• Title/Summary/Keyword: Q분석 기법

Search Result 228, Processing Time 0.027 seconds

A Study on the Development of an Instrument for Knowledge Contribution Assessment (조직 구성원의 지식기여도 평가 도구 개발에 관한 연구)

  • Na, Mi-Ja;Kym, Hyo-Gun
    • Information Systems Review
    • /
    • v.6 no.2
    • /
    • pp.113-135
    • /
    • 2004
  • This paper defines appraisal items and weights of the items for the purpose of developing an appraisal instrument that objectively measures employee's effectiveness of knowledge contribution. Deductive research is used for the development of appraisal items and delphi method for the development of weights of the items. In the deductive research the term, "effectiveness of knowledge contribution" is first defined. Then knowledge contribution activities are classified as "dimension of explicit contribution" and " dimension of tacit contribution" due to the characteristics of knowledge. Each dimension is divided again by components. The dimension of explicit contribution is divided according to the content of knowledge, and the dimension of tacit contribution is divided according to the extent of tacitness of knowledge contribution. The total components of dimensions are 7. The dimension of explicit contribution is composed of factual knowledge and procedural knowledge. The factual knowledge is made up of "procedural knowledge outcome" and "other factual knowledge". The procedural knowledge is made up of "procedural knowledge manual" and "lessons-learned procedural knowledge". The dimension of tacit contribution is composed of "agency", "model" and "Q&A". The basic framework for measuring 7 components of knowledge contribution is quantitative and qualitative approach. This paper is premised on the assumption that the outcomes of employee's knowledge contribution activities are recorded in the knowledge management systems in order to evaluate them objectively. The appraisal items are defined as follows: at the dimension of explicit contribution, in quantitative approach, "the upload number" or "performance number", and in qualitative approach, other employee's "referred number" and other employee's "content and format satisfaction evaluation"; at the dimension of tacit contribution, "demanded number of performance" After the development of appraisal items by the deductive method, delphi method was used for the analysis of the weights of the items with the total degree of knowledge contribution, 100. This research does not include the standard marks of the appraisal items. It is because when companies apply this appraisal instrument, they could use their own standard appraisal marks of the appraisal items considering their present situations and companies' goals. Through this almost desert-like research about the appraisal instrument of employee's knowledge contribution effectiveness, it proposes a cornerstone in the research field of appraisal instrument, which provides a standard for employee's knowledge contribution appraisal, and appraisal items that make organizational knowledge to be managed more systemically in business sites.

The Impact of BIS Regulation on Bank Behavior in Asset Management (신 BIS 자기자본규제가 은행자산운용행태에 미치는 영향)

  • Oh, Hyun-Tak;Choi, Seok-Gyu
    • The Korean Journal of Financial Management
    • /
    • v.26 no.3
    • /
    • pp.171-198
    • /
    • 2009
  • The primary purpose of this study is to examine the impact of new BIS regulation, which is the preparations to incorporate not only credit risk but also market and operation risk, on the bank behaviors. As methodology, SUR(seemingly unrelated regression) and pool unit test are used in the empirical analysis of banks survived in Korea. It is employed that quarterly data of BIS capital ratio, ratio of standard and below loans to total loans, ratio of liquid assets to liquid liabilities, allowances for credit losses, real GDP, yields of corporate bonds(3years, AA) covering the period of 2000Q1~2009Q1. As a result, it could be indicated that effectiveness and promoting improvements of BIS capital regulation policy as follows; First, it is explicitly seen that weight of lending had decreased and specific gravity of international investment had increased until before BIS regulation is built up a step for revised agreement in late 2001. Second, after more strengthening of BIS standard in late 2002, banks had a tendency to decrease the adjustment of assets weighted risk through issuing of national loan that is comparatively low profitability. Also, it is implicitly sought that BIS regulation is a bit of a factor to bring about credit crunch and then has become a bit of a factor of economic stagnation. Third, as the BIS regulation became hard, it let have a effort to raise the soundness of a credit loan because of selecting good debtor based on its credit ratings. Fourth, it should be arranged that the market disciplines, the effective superintendence system and the sound environment to be able to raise enormous bank capital easily, against the credit stringency and reinforce the soundness of banks etc. in Korea capital market.

