• Title/Summary/Keyword: QRS complex

Search Result 132, Processing Time 0.022 seconds

An implementation of automated ECG interpretation algorithm and system(III) - Detector of atrium and ventricle activity (심전도 자동 진단 알고리즘 및 장치 구현(III) - 심방 및 심실활동 검출기)

  • Kweon, H.J.;Lee, J.W.;Yoon, J.Y.;Choi, S.K.;Lee, J.Y.;Lee, M.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.288-292
    • /
    • 1996
  • This paper describes far the detection of heart event that is, QRS complex and P wave which are result from heart activity. The proposed QRS detection method by using the spatial velocity was identified as having the 99.6% detection accuracy as well as fast processing time. Atrial flutter, coupled P wave, and noncoupled P wave as well as atrial fibrillation could be detected correctly by three different algorithms according to their origination farm. About 99.6% correction accuracy coupled P wave could be obtained and we could be found that most detection errors are caused by establishing wrong search interval.

  • PDF

A Study on The Method of Real-Time Arrythmia monitoring Using Modified Chain Coding (Modified Chain Coding 을 이용한 실시간 부정맥 모니터링 기법에 관한 연구)

  • Yun, Ji-Young;Lee, Jeong-Whan;Lee, Myoung-Ho
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.31-35
    • /
    • 1996
  • This paper presents a real time algorithm for monitoring of the arrythmia of ECG signal. A real time monitoring, following by detecting a QRS complex, is the most important. Using 2-dimensional time-delay coordinates which are reconstructed by the phase portrait plotting special trajectory, we detect QRS complexes. In this study, arrythmias are detected by matching the past standard template with tile present pattern when changing abruptly In order to matching with each other, we propose modified chain coding algorithm which applies vetor table consisting of eight orthonormal code(=binary code) to the phase portraits. This algorithm using logical function increases the weight if exceeding to the threshold determinded by correlation value and the distance from a straight line(y=x). Evaluating the performance of the proposed algorithm, we use standard MIT/BIH database. The results are fellowing, 1) Improve the speed of matching template than that of cross-correlation ever has been used. 2) Because the proposed algorithm is robust to varing fiducial point, it is possible to monitor the ECG signal with irregular RR interval. 3) In spite of baseline wandering owing to the low frequency noise, monitoring performance is not reduced.

  • PDF

Experimental Studies on Induced Traumatic Pericarditis and Myocarditis in Ruminants (반추수(反芻獸)의 창상성심낭심근염(創傷性心囊心筋炎)에 관(關)한 실험적연구(實驗的硏究))

  • Cheong, C.K.;Nam, T.C.;Seung, J.K.;Oak, J.W.
    • Korean Journal of Veterinary Research
    • /
    • v.20 no.2
    • /
    • pp.127-134
    • /
    • 1980
  • This study was performed to obtain an accurate methods of diagnosis in early stage of traumatic pericarditis and myocarditis in ruminants. Korean native goats were used as experimental animal and traumatic pericarditis and myocarditis were induced by surgical intervention. The changes in clinical signs, hematological values, blood enzymes and electrocardigrams were observed for 14 days after operation. The results obtained were as follows: 1. Body temperature in experimental group of induced traumatic pericarditis and myocarditis was slightly increased than control group that was rumenotomized. Heart rate was increased in both groups but the increased rate was noticed remarkably in experimental group. There was no change in respiratory rate in experimental and control group. 2. Total leucocytes counts and neutrophil percentage maintained higher level after operation and lymphocytes percentage noticed reversed proportion to neutrophil in both groups. 3. Serum total protein concentration and alkaline phosphatase activities after operation showed a little lower levels than these values prior to operation. Serum glutamic oxaloacetic transaminase and lactic dehydrogenase activities in control group showed slight increase through all the experimental period, while in experimental group these activities were markedly elevated and an increase in serum lactic dehydrogenase activities was more remarkable comparing to serum glutamic oxaloacetic transaminase. 4. Electrocardiograms in control group did not show any abnormalities except for slight increase in heart rate. In experimental group the amplitude of QRS complex was increased in duration of experimental period. The transference from QRS complex to T wave was uncertain and S-T segment moved upward obliquely through electrical zero line.

