• 제목/요약/키워드: Quality Control(QC)

검색결과 179건 처리시간 0.024초

Comparison of the MGISEQ-2000 and Illumina HiSeq 4000 sequencing platforms for RNA sequencing

  • Jeon, Sol A;Park, Jong Lyul;Kim, Jong-Hwan;Kim, Jeong Hwan;Kim, Yong Sung;Kim, Jin Cheon;Kim, Seon-Young
    • Genomics & Informatics
    • /
    • 제17권3호
    • /
    • pp.32.1-32.6
    • /
    • 2019
  • Currently, Illumina sequencers are the globally leading sequencing platform in the next-generation sequencing market. Recently, MGI Tech launched a series of new sequencers, including the MGISEQ-2000, which promise to deliver high-quality sequencing data faster and at lower prices than Illumina's sequencers. In this study, we compared the performance of two major sequencers (MGISEQ-2000 and HiSeq 4000) to test whether the MGISEQ-2000 sequencer delivers high-quality sequence data as suggested. We performed RNA sequencing of four human colon cancer samples with the two platforms, and compared the sequencing quality and expression values. The data produced from the MGISEQ-2000 and HiSeq 4000 showed high concordance, with Pearson correlation coefficients ranging from 0.98 to 0.99. Various quality control (QC) analyses showed that the MGISEQ-2000 data fulfilled the required QC measures. Our study suggests that the performance of the MGISEQ-2000 is comparable to that of the HiSeq 4000 and that the MGISEQ-2000 can be a useful platform for sequencing.

산성비의 pH 측정에 대한 연구 (A Study on the Electrometric Measurement of the pH of Acid Rain)

  • 이화심;김명수
    • 대한화학회지
    • /
    • 제44권1호
    • /
    • pp.10-16
    • /
    • 2000
  • 일반적으로 산성비는 이온세기가 낮아 저항이 크고 완충능이 없는 용액이다. 그러므로 산성비의 pH측정 시, 시료용액의 액간접촉전위는 이온세기의 차이로 인해 pH표준용액의 액간접촉전위와 달라서 pH 측정값에 오차가 발생될 수 있다. 실제 1998년도 대덕연구단지에 내린 빗물의 평균 전도도 값이 12.8 ${\mu}S/cm$인데 비해, pH 표준용액의 전도도 값은 약 5,980 ${\mu}S/cm$으로 이온세기의 차이가 크다. 본 연구에서는 산성비의 pH를 측정할 때 액간접촉전위로 인해 발생되는 오차를 보정하기 위해, 빗물과 비슷한 pH와 전도도를 가지는 묽은 황산의 물성조절표준물(Quality Control Standard, 이하 QCS로 표기)을 제조하여 사용하였다. QCS의 pH값을 액간접합이 없는 수소전극 시스템으로 인증한 다음, 유리전극으로 다시 pH를 측정하여 그 차이값 만큼 보정하였다. 아울려 이 방법으로 1998년도 대덕연구단지에 내린 빗물의 pH를 측정하였다.

  • PDF

멀티미디어 서비스 품질 제어를 위한 QoS 파라미터와 QoE 요소간의 연동 제어 시스템 설계 (Design of Interworking Control System between QoS Parameters and QoE Items to Control Multimedia Services Quality)

