practice capability and its maintenance, Method: The overall review of continuing education for domestic 1st class emergency medical technician was performed and also the content of continuing education for Emergency Medical Technician - Paramedic in the United States and Paramedics of Fire Department with the license for the paramedic in Japan, have been analyzed through literature, books, articles, agencies' data, laws, and internet date. Result: Hours for domestic continuing education was 4-8 hours and it was only 3-11% compared to 72 hours in the United States and 128 hours in the Japan. And with respect to the types and methods of programs, there were differences both in quantity and quality. Conclusion: As an education, providing and supplementing the changed content and technical information for the improvement of the capability and qualification of emergency medical technician, selection of education hours and various continuing education should be continuously and regularly provided and conducted. The introduction of various continuing education system and programs for this is considered to be required.

  • PDF

A Development of Home Nursing Service System based Service Oriented Architecture (SOA) (SOA 기반의 가정간호서비스 시스템 개발)

  • Hong, Hae-Sook;Park, Chun-Bok;Kim, Hwa-Sun;Cho, Hun
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.11
    • /
    • pp.1680-1691
    • /
    • 2009
  • To improve the quality of healthcare and build up the health delivery system, electronic health record system is important for healthcare institutions providing health services. However, the systems currently operated in domestic healthcare institutions use independent software interface with distributed environment for data search and process. Therefore, it raises an additional expense to buy or develop each interface module when there is a link to new system and the problem of complexity. To solve these problems, this study implemented the service oriented architecture basis for home nursing service and carried out an assessment. The study defined the process modeling and business requirements based on the scenario of service and drew 17 suitable services based on five verification items for service design. To draw the final service, seven services were selected by service litmus test (SLT). The study found that, by the improvement of business process for healthcare service support department, SOA based information system has an effect of time reduction of patient processing time. In conclusion, to enable the hospital information system to cope with various demands of healthcare consumers, it is necessary to consider the application of SOA technology which has excellent interoperability, reusability and maintenance.

  • PDF

The Method of Effective DB Conversion and Related System Development for the Integrated KORMARC Format - Based on the Case of Sogang University Library - (통합서지형 KORMARC의 도입을 위한 효과적인 DB 변환과 시스템 구축 방안 - 서강대학교 도서관의 '자체 변환 방식'을 중심으로 -)

  • Lee, Kyu-Youn
    • Journal of Korean Library and Information Science Society
    • /
    • v.45 no.3
    • /
    • pp.93-117
    • /
    • 2014
  • The goal of this study is to seek for the method of effective DB conversion and related system development for the integrated KORMARC Format on the basis of the case of Sogang University Library. Since the integrated KORMARC bibliographic format was established, libraries have been converting bibliographic DB according to the new format. Loyola Library of Sogang University internally proceeded DB conversion using bibliographic DB convertor, which was developed and customized with a system vendor for Sogang University Library. The internal conversion enabled to correct or supplement bibliographic data errors. Besides, it enhanced stability of conversion and shortened the project time by adopting sampling conversion method. It was effective to reduce the additional work for DB quality maintenance, so this kind of conversion is recommendable to the library that has limited manpower for manual data correction.

Selection of Kentucky Bluegrass(Poa pratensis L.) Cultivar for Golf Courses in Korea (골프장에 적합한 켄터키 블루그래스 품종 선발)