  • PDF

Research on improving correctness of cardiac disorder data classifier by applying Best-First decision tree method (Best-First decision tree 기법을 적용한 심전도 데이터 분류기의 정확도 향상에 관한 연구)

  • Lee, Hyun-Ju;Shin, Dong-Kyoo;Park, Hee-Won;Kim, Soo-Han;Shin, Dong-Il
    • Journal of Internet Computing and Services
    • /
    • v.12 no.6
    • /
    • pp.63-71
    • /
    • 2011
  • Cardiac disorder data are generally tested using the classifier and QRS-Complex and R-R interval which is used in this experiment are often extracted by ECG(Electrocardiogram) signals. The experimentation of ECG data with classifier is generally performed with SVM(Support Vector Machine) and MLP(Multilayer Perceptron) classifier, but this study experimented with Best-First Decision Tree(B-F Tree) derived from the Dicision Tree among Random Forest classifier algorithms to improve accuracy. To compare and analyze accuracy, experimentation of SVM, MLP, RBF(Radial Basic Function) Network and Decision Tree classifiers are performed and also compared the result of announced papers carried out under same interval and data. Comparing the accuracy of Random Forest classifier with above four ones, Random Forest is the best in accuracy. As though R-R interval was extracted using Band-pass filter in pre-processing of this experiment, in future, more filter study is needed to extract accurate interval.

Minimizing Algorithm of Baseline Wander for ECG Signal using Morphology-pair (Morphology-pair를 이용한 심전도 신호의 기저선 변동 잡음 제거 알고리즘)

  • Kim, Sung-Wan;Kim, Se-Yun;Kim, Tae-Hun;Choi, Byung-Jae;Park, Kil-Houm
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.4
    • /
    • pp.574-579
    • /
    • 2010
  • The baseline wander is most fatal noise, because it obstructs reliable diagnosis of cardiac disorder. Thus, in this paper, the morphology-pair is proposed for estimation of baseline wander except P, T-wave and QRS-complex. Proposed Morphology-pair is able to except P, R, T-wave which have characteristics of local maxima. Likewise Q, S-wave such as local minima are excepted by proposed Morphology-pair. The final baseline wander eliminated ECG signal is deducted by subtraction of original ECG and estimated baseline wander. The experimental results based on the MIT/BIH database show that the proposed algorithms produce promising results.

Studies on the Electrocadiogram in Non-human Primates Reared in Korea (國內 飼育 원숭이의 心電圖에 관한 硏究)