  • 김현종;윤동근;최성곤
    • 한국콘텐츠학회논문지
    • /
    • 제10권4호
    • /
    • pp.45-54
    • /
    • 2010
  • 본 논문에서 우리는 차세대 통합망 환경에서 다양한 멀티미디어 서비스를 이용하는 서비스 이용자의 체감 품질이 저하될 경우 체감 품질과 관련된 QoS 파라미터를 네트워크 계층에서 제어함으로써 품질 만족도를 향상시킬 수 있는 품질 연동 제어 시스템을 제안한다. 제안된 시스템은 RTCP와 같은 제어 패킷을 통해 네트워크 계층의 QoS 파라미터 정보를 수집하고 이 수집된 정보를 이용하여 멀티미디어 서비스의 QoE를 평가한다. 이렇게 평가된 QoE와 응용계층에서 측정된 QoE와 비교하여 기준값보다 낮을 경우 품질 저하로 판단하고 이와 관련된 QoS 파라미터 도출 및 각 파라미터의 상대적 중요도를 결정한다. 결정된 정보를 토대로 QCS는 서비스 품질 제어 시스템(SCS)에서 각 라우터 및 스위치에 적용하는 정책(policy)의 기반이 될 수 있는 QoS 제어값 정보를 생성하여 SCS로 전송한다. 이런 제안된 시스템을 통해 서비스 및 네트워크 사업자들은 서비스 특성 및 네트워크 상황을 고려하여 서비스 이용자에게 향상된 품질의 멀티미디어 서비스를 제공할 수 있다.

도시철도운영기관의 종합신뢰성 경영시스템 적용방안 연구 (Dependability Management System's Application to Subway Corporation)

  • 하천수;홍순기;이호용;한석윤
    • 한국철도학회논문집
    • /
    • 제8권3호
    • /
    • pp.286-292
    • /
    • 2005
  • In this paper, we introduce IEC 60300(Dependability program management) into urban transit system, and propose effective method to apply IEC 60300 to Subway Corporation. The dependability is the collective term used to describe the availability performance and its influencing factors such as reliability performance, maintainability performance and maintenance support performance. A dependability program covers all phases of a system's life cycle from planning to operation and possibly disposal, and is composed of program elements divided into tasks.

품질관리표본(Quality Control Sample)의 리인터뷰에 의한 사업체조사의 응답오차 측정

  • 김설희;박현영
    • 한국통계학회:학술대회논문집
    • /
    • 한국통계학회 2003년도 추계 학술발표회 논문집
    • /
    • pp.53-58
    • /
    • 2003
  • 최근 경제 사회의 급속한 발전에 따라 개인의 활동분야가 다양해지고 개인비밀보호 인식이 커지면서 응답자들이 통계조사에 잘 협조하지 않는 경우가 늘어나고 있다. 따라서 대부분의 통계를 현장조사에 의존하여 생산하고 있는 통계청에서는 현장조사 결과물의 품질상태에 좀 더 관심을 가져야만 하게 되었다. 이러한 현장조사에 대한 풀질관리의 일환으로 현재 통계청에서는 통계별 조사대상으로부터 품질관리표본(Quality Control Sample)을 추출하고 이를 대상으로 리인터뷰를 실시함으로써 응답오차측정, 조사현장의 실터파악, 응답자 의견수렴 등에 활용하고 있다. 리인터뷰는 조사직원의 고의적인 자료조작 또는 보충교육 필요성 등 현장조사업무를 평가하거나 응답분산(simple response variation), 응답편의(response bias) 등을 산출하고, 이를 분석하는 모델을 이용하여 응답결과의 신뢰도를 분석하는데 목적을 두고 있다. 본 연구에서는 품질관리표본(QC Sample) 설계 및 추출, 리인터뷰 시나리오개발, CATI(Computer Assisted Telephone Interviewing)를 이용한 리인터뷰 기법 등을 통계청 사업체조사 모니터링 사례를 중심으로 설명하고 조사직원 특성별 응답오차 측정 및 비교, 정확성 항목에 대한 차이분석 등 격과에 대하여 논하고자 한다.

  • PDF

LC/MS/MS를 이용한 원숭이 혈액에서의 Doxifluridine과 대사체 5-FU 동시분석법 개발 및 Validation (Quantitative Determination of Doxifluridine and 5-FU in Monkey Serum Using LC/MS/MS)