  • PDF

The Structure of the Plant Community in Seonamsagol(Valley), Jogyesan(Mt.) Provincial Park, Suncheon City (순천시 조계산도립공원 선암사골 계곡부 식물군집구조)

  • Kim, Jong-Yup
    • Korean Journal of Environment and Ecology
    • /
    • v.26 no.4
    • /
    • pp.593-603
    • /
    • 2012
  • This study was carried out to investigate the ecological succession sere and conservative value, and to provide the basic data for the planning of the Provincial Park Management in Seonamsagol(Valley), Jogyesan(Mt.) Provincial Park(altitude 884m), Suncheon City, Korea by analysing the structure of the plant community. Twenty plots(size is $20m{\times}20m$) were set up at an altitude of range from 315m to 480m. As a result of analysis of TWINSPAN which is one of the ordination technique, the plant communities were divided into four groups which are community I(Quercus variabilis community), community II(Q. serrata community), community III(Decideous broad-leaved plant community), and community IV(Carpinus tschonoskii community). The warmth index is $104^{\circ}C{\cdot}month$ based on the data of monthly mean temperature during the past thirty years(1981~2010), so we found out that the vegetation of the study site located in the South Temperate Climate Zone. We supposed that the ecological succession sere of the study site is in the early stage of developing from Q. serrata community to Carpinus tshonoskii community, however we should do a long-term monitoring to investigate the changes of the ecological succession each plant community, meanwhile Sasa borealis was dominant species in the shrub layer. The diameter at breast height of specimen tree is range from 20 to 55cm(average 36cm) and the height of that is range from 14 to 35m(average 23cm). The age of community I was 64 years old, that of community II was from 59 to 64 years old, that of community III was from 51 to 62 years old, and that of community IV was from 41 to 68 years old, thus the age of the study site is about from 38 to 72 years old. According to the index of Shnnon's diversity(unit: $400m^2$), community IV was ranged from 0.8452 to 1.2312, community III was ranged from 0.8044 to 1.1404, community II was ranged from 0.8221 to 0.9971, and community I was 0.8324.

A study on non-local image denoising method based on noise estimation (노이즈 수준 추정에 기반한 비지역적 영상 디노이징 방법 연구)

  • Lim, Jae Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.518-523
    • /
    • 2017
  • This paper proposes a novel denoising method based on non-local(NL) means. The NL-means algorithm is effective for removing an additive Gaussian noise, but the denoising parameter should be controlled depending on the noise level for proper noise elimination. Therefore, the proposed method optimizes the denoising parameter according to the noise levels. The proposed method consists of two processes: off-line and on-line. In the off-line process, the relations between the noise level and the denoising parameter of the NL-means filter are analyzed. For a given noise level, the various denoising parameters are applied to the NL-means algorithm, and then the qualities of resulting images are quantified using a structural similarity index(SSIM). The parameter with the highest SSIM is chosen as the optimal denoising parameter for the given noise level. In the on-line process, we estimate the noise level for a given noisy image and select the optimal denoising parameter according to the estimated noise level. Finally, NL-means filtering is performed using the selected denoising parameter. As shown in the experimental results, the proposed method accurately estimated the noise level and effectively eliminated noise for various noise levels. The accuracy of noise estimation is 90.0% and the highest Peak Signal-to-noise ratio(PSNR), SSIM value.

Optimal design of impeller in fan motor unit of cordless vacuum cleaner for improving flow performance and reducing aerodynamic noise (무선진공청소기 팬 모터 단품의 유량성능 향상과 공력소음 저감을 위한 임펠라 최적설계)

  • Kim, KunWoo;Ryu, Seo-Yoon;Cheong, Cheolung;Seo, Seongjin;Jang, Cheolmin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.5
    • /
    • pp.379-389
    • /
    • 2020
  • In this study, the flow and noise performances of high-speed fan motor unit for cordless vacuum cleaner is improved by optimizing the impeller which drives the suction air through flow passage of the cordless vacuum cleaner. Firstly, the unsteady incompressible Reynolds averaged Navier-Stokes (RANS) equations are solved to investigate the flow through the fan motor unit using the computational fluid dynamics techniques. Based on flow field results, the Ffowcs-Williams and Hawkings (FW-H) integral equation is used to predict flow noise radiated from the impeller. Predicted results are compared to the measured ones, which confirms the validity of the numerical method used. It is found that the strong vortex is formed around the mid-chord region of the main blades where the blade curvature change rapidly. Given that vortex acts as a loss for flow and a noise source for noise, impeller blade is redesigned to suppress the identified vortex. The response surface method using two factors is employed to determine the optimum inlet and outlet sweep angles for maximum flow rate and minimum noise. Further analysis of finally selected design confirms the improved flow and noise performance.