  • Kim, Kyung-Duck;Tae, Hyun-Sook;Kim, Jong-Bo;Jang, Jae-Il;Oh, Sung-Bae
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.35 no.1 s.120
    • /
    • pp.88-93
    • /
    • 2007
  • Since the 1990s, the application of Kentucky bluegrass cultivars has increased in newly-constructed Korean golf courses as opposed to the previously-used zoysiagrass. However, there have been few reports studying the selection and characterization of these Kentucky bluegrass cultivars under Korean weather conditions. A total of 12 Kentucky bluegrass cultivars were tested for their adaptability in environmental stresses during summer conditions in Korea in order to select the best Kentucky bluegrass cultivars for use in Korean golf courses. This study found that two Kentucky bluegrass cultivars ('Midnight' and 'Bluestone') maintained their green throughout the summer season and had a high degree of root density, as compared to the other cultivars tested. These two cultivars also had a good rate of coverage in the early growth period. These characteristics make them suitable for application on sports fields and golf courses, which receive many divots and the frequent replacement of turfgrass sod caused by both biotic and abiotic stress. Two other cultivars, the 'Ginney' and 'Nuglade', also displayed good visual quality and high rate of coverage under summer conditions. In conclusion, the 'Midnight' and 'Bluestone' cultivars performed well in areas including the maintenance of their green color, the number of roots and the rate of coverage during the summer months. These characteristics are necessary for golf courses sports fields, which receive many divots and requirethe frequent replacement of turfgrass. further research on a range of Kentucky bluegrass cultivars, including a sensitivity test for many pathogens and recovery rates from a variety of stresses, is required in the near future.

Concentrations of total culturable microorganisms and Its Identification in Public Facilities (다중이용시설의 실내공기 중 총부유세균 농도와 종류)

  • Jeon, Byoung-Hak;Hwang, In Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.868-876
    • /
    • 2015
  • This study was conducted to measure the concentrations of total culturable bacteria (TCB) and to identify the bacteria in thirty public facilities (7 elderly-care facilities, 4 hypermarkets, 4 university hospitals, 7 child care facilities, 4 subway stations and 4 bus terminals) in Seoul and Gyeonggi-Do Province. Although all concentrations measured in these study facilities did not exceed the national maintenance standard, it is believed that elderly-, child-care facilities should be high priority facilities to improve the indoor air quality and it is important to study the health effects and the airborne bacteria concentration of public facilities including non-culturable bacteria or allergen.

Estimation of Air Voids in Asphalt Mixtures Using Ground-Penetrating Radar (지표투과레이더를 이용한 아스팔트 혼합물의 공극률 예측에 관한 연구)

  • Kim, Je Won;Kim, Yeon Tae;Kim, Booil;Park, Hee Mun
    • International Journal of Highway Engineering
    • /
    • v.18 no.4
    • /
    • pp.55-61
    • /
    • 2016
  • PURPOSES : The objective of this study was to determine the relationship between the dielectric characteristics of asphalt mixtures and the air voids present in them using ground penetrating radar (GPR) testing. METHODS : To measure the dielectric properties of the asphalt mixtures, the reflection coefficient method and the approach based on the actual thickness of the asphalt layer were used. An air-couple-type GPR antenna with a center frequency of 1 GHz was used to measure the time for reflection from the asphalt/base layer interface. A piece of aluminum foil was placed at the interface to be able to determine the reflection time of the GPR signal with accuracy. An asphalt pavement testbed was constructed, and asphalt mixtures with different compaction numbers were tested. After the GPR tests, the asphalt samples were cored and their thicknesses and number of air voids were measured in the laboratory. RESULTS : It was found the dielectric constant of asphalt mixtures tends to decrease with an increase in the number of air voids. The dielectric constant values estimated from the reflection coefficient method exhibited a slight correlation to the number of air voids. However, the dielectric constant values measured using the approach based on the actual asphalt layer thickness were closely related to the asphalt mixture density. Based on these results, a regression equation to determine the number of air voids in asphalt mixtures using the GPR test method was proposed. CONCLUSIONS : It was concluded that the number of air voids in an asphalt mixture can be calculated based on the dielectric constant of the mixture as determined by GPR testing. It was also found that the number of air voids was exponentially related to the dielectric constant, with the coefficient of determination, $R^2$, being 0.74. These results suggest that the dielectric constant as determined by GPR testing can be used to improve the construction quality and maintenance of asphalt pavements.