  • 우영아;김기환;김원;이종화;정은주;김진호;박귀례;김충용
    • 약학회지
    • /
    • 제51권3호
    • /
    • pp.174-178
    • /
    • 2007
  • A reverse-phase high performance liquid chromatography method with electrospray ionization and detection by mass spectrometry is described for the simultaneous determination of doxifluridine and its active metabolite 5-flu-orouracil (5-FU) in monkey serum. The method has greater sensitivity and simpler process than previous published methods with good accuracy and precision. A proper liquid/liquid extraction was used to extract simultaneously doxifluridine and 5-FU which has considerable difference in the polarity. Extracts were analyzed using LC/MS/MS providing a short analysis time within 5 min. The lower limit of quantification was validated at 10.0 ng/ml of serum for both doxifluridine and 5-FU. Accuracy and precision of quality control (QC) samples for both analytes met FDA Guidance criteria of ±15% for average QC accuracy with coefficients of variation less than 15%. The method will be applicable for preclinical studies and bioequivalence studies.

QC담당자의 인식 및 실행이 사후관리에 미치는 영향에 관한 연구: KS인증 공장심사 평가항목을 중심으로 (A Study on the Effect of Perception and Practice of QC Personnel on Post-Management: Focusing on KS Certified Factory Evaluation Criteria)

  • 유연택;홍정의;김광수
    • 대한안전경영과학회지
    • /
    • 제26권2호
    • /
    • pp.107-115
    • /
    • 2024
  • This study conducted frequency analysis, reliability analysis, descriptive statistics, and correlation analysis to determine the impact of quality control managers' perception and implementation of KS certification factory inspection evaluation items on follow-up management. Through a multiple linear regression model, the influence of KS certification officer's awareness and implementation of KS certification factory inspection on post management was found to have a positive (+) influence on post management, with implementation having a greater influence on post management than awareness. It was having an impact. The independent variable (perception) has a statistically significant impact on the mediating variable (execution), and in the stage of verifying the mediating effect, the influence of the independent variable (perception) on the dependent variable (follow-up management) has a statistically significant impact. , In the stage where the independent variable (perception) and the mediator (implementation) are input simultaneously, both the independent variable and the mediator have a statistically significant effect on the dependent variable, indicating that there is a mediation effect.

영상장치 센서 데이터 QC에 관한 연구 (A study on imaging device sensor data QC)

  • 윤동민;이재영;박성식;전용한
    • Design & Manufacturing
    • /
    • 제16권4호
    • /
    • pp.52-59
    • /
    • 2022
  • Currently, Korea is an aging society and is expected to become a super-aged society in about four years. X-ray devices are widely used for early diagnosis in hospitals, and many X-ray technologies are being developed. The development of X-ray device technology is important, but it is also important to increase the reliability of the device through accurate data management. Sensor nodes such as temperature, voltage, and current of the diagnosis device may malfunction or transmit inaccurate data due to various causes such as failure or power outage. Therefore, in this study, the temperature, tube voltage, and tube current data related to each sensor and detection circuit of the diagnostic X-ray imaging device were measured and analyzed. Based on QC data, device failure prediction and diagnosis algorithms were designed and performed. The fault diagnosis algorithm can configure a simulator capable of setting user parameter values, displaying sensor output graphs, and displaying signs of sensor abnormalities, and can check the detection results when each sensor is operating normally and when the sensor is abnormal. It is judged that efficient device management and diagnosis is possible because it monitors abnormal data values (temperature, voltage, current) in real time and automatically diagnoses failures by feeding back the abnormal values detected at each stage. Although this algorithm cannot predict all failures related to temperature, voltage, and current of diagnostic X-ray imaging devices, it can detect temperature rise, bouncing values, device physical limits, input/output values, and radiation-related anomalies. exposure. If a value exceeding the maximum variation value of each data occurs, it is judged that it will be possible to check and respond in preparation for device failure. If a device's sensor fails, unexpected accidents may occur, increasing costs and risks, and regular maintenance cannot cope with all errors or failures. Therefore, since real-time maintenance through continuous data monitoring is possible, reliability improvement, maintenance cost reduction, and efficient management of equipment are expected to be possible.