Monitoring the Restoration of Evergreen Broad-Leaved Forests in the Warm-Temperate Region(III) (난온대 기후대의 상록활엽수림 복원 모니터링(III))

  • Kang, Hyun-Mi;Kang, Ji-Woo;Kim, Ji-Hae;Sung, Chan-Yong;Park, Seok-Gon
    • Korean Journal of Environment and Ecology
    • /
    • v.36 no.1
    • /
    • pp.87-101
    • /
    • 2022
  • This study analyzed changes in the vegetation structure of 16 permanent plots (experimental and control) installed in Wando Arboretum in 1996 to monitor the long-term change process of evergreen broad-leaved forests in warm temperate. Especially, this study discusses the effects of trial treatment (selection cutting and plant introduction), introduced as a restoration technique in 1996, on vegetation development. In communities dominated by Quercus acuta in the canopy (permanent plots 1 through 3), this species's mean important percentage (MIP) decreased, and the evergreen broad-leaved species was introduced from outside increased, likely to change the vegetation structure in the future. The expansion of the evergreen broad-leaved species group was also confirmed in Q. acuta-deciduous broad-leaved forests (permanent plots 5 and 7) and Pinus densifloraforests (permanent plots 9 and 10). In the experimental plots where thinning was carried out, the zoochory (the dispersal of seeds by birds), Cinnamomum yabunikkei, Neolitsea sericea, Machilus thunbergii, etc., and the expansion of the influence of evergreen broad-leaved species were remarkable, so it is considered to have effectively promoted the vegetation development in warm temperate forests. Although evergreen broad-leaved species were planted in the experimental plot to change vegetation structure, it seems the effect on the change was weak due to the small amount of planting. Compared to other vegetation types, the change in the vegetative structure of the pine forest to an evergreen broad-leaved forest was clear due to the decline of P. densiflora and P. thunbergii.

Effects of Growing Density and Cavity Volume of Containers on the Nitrogen Status of Three Deciduous Hardwood Species in the Nursery Stage (용기의 생육밀도와 용적이 활엽수 3수종의 질소 양분 특성에 미치는 영향)

  • Cho, Min Seok;Yang, A-Ram;Hwang, Jaehong;Park, Byung Bae;Park, Gwan Soo
    • Journal of Korean Society of Forest Science
    • /
    • v.110 no.2
    • /
    • pp.198-209
    • /
    • 2021
  • This study evaluated the effects of the dimensional characteristics of containers on the nitrogen status of Quercus serrata, Fraxinus rhynchophylla, and Zelkova serrata in the container nursery stage. Seedlings were grown using 16 container types [four growing densities (100, 144, 196, and 256 seedlings/m2) × four cavity volumes (220, 300, 380, and 460 cm3/cavity)]. Two-way ANOVA was performed to test the differences in nitrogen concentration and seedling content among container types. Additionally, we performed multiple regression analyses to correlate container dimensions and nitrogen content. Container types had a strong influence on nitrogen concentration and the content of the seedling species, with a significant interaction effect between growing density and cavity volume. Cavity volumes were positively correlated with the nitrogen content of the three seedling species, whereas growing density negatively affected those of F. rhynchophylla. Further, nutrient vector analysis revealed that the seedling nutrient loading capacities of the three species, such as efficiency and accumulation, were altered because of the different fertilization effects by container types. The optimal ranges of container dimension by each tree species, obtained multiple regression analysis with nitrogen content, were found to be approximately 180-210 seedlings/m2 and 410-460 cm3/cavity for Q. serrata, 100-120 seedlings/m2 and 350-420 cm3/cavity for F. rhynchophylla, and 190-220 seedlings/m2 and 380-430 cm3/cavity for Z. serrata. This study suggests that an adequate type of container will improve seedling quality with higher nutrient loading capacity production in nursery stages and increase seedling growth in plantation stages.

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF