• Title/Summary/Keyword: Quality Control(QC)

Search Result 178, Processing Time 0.026 seconds

Sensitivity and Scoring of AutoPap 300 QC System for Abnormal Cervicovaginal Cytology (비정상 자궁경부도말에서 AutoPap 300 QC System의 민감도와 Score에 영향을 주는 인자의 평가)

  • Hong, Sung-Ran
    • The Korean Journal of Cytopathology
    • /
    • v.9 no.2
    • /
    • pp.139-146
    • /
    • 1998
  • The AutoPap 300 QC System is an automated device for the analysis and classification of conventional cervical cytology slides for quality control purpose. These studies evaluated the sensitivity of the AutoPap 300 QC System, and estimated morphologic features other than epithelial abnormality to identify a high quality control(QC) score with the AutoPap 300 QC System. The sensitivity of the AutoPap 300 QC System at 10% review rate for 210 cases of cervicovaginal cytology with low grade squamous intraepithelial lesion(LSIL) and higher grade lesion was assessed, and compared with a 10% random rescreening. The morphologic features, such as presence of endocervical component, dirty background, atrophy, abnormal ceil size, and celluiarity of single atypical cells were estimated in 45 cases of no review and 30 cases of QC review cases. The AutoPap 300 QC System identified 119(56.7%) out of 210 cases with LSIL and higher grade lesion at 10% review rate. It was more sensitive to squamous cell lesions$(50{\sim}62%)$ than to glandular lesions(10%). The dirty background and the scanty cellularity of single atypical cells were significantly related to low QC score. Conclusively, AutoPap 300 QC System is superior to human random rescreen for the identification of false negative smears. The upgrading of this device is required to enhance the defection of glandular lesion and certain Inadequate conditions of the slides.

  • PDF

An Influence of Introduction of Full-time Quality Control Personnel System On Audit Quality (품질관리 전담자 제도 도입이 감사품질에 미치는 영향)

  • Sug, Wan-Joo;Park, Kyoung-Ho
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.9
    • /
    • pp.75-83
    • /
    • 2021
  • This research is to analyze how an introduction of full-time quality control("QC") personnel system in audit firms influences on audit quality and verify how important it is to establish the quality control system for auditing quality. We measure audit quality as the level of discretionary accruals and compare the differences between audit firms with QC and without QC. In addition, we analyze the difference in audit qualities between before and after activating the full-time QC personnel system by comparing audit quality of before 2015 with that of after 2016. The results of this study are summarized as follows. First, the audit quality is higher when audit firms have QC personnel. Second, the audit quality is improved after the introduction of the full-time QC personnel system.

New methods for optical distance indicator and gantry angle quality control tests in medical linear accelerators: image processing by using a 3D phantom

  • Shandiz, Mahdi Heravian;Layen, Ghorban Safaeian;Anvari, Kazem;Khalilzadeh, Mohammadmahdi
    • Radiation Oncology Journal
    • /
    • v.33 no.1
    • /
    • pp.42-49
    • /
    • 2015
  • Purpose: In order to keep the acceptable level of the radiation oncology linear accelerators, it is necessary to apply a reliable quality assurance (QA) program. Materials and Methods: The QA protocols, published by authoritative organizations, such as the American Association of Physicists in Medicine (AAPM), determine the quality control (QC) tests which should be performed on the medical linear accelerators and the threshold levels for each test. The purpose of this study is to increase the accuracy and precision of the selected QC tests in order to increase the quality of treatment and also increase the speed of the tests to convince the crowded centers to start a reliable QA program. A new method has been developed for two of the QC tests; optical distance indicator (ODI) QC test as a daily test and gantry angle QC test as a monthly test. This method uses an image processing approach utilizing the snapshots taken by the CCD camera to measure the source to surface distance (SSD) and gantry angle. Results: The new method of ODI QC test has an accuracy of 99.95% with a standard deviation of 0.061 cm and the new method for gantry angle QC has a precision of $0.43^{\circ}$. The automated proposed method which is used for both ODI and gantry angle QC tests, contains highly accurate and precise results which are objective and the human-caused errors have no effect on the results. Conclusion: The results show that they are in the acceptable range for both of the QC tests, according to AAPM task group 142.

A Case Study of Quality Assurance and Control for the Soil Environmental Assessment in Abandoned Mine (광산지역 토양정밀조사 정도관리(QA/QC) 사례 연구)

  • Ji, Won Hyun;Kim, Jong Keun
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.3
    • /
    • pp.134-141
    • /
    • 2014
  • A testing inspection is one of the important in the industry, owing to determine the reliability and directivity of testing inspection results. Therefore, the quality assurance and quality control (QA/QC) work which performed by personnel not directly in the inventory compilation development, in testing inspection must be thoroughly considered. Some agencies for environmental test inspection, they sometimes misunderstood that the QA/QC was ended with proficiency testing performance and on-site assessment by a director. Thus, results were often calculated without QA/QC work by self manual when conducting test. The objective of this study was to improve reliability of testing and inspection agency through the QA/QC case study which basically performed to raising reliability of testing and inspection agency. In this study, it increased reliability of result by verifying calibration curve (IC, ICV, CCV), blank, accuracy (LCS, MS) and precision as QA/QC performance, while performing investigation of soil contamination in mining areas. This study suggests that reliability establishing method of test result and management method of analysis process, through the QA/QC instance of testing agency.

Effect of Quercetin and Methoxylated Quercetin on Chicken Thigh Meat Quality during Cold Storage (Quercetin과 Methoxylated Quercetin이 육계 다리육의 저장 품질에 미치는 영향)

  • Jang, Ae-Ra;Ham, Jun-Sang;Kim, Dong-Wook;Chae, Hyun-Seok;Kim, Dong-Wook;Kim, Sang-Ho;Seol, Kuk-Hwan;Oh, Mi-Hwa;Kim, Dong-Hun
    • Korean Journal of Poultry Science
    • /
    • v.38 no.4
    • /
    • pp.265-273
    • /
    • 2011
  • This study was carried out to determine the effect of dietary supplementation of quercetin and methoxylated quercetin extracted from onions on chicken thigh meat quality during cold storage. For 35 days, 1-day-old 320 broiler chicks (Ross) were divided into 8 groups and supplemented the diet; basal diet only (CONTROL), CONTROL with antibiotics (AB), vitamin E 20 IU (VE20), vitamin E 200 IU (VE200), quercetin 20 ppm (QC20), quercetin 200 ppm (QC200), methoxylated quercetin 20 ppm (MQ20), and methoxylated quercetin 200 ppm (MQ200). After slaughtering the broilers, thighs were separated and analyzed the quality change of the meat during storage at $4^{\circ}C$ for 7 days. The meat quality factors such as pH, color, water holding capacity, and sensory characteristics of thigh meat were determined on the experiment day 0, 3, and 7. After slaughtering, the pH of AB, VE 20, QC 20, and MQ 200 showed no significant difference compare to that of CONTROL. However, VE 200 and QC 20 showed higher pH value than CONTROL on storage day 3. $L^*$ value of chicken thigh of MQ 20 was lower than CONTROL on storage day 0, however, no significant difference was found between CONTROL and treatments on storage day 3. Redness ($a^*$) of chicken thigh in CONTROL was increased during storage. QC 20, QC 200, and MQ 200 significantly reduced the $b^*$ value of chicken thigh (p<0.05). Water holding capacity of VE 20 and MQ 200 was significantly higher than the CONTROL on the day 0. Also, QC 200 showed higher WHC compare to the CONTROL. In sensory evaluation, overall acceptability of chicken thigh in quercetin and methoxylated quercetin group showed no significant differences compare to that of CONTROL by storage day 3. These results suggested that the quercetin and methoxylated quercetin could be used as additives to enhance broiler thigh meat quality such as pH and WHC without adverse effect on color and sensory characteristics.

THE HISTRICAL CHANGES OF JAPANESE QUALITY CONTROL AND TRENDS AND TASKS OF QUALITY ISSUES

  • Tanaka Hiroshi
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 1998.11a
    • /
    • pp.407-412
    • /
    • 1998
  • TQC, the features of Japanese QC (JQC), is forced to change now. There are many problems related to QC field, such as magnification of quality objects, social quality, thoroughness of CS, enforcement of PL law, applications of ISO standards concerning the QA system and the environmental management system, and still more recent American industrial tendency which attaches importance to TQM and so forth. Qn the occasion of JQC have passed for fifty years, since 1945. I would like to look back upon its QC history and discuss the meaning of the recent changes in QC concepts and the theoretical framework of its QC.

  • PDF

Development of Quality Control Method for Visibility Data Based on the Characteristics of Visibility Data (시정계 자료 특성을 고려한 시정계 자료 품질검사 기법 개발)

  • Oh, Yu-Joo;Suh, Myoung-Seok
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_1
    • /
    • pp.707-723
    • /
    • 2020
  • In this study, a decision tree type of quality control (QC) method was developed to improve the temporal-spatial representation and accuracy of the visibility data being operated by the Korea Meteorological Administration (KMA). The quality of the developed QC method was evaluated through the application to the 3 years (2016.03-2019.02) of 290 stations visibility data. For qualitative and quantitative verification of the developed QC method, visibility and naked-eye data provided by the KMA and QC method of the Norwegian Meteorological Institute (NMI) were used. Firstly, if the sum of missing and abnormal data exceeds 10% of the total data, the corresponding point was removed. In the 2nd step, a temporal continuity test was performed under the assumption that the visibility changes continuously in time. In this process, the threshold was dynamically set considering the different temporal variability depending on the visibility. In the 3rd step, the spatial continuity test was performed under the assumption of spatial continuity for visibility. Finally, the 10-minute visibility data was calculated using weighted average method, considering that the accuracy of the visibility meter was inversely proportional to the visibility. As results, about 10% of the data were removed in the first step due to the large temporal-spatial variability of visibility. In addition, because the spatial variability was significant, especially around the fog area, the 3rd step was not applied. Through the quantitative verification results, it suggested that the QC method developed in this study can be used as a QC tool for visibility data.

Quality Control of Diagnostic X-ray Units for Animal Hospital (동물병원의 방사선발생장치 정도관리에 대한 연구)

  • Kim, Sang-Woo;Lee, Ji-Hoon;Park, Yei-Seul;Rhim, Jea-Dong;Seoung, Youl-Hun
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2010.04a
    • /
    • pp.231-237
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using quality assurance (QA) and quality control (QC) of diagnostic X-ray units. The surveys for QA/QC, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The QA/QC included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. As a result, 44.44% of reproducibility of dose exposure was proper, 81. 25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test.

  • PDF

A Study of Iterative QC-BC Method for AMSU-A in the KIAPS Data Assimilation System (KIAPS 자료동화 시스템에서 AMSU-A의 품질검사 및 편향보정 반복기법에 관한 연구)

  • Jeong, Han-Byeol;Chun, Hyoung-Wook;Lee, Sihye
    • Atmosphere
    • /
    • v.29 no.3
    • /
    • pp.241-255
    • /
    • 2019
  • Bias correction (BC) and quality control (QC) are essential steps for the proper use of satellite observations in data assimilation (DA) system. BC should be calculated over quality controlled observation. And also QC should be performed for bias corrected observation. In the Korea Institute of Atmospheric Prediction Systems (KIAPS) Package for Observation Processing (KPOP), we adopted an adaptive BC method that calculates the BC coefficients with background at the analysis time rather than using static BC coefficients. In this study, we have developed an iterative QC-BC method for Advanced Microwave Sounding Unit-A (AMSU-A) to reduce the negative feedback from the interaction between BC and QC. The new iterative QC-BC is evaluated in the KIAPS 3-dimensional variational (3DVAR) DA cycle for January 2016. The iterative QC-BC method for AMSU-A shows globally significant benefits for error reduction of the temperature. The positive impacts for the temperature were predominant at latitudes of $30^{\circ}{\sim}90^{\circ}$ of both hemispheres. Moreover, the background warm bias across the troposphere is decreased. Even though AMSU-A is mainly designed for atmospheric temperature sounding, the improvement of AMSU-A pre-processing module has a positive impact on the wind component over latitudes of $30^{\circ}S$ near upper-troposphere, respectively. Consequently, the 3-day-forecast-accuracy is improved about 1% for temperature and zonal wind in the troposphere.

Understanding and Misuse Type of Quality Improvement Tools According to the Kind of Data and the Number of Population in DMAIC Process of Six Sigma (식스시그마 DMAIC 프로세스에서 모집단의 수와 데이터 종류에 따른 품질개선 기법의 오적용 유형 및 이해)

  • Choi, Sung-Woon
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2010.04a
    • /
    • pp.509-517
    • /
    • 2010
  • The paper proposes the misuse types of statistical quality tools according to the kind of data and the number of population in DMAIC process of six sigma. The result presented in this paper can be extended to the QC story 15 steps of QC circle. The study also provides the improvement methods about control chart, measurement system analysis, statistical difference, and practical equivalence.

  • PDF