  • 서진석;서지민;이버들;송근호;이수진;김덕환;현병화;신남식
    • Journal of Veterinary Clinics
    • /
    • v.19 no.2
    • /
    • pp.132-138
    • /
    • 2002
  • Non-human primates are widely used for experimental animal and raised as companion animal in Korea. To establish the electrocadiogram (ECG) of non-human primates that are domestically raised, the author measured bipolar limb leads and augmented unipolar limb leads, after tiletamine/zolazepam (TZ) injection as sedative agents. The amplitudes of P,Q, R,S and T wave and duration time of P wave, QRS complex, PR and QT interval in each lead of ECG were evaluated in 7 non-human primates at 15 minutes after TZ injection, respectively. The amplitude of P wave in I, II,III, aVR, aVL and aVF leads revealed 0.06$\pm$ 0.05,0.14$\pm$ 0.05, 0.1 $\pm$ 0.05,-0.11 $\pm$ 0.06,-0.04$\pm$ 0.04 and 0.12$\pm$ 0.05 mV respectively. The amplitude of Q wave revealed -0.16$\pm$ 0.15, -0.23$\pm$ 0.18, -0.17$\pm$ 0.13, 0.16$\pm$0.13, 0.04$\pm$ 0.09 and -0.2$\pm$0.13 mV, respectively. The amplitude of R wave revealed 0.56$\pm$0.56, 1.24$\pm$ 0.67, 0.92$\pm$0.33, -0.37$\pm$ 1.14, -0.22$\pm$ 0.47 and 1.12 $\pm$ 0.47 mV, respectively. The amplitude of S wave revealed -0.02$\pm$ 0.08, -0.04$\pm$0.06, -0.06$\pm$0.04, 0.02$\pm$0.04, 0.04$\pm$0.09 and -0.04 $\pm$ 0.06 mV, respectively. The amplitude of T wave revealed -0.01 $\pm$ 0.15,-0.02$\pm$ 0.13, 0.01 $\pm$ 0.08, 0.02$\pm$ 0.12, 0.01 $\pm$ 0.11 and -0.03$\pm$ 0.09 mV, respectively. The duration time of P wave revealed 0.05 $\pm$ 0.01, 0.04$\pm$ 0.01, 0.05$\pm$ 0.02, 0.05 $\pm$ 0.02, 0.04$\pm$ 0.01 and 0.04$\pm$ 0.01 sec, respectively. The duration time of QRS complex revealed 0.05 $\pm$ 0.02,0.05$\pm$ 0.01, 0.05 $\pm$ 0.01, 0.04$\pm$ 0.01, 0.05$\pm$ 0.01 and 0.05 $\pm$ 0.01 sec, respectively. The duration time of PR interval revealed 0.08$\pm$ 0.01, 0.07$\pm$0.01,0.08$\pm$ 0.03, 0.08$\pm$0.01, 0.08$\pm$ 0.01 and 0.08$\pm$0.01 sec, respectively. The duration time of QT interval revealed 0.23$\pm$ 0.06, 0.22$\pm$ 0.05, 0.23 $\pm$ 0.06, 0.23$\pm$ 0.06, 0.24$\pm$ 0.05 and 0.22$\pm$ 0.02 sec, respectively. No significant changes were observed in e amplitude of P and T waves. The amplitude of QRS complex in ketamine group was higher than that of TZ group. However, no significant changes were observed in both intra-group and inter-group. There were no significant changes in the duration time of P wave, QRS complex and PR interval obtained from both groups. Also, the duration time of QT interval in TZ group was significantly longer at 30 min.(P< 0.05) an that of 10 minutes after injection. However, significant difference was not found between two groups. The mean cardiac electric axis in ketamine group tended to decrease until 30 min. after injection and then gradually increase. However, mean cardiac electric axis of TZ group was increased until 30 min. after injection and then decreased. But significant differences were not observed between groups. These results suggest that the ECG pattern after TZ injection to non-human primates reared in korea was established. It was also considered that the injection of ketamine and TZ didn't significantly affect on ECG pattern of the non-human primates.

Studies on electrocardiogram of the normal Korean native cattle II. Wave forms and amplitudes of the unipolar precordial chest leads (정상적(正常的)인 한우(韓牛)의 심전도(心電圖)에 관(關)한 연구(硏究) II. 흉부단극유도(胸部單極誘導)의 파형(波形)과 전위(電位))

  • Choi, In-hyuk;Kim, Soo-young;Kim, Nam-soo;Suh, Doo-seok
    • Korean Journal of Veterinary Research
    • /
    • v.33 no.4
    • /
    • pp.735-746
    • /
    • 1993
  • Electrocardiographic parameters of amplitude and the shape of waves on the unipolar precordial chest leads in the normal Korean native cattles have been measured with a 3 channel electrocardiograph built in a computed and analysis. The study was conducted on 98 heads of mean age of 17.6 months. The wave forms of P, T and QRS complex wave in all leads showed various types. The parameters of the amplitude in the wave types showed the most frequency in each lead that were analyzed as follow : 1. In P wave, amplitudes of positive type showed a frequency of 92.9% and 93.9% in leads $CV_6LU$ and $CV_6LL$ that were $83.8{\pm}31.0{\mu}V$ and $76.0{\pm}30.7{\mu}V$, and negative type showed a frequency of 97.9% in lead V 10 that were $-80.2{\pm}29.4{\mu}V$, respectively. But the plate type in leads $CV_6RU$ and $CV_6RL$ showed frequency of 48% and 58.3%, respectively. 2. Average amplitude of the QRS complex were in a range of $277.0{\pm}154.0{\mu}V$ to $648.2{\pm}146.2{\mu}V$(mean of $418.8{\pm}139.4{\mu}V$) in all leads that were manifested the Low-Voltage QRS complex(below 1 mV in unipolar precordial leads). Average amplitudes of each wave type in the QRS complex were $-250.0{\pm}139.8{\mu}V$ and $-399.2{\pm}226.8{\mu}V$ in the QS group types that showed a frequency of 50.0% and 82.5% in the leads $CV_6LU$ and $CV_6LL$, respectively. And average amplitudes of the R group types showed a frequency of 85.6%, 56.1% and 75.8% in the $CV_6RU$, $CV_6RL$ and $V_{10}$ that were $321.5{\pm}142.1{\mu}V$, $271.6{\pm}139.9{\mu}V$ and $552.4{\pm}132.7{\mu}V$, respectively. 3. In T waves, Amplitudes of the positive type showed a frequency of 60.2%, 46.9% and 83.7% in leads of $CV_6LL$, $CV_6RU$ and $CV_6RL$ that were respectively $184.7{\pm}93.7{\mu}V$ $103.7{\pm}64.43{\mu}V$ and $111.8{\pm}39.3{\mu}V$, the negative type showed a frequency of 62.2% and 93.7% in leads $CV_6LU$ and $V_{10}$ that were $142.2{\pm}82.1{\mu}V$ and $-280.3{\pm}107.2{\mu}V$, respectively. 4. Average amplitude of ST segment were $3.7{\pm}33.1{\mu}V$, $0.9{\pm}23.1{\mu}V$, $10.9{\pm}28.6{\mu}V$, $5.8{\pm}28.3{\mu}V$ and $-34.7{\pm}48.4{\mu}V$ in leads $CV_6LL$, $CV_6RU$, $CV_6RL$, $CV_6LU$ and $V_{10}$ respectively.