병원 등급에 따른 X선조사야와 광조사야 간의 면적 및 중심점 오차 비교 (Comparison of Center Error or X-ray Field and Light Field Size of Diagnostic Digital X-ray Unit according to the Hospital Grade)

  • 이원정;송규리;신현이
    • 한국방사선학회논문지
    • /
    • 제14권3호
    • /
    • pp.245-252
    • /
    • 2020
  • 본 연구에서는 병원 등급에 따른 X선조사야와 광조사야 간의 면적 차이와 중심점 오차를 측정하여 비교함으로써 피폭을 낮추고 화질 향상을 위해 정도관리의 중요성을 인식하고자 하였다. 00광역시에 소재한 10개 병원의 디지털 일반촬영장치 12대를 대상으로 X선조사야와 광조사야의 중심점을 측정하였다. 병원 등급별로는 대학병원(university hospital) 3대, 종합병원(general hospital) 3대, 병원(hospital) 4대, 의원(clinic)에서 2대를 실시하였다. 표준화된 모눈종이 위에 투명 플라스틱판을 붙인 후 철사(0.8mm)를 이용하여 각각 다른 넓이로 팬텀을 제작하였고, 팬텀 중앙에 철사로 중심을 표시하였다. 디지털 일반촬영장치 테이블 위에 팬텀을 위치시킨 후 수직으로 각 조사야 별로 노출 시킨 후 영상을 얻었다. 모든 영상은 SSD 100cm에서 동일한 노출 조건으로 획득하였고, 의료영상저장전송시스템(PACS, picture archiving communication system)을 이용하여 조사야 및 오차 길이를 측정하고 비교하였다. 측정 데이터는 평균과 표준오차로 나타낸 후 SPSS ver. 22.0을 이용하여 분석하였다. 의원이 X선조사야와 광조사야 간에 면적차이가 가장 적었고, 그다음 대학병원, 병원, 종합병원이 가장 컸다. 중심점 오차가 가장 적은 대학병원을 기준으로 의원 간에 통계학적인 유의한 중심점 오차 차이를 보였다(p=0.024). 중심점 오차는 36개월 미만 그룹이 36개월 그룹보다 통계학적으로 유의하게 적은 오차를 보였다(0.26 vs. 0.88, p=0.036). X선조사야와 광조사야 간에 면적 차이는 의원이 가장 적었고, 중심점 오차는 대학병원이 가장 적었다. 또한, 정도관리 후 사용기간이 짧은 병원이 중심점 오차가 적은 것으로 나타나 정도관리 항목에 따른 수시정도관리 도입이 필요하였다.

적설 관측자료 비교를 통한 정량적 SWE 산출에 관한 연구 (A Study of Quantitative Snow Water Equivalent (SWE) Estimation by Comparing the Snow Measurement Data)

  • 노용훈;장기호;차주완;정건희;최지원;하종철
    • 대기
    • /
    • 제29권3호
    • /
    • pp.269-282
    • /
    • 2019
  • While it is important to obtain the accurate information on snowfall data due to the increase in damage caused by the heavy snowfall in the winter season, it is not easy to observe the snowfall quantitatively. Recently, snow measurements using a weighing precipitation gauge have been carried out, but there is a problem that high snowfall intensity results in low accuracy. Also, the observed snowfall data are sensitive depending on wind speed, temperature, and humidity. In this study, a new process of quality control for snow water equivalent (SWE) data of the weighing precipitation gauge were proposed to cover the low accuracy of snow data and maximize the data utilization. Snowfall data (SWE) observed by Pluvio, Parsivel, snow-depth meter using laser or ultrasonic, and rainfall gauge in Cloud Physics Observation Site (CPOS) were compared and analyzed. Applying the QC algorithm including the use of number of hydrometeor particles as reference, the increased SWE per the unit time was determined and the data noise was removed and marked by flag. The SWE data converted by the number concentration of hydrometeor particles are tested as a method to restore the QC-removed data, and show good agreement with those of the weighing precipitation gauge, though requiring more case studies. The three events data for heavy snowfall disaster in Pyeongchang area was analyzed. The SWE data with improved quality was showed a good correlation with the eye-measured data ($R^2$ > 0.73).