A Study on Area Planning of Air Conditioning Room for Hospital Design Focused on System (체계중심병원설계를 위한 공조실 면적 계획에 관한 연구)

  • Kim, Eun Seok;Yang, Nae Won
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.4
    • /
    • pp.27-35
    • /
    • 2019
  • Purpose: As the improvement in quality of medical environment and the spatial consideration for the prevention of infection in the hospital have become increasingly important in the recent years, specific and practical planning for air conditioning room's area has become a major issue accordingly. However, the air conditioning room tends to be discussed focusing on technical factors such as air conditioning systems that are irrelevant to building plans, while discussions of most departments related to the medical functions have actively taken placed. Therefore, this study aims to investigate the factors influencing the planning for the air conditioning room area, and through subsequent analysis of the area of the air conditioning room, to propose a way to improve effective planning for the air conditioning room area. Methods: This study examines the case hospitals that fall into two types: each floor supply system and concentrated supply system, and compares and analyzes the air conditioning room area-related factors and the characteristics of changes in the interior of air conditioning room before and after remodeling through air conditioning floor plan of those case hospitals. Results: The air conditioning room can be classified into the net area of the functional space such as duct passages, and the public area such as aisle space, and of those the public area is an important factor in calculating the area of the air conditioning room. The public area of the air-conditioning room should not be planned considering only the spaces for mobile passage or maintenance activities, but should be planned taking into account internal changes such as expansion and replacement of equipment in the future from the beginning. Implications: When planning a medical facility, it is used as basic data for the planning of the air conditioning room area, which is a significant fixed factor in the initial setting.

A Study on Algorithm for Materials Take-off Using Pothole Detection System (포트홀 감지 시스템을 이용한 보수재료량 산출 알고리즘 개발)

  • Kim, Kyungnam;Kim, Sung-Ho;Kim, Nakseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.3
    • /
    • pp.603-610
    • /
    • 2017
  • Various type of pavement deterioration such as crack, bumpy, pothole is rapidly increasing according to the accelerated environmental changes like heavy rainfall, frequent snowing, difference temperature, etc. Accident related to pothole that cause fatal traffic accidents has been increased more than five times over the next five years starting from 2008. As direct or indirect damage by pothole which caused injuries and car damages increases every year, quicker and more efficient management measures are necessary. This study presents the algorithm for materials quantity take-off. The algorithm was suggested by correlation in pothole size and area. Suggested algorithm were confirmed the validity through the 15 field survey in capital area. According to the results of survey, usually the residual materials at which 5~7 kg was generated decreased to 1~2 kg. It showed that automatic pothole detection system is expected not only to reduce materials and resources, but also to contribute to quality improvements of pavement through more accurate material take-off from the situation of constructing rely on their own judgement.

A Cost-Benefit Analysis of Groundwater: Pumping Wells in Korea (지하수의 경제성 평가 연구: 지하수 관정을 중심으로)

  • Kim, Sun Geun
    • Economic and Environmental Geology
    • /
    • v.47 no.3
    • /
    • pp.219-225
    • /
    • 2014
  • In Korea, there are 1,474 thousand pumping wells nationwide which account for about 12% of total water use in 2012. As much as 39 hundred million tons of groundwater were used while 333 hundred million tons of total water were supplied in 2012. Because the water management authority projects that water demand will exceed supply by 2021, the authority is planning to extensively expand groundwater use in accordance with economic feasibility. Using the basic frameworks of cost-benefit analyses of the World Bank and the US Environmental Protection Agency (US EPA), the objective of this study is to examine the costs and benefits of the expansion of Korea's groundwater extraction through pumping wells. We conclude that the BC ratio of the groundwater pumping wells is 2.98. This signifies that the benefits are 2.98 times higher than the costs. The benefits include use and non-use values of pumping wells while the costs include the installation and maintenance of new wells, in addition to the restoration and pollution costs of abandoned wells, as well as fees for water quality tests, etc.