  • PDF

Effects of Cyclobuxine D on the Electrocardiogram (ECG) and Heart Rate in Anesthetized Rats and Isolated Frog Heart (Cyclobuxine D의 흰쥐에 있어서 ECG와 심박동수에 패한 작용과 적출 개구리 심장에 대한 작용)

  • Lee, Jong-Hwoa;Park, Young-Hyun;Cho, Byung-Heon;Kim, Yu-Jae;Kim, Jong-Bae;Kim, Chun-Sook;Cha, Young-Dong;Kim, Young-Suk
    • The Korean Journal of Pharmacology
    • /
    • v.22 no.2
    • /
    • pp.105-114
    • /
    • 1986
  • This study was undertaken to search for a new antiarrhythmic agent in natural plants. Extracts of Buxus microphylla var. koreana Nakai have been used as folk remedies of several diseases, including malaria and venereal disease, but any study on the pharmacological actions of this plant has not yet been carried out and its active ingredients have not been identified. In our laboratory, we isolated buxuletin (nonalkaloid) and cyclobuxine D (steroidal alkaloid) from Buxus microphylla var. koreana Nakai and reported their pharmacological actions: diuretic effects of buxuletin in rabbits and hypotensive effect of cyclobuxine D in rats. In the present study, we investigated the effect of cyclobuxine D on isolated frog heart and heart rate in urethane anesthetized rats. In order to clarify the mechanism of bradycardic effect of cyclobuxine D, we examined the changes of the ECG parameters (PR, QRS and R ${\alpha}$ T interval) produced by intravenous injection of cyclobuxine D in anesthetized rats. Cyclobuxine D depressed the contractile force in isolated frog heart and exerted a dose-dependent bradycardic effect in anesthetized rats. Intracerebroventricular injection of cyclobuxine D caused a fall in blood pressure and an increase in heart rate, but those effects were not significant. Cyclobuxine D prolonged the PR interval and RaT interval (${\alpha}$ Tindicates the apex of T), but was without significant effects on the duration of the QRS complex and PRc in urethane anesthetized rats.

  • PDF

Characteristic wave detection in ECG using complex-valued Continuous Wavelet Transforms

  • Berdakh, Abibullaev;Seo, Hee-Don
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.4
    • /
    • pp.278-285
    • /
    • 2008
  • In this study the complex-valued continuous wavelet transform (CWT) has been applied in detection of Electrocardiograms (ECG) as response to various signal classification methods such as Fourier transforms and other tools of time frequency analysis. Experiments have shown that CWT may serve as a detector of non-stationary signal changes as ECG. The tested signal is corrupted by short time events. We applied CWT to detect short-time event and the result image representation of the signal has showed us that one can easily find the discontinuity at the time scale representation. Analysis of ECG signal using complex-valued continuous wavelet transform is the first step to detect possible changes and alternans. In the second step, modulus and phase must be thoroughly examined. Thus, short time events in the ECG signal, and other important characteristic points such as frequency overlapping, wave onsets/offsets extrema and discontinuities even inflection points are found to be detectable. We have proved that the complex-valued CWT can be used as a powerful detector in ECG signal analysis.

Studies on- Electrocardiogram of the Normal Korean Native Goat 1. Standard Limb Leads and Unipolar Limb Leads (정상적인 한국 흑염소의 심전도에 관한 연구 1. 표전지유도와 단극지유도)

  • 최인혁;김선기;김추철;최인방;김남수
    • Journal of Veterinary Clinics
    • /
    • v.14 no.2
    • /
    • pp.319-337
    • /
    • 1997
  • The electrocardiographic (ECG) parameters in the normal Korean black goat have been measured with a 3-channel Electrocardiograph and computed, analyzed. ECG in 243 black goats were made with the limb leads (I, II, III, aVR, aVL, aVF), that were recorded conduction parameters of wave and interval, and were analyzed as to shape and amplitude of the P and T waves and the components of the QRS complex. Heart rate were recorded by the ECG which were a mean of 106.1$\pm $21.8 beats/min. Average conduction times in the PR, the QRS complex and the QTc interval were recorded 103.9$\pm $34.9 msec., 58.3$\pm $23.2 msec. and 302.6$\pm $67.8 msec., in the P and T wave duration recorded 24.8$\pm $6.4 msec. and 51.7$\pm $10.8 msec. respectively. The shape of wave in each leads were observed various types, and any spacial wave type appeared the highest frequency in each lead that ware shown less than 60%, and these frequent rate and average amplitudes as fallow: 1. In P waver the frequent rate and average amplitudes of the positive type showed in leads I, II and aVL that were 54.8% (93.0$\pm $ 33.2 $\mu $V), 50.5% (90.1$\pm $30.5 $\mu $V) and 41.7% (58.5$\pm $ 31.1 $\mu $V). Average amplitude of the negative type showed the frequent rate of 49.8% in lead aVE which was -77.6$\pm$ 25.2 $\mu $V. Biphasic type in leads III and aVF were 46.1% (108.4 $\mu $V, -90.2 $\mu $V.) and 45.7% (137.4 $\mu $V, -105.4 $\mu $V.), and amplitudes between positive and negative of it were significant difference. 2. The highest amplitudes of the QRS complex in all leads were 534.8$\pm $ 232.3 $\mu $V of lead II. The frequent rate and amplitudes of the R wave type in the I, II, III and aVF were 30.2% (277.8 $\pm $131.3 $\mu $V), 45.1% (393.1$\pm $114.2 $\mu $V), 48.5% (349.3$\pm $178.3 $\mu $V) and 54.9% (334.4$\pm $129.7 $\mu $V), and QS ways type in the lead aVL was 49.5% (359.2$\pm $195.5$\mu $V), and RS and QS wave types in the lead a VR were 43.3% (312.4 $\mu $V, -212.7 $\mu $V.) and 41.1% (399.2$\pm $92.2 $\mu $V), respectively. 3. In T wave, the frequent rata and amplitudes of the positive type in the leads I, II, III and aVF were 44.6% (207.9$\pm $ 97.1 $\mu $V), 41.6% (245.1$\pm $92.1 $\mu $V), 46.9% (189.8$\pm $ 82.7 $\mu $V) and 53.0% (195.4197.8 $\mu $V), and the negative in the lead aVR was 41.2% (-230.7$\pm$ 103.1 $\mu $V), respectively. The positive and negative types in the lead aVe appeared with same frequent rate of 43.2%.4. Frontal plane vectors for P, QRS, and T were found to lie at 38.1$\pm $ 21.5, 142.0$\pm $ 57.2, and 117.2$\pm $ 63.9 degrees, respectively. These results in ECG of goats may be served to the limited purposes as to conduction parameters, arrhythmias except abnormal ECG because of waveforms, amplitudes and electrical axis of it were variability.

  • PDF